• Title/Summary/Keyword: Measurement instruments

Search Result 648, Processing Time 0.03 seconds

A Review of the Pain and Function Assessment Instruments for Shoulder Disease Patients in Korean Medicine Clinical Studies Published in South Korea (국내 한의임상연구에서의 어깨질환 환자의 통증 및 기능측정도구 사용에 대한 현황분석)

  • Lee, Geon-Yeong;Jo, Hee-Geun;Seol, Jae-Uk;Kim, Shin-Ae
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.28 no.1
    • /
    • pp.33-51
    • /
    • 2018
  • Objectives The purpose of this study is to analyze the current status of measurement instruments used to evaluate pain and function for shoulder disease patients in Korean Medicine clinical studies published in South Korea. Methods 5 Korean online databases from January 2007 to July 2017 were used to source articles for the review. Data of pain and function assessment instruments, measurement methods, time point and frequency for shoulder assessment were extracted. And it was analyzed by investigating the frequency of use for each item. Results A total of 78 studies met the selection criteria. There were many studies with no description for pain assessment instruments or inconsistent measurement methods. In the function assessment, the frequency of use was low and there were a lot of use of instruments with low validity and reliability. Conclusions To develop the objectivity of clinical research, further clinical studies, active use of measurement instruments, and standardization of measurement methods are needed.

Evaluation of the Possession of Measurement and Analytical Instruments among Domestic Work Environment Monitoring Service Providers (I) (국내 작업환경측정기관의 측정 및 분석장비 보유실태에 대한 고찰 (I))

  • Jang, Jae-Kil
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.250-260
    • /
    • 2013
  • Objectives: The aim of this study is to analyze the current status of the possession of measurement and analytical instruments among work environment monitoring organizations that have been designated by the Ministry of Employment and Labor (MoEL) in Korea. Methods: Data for measurement and analytical instruments were gathered by inspectors who had been assigned by the Korea Occupational Safety and Health Agency (KOSHA) and MoEL during the evaluation program for designated work environment monitoring service providers in 2012. Data for 11 monitoring instruments and nine analytical instruments were collected from 108 organizations. Basic data such as the type of service provides and the size of employment were also recorded by the inspector. Results: The total number of personal air samplers including high and low flow rates operated in Korea was 5,418, with average of 50.2. Average operation number of noise dosimeters was 35.0, while 3,780 dosimeters were used in 108 work environment monitoring organizations. There were 10,488 monitoring instruments in total. All service providers possessed at least one AAS and GC in their analytical laboratory. Total number of HPLC/MS was five, followed by ICP/MS of seven, with an average of 0.07. Conclusions: Based on the data, domestic work environment monitoring service providers possessed relatively reasonable measurement and analytical instruments. Nearly all instruments had been imported from advanced countries such as USA, UK and Japan. Periodic gathering of data on these instruments may help maintain good workplace monitoring results and the health of workers at the sites.

Evaluation of the Possession of Measurement and Analytical Instruments in Domestic Work Environment Monitoring Service Providers (II) (국내 작업환경측정기관의 측정 및 분석장비 보유실태에 대한 고찰 (II))

  • Jang, Jae-Kil
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.182-192
    • /
    • 2014
  • Objectives: The aim of this study is to analyze the current status of possession of measurement and analytical instruments at work environment monitoring organizations and their relationships with human resources, including the number of professional engineers and evaluation scores resulting from evaluation programs in 2012. Materials: Data for measurement and analytical instruments were gathered by inspectors who had been assigned by the Korea Occupational Safety and Health Agency(KOSHA) and the Ministry of Employment and Labor(MoEL) during the evaluation program for 2012. Data for 11 monitoring instruments and nice pieces of analytical equipment were collected from 103 organizations. Additional data such as the type of service provides and the number of professional engineers employed were also recorded by the inspectors. Evaluation scores could be acquired from KOSHA. Results: Comprehensive Occupational Health Service Providers showed good operation quality, while University or Hospital Subsidiary and Work Environment Monitoring Organizations recorded relatively poor results. Evaluation scores correlated well with the possession of measurement instruments and human resources for each organization. High yields provided by professional engineers also showed statistically-associated contributions to evaluation scores and monitoring instrument possession. Compared with monitoring instruments, the amount of analytical equipment had little positive impact on organizations' competence. Conclusions: The evaluation results for domestic monitoring organizations revealed that human resources, possession of instruments, and the quality of employees were critical factors for operating the corporations. Each organization should give considerable effort to improving their ability to strengtheninternal quality, resulting in high-yield production for workers and employers by providing improved workplace monitoring services.

Analysis of Measurement Error for PM-10 Mass Concentration by Inter-Comparison Study (비교 측정을 통한 PM-10 질량농도의 오차 분석)

  • Jung, Chang-Hoon;Cho, Yang-Sung;Hwang, S.M.;Jung, Y.G.;Ryu, J.C.;Shin, D.S.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.6
    • /
    • pp.689-698
    • /
    • 2007
  • Particular attention is paid to the validity of PM-10 measurement using beta attenuation method. In this study, the inter-comparison studies were undertaken for PM-10 sampler with different measuring methods. The three beta attenuation monitoring instruments (BAM1020, FH C-14, and DIGS-150) and filter based gravitational method using High Volume Air Sampler were collocated and mass concentrations were compared from August to November, 2006. The results of the investigation show that beta attenuation monitoring instruments are comparable with gravitational method within 10% of measurement error. For specific conditions under high humidity and high concentrations, the inter-comparison results also showed a relatively good agreement and this can be explained as the effect of inlet heating of beta attenuation instrument. Subsequently, this study shows that beta attenuation monitoring instruments can be equivalently used with reasonable validity when compared gravimetric method.

Introduction of Total Management System for Oceanographic Instruments Using RFID(Radio Frequency IDentification) (전자태그를 이용한 해양 연구 기기 및 장비 통합 관리시스템)

  • Lee, Jung-Han;Hwang, Keun-Choon;Kim, Eun-Soo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.3
    • /
    • pp.192-204
    • /
    • 2011
  • With the international increasing of the important of oceanic researches related to climate changes, resources conservation and development and the advanced application of oceanic researches, advanced countries in ocean have developed the systematic management systems for oceanographic instruments. Despite the increasing realization of need for the establishment of management system, no systematic management system has been built in KOREA. There is an ungently need to construct the efficient and professional maintenance and management system of oceanographic instruments that are extremely expensive for meeting the increasing demands of oceanographic observation and investigation. In this paper, the present possession of oceanographic instruments in KOREA and the need for the establishment of management systems for oceanographic instruments are discussed. In addition, we introduce the total management system for oceanographic instruments using a RFID(Radio Frequency IDentification) at KORDI and discuss the necessity of the introduction and establishment for producing high quality data in oceanic researches.

The optimum displacement measurement to estimate realtime states of Beam structure (휨부재의 실시간 상태 평가를 위한 최적변위 계측)

  • Kim Hyung-Joong;Kim Sung-Nam;Park Nam-Hoi;Park Jong-Sub;Lim Jung-Soon;Kang Young-Jong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.127-132
    • /
    • 2006
  • Recently, several displacement measuring instruments such a GPS are substantially developed by development of an artificial satellite. Considering this trend, in future displacement measurement will be a very efficiency method, therefore we need to develop structure maintenance & management by using displacement measuring instruments. In this study, I suggest to maintenance & management method about simple beams and cantilever beams which are very important structurein civil engineering by using displacements. I suggest a system which trace behavior of beams by combining some measurement points and a specific displacement function and research that tl1e proper number of measurement and optimum measurement points to efficiently use the system.

  • PDF

Environmental Testing for Precision Parts and Instruments (정밀부품 및 기기에 대한 환경시험기술)

  • Choi, Man-Yong;Park, Jeong-Hak;Yun, Kyu-Tek
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.6
    • /
    • pp.642-649
    • /
    • 2001
  • Precision parts and instruments are tested to evaluate performance in development-process and product-step to prement a potential defect due to a failure design. In this paper, Environmental test technology, which is the basis of reliability analysis, is introduced with examples of test criterion, test method for products, encoder and traffic signal controller, and measuring instruments. Recently, as the importance of the environmental test technology is recognised. It is proposed that tranining of test technician and technology of jig design and failure analysis are very essential.

  • PDF

Measurement Instruments for Superior Product Development: A Case Study of Deli Serdang Cassava in Indonesia

  • P, Remus Hasiholan;TARMIZI, Hasan Basri;RAHMANTA, Rahmanta;PURWOKO, Agus
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.5
    • /
    • pp.1139-1145
    • /
    • 2021
  • This study is aimed at developing a measurement instrument for the superior product development program of Deli Serdang cassava, Indonesia. This research population is the target population of Deli Serdang Micro, Small and Medium-sized Enterprises (MSMEs) which produces cassava. The sample was randomly selected and consisted of 300 MSMEs. The study method is research and development with confirmatory factor analysis using Amos software. The data collection technique was a questionnaire. Study results used the maximum likelihood method which showed that the validity and reliability instruments met the ideal loading factor value > 0.5 and a significance value of p (0.000). The model built also meets the fit criteria based on the Goodness of Fit Model Standard. All instruments are presented to build and measure the superior cassava product development program by Deli Serdang MSMEs. This superior product development program comprises (1) economic contribution (with a loading factor value of 0.76) (2) social aspects (with a loading factor value of 0.76) (3) cultural aspects (with a loading factor value of 0.99) and (4) institutional (with a loading factor value of 0.87). This result means that all instruments have proven construct validity.

Development of Measurement System for the Underwater Explosion Shock Test of Naval Ships (함정의 수중폭발 충격시험을 위한 계측장비 시스템 개발)

  • 박일권;조대승;김종철
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.4
    • /
    • pp.66-74
    • /
    • 2003
  • In non-contact underwater explosion shock test of a real naval ship, measurement of shock loadings and responses should require onboard system to be able to safely trigger an explosive and to simultaneously and successfully measure scores of shock signals in the deteriorated environment. For this purpose, we have developed a shock-hardened measurement system resistible to 170g peak acceleration having 4 msec duration by resiliently mounting general purpose measurement instruments in racks. The system can simultaneously measure and record 200 signals to evaluate shock leadings and responses of the test ship by triggering an explosive and measurement instruments at the same time. We prove the performance of the developed system by introducing the signal acquisition results from of a real ship underwater shock test, firstly performed in Korea.

A Systematic Review on Measurement Instruments of Bilateral Upper Extremity Function (양측 상지 기능 평가도구에 관한 체계적 고찰)

  • Lee, Joo-Hyun;Lee, Ye-Jin;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.5 no.1
    • /
    • pp.7-22
    • /
    • 2016
  • Objective : This study was conducted to review about instrument for bilateral upper extremity assessment. Methods : We searched published papers in Medline database. The keywords used in the search were 'upper extremity' and 'motor activity', 'activities of daily living' and 'assessment', 'instrument', 'disability evaluations'. In total of 68 papers, 44 assessment instruments was extracted. We analyzed about numbers, subjects, methods, reliability, validity, responsiveness of assessment instruments about bilateral upper limb function comparing unilateral, combined bilateral and unilateral instruments. Results : The numbers of bilateral measurement tool were 2 in a total of upper extremity measurement tools. Also, subjects were patients with stroke and measurement was based on performance. The reliability, validity and responsiveness of tools were high. Conclusions : Futher study will be needed to development and research about instrument of bilateral upper extremity.