• Title/Summary/Keyword: Measurement distortion

Search Result 404, Processing Time 0.023 seconds

Full-field Distortion Measurement of Virtual-reality Devices Using Camera Calibration and Probe Rotation (카메라 교정 및 측정부 회전을 이용한 가상현실 기기의 전역 왜곡 측정법)

  • Yang, Dong-Geun;Kang, Pilseong;Ghim, Young-Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.6
    • /
    • pp.237-242
    • /
    • 2019
  • A compact virtual-reality (VR) device with wider field of view provides users with a more realistic experience and comfortable fit, but VR lens distortion is inevitable, and the amount of distortion must be measured for correction. In this paper, we propose two different full-field distortion-measurement methods, considering the characteristics of the VR device. The first is the distortion-measurement method using multiple images based on camera calibration, which is a well-known technique for the correction of camera-lens distortion. The other is the distortion-measurement method by measuring lens distortion at multiple measurement points by rotating a camera. Our proposed methods are verified by measuring the lens distortion of Google Cardboard, as a representative sample of a commercial VR device, and comparing our measurement results to a simulation using the nominal values.

Fabrication of the focal length and distortion measurement system (초점길이 및 왜곡수차 측정장치 제작)

  • 조현모
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.82-86
    • /
    • 1990
  • A camera type optical bench system equipped with a lens collimator and an image analyzer is fabricated to measure the equivalent focal length and distortion of lenses. This system is automatized by the computer which controls stepping motors. A nodal slide optical bench system equipped with an off axis reflective collimator is fabricated and improved by using rotating arms and air bearing system. distortion measurement on a wide angle lens using the camera method and the nodal slide method is reported. Defocusing error in the distortion measurement with the nodal slide optical bench is analyzed and improved by iteration method to search the correct image point.

  • PDF

Limitation of Measurement System in Application of Angular Distortion Criterion to Structure Near Road Embankment (도로 성토 시 인근 구조물에 각변위기준 적용에 있어 계측시스템의 한계성)

  • Kim, Taehyung;Kim, Dongin;Kim, Yuntae;You, Sangho;Jung, Youngeun;Kim, Sungwoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.1
    • /
    • pp.43-51
    • /
    • 2014
  • Angular distortion due to differential settlement is one of the critical factors which influences on the stability and serviceability of a structure. The angular distortion criterion proposed by Bjerrum is generally used in practice. However, the measurement system used in field especially a road embankment site did not properly represent the angular distortion of a structure. The problem was related to the shortage and not proper installation of measurement gauges, and the incorrect understanding of the basic concept of angular distortion in interpretation of measurement data. These things were reveled by analyzing the measured data in the road embankment site. An improved measurement system has been suggested as a so-called "relative displacement measurement system" between columns with automatic measurement.

Distortion Correction in Magnetic Resonance Images on the Measurement of Muscle Cross-sectional Area (자기공명영상을 이용한 근육 단면적 측정법의 활용을 위한 영상왜곡보정)

  • Hong, Cheol-Pyo;Lee, Dong-Hoon;Park, Ji-Won;Han, Bong-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.66-72
    • /
    • 2012
  • Purpose: The purpose of this study is to explore the importance of the image distortion correction in the cross sectional area measurement for the iliopsas muscle, tensor fasciae latae muscle, gluteus maximus muscle and the knee extensor muscles, by using (magnetic resonance imaging) MRI. Methods: This study was performed using an open 0.32T MRI system. To estimate the image distortion, T1 images for an AAPM homogeneity/linearity phantom were acquired, and the region in which the maximum geometric distortion was less than or equal to the pixel size (1.6 mm) of the images, it was defined as the distortion correction-free region. The T2 images for a human subject's pelvis and thigh in normal positions were obtained. Then, after the regions of interest in the pelvis and thigh were moved into the distortion correction-free region, T2 images for the pelvis and thigh were scanned with the same imaging parameters used in the previous T2 imaging. The cross-sectional areas were measured in the two T2 images that were obtained in the normal position, and the distortion correction-free region, as well as the area error caused by geometric image distortion was calculated. Results: The geometrical distortion is gradually increased, from the magnet center to the outer region, in axial and coronal plane. The cross-sectional area error of gluteus maximus muscle and the knee extensors was as high as 9.27% and 3.16% in before and after distortion correction, respectively. Conclusion: The cross-sectional area of the muscles that suffered from the geometrical distortion is necessary to correct for the estimation of the intervention.

Error Analysis of the Image Measurement System (영상 측정 시스템의 오차 분석)

  • 김준희;유은이;사승윤;김광래;유봉환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.490-495
    • /
    • 1996
  • Though the increment of using computer vision system in modern industry, there are lots of difficulties to measure precisely because of measurement error distortion phenomenon. Among these reasons, the distortion of edge is dominant reason which is occurred by the blurred image. The blurred image is happened when camera can not discriminate its precise focus. To calibrate and generalize distortion phenomenon is important. Thus, we must fix the discrimination criteria which is collected by image recognition of precise focus. Also, radial distortion causes an inward or outward displacement of a given image point from its ideal location. This type of distortion is mainly caused by flawed radial curvature curve of the elements. Thus, we were analyzed the distortion in terms of the changed with lens magnification.

  • PDF

DISTORTION OF FLOW MEASUREMENT BY VARIOUS INLET VELOCITY PROFILE OF ORIFICE FLOWMETER (오리피스 유량계의 입구 속도 분포에 따른 유량 계측 왜곡 특성)

  • Shin, B.S.;Kim, N.S.;Lee, S.K.;Bae, Yong-Beom;Keum, O.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.596-600
    • /
    • 2011
  • In this numerical analysis, the distortion of flow measurement by inlet velocity profile of orifice flowmeter was investigated. To validate the numerical method, the convergence was monitored and the grid dependency was also checked. realizable k-e model was selected and y+ was about 50 in this calculation. the results shows that the pressure at the pressure tab near pipe wall was changed by inclined inlet velocity profile and it leads to distorted a measurement values of flow through the orifice plate from -3.8% to 9%. Therefore, the fully developed inlet flow was required for accurate flow measurement by orifice flowmeter. If not, the orifice plate installed at wrong location should be re-installed or additional actions should be taken.

  • PDF

Noise Criteria for the Calculation of Response Spectra (응답스펙트럼 계산을 위한 잡음기준)

  • 노명현;최강룡;윤철호
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.238-246
    • /
    • 2003
  • By using simulated ground motions, which is sum of earthquake signals and noise, we measured the distortion of response spectra due to noise. We found that the distortion is more closely related to the signal-to-noise (S/N) ratio of root-mean-square (RMS) measurement than that of conventional peak measurement. Given a S/M ratio, the distortion of absolute acceleration response spectra is independent on the earthquake magnitude, while that of relative displacement response spectra has a strong dependence on the earthquake magnitude. This means that, when we calculate response spectra from time histories, we can efficiently predict the distortion of acceleration response spectra simply by measuring the RMS SJN ratios, or the distortion of displacement response spectra by combining the RMS S/N ratios and the earthquake magnitudes.

  • PDF

Direct Measurement of Distortion of Optical System of Lithography (노광 광학계의 왜곡수차 측정에 관한 연구)

  • Joo, WonDon;Lee, JiHoon;Chae, SungMin;Kim, HyeJung;Jung, Mee Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.3
    • /
    • pp.97-102
    • /
    • 2012
  • In general, one of the methods used to measure distortion is to use the full image of the regular pattern. However, because of low accuracy, this method is mainly used for an optical system such as a camera.. In order to measure distortion with high accuracy less than 1um, one can use the method of measuring the exact position of a mask image. In this case, a high accuracy stage with a laser encoder is required. In this paper, we investigate measurement of the distortion of high accuracy with a simple manual stage. The main idea is that we split and measure the mask image with the overlapping area by using CCD or CMOS, and then we get an exact position of the mask image by integrating the adjacent split images. We use the Canny Edge Detection method to get the position information of the mask image and we researched the process to exactly calculate distortion by using coordinate transformations and a least square method.

Research on Automatic Measurement Program to shorten Test Time for FEU of HCTRS (대용량무선전송장비 전처리장치의 시험 소요시간 단축을 위한 자동 측정 프로그램 연구)

  • Shin, Suk-Ho;Cho, Tae-Chong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.5
    • /
    • pp.45-49
    • /
    • 2020
  • FEU which is a important device in HCTRS of TICN amplifies transmission signals. Tests of intermodulation distortion and harmonic distortion for FEU have been performed manually, and take a lot of time. This paper improves the test methods using program that set up the measurement instruments and read the data automatically. This proposal allows intermodulation distortion and harmonic distortion test simultaneously. And the new test methods show that the measurement time is shorter than before. Also, it is expected that efficient quality assurance is possible because the test time can be independently managed, unlike the previous methods, where the test time was determined according to the skill level of the operator.

An Advanced Phase Angle Measurement Algorithm And Error Analysis (개선된 위상 측정 알고리즘과 오차 해석)

  • 송영석;김재철;최인규;박종식
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.3
    • /
    • pp.25-32
    • /
    • 2004
  • An advanced algorithm for measurement of phase angle between two sinusoidal signals is proposed in this paper. This algorithm uses discrete sample data of two input signals for calculation of phase angle and amplitude. And the key parameters of the measurement algorithm are described by analytical express, so the calculation of phase angle is simplified. In this paper it is proved that harmonic distortion of the input sinusoidal signals does not affect the measurement value of phase angle by using the proposed algorithm when a whole cycle is sampled. And measurement error by the white Gaussian noise is very small compared by other algorithms.