• 제목/요약/키워드: Measurement criteria

검색결과 987건 처리시간 0.024초

KSR-III의 전기체 모달 시험 (Ground Vibration Test for Korea Sounding Rocket - III)

  • 우성현;김영기;이동우;문남진;김홍배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.441-447
    • /
    • 2002
  • KSR-III(Korea Sounding Rocket - III), which is being developed by Space Technology R&D Division of KARI(Korea Aerospace Research Institute) will be launched in late 2002. It is a three-stage, liquid propellant rocket which can reach 250 km altitude and will carry out observation of ozone layer and scientific experiments, such as microgravity experiment, and atmospheric measurement. KSR-III is believed to be an intermediate to the launch vehicle capable of carrying a satellite to its orbit. Space Test Department of KARI performed GVT(Ground Vibration Test) fer KSR-III EM at Rocket Test Building of KARI. GVT is very important for predicting the behavior of rocket in its operation, developing flight control program and performing aerodynamic analysis. This paper gives an introduction of rocket GVT configuration and information on test procedures, techniques and results of It. In this test. to simulate free-free condition, test object hung in the air laterally by 4 bungee cords specially devised. For the excitation of test object, pure random signal by two electromagnetic shakers was used and total 22 frequency response functions were achieved. Polyreference parameter estimation was performed to identify the modal parameters with MIMO(Multi-Input-Multi-Output) method. As the result of the test, low frequency mode shapes and modal parameters below 60Hz were identified

  • PDF

토양 손실 평가에 의한 식생매트의 허용 소류력 결정 (Determination of Permissible Shear Stresses on Vegetation Mats by Soil Loss Evaluation)

  • 이두한;이동섭;김명환
    • 한국산학기술학회논문지
    • /
    • 제14권11호
    • /
    • pp.5956-5963
    • /
    • 2013
  • 친환경 하천사업의 활성화로 식생매트의 사용은 증가하고 있으나 수리적 안정성에 대한 평가기법은 제시되지 않은 실정이다. 본 연구는 호안용 식생매트 제품의 객관적인 수리안정성 시험 기법 개발을 위해 수행하였다. 이를 위해서 식생매트 2종에 대한 실규모 실험을 수행하여 수리량을 측정하고 분석하여 작용 소류력을 계산하였다. 작용 소류력에 대한 토양손실평가를 위하여 지상라이다에 의한 측량을 수행하고 실험 전후의 하상고 변화를 평가하여 토양손실지수(CSLI)를 산정하였으며, 작용 소류력과 함께 도시하여 허용 소류력을 정량적으로 평가하였다. 하상고에 대한 정밀 측량 결과 분석에 의해서 식생매트가 안정한 경우에는 하상 변동이 국부적으로 제한되나, 불안정으로 판정되는 경우에는 식생매트 하부에서 비교적 큰 규모의 하상 변동이 발생하며 이는 자연 하상의 거동과 유사함을 확인하였다. 이상의 연구를 통해서 ASTM D 6040에 의한 식생매트의 허용 소류력 평가가 파괴 메카니즘 및 토양손실판정 기준에서 유효함을 확인할 수 있었다.

피부온을 기반으로 한 가전제품의 감성 평가 프로토콜 수립을 위한 문헌 조사 (A Literature Review for an Emotion Evaluation Protocols Based on Skin Temperature for Home Appliances)

  • 전은진;이승훈;김희은;유희천
    • 한국의류산업학회지
    • /
    • 제22권2호
    • /
    • pp.240-249
    • /
    • 2020
  • This study reviews studies that used skin temperature in order to establish an emotion evaluation protocol based on skin temperature for home appliances. A survey of skin temperature evaluation papers was conducted by the following five stages: (1) keyword search, (2) title screening, (3) abstract screening, (4) full paper screening, and (5) relevance evaluation. Selected papers were reviewed for: purpose, recruitment criteria of participants, the number of participants, apparatus, procedure, measures, analysis methods, and major findings. Thermistor sensors and thermography are used for the measurement of skin temperature. Skin temperature sensors are attached to 4 - 10 locations on the body and their mean of skin temperature is calculated by Ramanatan's 4-point or Hardy & Dubois's 7-point method. Semantic differential (SD) method and thermography measuring facial surface temperature have been used for emotion evaluation. The SD method provides a set of adjective pairs related to a product and evaluates changes in emotion from the use of the product. The range of facial surface analyzed is defined in the thermal image and temperature changes before and after the evaluation are analyzed. The evaluation items of home appliances include form, color, material, aesthetics, satisfaction, novelty, convenience, pleasantness, and excellence. Many existing emotion studies using skin temperature do not apply physiological and psychological methods. This study provides basic data to establish a skin temperature and emotion evaluation protocol by examining literature for skin temperature and evaluation of sensitivity.

다품목 공용 제약설비인 바이알 충전기에 대한 세척공정 밸리데이션 (Cleaning Validation Studies for Multi-Purpose Facility : Vial Filling Machine)

  • 최한곤;양호준;김영란;성준호;황마로;김종오;용철순
    • Journal of Pharmaceutical Investigation
    • /
    • 제39권4호
    • /
    • pp.263-267
    • /
    • 2009
  • The purpose of this study is to evaluate the efficacy of stipulated cleaning process, and the prohibition of cross-contamination and microbiological contamination, which inadequate cleaning in multi-production could occur, through cleaning validation of multi-purpose facility used to produce five biopharmaceutical products as sterile injection. After production of five biopharmaceutical products such as hGH, rhGCSF, rhEPO, rhFSH and rhIFN using vial filling machine, the cleaning validation such as residual analysis of active ingredients or human serum albumin, measurement of total organic carbon (TOC), residual analysis of detergent and microbiological contamination were carried out. In the case of rhGH and rhGCSF clean validations, drug residues were not detected. Furthermore, in the case of rhEPO, rhFSH and rhIFN clean validations, human serum albumin residues were not detected. At TOC (total organic carbon) analysis, all clean validations gave the TOC of about average 137.93%, not more than 150% of acceptance criteria. At sodium analysis for the checking of residues of cleaning agent, sodium residues were not detected. In sterility test, they showed no microbiological contamination of bacteria and fungi. Thus, this cleaning validation was determined as successful in protection of cross-contamination and induction of safety in multi-purpose facility.

고준위폐기물 처분장의 완충재용 국내산 벤토나이트의 특성 측정 (Measurement of Properties of Domestic Bentonite for a Buffer of an HLW Repository)

  • 유맑고밝게빛나라;최희주;이민수;이승엽
    • 방사성폐기물학회지
    • /
    • 제14권2호
    • /
    • pp.135-147
    • /
    • 2016
  • 심지층 처분시스템에서 완충재는 지하수 유입으로부터 처분용기를 보호하고, 방사성 핵종 유출을 저지하기 위한 중요한 방벽의 하나이다. 이에 완충재는 장기 건전성, 낮은 수리전도도, 낮은 유기물의 함량, 높은 핵종저지능, 높은 팽윤성, 높은 열전도도 등 기술적 요건을 충족시켜야 하며 이는 정량적 분석결과를 바탕으로 결정될 수 있다. 국내의 경우 한국원자력연구원에서는 1997년부터 경주지역에서 생산되는 벤토나이트를 완충재 후보물질로 연구를 지속하고 있다. 본 논문에서는 최근 동일 지역에서 생산된 벤토나이트(KJ-II)의 7가지 물리적 및 화학적 특성을 평가하였다. 분석 결과, 국내산 벤토나이트의 몬모릴로나이트 함량은 약 65% 정도이며, 벤토나이트는 Ca형 벤토나이트이다. 본 논문을 통해 완충재 후보물질의 성능평가 항목과 분석 방법에 대한 기준을 제시하고자 하였다.

Anti-Cyclic Citrullinated Peptide(Anti-CCP) 측정에 대한 연구 (A Study on the Measurement of Anti-Cyclic Citrullinated Peptide (Anti-CCP))

  • 서설
    • 대한임상검사과학회지
    • /
    • 제39권1호
    • /
    • pp.42-48
    • /
    • 2007
  • This study was carried out to review and evaluate anti-CCP ELISA assay for diagnostic in RA patients from an early arthritis clinic (EAC). The subjects were obtained from patients visiting the outpatient clinic of the Dept. of Rhumatology med.of P hospital in Daegu, during 6 months from July 1, 2006 to December 31, 2006. The subjects were 140 cases : 80 cases from RA patients (60 women and 20 men; mean age 58 years; range, 32-68 years) confirmed by clinical diagnostic. 39 cases of these RA patients were classified as having early RA (EAC). 50 cases (non-RA) did not fulfill the criteria for RA, and 10 cases were from healthy individuals. We performed the analysis with solid phase-ELISA method (ETI-max3000, Diasorin; Italy) for anti-CCP and Nephelometry assay (Roche/Hitachi 902 analyzer; USA) for RF. The results obtained were summarized as follows ; anti-CCP ELISA is more specific than RF Nephelometry assay (specificity 94% vs 90%) to diagnose RA patients with suspected EAC (early arthritis clinic). The combination test "anti-CCP and RF" had a very high specificity (specificity 98.3%, PPV; RA group 96%, EAC 95%), the difference was statistically significant (p<0.05). Anti-CCP ELISA had more sensitivity in EAC (Early arthritis clinic) patients than chronic RA patients (sensitivity 64% vs 24%, respectively), anti-CCP of RA group and EAC group was more specific than RF (anti-CCP PPV; 92%, 89% vs 89%, 81% respectively), the difference was statistically significant (p<0.05). The difference of antibody concetration between anti-CCP and RF for RA and the control group is statistically significant (p<0.05). In conclusion, anti-CCP ELISA testing may be useful if performed concomitantly with RF Nephelometry assay to diagnose RA patients with suspected EAC (early arthritis clinic).

  • PDF

강상자형교의 강바닥판에서 설계온도하중을 위한 유효온도 산정 (Evaluation of Effective Temperature for Estimate Design Thermal Loads in Steel Deck of Steel Box Girder Bridges)

  • 신동욱;김경남;최철호;이성행
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권6호
    • /
    • pp.77-87
    • /
    • 2013
  • 국내 교량 설계에서 온도 하중에 대한 현재 LSD (한계 상태 설계법)는 다양한 교량 형식에 대한 동일한 기준을 적용하고 있다. 본 연구에서는 유효 온도를 산정하기 위해 실제 크기의 상판이 없는 강상자형거더교 시험체를 제작하였다. 1년동안 강상자형거더교모형의 18개 지점에서 온도데이터를 측정하였다. 측정된 데이터를 바탕으로 대기 온도에 따른 교량단면내 유효 온도를 산정 하였다. 유로 코드의 유효 온도와 비교할 때 실측 유효온도의 결과는 매우 유사한 상관 관계를 보였다. 따라서, 본 데이터를 기반으로 산정 된 유효 온도는 국내 교량 설계에 온도 하중에 적합한 설계 기준을 제시하기 위한 기초 자료로 사용할 수 있다.

항공기 투명체의 편각개념 설계 및 측정 시스템 개발 (Concept Design of Angular Deviation and Development of Measurement System for Transparency in Aircraft)

  • 문태상;우성조;권성일;류광열
    • 한국항공우주학회지
    • /
    • 제38권11호
    • /
    • pp.1123-1129
    • /
    • 2010
  • TA-50 항공기에 적용되는 투명체의 편각은 실제목표와 투명체를 통해 조종사가 인식하는 목표와 차이를 유발시켜, 부정확한 조준 및 이로 인한 무장계통의 정확도를 저하시킨다. 이러한 문제를 해결하기 위해 TA-50 항공기에서는 원드실드 투명체의 편각을 실측하여 편각 계수 형태로 항공기의 통합임무시현컴퓨터에 입력, 각도 편차를 보정하여 전방상향 시현기에서 목표물에 정확히 조준되도록 한다. 이러한 작동원리를 실전에 적용하기 위해 본 연구에서는 편각 자동측정장비를 국내 최초 독자적으로 개발하였다. 또한 편각 유도공식 산출 등 개발개념 및 운영 체계와 장비의 신뢰성 검증을 위한 정확성 및 정밀성에 대한 내용을 다룬다. 본 연구를 통해 개발한 장비의 정확성은 최종 판정기준인 1% 미만으로 매우 적합하였으며, 정밀성 또한 최종 판정기준을 모두 만족하여 매우 적합하다는 결과를 얻었다. 본 연구를 통해 개발된 편각 자동측정장비는 우수한 품질로 입증되어 캐노피 투명체의 국방규격에 등재되어 사용되고 있다.

슬랙스 맞음새 평가를 위한 하반신 체형 유형화에 관한 연구 (A Study on the Classification of Lower Body Shape Type for Fit Evaluation of Slacks)

  • 김선영;남윤자
    • 패션비즈니스
    • /
    • 제20권2호
    • /
    • pp.181-196
    • /
    • 2016
  • This study intended to suggest criteria for selection of subjects by lower body shape types necessary for evaluating slacks. For this, the characteristics were examined by lower body parts which would influence the fit of slacks on 3D human body shape data of the front and sides of the lower body for lower body shaping. The frequency of subjects by lower body shape types and the boundary points for discrimination of each type were suggested so that they could be available in selecting subjects. Using the data from Size Korea(2004), indirect measurement values measured on the front and sides of the lower body among 3D human body shape data of 175 subjects were analyzed. Their height, waist, and hip circumference fell under the range of standard deviation based on the mean of women aged 18~24 years, and then lower body shaping was conducted by combining the front and side shapes of the lower body. The front of the lower body was classified into four sections: average waist/average hip type(F1), average waist/narrow hip tyle(F2), narrow waist/narrow hip type(F3) and narrow waist/wide hip type(F4) and the sides of the lower body were divided into four sections: average abdomen/average hip type(S1), flat abdomen/average hip type(S2), average abdomen/protrude hip type(S3)and round abdomen/flat hip type(S4), and thus total 16 lower body types were created by cross analysis. Besides, discriminant analysis suggested the boundary points for each shape type of the front and sides of the lower body as a criterion for deciding lower body shape type of each subject

나노클레이 첨가에 따른 할로겐프리 난연컴파운드의 수직난연 특성 향상에 관한 연구 (A Study on Perpendicular Flame Retardant Characteristic Improvement of Halogen-free Flame Retardant Compounds by Nanoclay Addition)

  • 황찬연;양종석;성백용;김지연;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.51-56
    • /
    • 2015
  • The object of this study is to obtain the optimum mix proportion of halogen free compound with flame resistance and, for the purpose, thermal/electrical characteristics test are conducted using compatibilizing agents, flame resistance agents, hydroxide aluminum, sunscreen, antioxidant and silicon oil on the base resin of linear low density polyethylene (LLDPE), Ethylene vinyl acetate copolymer (EVA). Existing compound method accompanies many requirements to be satisfied including a lot of addition of flame resistance agents, prohibition of impact on mixing capability with base and property and etc. In this study, different from the existing method, the optimum mix proportion is determined and experimented by adding nano clay. Oxygen index test shows no difference between specimens while T-6, T-9 shows oxygen index of 29[%] and 26[%], respectively. This is concluded that hydroxide aluminum, which is a flame resistance agent, leads low oxygen index. From UL94-V vertical flame resistance test, the combustion behavior is determined as V-0, Fail based on UL94-V decision criteria. Viscometry shows low measurements in specimens with separate addition of compatibilizing agents or nano clay. Volume resistivity test shows low measurement mainly in specimens without compatibilizing agents. Therefore, with the flame resistance compound shows better performance for thermal/electrical property and the optimum mix proportion are achieved among many existing materials.