Evaluation of TDF ash as a Mineral Filler in Asphalt Concrete (TDF ash를 채움재로 사용한 아스팔트 콘크리트 물성 평가)

  • Choi, MinJu;Lee, JaeJun;Kim, HyeokJung
    • International Journal of Highway Engineering
    • /
    • v.18 no.4
    • /
    • pp.29-35
    • /
    • 2016
  • PURPOSES : The new waste management policy of South Korea encourages the recycling of waste materials. One material being recycled currently is tire-derived fuel (TDF) ash. TDF is composed of shredded scrap tires and is used as fuel in power plants and industrials plants, resulting in TDF ash, which has a chemical composition similar to that of the fly ash produced from coal. The purpose of this study was to evaluate the properties of an asphalt concrete mix that used TDF ash as the mineral filler. METHODS : The properties of the asphalt concrete were evaluated for different mineral filler types and contents using various measurement techniques. The fundamental physical properties of the asphalt concrete specimens such as their gradation and antistripping characteristics were measured in accordance with the KS F 3501 standard. The Marshall stability test was performed to measure the maximum load that could be supported by the specimens. The wheel tracking test was used to evaluate the rutting resistance. To investigate the moisture susceptibility of the specimens, dynamic immersion and tensile strength ratio (TSR) measurements were performed. RESULTS : The test results showed that the asphalt concrete containing TDF ash satisfied all the criteria listed in the Guide for Production and Construction of Asphalt Mixtures (Ministry of Land, Infrastructure and Transport, South Korea). In addition, TDF ash exhibited better performance than that of portland cement. The Marshall stability of the asphalt concrete with TDF ash was higher than 7500 N. Further, its dynamic stability was also higher than that listed in the guide. The results of the dynamic water immersion and the TSR showed that TDF ash shows better moisture resistance than does portland cement. CONCLUSIONS : TDF ash can be effectively recycled by being used as a mineral filler in asphalt, as it exhibits desirable physical properties. The optimal TDF ash content in asphalt concrete based on this study was determined to be 5%. In future works, the research team will compare the characteristics of asphalt concrete as function of the mineral filler types.

The metallic composition of airborne particles in seven locations of Seoul city, Korea (대기 분진 중 중금속 성분의 공간적 농도분포 특성 비교: 서울시 7개 관측점을 중심으로)

  • Choi, Bae-Jin;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.143-151
    • /
    • 2003
  • In the present study, we made measurements of PM-bound metal concentrations from seven different urbanized locations in Seoul for the period covering March 2001 through May 2002. The measurement data were analyzed to explore the possible influences of spatial factors on metal distribution characteristics. To check for the importance of such aspects on metal distribution characteristics, the measured data were compared between different metals and between different sites by several criteria including (1) coefficient of variation (CV) values; (2) temporal variability; and (3) the abundance of strongly correlated pairs. The overall results of our study indicate strong diversity in the distribution characteristics of different metals. It is found that some metals (like Fe, Mn, and Pb) tend to exhibit strong compatibility among different study sites. However, no such compatibility appears to exist for certain metals like Cu. To account for the importance of spatial factors, complex relationships between source/sink processes and geochemical characteristics of a given metallic component may have to be examined in a systematic manner.

Elementary Mathematics Education Research Trends in Japan - Focused on the last 10 years - (일본의 초등수학교육 연구 동향 - 최근 10년간을 중심으로 -)

  • Jin, Yeong Su;Kang, Hong Jae
    • Journal of Elementary Mathematics Education in Korea
    • /
    • v.18 no.2
    • /
    • pp.341-355
    • /
    • 2014
  • The purpose of this study was to analyze the research trends of elementary mathematics education in Japan. For this purpose, 192 papers published by Japan Society of Mathematics Education for the last 10 years(2004-2013) were analyzed according to there criteria. First, as for research topics, the frequent topics in order were instructional design and methods (36.7%), analysis of curriculum and textbook, general studies, learners' perspectives and abilities, evaluation, teacher education, education engineering and parish. Second, the contents were researched by the order of number and operations (47.4%), geometry, regularity, measurement and probability and statistics. Finally, research subjects of this study were researched by the order of students(39.3%), teachers. Papers dealing with lower graders as well as pre-service teachers were rare. And article dealing with low-achievers and gifted students were not founded. On the basis of this result, we hope it will provide the follow-up and the idea of the elementary mathematics education in Korea and also help various and balanced development.

  • PDF

Real-time Detection of Deep Sleep using Electrodermal Activity (피부전기활동을 이용한 실시간 깊은 수면 검출 알고리즘의 개발)

  • Jung, Da Woon;Choi, Sang Ho;Joo, Kwang Min;Lee, Yu Jin;Jeong, Do-Un;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.204-210
    • /
    • 2015
  • Although many studies have analyzed the relationship between electrodermal activity (EDA) and sleep stages, a practical method for detecting sleep stage using EDA has not been suggested. The aim of this study was to develop an algorithm for real-time automatic detection of deep sleep using the EDA signal. Simultaneously with overnight polysomnography (PSG), continuous measurement of skin conductance on the fingers was performed for ten subjects. The morphometric characteristics in the fluctuations of EDA signal were employed to establish the quantitative criteria for determining deep sleep. The 30-sec epoch-by-epoch comparison between the deep sleep detected by our method and that reported from PSG exhibited an average sensitivity of 74.6%, an average specificity of 98.0%, and an average accuracy of 96.1%. This study may address the growing need for a reliable and simple measure for identifying sleep stage without a PSG.

Comparing Endoscopy and Upper Gastrointestinal X-ray for Gastric Cancer Screening in South Korea: A Cost-utility Analysis

  • Chang, Hoo-Sun;Park, Eun-Cheol;Chung, Woo-Jin;Nam, Chung-Mo;Choi, Kui-Son;Cho, Eun;Cho, Woo-Hyun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2721-2728
    • /
    • 2012
  • Background: There are limited data evaluating the cost-effectiveness of gastric cancer screening using endoscopy or upper gastrointestinal x-ray in the general population. Objective: To evaluate the cost-effectiveness of population-based screening for gastric cancer in South Korea by decision analysis. Methods: A time-dependent Markov model for gastric cancer was constructed for healthy adults 30 years of age and older, and a deterministic sensitivity analysis was performed. Cost-utility analysis with multiple strategies was conducted to compare the costs and effects of 13 different screening alternatives with respect to the following eligibility criteria: age at the beginning of screening, screening interval, and screening method. The main outcome measurement was the incremental cost-effectiveness ratio. Results: The results revealed that annual endoscopic screening from ages 50-80 was the most cost-effective for the male population. In the females, biennial endoscopy screening from ages 50-80 was calculated as the most cost-effective strategy among the 12 screening alternatives. The most cost-effective screening strategy may be adjustable according to the screening costs and the distribution of cancer stage at screening. The limitation was that effectiveness data were obtained from published sources. Conclusions: Using the threshold of $19,162 per quality-adjusted life year on the basis of the Korean gross domestic product (2008), as suggested by the World Health Organization, endoscopic gastric cancer screening starting at the age of 50 years was highly cost-effective in the Korean population. The national recommendation for gastric cancer screening should consider the starting age of screening, the screening interval, and the screening modality.

Novel Dosimeter for Low-Dose Radiation Using Escherichia coli PQ37

  • Park, Seo-Hyoung;Kim, Tae-Hwan;Cho, Chul-Koo;Lee, Yeon-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.3
    • /
    • pp.524-528
    • /
    • 2001
  • The measurement of radiation response using simple and informative techniques would be of great value in studying the genetic risk following occupational, therapeutic, or accidental exposure to radiation. When patients receive radiation therapy, many suffer from side effects. Since each patient receives a different dose due to different physical conditions, it is important to measure the exact dose of radiation received by each patient to lessen the side effects. Even though several biological dosimetric systems have already been developed, there is no ideal system that can satisfy all the criteria for an idean dosimetric system, especially for low-dose radiation as used in radiation therapy. In this study, an SOS Chromotest of E. coli PQ37 was evaluated as a novel dosimeter for low-dose gamma-rays. E. coli PQ37 was originally developed to screen chemical mutagens using the SOS Chromotest-a colorimtric assay, based on the induction of ${\beta}$-galactosidase ue to DNA damage. The survival fraction of E. coli PQ37 decreased dose-dependently with an increasing dose of cobalt-60 gamma-rays. Also, a good linear correlation was found between the biological damage revealed by the ${\beta}$-galactosidase expression and the doses of gamma-rays. The expression of ${\beta}$-galactosidase activity that responded to low-dose radiation under 1 Gy was $Y=0.404+(0.089{\pm}0.3)D+(-0.018{\pm}0.16)D^2$ (Y, absorbance at 420 nm; D, Dose of irradiation) as calculated using Graph Pad In Plot and Excel. When a rabbit was fed with capsules containing an agar block embdded with E. coli PQ37 showed a linear response to the radiation doses. Accordingly, the results confirm that E. coli PQ37 can be used as a sensitive biological dosimeter fro cobalt-60 gamma-rays. To the best of our knowledge, this is the first time that a bacterium has been used as a biological dosimeter, especially for low-dose radiation.

  • PDF

A Study on Evaluation Criteria for quantitatively OSS Selection (정량적인 OSS 선정을 위한 평가지표 연구)

  • Lee, Hoo-Jae;Kim, Doo-Yeon;Choi, Il-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1863-1871
    • /
    • 2012
  • Utilization of the former OSS was mainly focused on the usage of system applications such as operating system and DBMS. However, nowadays many companies are trying to make use of OSS based on the application rather than the system software. However, selection of base OSS is the most important to develop of application for utilizing OSS. The scope of existing OSS evaluation studies is covered the entire OSS quality. Thus existing studies of evaluation of OSS selection is insufficient. Also, the result of assessment is based on qualitative measurement rather than quantitative ones. In this paper, we derives only the indicators for selection among the existing OSS assessment indicators and suggests the assessment indicator that is capable of quantitative assessment in accordance with the characteristics of the project. The proposed assessment indicator is divided into an initial assessment indicator that can be assessed with only the information within the OSS community, and the detailed assessment indicator through metrics to make quantitative measurements possible. In this way, an objective basis can be provided through quantitative scores & indicators when selecting OSS.

Comparison of Measurement Methods and Size Fraction of Fine Particles (PM10, PM2.5) from Stationary Emission Source Using Korean Standard and ISO: Coal Power Plant and Refinery (국내공정시험기준과 ISO 방법을 이용한 고정오염원 미세먼지 (PM10, PM2.5) 측정 방법 및 입경분율 비교: 석탄화력발전소, 석유정제시설 중심으로)

  • Youn, Jong-Sang;Han, Sehyun;Jung, Yong-Won;Jeon, Ki-Joon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.4
    • /
    • pp.342-350
    • /
    • 2017
  • We report mass concentration and size fraction of TPM, $PM_{10}$ and $PM_{2.5}$ according to Korea standard test method (ES 01301.1 and ES 01317.1) and ISO 23210 methods. Particulate matters were sampled in large stationary emission sources such as a coal power plant and B-C oil refinery. The Korea standard test method PM mass concentrations showed 3~3.5 times larger than the cascade impactor method. On the other hand, the size fraction results showed less than 5% difference (i.e. $PM_{2.5}/PM_{10}$) between two methods. Moreover, the correlation coefficient ($r^2$) is 0.84 between TPM results of the Korea standard test method and CleanSYS. These results suggested not only improvement of current test criteria in terms of technical and theoretical aspects. Further, additional measurements are required in various large stationary sources to compare current field data.

Emission Estimation and Exposure to Hazardous Gaseous Pollutants Associated with Use of Air Fresheners Indoors (실내 방향제 사용에 의한 유해 가스상 오염물질 배출 산정 및 노출 평가)

  • Jo, Wan-Kuen;Shin, Seung-Ho;Kwon, Gi-Dong;Lee, Jong-Hyo
    • Environmental Analysis Health and Toxicology
    • /
    • v.24 no.2
    • /
    • pp.137-148
    • /
    • 2009
  • This study quantitatively investigated the emissions of indoor air pollutants associated with the utilization of air fresheners indoors, and evaluated individual exposure to five specified indoor air pollutants, which were chosen on the basis of selection criteria. An electrically-polished stainless steel chamber (50L) was employed to achieve this purpose. Test air fresheners were selected through three steps: first, on the basis of market sales; second, on the basis on a preliminary head-space study; and lastly, on the basis of emissions of toxic compounds (benzene, ethyl benzene, limonene, toluene, and xylene). The empirical mathematical model fitted well with the time-series concentrations in the environmental chamber (in most cases, determination coefficient, $R^2{\gtrsim}$0.9), thereby suggesting that the empirical model was suitable for testing emissions. The concentration equilibrium appeared 180 min after the introduction of sample air fresheners into the chamber. Both the chamber concentrations of emission rates or factors varied greatly according to air freshener type. It is noteworthy that although benzene, ethyl benzene, toluene, and xylene were emitted from all test air fresheners, their exposure levels were not significant enough to result in any significant health risk. However, certain type of air fresheners were observed to emit significant amount of limonene, which is potentially reactive with ozone to generate secondary pollutants with oxidants such as ozone, hydroxyl radicals, and nitrogen oxides. The exposure levels to limonene associated with the utilization of three air fresheners were estimated to be 13 to 175 times higher than that of other air fresheners. This information can help consumers to select low-pollutant-emitting air fresheners.

A Study on the Quality Control and Operating System of Standard Reference Data(SRD) (참조표준데이터 품질관리 및 운영체계에 관한 연구)

  • Chae Kyun-shik;Lee Eung-Bong
    • Journal of Korean Library and Information Science Society
    • /
    • v.36 no.2
    • /
    • pp.283-305
    • /
    • 2005
  • Data produced during scientific and technical activities usually have value as standard reference data (SRD) which is a well-documented numeric value assessed for reliability and accuracy. The main criteria in the evaluation for SRD is how well their production is documented including a sample preparation, measurement method, data processing and so on, other than reference data. SRD is represented as a certified numeric value with uncertainty. In this study, the SRD in the area of material properties was introduced to provide understanding of SRD and its evaluation method. Also the national SRD system was studied. The national SRD system is composed of the center for the SRD, the data centers, and the committee. The role and task of those components were studied. The legislational and systematic supports for the system were proposed in this study.

  • PDF