• 제목/요약/키워드: Measurement Uncertainty Analysis

검색결과 328건 처리시간 0.023초

파이프 프루버의 측정불확도에 관한 연구 (A Study on the Measurement Uncertainty of Pipe Prover)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제24권10호
    • /
    • pp.1388-1398
    • /
    • 2000
  • A pipe prover is a flowmeter calibrator used in flow measurement field. Gravimetric and volumetric methods were applied to determine the basic volume of the pipe prover. Uncertainty of its basic volume measurement was evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainty of determining the basic volume was estimated from the sensitivity coefficient and the standard uncertainty of independent variables. It was found that the uncertainties of the weighing and volume measurements have dominant influence on that of the basic volume determination. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of the basic volume is shown clearly.

Uncertainty Analysis and Improvement of an Altitude TestFacility for Small Jet Engines

  • Jun, Yong-Min;Yang, In-Young;Kim, Chun-Taek;Yang, Soo-Seok;Lee, Dae-Sung
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제5권1호
    • /
    • pp.46-56
    • /
    • 2004
  • The verification and improvement of the measurement uncertainty have beenperformed in the altitude test facility for small gas turbine engines, which was built atthe Korea Aerospace Research Institute (KARI) in October 1999. This test is performedwith a single spool turbojet engine at several flight conditions. This paper discussesthe evaluation and validation process for the measurement uncertainty improvements usedin the altitude test facility. The evaluation process, defined as tests before the facilitymodification, shows that the major contnbutors to the measurement uncertainty are theflow meter discharge coefficient, the inlet static and total pressures, the cell pressureand the fuel flow rate. The measurement uncertainty is focused on the primary parametersof the engine performance such as airflow rate, thrust and specific fuel consumption (SFC).The validation process, defined as tests after the facility modification, shows that themeasurement uncertainty, in seal level condition, is tmproved to the acceptable level throughthe facility modification. In altitude test conditions, the measurement uncertainties arenot improved as much as the uncertainty in sea level condition.

담배 연기 중 휘발성 유기물질 분석에 대한 측정 불확도 산출 (Measurement Uncertainty for Analysis of Volatile Organic Compound in Cigarette Mainstream Smoke)

  • 가미현;조성일;김미주;이철희;지상운;정종수;김용하;민영근
    • 한국연초학회지
    • /
    • 제28권2호
    • /
    • pp.144-151
    • /
    • 2006
  • A measurement uncertainty for analysis of volatile organic compound (benzene) in cigarette mainstream smoke was carried out. In this study one point re-calibration method was used to estimate uncertainty for benzene. The measurement uncertainty was calculated based on the uncertainty sources of each analysis step, quality appraisal sources, drift and repeatability. As a result, the concentration and expanded uncertainty of benzene in cigarette mainstream smoke were measured as $38.08{\pm}4.36{\mu}g/cig$. Relative uncertainty of drift and repeatability obtained were 5% and 3%, respectively.

황색종 담배중 전알카로이드와 환원당 분석에 대한 불확도 측정 (Uncertainty of Total Alkaloids and Reducing Sugar Determination in Flue-cured Tobacco)

  • 백순옥;장기철;이운철;한상빈
    • 한국연초학회지
    • /
    • 제23권1호
    • /
    • pp.45-52
    • /
    • 2001
  • This study was carried out to evaluate the uncertainty in the analysis of total alkaloids and reducing sugar content in flue-cured tobacco. The sources of uncertainty associated with the analysis of total alkaloids and reducing sugar were the weighing of sample, the preparation of extracting solution, the addition of extracting solution into the sample, the preparation of standard solution, the precision of calibration curve for standard solution, the reproducibility of analysis, and the determination of water content in tobacco, etc. For the calculating uncertainties, Type A of uncertainty was evaluated by the statistical analysis of a series of observation, and Type B by the information based on supplier’s catalogue and/or certificated of calibration. It was shown that the main source of uncertainty was caused by the calibration curve of standard solution, the reproducibility of analysis, the volume measurement of 1$m\ell$, and the purity of nicotine reference material in the preparation of standard solution. The uncertainty in the addition of extracting solution, the sample weighing, the volume measurement of 100$m\ell$, and the determination of water content of tobacco contributed relatively little to the overall uncertainty. The expanded uncertainty of total alkaloids and reducing sugar in flue-cured tobacco at 95% level of confidence was $\pm$0.12% and $\pm$0.54%, respectively.

  • PDF

프로펠러 단독시험에 있어서 불확실성 해석 (Uncertainty Analysis for the Propeller Open Water Test)

  • 최군일;전호환;김재신;이정묵
    • 대한조선학회논문집
    • /
    • 제31권1호
    • /
    • pp.71-83
    • /
    • 1994
  • 프로펠러 단독시험에 대한 불확실성 해석을 수행하였다. 계측 값 및 계측 값으로부터 얻어진 결과에 대한 오차 원인, 요소 오차, 추정 오차, 오차 전파 및 이들의 감도 등에 대해서 자세히 언급하였다. 현대선박해양연구소에서 수행한 프로펠러 단독시험 결과에 대한 오차 한계는 일반 시험 결과의 오차 한계 ${\pm}2%$보다 적은 ${\pm}1%$로 나타났다. 이러한 불확실성 해석 수행으로 주오차 원인들을 쉽게 파악할 수 있으며 아울러 시험 정도 향상에도 유용하게 쓰여짐을 알 수 있었다.

  • PDF

몬테카를로 시뮬레이션을 이용한 시운전 선속-동력 성능에 대한 불확실성 해석 (Uncertainty Analysis for Speed and Power Performance in Sea Trial using Monte Carlo Simulation)

  • 서대원;김민수;김상엽
    • 대한조선학회논문집
    • /
    • 제56권3호
    • /
    • pp.242-250
    • /
    • 2019
  • The speed and power performance of a ship is not only a guarantee issue between the ship owner and the ship-yard, but also is related with the Energy Efficiency Design Index (EEDI) regulation. Recently, International Organization for Standardization (ISO) published the procedure of the measurement and assessment for ship speed and power at sea trial. The results of speed and power performance measured in actual sea condition must inevitably include various uncertainty factors. In this study, the influence for systematic error of shaft power measurement system was examined using the Monte Carlo simulation. It is found that the expanded uncertainty of speed and power performance is approximately ${\pm}1.2%$ at the 95% confidence level(k=2) and most of the uncertainty factor is attributed to shaft torque measurement system.

불확도 분석을 이용한 관성모멘트 측정장비의 신뢰도평가 (The Confidence Estimation of MOI Measurement Equipment using Uncertainty Analysis)

  • 김광로;강휘원;설창원
    • 항공우주시스템공학회지
    • /
    • 제12권3호
    • /
    • pp.53-57
    • /
    • 2018
  • 몬테카를로 시뮬레이션 방법과 측정불확도 표현 지침은 불확도 평가를 위해 가장 널리 사용되는 방법들이다. 본 논문에서는 자체 개발된 질량관성모멘트 측정장비의 신뢰도를 평가하기 위해 몬테카를로 방법과 GUM방법이 사용되었다. 결과에 따르면 GUM방법에 의해 평가된 불확도가 몬테카를로 방법에 의한 것보다 약간 과소평가되었고 그 차이는 GUM방법의 근사화에 기인한 것으로, 두 방법에 의해 평가된 관성모멘트 불확도들은 추정량의 1% 미만으로 개발된 관성모멘트 측정시스템의 높은 측정신뢰성을 보여준다.

유량측정방법에 따른 형산강유량의 불확실도 분석 (Uncertainty Analysis of Hyung San River Discharge due to the methods of Discharge Measurement)

  • 서규우;김수현;김대곤
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.1538-1542
    • /
    • 2005
  • This study is to secure more accurate data of the discharge on the measurement by gaining a reliable hydrological data through the comparison the present method of measuring them and the other way that is based ISO. This study suggests the applicable measurement method of the discharge that has reliance through general elements and the analysis of uncertainty by comparing and assaying the data of the Hyung San River that is measured by the present standard. The result of this study makes us realize that we should complement the measurement method of the discharge securing the reliable and accurate hydrological data Hydrological data is very important things to perform domestic river works or install some structure in river or coast. Securing reliable and accurate hydro-data and making a thesis should go on in other to do any construction in river or coast.

  • PDF

광 회절계를 이용한 격자 피치 표준 시편의 측정 및 불확도 해석 (Measurement of Grating Pitch Standards using Optical Diffractometry and Uncertainty Analysis)

  • 김종안;김재완;박병천;강주식;엄태봉
    • 한국정밀공학회지
    • /
    • 제23권8호
    • /
    • pp.72-79
    • /
    • 2006
  • We measured grating pitch standards using optical diffractometry and analyzed measurement uncertainty. Grating pitch standards have been used widely as a magnification standard for a scanning electron microscope (SEM) and a scanning probe microscope (SPM). Thus, to establish the meter-traceability in nano-metrology using SPM and SEM, it is important to certify grating pitch standards accurately. The optical diffractometer consists of two laser sources, argon ion laser (488 nm) and He-Cd laser (325 nm), optics to make an incident beam, a precision rotary table and a quadrant photo-diode to detect the position of diffraction beam. The precision rotary table incorporates a calibrated angle encoder, enabling the precise and accurate measurement of diffraction angle. Applying the measured diffraction angle to the grating equation, the mean pitch of grating specimen can be obtained very accurately. The pitch and orthogonality of two-dimensional grating pitch standards were measured, and the measurement uncertainty was analyzed according to the Guide to the Expression of Uncertainty in Measurement. The expanded uncertainties (k = 2) in pitch measurement were less than 0.015 nm and 0.03 nm for the specimen with the nominal pitch of 300 nm and 1000 nm. In the case of orthogonality measurement, the expanded uncertainties were less than $0.006^{\circ}$. In the pitch measurement, the main uncertainty source was the variation of measured pitch values according to the diffraction order. The measurement results show that the optical diffractometry can be used as an effective calibration tool for grating pitch standards.

GC/MS를 이용한 소변 중 대마 대사체 분석의 측정불확도 평가 (Uncertainty Evaluation of the Analysis of 11-Nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol in Human Urine by GC/MS)

  • 김진영;정재철;서승일;서용준;이정직;김종상;인문교
    • 약학회지
    • /
    • 제52권6호
    • /
    • pp.480-487
    • /
    • 2008
  • We described an estimation of measurement uncertainty in quantitative analysis of 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THCCOOH), the major metabolite of ${\Delta}^9$-tetrahydrocannabinol, in urine sample by solid-phase extraction (SPE) and GC/MS detection. The analytical results were compared and the different contributions to the uncertainty were evaluated. Inter-day and inter-person validation were performed using statistical analysis of several indicative factors. Measurement uncertainty associated with target analyte in real forensic samples was estimated using quality control (QC) data. Traceability of measurement was established through traceable standards, calibrated volumetric glassware and volume measuring device. The major factors of contribution to combined standard uncertainty, were calibration linearity, inter-day repeatability and inter-person reproducibility, while those associated with preparation of analytical standards and sampling volume were not so important considering the degree of contribution. Relative combined standard uncertainties associated with the described method was 12.05% for THCCOOH.