• 제목/요약/키워드: Measurement Table

검색결과 453건 처리시간 0.029초

한국인의 생명표 작성에 관한 연구 (A Study of Life Table of Korean People : Based on 1986 Data)

  • 김연희
    • 한국인구학
    • /
    • 제12권2호
    • /
    • pp.45-55
    • /
    • 1989
  • In recent years the life expectancy of the Korean people has been increasing appreciably because of the improvement in living conditions and public health facilities as well. However, there exist considerable constraints in the measurement of Korea's mortality rate. In elaboration, there are quite a few persons who do not submit birth and death reports, thereby lowering the reliability of statistical data. The 1978-1979 life table of the Korean people is still considered the latest one. Nevertheless, a decade has passed since its publication, and the need for a better life table reflecting realities is inc-reasingly growing. Capitalizing on the annual report of demographic statistics and demographic sample survey data m 1988, I have worked out the 1986 tentative life table of the Korean people and found out the following : 1. The male life expectancy in the 1978-1979 life table of the Korean people is 62.7 years old, and that of the female sex is 69.1 years old whereas the average life expectancy of the male sex in the 1986 life table stands at 66.3 years old, and that of the female sex is 74.5 years old. The average life expectancy is up by 3.5 years old for the male sex and also, up 5.4 years old for the female sex, res-pe ctively. 2. A gap between the male and female life expectancies in the 1978-1979 life table was 6.4 years old, while that of the 1986 life table was 8.2 years old. It means the female life expectancy has increased substantially. 3. The infant mortality rate has decreased, compared with the 1978-1979 level, yet it is still above those of Japan and Taiwan. 4. The mortality rate of the middle - aged men in the forties remains high, as was the case in the 1978-1979 period.

  • PDF

진동대시험을 이용한 콘크리트 표면 차수벽형 석괴댐의 내진성능 평가 (Evaluation of Resistance of Concrete-Face Rockfill Dam to Seismic Loading Using Shaking Table Test)

  • 하익수;김용성;서민우;박동순
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1118-1125
    • /
    • 2005
  • In this study, seismic safety of CFRD(Concrete-Face Rockfill Dam) type "D" dam in operation is evaluated from the results of 1-g shaking table test using similitude laws. Model dam is made by similitude law considering the grain size of prototype dam component. After the model dam is impounded to the normal water level(N.W.L), it is excited by artificial earthquake wave corresponding to standard design respond spectrum of the "D" dam site. Displacement response behavior of the dam is examined through the measurement of vertical and horizontal displacement of dam crest. Also, amplification characteristics of acceleration with dam height is examined through the measurement of acceleration with dam height. Finally, the purpose of this study is to evaluate seismic safety of "D" dam in operation. From the results of acceleration measurement, it was found that acceleration of dam crest was amplified about 1.52 times compared to the acceleration of dam bottom and amplification phenomenon is outstanding at three quarters of dam height from the bottom of dam. From the analysis of displacement behavior, it was estimated that vertical displacement of prototype dam is 6.8cm (0.1% of dam height) and horizontal displacement 12.3cm(0.2% of dam height). These percentages is much lower than 1% of dam height(general stability criteria). Therefore, it was concluded that seismic stability of "D" dam against an estimated earthquake is guaranteed.

  • PDF

혈관조영장비의 테이블-피사체간 거리 변화에 따른 혈관측정 정확도 연구 (Study on the Accuracy of Vessel Measurement According to Table Object Distance Changes)

  • 김승기
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.435-440
    • /
    • 2019
  • This is to study the accuracy of the actual size according to the TOD(table object distance; TOD) change when measuring blood vessels using angiography equipment, and to help the optimal selection of the device used accordingly. Balls similar to the size of common vessels were calibrated with TOD using 30 mm, 20 mm, 10 mm, 5 mm and acrylic phantoms, catheter calibration from 0 cm to 10 cm, 20 cm and 30 cm, respectively. It was measured whether there was a change in the measured value according to the change. The equipment used was GE Innova 3131 IQ equipment, and the image reconstruction method was GE AW4.7 post processing program. Two radiotechnologists were scanned three times by catheter calibration method and 3DRA(3dimension rotational angiography; 3DRA) volume rendering method. The independent sample T-test showed 0.981 (p> 0.05) to verify the significance between the two observers. As a result, in case of catheter calibration, the error rate at TOD 0 mm and 10 mm is within ± 10%, but when the TOD is changed to 20 mm and 50 mm respectively, the tolerance is ± 10% except for 30 mm ball exceeded. On the other hand, 3DRA was included within the tolerance range of ± 10% overall even when the TOD was changed from 0 mm to 50 mm. In the catheter calibration method, the larger the TOD, the larger the error range, and the 3DRA method was able to measure vascular vessels accurately close to the actual measurement without any consideration of the TOD.

근접치료동위원소의 Activity Check (The Activity Check of Brachytherapy Isotope)

  • 김건오;이병구;권영호
    • 대한방사선치료학회지
    • /
    • 제16권1호
    • /
    • pp.21-27
    • /
    • 2004
  • 목적 : 근접치료에 사용하는 동위원소인 Ir-192는 전량 수입에 의존하고 있으며, 그 Activity는 Welltype Chamber를 이용하여 측정하거나 제조업체의 선원 강도 인증서를 믿고 의존하는 방법, 또는 Farmer Chamber를 이용한 in-air dosimetry 등이 있다. 본 논문에서는 좀더 간단하고 단순한 Farmer Chamber를 이용한 방법을 소개하고자 한다. 대상 및 방법 : Farmer Chamber와 Source Calibration jig를 이용하여 Ir-192 동위원소의 Activity를 측정하고 그 값을 제조사의 선원강도 인증서의 값과 비교하여 선원의 Activity를 check한다. 결과 : 측정결과 제조사의 값과 비교하여 ${\pm}2.1\%$로, AAPM 권고 값인 ${\pm}5\%$ 안의 오차범위에 들어가는 차이로서 임상에서의 사용이 가능하다. 결론 : 근접치료장치의 사용증가와 그에 따른 선원의 수입 증가는 불가결하다. 그리고 선원의 정확한 Activity Check는 필수이다. 선원의 Act check를 위해 Well type chamber의 추가 구입 없이 Farmer Chamber와 Source Calibration jig를 이용하여 정확한 선량 측정이 가능하였다.

  • PDF

회절격자 간섭계를 이용한 초정밀 스테이지의 6 자유도 운동 특성 측정 (Measurement of a Six-degree-of-freedom Dynamic Characteristics using Angle Sensor-Implemented Grating Interferometry)

  • 이차범;김규하;이선규
    • 한국정밀공학회지
    • /
    • 제29권8호
    • /
    • pp.906-912
    • /
    • 2012
  • This paper presents the new method for a six-degree-of-freedom (DOF) motion measurement and those dynamic characterizations in an ultraprecision linear stage using angle sensor-implemented grating interferometry. It consists of a diffractive optical element, a corner cube, four separate two-dimensional position sensitive detectors, four photodiodes and auxiliary optics components. From the previous study, it was confirmed that the proposed optical system could measure a six-DOF motion error in a linear stage. In this article, six-DOF motion dynamic characteristics of the stage were investigated through the step response and with respect to the conditions with a different speed of a slide table. As a result, the natural frequency and damping ratio according to a six-DOF direction was obtained. Also, it was seen that the speed of slide table had an significant effect on a six-DOF displacement motion, especially, X, which was considered as the effect of friction mechanism and local elastic mechanical deformation in a slide guide.

A model experiment of damage detection for offshore jacket platforms based on partial measurement

  • Shi, Xiang;Li, Hua-Jun;Yang, Yong-Chun;Gong, Chen
    • Structural Engineering and Mechanics
    • /
    • 제29권3호
    • /
    • pp.311-325
    • /
    • 2008
  • Noting that damage occurrence of offshore jacket platforms is concentrated in two structural regions that are in the vicinity of still water surface and close to the seabed, a damage detection method by using only partial measurement of vibration in a suspect region was presented in this paper, which can not only locate damaged members but also evaluate damage severities. Then employing an experiment platform model under white-noise ground excitation by shaking table and using modal parameters of the first three modes identified by a scalar-type ARMA method on undamaged and damaged structures, the feasibility of the damage detection method was discussed. Modal parameters from eigenvalue analysis on the structural FEM model were also used to help the discussions. It is demonstrated that the damage detection algorithm is feasible on damage location and severity evaluation for broken slanted braces and it is robust against the errors of baseline FEM model to real structure when the principal errors is formed by difference of modal frequencies. It is also found that Z-value changes of modal shapes also play a role in the precise detection of damage.

Passive 3D motion optical data in shaking table tests of a SRG-reinforced masonry wall

  • De Canio, Gerardo;de Felice, Gianmarco;De Santis, Stefano;Giocoli, Alessandro;Mongelli, Marialuisa;Paolacci, Fabrizio;Roselli, Ivan
    • Earthquakes and Structures
    • /
    • 제10권1호
    • /
    • pp.53-71
    • /
    • 2016
  • Unconventional computer vision and image processing techniques offer significant advantages for experimental applications to shaking table testing, as they allow the overcoming of most typical problems of traditional sensors, such as encumbrance, limitations in the number of devices, range restrictions and risk of damage of the instruments in case of specimen failure. In this study, a 3D motion optical system was applied to analyze shake table tests carried out, up to failure, on a natural-scale masonry structure retrofitted with steel reinforced grout (SRG). The system makes use of wireless passive spherical retro-reflecting markers positioned on several points of the specimen, whose spatial displacements are recorded by near-infrared digital cameras. Analyses in the time domain allowed the monitoring of the deformations of the wall and of crack development through a displacement data processing (DDP) procedure implemented ad hoc. Fundamental frequencies and modal shapes were calculated in the frequency domain through an integrated methodology of experimental/operational modal analysis (EMA/OMA) techniques with 3D finite element analysis (FEA). Meaningful information on the structural response (e.g., displacements, damage development, and dynamic properties) were obtained, profitably integrating the results from conventional measurements. Furthermore, the comparison between 3D motion system and traditional instruments (i.e., displacement transducers and accelerometers) permitted a mutual validation of both experimental data and measurement methods.

볼스크류 전구간 피치오차 측정시스템 (Precision Measurement System forBall Screw Pitch Error)

  • 박희재;김인기
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.279-285
    • /
    • 1993
  • This paper presents a precision automatic measuring system for ball screw Pitch. Ball screw is mounted on a precision indexing table, and the ball screw pitch is measured via magnetic scale, where the indexing and measurement are performed by a PC. For precision indexing of ball screw, direct driven motor is coupled to the designed dead and live centers; the performance of the centers are assessed with a precision master sylinder,such as radial motion,tilt motion, and axial motions. An error compensation model is constructed for the measurement system of ball screw pitch, where the error motions of indexing system as well as the scale measurement system are combined to give the measurement error for the ball screw. The developed system proposes an automated precision measurement system for manufacturers and users of ball screw.

  • PDF

입원환자(入院患者) 영양관리(營養管理)와 식사치료효과(食事治療?果)에 관(關)한 연구(硏究) (제I보)(第I報) -Sodium 양제한식이(量制限食餌)에 관(關)하여- (Studies on the Special Diet for In-patients (Part I) -On the Sodium Restricted Diet-)

  • 임인순;현기순
    • Journal of Nutrition and Health
    • /
    • 제2권4호
    • /
    • pp.155-165
    • /
    • 1969
  • This experiment was conducted from the latter part of June through the first part of October 1969 by picking up 30 among the patients hospitalized at the department of internal medicine of the Seoul National University Hospital, who were under low sodium diet fording. By applying 1,000mg sodium diet that the author invented for feeding, the result of measurement made daily on 24 hours urine sodium shows an average of 58.1 mEq/L (average 76.799mEq/24hr). The sodium restrict diet menu (Table 4 and Table 5) was made due to table for food exchange list by American Heart Association and especially the 3 and 4, sample meal plan was applicable to that of Korean.

  • PDF