• Title/Summary/Keyword: Measurement Table

Search Result 453, Processing Time 0.03 seconds

The Effect of the Serum Progesterone and Estradiol Levels of hCG Administration Day on the Pregnancy and Fertilization Rate in IVF-ET Patients (체외수정 과배란 유도에서 hCG 주사 당일의 혈청 Progesterone과 Estradiol 농도가 수정율 및 임신율에 미치는 영향에 관한 연구)

  • Lee, Eun-Sook;Lee, Sang-Hoon;Bae, Do-Hwan
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.23 no.1
    • /
    • pp.51-59
    • /
    • 1996
  • Controlled Ovarian hyperstimulation(COH) is generally used to obtain synchronous high quality oocytes in in vitro fertilization-embryo transfer(IVF-ET). Many investigators have studied the relationship between serum hormone levels and outcomes of IVF-ET because there is no accurate estimation method of oocyte quality. Early premature luteinization of follicles before oocyte retrieval is the most troublesome problem in COH for IVF-ET. Gonadotropin-releasing hormone agonists(GnRH-a) are used as adjuncts with gonadotropins for COH in patients undergoing in IVF. The possible benefits of GnRH-a pretreatment include improving oocyte quality, allowing a more synchronous cohort of follicles to be recruited, and preventing premature lueinization hormone surges. In COH of IVF cycles, we investigated whether an elevated progesterone(P4) level on the day of human chorionic gonadotropin(hCG) administration indicates premature luteinization and is associated with a lower fertilization rate. Many investigators have studied that the lower fertilization rates seen in patients with elevated P4 levels might result from an adverse effect of P4 on the oocytes. We hypothesizes that serum P4 levels around the day of hCG may be helpful prediction of out come in IVF-ET cycles. Success rates after COH of IVF-ET cycles are dependent upon many variable factors. Follicular factors including the number of follicles, follicular diameters and especially serum estradiol(E2) levels as an indirect measurement of follicular function and guality have been thought to influence the outcomes of IVF-ET. To assess whether serum P4 and E2 levels affect the fertilization and pregnancy rate, we reviewed the stimulation cycles of 113 patients (119 cycles) undergoing IVF-ET with short protocol with GnRH-a, from March 1993 to August 1994 retrospectively. The serum P4 and E2 levels were compared on the day of hCG in the pregnant group, 45 patients(47 cycles) and in the non-pregnant group, 68 patients (72 cycles) respectively. The serum E2 level in non-pregnant group was $1367{\pm}875.8$ pg/ml which was significantly lower than that of pregnant group, $1643{\pm}987.9$ pg/ml( p< 0.01 ). And the serum P4 level in non-pregnant group was $2.1{\pm}1.4$ ng/ml which was significantly higher than that of pregnant group, $1.0{\pm}0.7$ ng/ml( p< 0.001 ). The fertilization rate was $61.3{\pm}21.3%$ in pregnant group which was higher than that of non-pregnant group, $41.1{\pm}20.2%$ (p< 0.01). We suggest that the serum levels of P4 and E2 on the day of hCG administration are additional parameters that predict the outcomes of IVF-ET cycles.

  • PDF

A Study of the Housework Hours and Fatigue Levels in Middle-aged Women (중년여성의 가사노동시간과 피로도에 관한 연구)

  • Park, Chai-Soon;Oh, Jeong-Ah;Suh, Soon-Rim
    • Women's Health Nursing
    • /
    • v.6 no.3
    • /
    • pp.398-412
    • /
    • 2000
  • The purpose of this study was to identify a relationship between housework hours and fatigue level in middle-aged women. The subjects were 204 women living in Seoul and near the city, ranging in ages of 30-59(mean = 41.6 year) and were interviewed during the month of Oct. to Dec. 1999. The following questionnaires were utilized in this study: a self reporting housework time measurement table and a fatigue symptom scale originated from Yoshitake (1978). The analysis of the data was done by SAS program, t-test, ANOVA, and Pearson correlation. The results of this study were as follows : 1. Total mean hours of housework of the subjects were shown 9.2 hours on weekdays and 8.9 hours on weekend. Mean hours according to the area of houseworks on weekdays and on weekend were preparing and providing meal 3.9 and 4.2, doing laundry and maintaining clothes 3.1 and 1.6, keeping and maintaining house 1.6 and 1.4, caring family 1.3 and 1.2, and keeping household records 0.5 both. 2. With respect to the general characteristics of the subjects, there were significantly difference in age, job, religion, type of family, number of children, experience of present and previous illness, and perceived body size. 3. Average fatigue scores of the subjects were 16.6 of total score 60. Fatigue scores by the area were neuroperceptive fatigue 6.5, mental fatigue 5.2, and physical fatigue 4.9 in order. There were significantly differences in the score of fatigue by religion, number of family, present illness, and perception of body size. 4. There were significantly positive relationships in the scores of fatigue with the total hours of housework, preparing and providing meal, doing laundry and maintaining clothes, keeping and maintaining house, and caring family. 5. The physical fatigue scores were positively related with the areas of preparing and providing meal, doing laundry and maintaining clothes. While the mental fatigue scores were positively related the areas of preparing and providing meal, caring family, and keeping and maintaining house, and neuroperceptive fatigue scores were positively related with the areas of keeping and maintaining house and caring family. The recommendations from this study were further studies to investigate how middle-aged women manage their fatigue level, increase public awareness of middle aged women's fatigue level, and develop programs for middle-aged women to help with high fatigue.

  • PDF

Fluoroscopic the equipment study in accordance with the entrance surface dose study of patients and practitioners (투시 검사 시 장비에 따른 환자와 시술자의 입사표면선량 연구)

  • Yang, Hae-Doo;Hong, Seon-Sook;Seong, Min-Sook;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.13-18
    • /
    • 2013
  • Purpose : Fluoroscopy equipment, depending on the type of changes that occur in the patient's position ESD and study the patient's scatter ray of ESD Practitioners considered a comparative analysis was to evaluate the correct dose. Materials and Methods : HITACHI four overtube type TU-8000 Flat Detector and Under tube C-Arm Philips' Multi Diagnost Eleva with Flat Detector type were measured by. Each devices is a measure of the patient's esd randophantom position in tabel unfors Xi multi funtion then fixed to the abdomen fluoroscopy and 10 seconds, spot was measured three times, practitioners of the incident surface dose by considering the patient's scatter ray of the table for each device in the average human stomach 21cm thickness acrylic phantom ($25cm{\times}25cm$) Place the practitioner position after position randophantom unfors Xi multi funtion in the thyroid and stomach 1 minute by a fixed one-time fluoroscopy and measured. Results : 10 seconds and the patient perspective of the c-arm ESD 1.2 times smaller on the AP and oblique measurements were measured in the 6-13 times smaller. spot positions to changes in the measured three times on the AP of the abdomen, ESD is 18 times smaller c-arm measurements and the oblique measurement was 19-30 times smaller. And 1 minute at practitioners fluoroscopy esd in the thyroid 2.12 times the c-arm, chest 1.75 times less the dose was measured. On the AP, depending on the device, but the lack of dose difference oblique positions of the two devices depending on changes in the area due to changes in both the AP than on the dose increased, the difference in dose between the two devices, the maximum difference was approximately 27 times. Conclusion : Fluoroscopic equipment at the time of inspection in accordance with changes in dose according to the patient and the patient's positions changes, because the area of the scatter ray considering the change of dose measurements be made, and study of the equipment according to the characteristics of the efficiency and the exposure of the patient and practitioner is considered smooth study equipment manufacturers that can be done is to build the system and think that is also important. Various fluoroscopy when you check future changes in many factors of change in dose for the equipment in the laboratory system by considering the scatter ray radiation shielding for the management to take advantage of reckless undertube have been utilized as more exposure Reduction activities can help is considered as the direction.

  • PDF

Development of Indentation Training System for Pulse Diagnosis (맥진 가압 트레이닝 시스템 개발)

  • Lee, Jeon;Lee, Yu-Jung;Jeon, Young-Ju;Woo, Young-Jae;Kim, Jong-Yeol
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.6
    • /
    • pp.117-122
    • /
    • 2008
  • Although the pulse diagnosis is the one of the most important diagnostic process to traditional medical doctors, there is no proper communication tool between experts and trainees. In this paper, we have developed a indentation training system which consists of a hardware measuring indent pressure on artificial arm quantitatively and a software providing a indentation training program. The hardware for measurement of indent pressure profile includes 3 load cells embedded in the artificial arm, signal amplification part and digitization part, NI-USB 6009 with 200Hz sampling rate. For setting up a relationship table between weights and output voltages, 8 standard weights were used. To evaluate this hardware, 3 oriental medical specialists were involved and their indent pressure profile were recorded three times respectively. From these, it was found that pulse diagnosis process could be divided into 3 periods and the maximum load were $500g{\cdot}f$ approximately while doctors perform a pulse diagnosis. The indentation training program was implemented with LabView and designed to monitor the differences between the pressure profile of a expert and that of a trainee so to offer some visual feedback to the trainee. Also, this program could provide the trends of training performances. With this developed system, the education of pulse diagnosis is expected to be more quantitative and effective.

A Study on the Intake-Balance of Iron, Copper and Cobalt of College Women in Korea (한국 여자 대학생의 Iron, Copper 및 Cobalt 평형에 관한 연구)

  • 장수영;최인선;오승호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.20 no.1
    • /
    • pp.78-88
    • /
    • 1991
  • In this study measured were daily intake and excretion of iron copper and cobalt of eight 21-23years old college women during four weeks by means of analyzing their food intake urine and feces while keeping their normal living pattern and maintenace of body weight. this is study also compared the actural meaurement value of iron intake by atomic absorption spectrophotometry with the conversion value of it by food table. The results were as follows. Daily mean intakes for iron copper and cobalt were $13.85{\pm}1.10mg/day,\;1.44{\pm}0.14mg/day\;and\;3.25{\pm}0.18mg/day$. Daily mean urinary excretions for iron copper and cobalt were $1.38{\pm}0.27mg/day\;0.06{\pm}0.01mg/day\;and\;0.59{\pm}0.07mg/day$. Daily mean fecal excretions for iron cop-per and cobalt were $7.66{\pm}0.79mg/day\;0.59{\pm}0.11mg/day\;and\;0.94{\pm}0.16mg/day$ The actual measurement value for iron intake was $13.85{\pm}1.10mg/day$ and its conversith value $15.26{\pm}1.17mg/day$ : the former was 9% than the latter.

  • PDF

Near Infrared Spectroscopy for Measuring Purine Derivatives in Urine and Estimation of Microbial Protein Synthesis in the Rumen for Sheep

  • Atanassova, Stefka;Iancheva, Nana;Tsenkova, Roumiana
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1273-1273
    • /
    • 2001
  • The efficiency of the luminal fermentation process influences overall efficiency of luminal production, animal health and reproduction. Ruminant production systems have a significant impact on the global environment, as well. Animal wastes contribute to pollution of the environment as ammonia volatilized to the air and nitrate leached to ground water. Microbial protein synthesis in the rumen satisfies a large proportion of the protein requirements of animals. Quantifying the microbial synthesis is possible by using markers for lumen bacteria and protozoa such as nucleic acids, purine bases, some specific amino acids, or by isotopic $^{15}N,^{32}P,\;and\;^{35}S$ labelled feeds. All those methods require cannulated animals, they are time-consuming and some methods are very expensive as well. Many attempts have been made to find an alternative method for indirect measurement of microbial synthesis in intact animals. The present investigations aimed to assess possibilities of NIRS for prediction of purine nitrogen excretion and ruminal microbial nitrogen synthesis by NIR spectra of urine. Urine samples were collected from 12 growing sheep,6 of them male, and 6- female. The sheep were included in feeding experiment. The ration consisted of sorghum silage and protein supplements -70:30 on dry matter basis. The protein supplements were chosen to differ in protein degradability. The urine samples were collected daily in a vessel containing $60m{\ell}$ 10% sulphuric acid to reduce pH below 3 and diluted with tap water to 4 liters. Samples were stored in plastic bottles and frozen at $-20^{\circ}C$ until chemical and NIRS analysis. The urine samples were analyzed for purine derivates - allantoin, uric acid, xantine and hypoxantine content. Microbial nitrogen synthesis in the lumen was calculated according to Chen and Gomes, 1995. Transmittance urine spectra with sample thickness 1mm were obtained by NIR System 6500 spectrophotometer in the spectral range 1100-2500nm. The calibration was performed using ISI software and PLS regression, respectively. The following statistical results of NIRS calibration for prediction of purine derivatives and microbial protein synthesis were obtained.(Table Omitted). The result of estimation of purine nitrogen excretion and microbial protein synthesis by NIR spectra of urine showed accuracy, adequate for rapid evaluation of microbial protein synthesis for a large number of animals and different diets. The results indicate that the advantages of the NIRS technology can be extended into animal physiological studies. The fast and low cost NIRS analyses could be used with no significant loss of accuracy when microbial protein synthesis in the lumen and the microbial protein flow in the duodenum are to be assessed by NIRS.

  • PDF

The application of Fourier transform near infrared (FT-NIR) spectroscopy in the wine industry of South Africa

  • Van Zyl, Anina;Manley, Marena;Wolf, Erhard E.H.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1257-1257
    • /
    • 2001
  • Fourier transform near infrared (FT-NIR) spectroscopy was used as a rapid method to measure the $^{o}Brix$ content and to discriminate between different must samples in terms of their fee amino nitrogen (FAN) values. FT-NIR spectroscopy was also used as a rapid method to discriminate between Chardonnay wine samples in terms of the status of the male-lactic fermentation (MLF). This was done by monitoring the conversion of malic to lactic acid and thereby determining whether MLF has started, is underway or has been completed followed by classification of the samples. Furthermore, FT-NIR spectroscopy was applied as a rapid method to discriminate between table wine samples in terms of the ethyl carbamate (EC) content. EC in wine can pose a health threat and need to be monitored by determining the EC content in relation to the regulatory limits set by the authorities. For each of the above mentioned parameters, $QUANT+^{TM}$ methods were built and calibrations derived and it was found that a very strong correlation existed in the sample set for the FT-NIR spectroscopic predictions of $^{o}Brix$ (r = 0.99, SECV = 0.306), but the correlations for the FAN (r = 0.61, SECV = 272.1), malic acid (r = 0.58, SECV = 1.06), lactic acid (r = 0.51, SECV = 1.14) and EC predictions (r = 0.47, SECV = 3.67) were not as good. Soft Independent Modeling by Class Analogy (SIMCA) diagnostics and validation was applied as a sophisticated discrimination method. The must samples could be classified in terms of their FAN values when SIMCA was applied, obtaining results with recognition rates exceeding 80%. When SIMCA diagnostics and validation were applied to determine the progress of conversion of malic to lactic acid and the EC content, again results with recognition rates exceeding 80% were obtained. The evaluation of the applicability of FT-NIR spectroscopy measurement of FAN, $^{o}Brix$ values, malic acid, lactic acid and EC content in must and wine shows considerable promise. FT-NIR spectroscopy has the potential to reduce the analytical times considerably in a range of measurements commonly used during the wine making process. Where conventional FT-NIR calibrations are not effective, SIMCA methods can be used as a discriminative method for rapid classification of samples. SIMCA can replace expensive, time-consuming, quantitative analytical methods, if not completely, at least to some extent, because in many processes it is only needed to know whether a specific cut off point has been reach or not or whether a sample belongs to a certain class or not.

  • PDF

Effects of Electroacupuncture on Parameters Related to Obesity in Adults with Abdominal Obesity:Three arm Randomized Single Blind Pilot Study (전침이 복부비만 성인의 비만관련 지표에 미치는 영향-무작위배정 단일 맹검 예비연구-)

  • Chung, Jie-Youn;Kim, Jong-In;Lee, Sang-Hoon;Kang, Sung-Keel
    • Journal of Acupuncture Research
    • /
    • v.27 no.6
    • /
    • pp.43-57
    • /
    • 2010
  • Objectives : To investigate the effects of electroacupuncture on parameters related to obesity in adults with abdominal obesity. Methods : A three arm randomized single blind pilot study was conducted from Jan 4 to March 25, 2010 in Kyung Hee Oriental Medical Hospital. The subjects were 39 adults with abdominal obesity and were randomly divided by computer generated random table into 3 groups; EA(electroacupuncture), sham EA(sham electroacupuncture) and waitlist groups. Acupuncture points located at abdomen($CV_{12}$, $CV_6$, $ST_{25}$, $SP_{15}$, $SP_{14}$) and extremities($LI_4$, $LI_{11}$, $ST_{36}$, $ST_{44}$) were inserted by disposable stainless steel needles and were stimulated 30 minutes with 24Hz, 0.27~1.3mA(tolerable strength), asymmetric biphasic continuous pulse wave form by STN-111 Stratek device in EA group. Two treatment sessions per week for 5 weeks(10 sessions in total) were done in EA and sham EA groups. The primary outcome measurement was WC(waist circumference), and the secondary outcome measurements included WHR(waist hip ratio), ASF(thickness of abdominal subcutaneous fat), and inbody measurements of BW(body weight), BMI(body mass index), BFR(body fat ratio) and VFA(visceral fat area), and also scores of BULIT-R(bulimia test revised), KoQoL(Korean obesity of QoL) and BSQ(body shape questionnaire). Results : All of 39 subjects were included in ITT(intention-to-treat) analysis. There were significant reductions in WC, WHR and ASF after 5-week electroacupuncture treatments and the percentage reductions were significantly greater than sham EA or waitlist group. There were no significant differences between groups in percentage reductions of other parameters(BW, BMI, BFR, VFA, BULIT-R, KoQoL and BSQ). But, there were continuous reductions in BW, BMI, BFR and VFA at 3 weeks after the end of treatment and there was significant reduction in BW compared with the baseline value in EA group. No seriously adverse effects were reported during the period. Conclusions : Electroacupuncture was more effective than sham electroacupuncture or no intervention on the reduction of WC, WHR and ASF in adults with abdominal obesity.

A Study on the Nutritional Assessment of Early Childhood Using Mid-Upper-Arm Circumference (상박위(上膊圍)에 의(依)한 성장기(成長期) 아동(兒童)에 영양상태(營養狀態)의 판정(判定)에 관(關)한 연구(硏究))

  • Tchai, B.S.;Nam, Y.K.;Chung, Y.J.
    • Journal of Nutrition and Health
    • /
    • v.8 no.4
    • /
    • pp.9-14
    • /
    • 1975
  • Growth retardation and a variable degree of body disproportion are recognized features of malnutrition, and mild and moderate protein-calorie malnutrition(PCM). Among the various body measurements suggested to assess the prevalence of all grades of PCM as judged by growth retardation and by body disproportion, the 'mid-upper-arm circumference'-abbreviated to 'arm-circumference' has been suggested as a potential useful simple field index for the assessment of PCM showing that the measurement would give composite information simultaneously on three important effects on PCM-deficit in the muscle protein reservoirs, availability of calorie stores in the form of subcutaneous fat, and growth failure. And this is selected because of its easy accessibility, and less involvement with clinical edema. This study is conducted to make a comparison between the percentage of Korean weight for age standards and the percentage of mid-upper-arm circumference for age standards of 175 preschool children aged $3{\sim}72$ months who are selected among the low-income residents in Seoul. In this study, a comparison is made between the results obtained by expressing the observed weight of the child as a percentage of Korean standard, referred to as 'weight-for-age' and the observed arm-circumference expressed as a percentage of the age-specific arm standard of Jelliffe, referred to as 'arm-for-age'. All the measurements were taken following the techniques described by Jelliffe. The left mid upper arm was measured using a glass-fibre tape and the Fairbanks Morse beam balance was used for weighing. 80% level of weight for age Korean standard and 85% level of arm for are Jelliffe standard were used as an upper borderline limit for PCM. Comparing the 80% weight-for-age and the 85% arm-for-age standard as an upper limit for PCM, for children aged $3{\sim}72$ months, results in 84.6% agreement with the sensitivity of 86.4% and its specificity of 83.5%. If arm circumference alone had been measured and judgement made on this basis, then only 5.1% of the children would have been 'wrongly' classified. And there is a moderately close correlation between arm circumference and weight for age as the data in Table 4 shows. The problem therefore lies in the standard for arm circumference in normal children and in determining what is the lower limit of normal. Once this is clearly difined, one can rely more confidently on arm circumference measurements alone for the nutritional assessment of early childhood.

  • PDF

Measurement of ROI Temperature in Herniation of Intervertebral Disc Patients Using DITI (디지털 적외선 체열진단기를 이용한 추간판탈출증 환자의 ROI 온도측정)

  • Park, Jeong Kyu;Park, Jong Sam;Kwon, Soon Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.273-278
    • /
    • 2017
  • Among 45 patients of herniation of intervertebral disc with $L_4$ to $L_5$ herniation, who underwent infrared thermography, the number of female was larger than male and the age of 50s was highest. From the results measured from the distribution table, we have confirmed that there was no significant difference depending on sex and age (p> 0.05). The region of the highest ROI temperature for patients with $L_4-L_5$ intervertebral disc prolapse was the back of the posterior right tibia, and followed by the back of the left shin bone-below the front right knee-below the front left knee. There was a significant difference depending on the measured site. The average ROI temperature for patients was $30.30{\pm}0.50$ whereas that for normal persons was $31.20{\pm}0.58$, yielding the temperature difference of $0.66{\pm}0.59$ between the two groups. The ROI of patients was lower than $31.20{\pm}0.58$ (p <0.05) because the significance of the sample, which has been obtained from the results of a sample t-test, was less than 0.05 (p <0.05). From further researches, it may necessary to develope the methodology for correcting data regarding thermal environment and, in addition, to develope a new thermal index based on it. Therefore, we can confirm that pre-treatment for infrared thermography is very important in order to minimize the procedure for correcting data. It is required that radiologists who inspect disc herniations should carefully observe and consider the patients during their measurements.