• Title/Summary/Keyword: Measurement Table

Search Result 453, Processing Time 0.031 seconds

Application of a Multi-Level Rotating Table for Strawberry Sorting and Packing (딸기 선별 및 포장작업의 자세개선을 위한 다층회전형 작업대 적용)

  • Park, Sung-Ha
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.34 no.1
    • /
    • pp.97-102
    • /
    • 2011
  • This study was performed to design and develop an ergonomic equipment for strawberry sorting and packing in agricultural working environments. Potential risk of work related musculo-skeletal disorders associated with farm workers performing strawberry sorting and packing was analyzed through interviews, field surveys, work measurement, and working posture evaluation. For the evaluation of working posture, we used REBA, OWAS, and RULA assessment methods to identify multi-factorial risk factors. Based on the result of comprehensive assessment, a new concept of multi-level rotating table for strawberry sorting and packing was proposed to modify awkward working postures and improve the effectiveness of the farm work. Finally, the characteristics and effectiveness of new equipment was discussed in terms of improvements in productivity, safety, and subjective ratings of farm workers. The results of analysis showed that working conditions improved significantly.

A study of isometric position of the knee during anterior cruciate ligament reconstruction (전십자 인대 재건시 등장위치에 관한 연구)

  • 박정홍;손권;김광훈;문병영;서정탁
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.158-161
    • /
    • 2004
  • The isometric position of the anterior cruciate ligament was calculated during flexion-extension. Flexion-extension motion data of the knee joint were obtained by Fastrak, a three-dimensional motion measurement system. A subject was seated on a flat table and the tibia sensor position was measured with the femur fixed at the table. A three-dimensional knee model was constructed using a graphic tool to simulate the knee motion. Three surgical positions of the femoral tunnel were selected and the distances between the determined tibial tunnel and each femoral tunnel were calculated. The maximum elongation position was found to be in the ten thirty direction of clock.

  • PDF

A New Model of Magnetic Force in Magnetic Levitation Systems

  • Lee, Y.S.;Yang, J.H.;Shim, S.Y.
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.584-592
    • /
    • 2008
  • In this paper, we propose a new model of the magnetic control force exerted on the levitation object in magnetic levitation systems. The model assumes that the magnetic force is a function of the voltage applied to an electromagnet and the position of a levitation object. The function is not explicitly expressed but represented through a 2D lookup table constructed from the experimentally measured data. Unlike the conventional model that reveals only local characteristics of the magnetic force, the proposed model shows global characteristics satisfactorily. Specially devised measurement equipment is utilized in order to gather the data required for model construction. An experimental procedure to construct the model is presented. We apply the proposed model to designing a sliding mode controller for a lab-built magnetic system. The validity of the proposed model is illustrated by comparing the performances of the controller adopting the conventional model with that of the controller adopting the proposed model.

A Study on the Positioning Accuracy and table Deflection by Load (하중에 의한 위치결정오차와 테이블 처짐에 관한 연구)

  • 전언찬
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.6
    • /
    • pp.98-104
    • /
    • 1999
  • As the accuracy of manufactured goods needed high accuracy processing has made the efficiency of NC and measurement technology development, the innovation of machine tools has influence the development of the semi-conductor and optical technology. The movement errors can be expressed in terms of yaw, roll an pitch etc. In the case of expanding the error range, static, dynamic and servo gain errors can be included. Machining center might have twenty-one movement errs including three types of joint errors. Those errors have been measured on the condition of just loading of standard table. Regarding these measuring methods, the mechanical compliance of the structure has not been considered. In this paper, therefor, the influences of the additional load on the positioning accuracy are investigated. The results and the techniques proposed in this study can be considered very effective and useful to compensate more correctly the positioning motion.

  • PDF

Precision Position Control for PCB Screen Printer Using Image Processing (화상처리를 이용한 PCB 스크린 인쇄기의 정밀위치제어)

  • 이근유;부이트롱휴;김동규;박순실;김상봉
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.295-295
    • /
    • 2000
  • In this paper, the measurement algorithm of PCB alignment error is developed using image processing. The X-Y-$\theta$ table correcting PCB alignment error is driven by drive module based on microprocessor according to calculation results obtained through image processing procedure. In order to recognize the X-Y-$\theta$ position errors, two fiducial points are marked on PCB and two cameras of ultraviolet rays types are used for detection of the points to capture exactly fiducial points under disturbance of illumination change. Through application for a practical screen printer, the precision control using the developed position control system can be realized about 2.5${\mu}{\textrm}{m}$ in table moving range and 8${\mu}{\textrm}{m}$ in camera processing precision.

  • PDF

Development of Wire Clamping Transfer Mechanism for Tapered Helical Shape (테이퍼진 나선가공 연삭기를 위한 와이어 클램핑 이송기구의 개발)

  • Eun, Suin;Maeng, Heeyoung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.2
    • /
    • pp.257-261
    • /
    • 2017
  • Drilling file is medical mini-drill which is made of Ni-Ti material and has tapered shape. It's for removing teeth nervine which helps the endodontic treatment. All files, saled at domestic market, are imported from U.S. and Europe. Also they have low manufacturing efficiency and high price because it is made by universal 5 axis CNC grinding machine. To solve these problem, 3 axis CNC table, controllable tilting angle spindle and helix angle moving table are devised. To confirm divised CNC grinding machine's manufacturing accuracy, conveying amount and finish product size measurement expreiment has been practiced. Also to automate all manufacturing processes, automatic mechanism is designed.

An Analysis of Performance Error of Roundness Measuring Instrument -by phase different method- (眞圓度 測定器의 誤差特性에 대한 解析 -위상차법-)

  • 한응교;허문석;박익근
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.31-37
    • /
    • 1988
  • A phase different method to evaluate the instrument error of roundness measuring instrument and the form error of specimens for the calibration of the instrument is used. An instrument with a rotary table supported by an air bearing was calibrated by using the standard balls as a standard. The calibration was carried out repeatedly by setting the same ball in 12 phase angles(per 30.deg.) on the table and by recording their roundness errors with a magnification of 100,000 times. As a result of data analysis of all the observations, readout at each of 144 orientations(per 2.5.deg.) from recorded data file, the error of performance of the instrument and the specimens are separated. In the particular instrument used in the present experiment, the error of the instrument was determined with the accuracy of 0.0164 (.mu.m) and the form error of the specimens was determined with the accuracy of 0.0264,0.0172(.mu.m), respectively. If the instrument was calibrated by using the above specimens, then the accuracy of the measurement of roundness error can be improved to about 0.017 (.mu.m).

  • PDF

In-situ Monitoring of Matric Suctions in a Weathered Granite Soil Slope (풍화화강토 사면에서 강우로 인한 모관흡수력 변화에 대한 실험 연구)

  • 이인모;조우성;김영욱;성상규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.509-516
    • /
    • 2002
  • Rainfall-induced landslides in a weathered granite soil slope have mostly relative shallow slip surfaces above the groundwater table The pore-water pressure of soil above the groundwater table is usually negative. This negative pore-water pressure(or matric suction) has been found to make a large contribution to the slope stability. Therefore, the variation of in-situ matric suction profiles with time in a soil slope should be understood. In this study, a field measurement program was carried out from June to August, 2001 to monitor in-situ matric suctions and volumetric water contents in a weathered granite soil slope. The influence of climatic conditions on the variation of in-situ matric suctions could be found to decrease rapidly with depth. It could be found that decrement of matric suction induced by precipitation is affected not only by the amount and duration of rainfalls but also by the initial matric suction just prior to rainstorms. The soil-water characteristic from the field monitoring tends toward the wetting path of SWCC obtained from the laboratory test.

  • PDF

A Study of Gage R&R Analysis Considering the Variations of Between-Within Group and Within Part (군간-군내-부품내 변동을 고려한 Gage R&R 분석에 관한 연구)

  • Lee, Seung-Hun;Lee, Chang-U
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2005.05a
    • /
    • pp.975-982
    • /
    • 2005
  • The purpose of the Gage R&R study is to determine whether a measurement system is adequate for monitoring a process. If the measurement system variation is small relative to the process variation, then the measurement system is deemed 'adequate'. The sources of variation associated with the measurement system are compared using an analysis of variance (ANOVA) model, in general. A typical ANOVA model used in a standard Gage R&R study is the two-factor random effect model. Then, the ANOVA partitions the total variation into three categories: repeatability, reproducibility, part variation. However, if the process variation possesses the between group variation, within group variation, and within-part variation, these variations can cause the measurement system evaluation to provide misleading results. That is, in the standard Gage R&R study these variations affect the estimate of repeatability, reproducibility, or both. This paper presents a four-factor nested factorial ANOVA model which explicitly considers these variations for the Gage R&R study. The variance component estimates are derived by setting the EMS equations equal to the corresponding mean square from the ANOVA table and solving. And the proposed model is compared with the standard Gage R&R model.

  • PDF

A Study of Gage R&R Analysis Considering the Variations of Between-Within Group and Within Part (군간-군내-부품내 변동을 고려한 Gage R&R 분석에 관한 연구)

  • Lee, Seung-Hoon;Lee, Chang-Woo
    • IE interfaces
    • /
    • v.18 no.4
    • /
    • pp.444-453
    • /
    • 2005
  • The purpose of the Gage R&R study is to determine whether a measurement system is adequate for monitoring a process. If the measurement system variation is small relative to the process variation, then the measurement system is deemed "adequate". The sources of variation associated with the measurement system are compared using an analysis of variance (ANOVA) model, in general. A typical ANOVA model used in a standard Gage R&R study is the two-factor random effect model. Then, the ANOVA partitions the total variation into three categories: repeatability, reproducibility, part variation. However, if the process variation possesses the between group variation, within group variation, and within part variation, these variations can cause the measurement system evaluation to provide misleading results. That is, in the standard Gage R&R study these variations affect the estimate of repeatability, reproducibility, or both. This paper presents a four-factor nested factorial ANOVA model which explicitly considers these variations for the Gage R&R study. The variance component estimators are derived by setting the EMS equations equal to the corresponding mean square from the ANOVA table and solving. And the proposed model is compared with the standard Gage R&R model.