• Title/Summary/Keyword: Measurement Scales

Search Result 347, Processing Time 0.024 seconds

The Study of Korean -type Discountstore Service Quality Scales(KD-SQS) (한국형 할인점의 서비스품질 측정 척도에 관한 연구)

  • Rho, Eun-Jeong;Suh, Yong-Gu
    • Journal of Distribution Research
    • /
    • v.13 no.3
    • /
    • pp.127-154
    • /
    • 2008
  • For the large scale retailers such as chain discount stores and specialty stores, having measurement tool to maintain service quality can be very crucial to sustain high and same level of service qualities around multiple stores. This study aims to develop service quality scales of large-scale stores using Korean discount store cases. We have studied the previous service quality measures including RSQS(Retail Service Quality Scale) and have modified and developed our own scale model called KD-SQS(Korea Discount Service Quality Scale). The following six components have been revealed as the basic dimensions of service quality of Korean discount stores: basic benefits, promotion, personal interactions, physical aspects, policy and additional convenience. Our scales have been verified through various validity and reliability tests.

  • PDF

Development of the Integrated Control System for the Batch Plant in Field (배치 플랜트를 위한 통합 제어 시스템 개발)

  • Kim, Jung-Sook
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1081-1086
    • /
    • 2017
  • The measurement and control device which is for controlling the best mixture rate is needed to produce the best quality concrete in Batch Plant. Present the workers do the measurement and control with each equipped devices such as a indicator, PLC and a scale. That is difficult to use especially for beginner in field. In this paper, we developed the integrated measurement and control system which is composed of hardware with PCB and software. It is easy to use for beginner worker in plant field.

Development of Automatic 3D Measurement System (3차원 자동 검사 시스템 개발)

  • Lee, Y.J.;Bae, J.I.;Hong, S.I.;Song, D.S.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2849-2850
    • /
    • 2000
  • We developed an automatic 3D inspection system. The system consists of two parts one includes hardwares such as actuators. linear scales and a probe. etc. the other involves softwares for management and control of the system. Compared with existing 3D measurement systems. this system achieved automatically the inspection. This automatic inspection makes the system have some advantages to reduce a measurement time and to be easily used by operators.

  • PDF

Development of Automatic 3D Measurement System for Molding Inspection (금형 부품 검사를 위한 3차원 측정기 개발)

  • Eom, S.I.;Lee, Y.J.;Song, D.S.;Bae, J.I.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3070-3072
    • /
    • 1999
  • We developed an automatic 3D inspection system. The system consists of two parts : one includes hardwares such as actuators, linear scales and a probe, etc. the other involves softwares for management and control of the system. Compared with existing 3D measurement systems, this system achieved automatically the inspection. This automatic inspection makes the system have some advantages to reduce a measurement time and to be easily used by operators.

  • PDF

Comparison of Visual Analogue Scale, Categorical Scale and Satisfaction for Postoperative Pain (수술 후 통증 평가를 위한 Visual Analogue Scale, Categorical Scale 그리고 환자 만족도와의 비교)

  • Kim, Yong-Ik;Nam, Sang-Goo;Hong, Seung-Taek;Kang, Kyu-Sik;Park, Wook
    • The Korean Journal of Pain
    • /
    • v.14 no.2
    • /
    • pp.156-163
    • /
    • 2001
  • Background: The categorical scales and visual analogue scales (VAS) are methods used for evaluating variations of postoperative pain intensity. Several studies have introduced the idea that there is a clear correlation between visual scales and categorical scales. However, when VAS is the only pain measure in the study, we do not know what point on the VAS represents a category on the categorical scale and their degree of correlation with satisfaction for postoperative pain. Methods: 252 patients who had undergone elective surgery were studied. A 5-point categorical scale (none, mild, moderate, severe, worst possible pain), a 0-100 mm VAS (no pain to worst possible pain) and patient satisfaction score were checked 24 hours after surgery using a pain questionnaire and VAS tool. Results: The mean VAS score of the 14 patients reporting 'no-pain' was $1.9{\pm}0.9$, $23.9{\pm}1.0$ for the 132 patients reporting 'mild-pain', $47.2{\pm}1.1$ for the 82 patients reporting 'moderate-pain' and $67.5{\pm}2.8$ for the 24 patients reporting 'severe-pain'. Of the patients reporting moderate pain, 85% scored over 45.6 mm on the corresponding VAS, with a mean score 47.2 mm. The mean satisfaction scores were $90.6{\pm}2.7$ for the 'no pain', patients, $75.1{\pm}1.3$ for ‘mild pain', $58.3{\pm}1.5$ for 'moderate pain', and $55.1{\pm}4.0$ for 'severe pain' patients. The categorical scale was significantly correlated with VAS (P < 0.01). The satisfaction score was significantly inversely correlated with VAS (P < 0.01). Conclusions: Our results indicate that if a patient records a VAS score in excess of 45.6 mm they would probably have recorded at least moderate pain on a 5-point categorical scale. The categorical scale can be used properly for postoperative pain measurement with VAS. More research is required for the development of suitable pain descriptor for a categorical scale and pain questionnaire in Korean.

  • PDF

The Development of the Nursing Organization Culture Measurement tool (간호조직문화 측정도구 개발을 위한 연구)

  • Kim, Moon-Sil;Kim, Ji-Hyun;Han, Su-Jeong
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.10 no.2
    • /
    • pp.175-184
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a nursing organization culture measurement tool and to test the validity and reliability of the tool. Method: This study conducted in three phases. In phase 1, theoretical framework choice, Phase 2, measurement items selection, Phase 3, testing of validity and reliability. In order to test validity and reliability of the measurement, data were collected from 915 nurses, working in the 22 hospitals with more 500 beds. The data obtatined were analyzed by SPSS-Win 10.0 program using percentages, Factor Analysis, Cronbach's alpha Coefficients. Result: As a result of the study, nursing organization culture measurement scale was consisted of 20 items, 4 factors. 4 factor explained 60.54% of the total variance, and the Cronbach's alpha of this scale was .8829. Conclusions: The Study supports the validity and reliability of the scales. Therefore, this scale can be effectively utilized for the evaluation of nursing organization culture in hospital setting.

  • PDF

Assessment of DVC measurement uncertainty on GFRPs with various fiber architectures

  • Bartulovic, Ante;Tomicevic, Zvonimir;Bubalo, Ante;Hild, Francois
    • Coupled systems mechanics
    • /
    • v.11 no.1
    • /
    • pp.15-32
    • /
    • 2022
  • The comprehensive understanding of the fiber reinforced polymer behavior requires the use of advanced non-destructive testing methods due to its heterogeneous microstructure and anisotropic mechanical proprieties. In addition, the material response under load is strongly associated with manufacturing defects (e.g., voids, inclusions, fiber misalignment, debonds, improper cure and delamination). Such imperfections and microstructures induce various damage mechanisms arising at different scales before macrocracks are formed. The origin of damage phenomena can only be fully understood with the access to underlying microstructural features. This makes X-ray Computed Tomography an appropriate imaging tool to capture changes in the bulk of fibrous materials. Moreover, Digital Volume Correlation (DVC) can be used to measure kinematic fields induced by various loading histories. The correlation technique relies on image contrast induced by microstructures. Fibrous composites can be reinforced by different fiber architectures that may lead to poor natural contrast. Hence, a priori analyses need to be performed to assess the corresponding DVC measurement uncertainties. This study aimed to evaluate measurement resolutions of global and regularized DVC for glass fiber reinforced polymers with different fiber architectures. The measurement uncertainties were evaluated with respect to element size and regularization lengths. Even though FE-based DVC could not reach the recommended displacement uncertainty with low spatial resolution, regularized DVC enabled for the use of fine meshes when applying appropriate regularization.

Relationship between Status Type of Sociometric Measurement and Korean Personality Test for Children (사회성측정 지위 유형과 한국 아동 성격검사와의 관계)

  • Lee, Meung-Sook;Ahn, Ie-Hwan;Hong, Sang-Hwang
    • The Korean Journal of Elementary Counseling
    • /
    • v.11 no.3
    • /
    • pp.391-405
    • /
    • 2012
  • The purpose of this study is to discover unique personality traits which the children of 5 social status types using 10 clinical scales of Korea Children's personality test (KCPI-S) in order to define the characteristics of 5 social status types developed as the Korean type. For this purpose, two hypotheses were set and tested. The subjects of this study were 502 children who were 4, 5th and 6th grade elementary school boys and girls in A city. 5 social status types and gender of children were set as the independent variables each, and 10 clinical scales of Korea Children's personality test as the dependent variables. The research hypotheses were analyzed in turn by the multivariate analysis (MANOVA) and t-test. The results are as follows: First, the results of analyzing differences in 10 clinical scales in accordance with 5 social status types how the significant differences in all 9 clinical scales except for language development scale, and ${\eta}^2$ representing the explanatory power of the independent variables to dependent variables was found to be in the range of the lowest at 2% up to 10% for each scale. Second, the results of analysis of the gender difference show that in the case of the children with controversial and neglected children, the significant difference was appeared between boys and girls in 8-9 scales among the 10 clinical scales, but in the case of rest 3 social status types (average, popular, rejected children) the difference was appeared between boys and girls only in 2-3 scales. Depending on these results it seems that each of 5 social status types of the children has its own unique personality structure. It is necessary to attend to the fact that in the case of the children with controversial and neglected children, the average value of boys are significantly higher than that of the girls. There is a big possibility that the boys have more psychological problems that the girls. It is judged that in case of these two types the personal traits applying gender should be interpreted. Therefore, the follow-up study should conduct the exploratory research on the structure of the relationship between children's language development and sociality measure. Further, it is necessary to conduct the psychological comparison between genders in the children with controversial and neglected children, and to study the structure of their relationship with rest social status types by genders.

  • PDF

2D genus topology of 21-cm differential brightness temperature during cosmic reionization

  • Ahn, Kyung-Jin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.46.2-46.2
    • /
    • 2011
  • Planck is already in active operation, and in a few years a detailed CMB anisotropy map will be compiled, surpassing WMAP both in temperature and polarization. The E mode - E mode autocorrelation power spectrum at large scales contains weak but sizable information on the history of cosmic reionization. We show our latest advance of our own simulation of cosmic reionization that incorporates Pop III stars, and provide a forecast for Planck polarization measurement.

  • PDF

Ne-Ne 레이저의 간섭을 이용한 고정밀 리니어 스케일의 제작에 관한 연구

  • 전병욱;박두원;이명호;한응교
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.176-194
    • /
    • 1991
  • A study on the Manufactiring of High-Precision Linear Scale by the Use of He-Ne Laser Interference Of late, along with the advancement of procision machining technology, the reauirement of super-precision measurement increases as time goes on, and the precision and accuracy of standard scale which is a basis of procision measurement has been cognized as a oriterion of industrial development in a nation. Up to now, mechanical and chemical methods have been widely employed to carve scale lines on linear scale, and it is impossible for the linear scale manufactured by means of those methods to guarantee the measurement with sub-micron level owing to errors attended with various problems. And the measuring length also bears errors subjected to the influence of surroundings condition, and shows inefficient circumstances in measurement on the ground of the complexity of measuring procedure as well as massive measuring apparatus. Hence in this paper, we described on technology by which we can carve scale lines thru optical method under the condition of laboratory by using rhcoherence of He-Ne two-mode stabilized laser and in turn, put it to practical use as linear scale for the measurment of lengrh. In this researchin the case of setting scale interval to 20 .mu. m, we employed super-precision scale-carving device associated by Ar larser and acoustic optical modulator in lieu of flsahing lamp scale-carving device, and we consequently obtained superior linear scales carved with precision and accuracy of .+-. 0.3 .mu. m.