• 제목/요약/키워드: Measurement Program

검색결과 2,492건 처리시간 0.031초

프로그램 교육목표 평가 모형과 성취도 측정에 관한 연구 (A Study on the Measurement of Performance and Evaluation Model to Achieve the Program Education Objectives)

  • 박익수;박경우
    • 공학교육연구
    • /
    • 제16권6호
    • /
    • pp.52-57
    • /
    • 2013
  • In this paper, the evaluation system in order to achieve the program education objectives of Accreditaion Board for engineering education of Korea, analyze the educational objectives evaluation tool case studies of programs that are run by each university, the program educational objectives to match the actual situation of university I have developed a distinction between questions the evaluation and assessment system. Configuration, execution, measurement, analysis, is a five-step mooring, the evaluation tool, is a graduate research you are currently using the most in Korea, the employer survey, education target assessment model of the program, employment trends of graduates, I decided to graduate focus group interviews. Distinction between questions, the evaluation also developed a questionnaire to derive the important keywords of education for each objectives. Improvement evaluation tool, the evaluation criteria is required, the University is preparing evaluate (NGR) in South Korea engineering education certification next regularly, requires research on semantic analysis of the results of measurement of the educational goals of the program in the future some.

DESIGN OF A VIBRATION AND STRESS MEASUREMENT SYSTEM FOR AN ADVANCED POWER REACTOR 1400 REACTOR VESSEL INTERNALS COMPREHENSIVE VIBRATION ASSESSMENT PROGRAM

  • Ko, Do-Young;Kim, Kyu-Hyung
    • Nuclear Engineering and Technology
    • /
    • 제45권2호
    • /
    • pp.249-256
    • /
    • 2013
  • In accordance with the US Nuclear Regulatory Commission (US NRC), Regulatory Guide 1.20, the reactor vessel internals comprehensive vibration assessment program (RVI CVAP) has been developed for an Advanced Power Reactor 1400 (APR1400). The purpose of the RVI CVAP is to verify the structural integrity of the reactor internals to flow-induced loads prior to commercial operation. The APR1400 RVI CVAP consists of four programs (analysis, measurement, inspection, and assessment). Thoughtful preparation is essential to the measurement program, because data acquisition must be performed only once. The optimized design of a vibration and stress measurement system for the RVI CVAP is essential to verify the integrity of the APR1400 RVI. We successfully designed a vibration and stress measurement system for the APR1400 RVI CVAP based on the design materials, the hydraulic and structural analysis results, and performance tests of transducers in an extreme environment. The measurement system designed in this paper will be utilized for the APR1400 RVI CVAP as part of the first construction project in Korea.

개방형 CNC를 응용한 하이브리드 머신 개발 (Hybrid Machine with Open Architecture Controller)

  • 김선호;김동훈;박정환;고태조;구태중
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.338-342
    • /
    • 2003
  • Hybrid machine is based on hardware technologies of machine tool and software technologies of open architecture controller. In machining technology, combination technology of turning, milling, and grinding and in machining energy technology. combination of mechanical, electrical, and chemical technology are developed. This paper describes hybrid machine technology for combination of machining, on-machine measurement, on-machine CAM, and on-machine remote monitoring and control in open architecture controller environment. For on-machine measurement, non-contact measurement technology based on CAD information is developed. For on-machine CAM, interactive CAM program for automatic NC program generation and tool path simulation is developed. For generation on-machine remote monitoring and control, suitable interface method between web program and CNC is proposed. The developed hybrid machine technology is implemented in 3 axes milling machine for evaluation of operablity.

  • PDF

입체화상으로부터 3차원 마이크로계의 효과적인 깊이측정 (An Efficient Depth Measurement of 3D Microsystem from Stereo Images)

  • 황진우;이중;윤도영
    • 한국공작기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.178-182
    • /
    • 2007
  • This study represents the efficient depth measurement for 3-dimensional microsystems using the disparity histogram from stereo images. Implementation of user-friendly Windows program written in C++ involves the various methods for the stereo-image processing in which the minimization of matching-pixel error upon the unique point for stereo images was carried out as a pre-processing method. Even though MPC among various methods was adopted in the present measurement, the resulting measurements seem to require optimizations of the windows sizes and corrections of post-manipulation for stereo images. The present work using Windows program is promising to measure the 3-dimensional depth of micro-system efficiently in implementing the 3-dimensional structure of micro-systems.

Wall Thickness Measurement of Respiratory Airway in CT Images: Signal Processing Aspects

  • Park, Sang-Joon;Kim, Jong-Hyo;Kim, Kwang-Gi;Lee, Sang-Ho
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.279-280
    • /
    • 2007
  • Airway wall thickness is an important bio-marker for evaluation of pulmonary diseases such as stenosis, bronchiectasis. Nevertheless, an image-based analysis of the airway tree can provide precise and valuable airway size information, quantitative measurement of airway wall thickness in CT images involves various sources of error and uncertainty. So we have developed an accurate airway wall measurement technique for small airways with three-dimensional (3-D) approach. To illustrate performance of these techniques, we used airway phantom that consisted of 4 acryl tubes with various inner and outer diameters. Results show that evaluation of interpolation and deconvolution methods of airways in 3-D CT images, and significant improvement over the full-width-half-maximum method for measurement of not only location of the luminal and outer edge of the airway wall but airway wall thickness.

  • PDF

A Measurement System for Rounded Shoulder Posture using a Wearable Stretch Sensor

  • Nguyen, Manh Thang;Dang, Quoc Khanh;Kim, Younghoon;Chee, Youngjoon
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권1호
    • /
    • pp.10-15
    • /
    • 2018
  • In this paper, we present a wearable measurement system for monitoring rounded shoulders. The system contains a shoulder correction band and a stretch sensor that can correct and measure shoulder posture, respectively. The capacitance of the stretch sensor changes linearly according to changes in the shoulders. To verify measurement, a motion analysis system was used as the reference to compare the change in the rounded angles of the shoulders and the change in the stretch sensor's capacitance. The results indicated that there is a high correlation between the two changes and the system can be used as a monitoring device for rounded shoulders.

20대 여성의 목밑둘레 부위에 대한 3차원 자동 측정 알고리즘 (Three‐Dimensional Automatic Measurement Extraction Algorithms for Neck‐base Part of Females in Their Twenties)

  • 황근영;남윤자;박재경
    • 대한인간공학회지
    • /
    • 제24권2호
    • /
    • pp.35-43
    • /
    • 2005
  • The purpose of this study is to suggest computer assisted neck-base's landmark identification algorithms and measurement extraction methods from three-dimensional human scan data. So we developed the algorithms for automatic identification of landmarks related to the neck-base types. The subjects were 58 women $18{\sim}24$ years of age. Their body were measured directly and indirectly by using camera and three-dimensional body scanner. They were measured during the months of October in 2001. Based on the characters of classified neck-base types, algorithms for the automatic identification of landmarks and methods of automatic measurement are developed. The three-dimensional automatic measuring program is made by $C^{++}$ language. Using this program, 4 landmarks are identified and 6 items are measured. In the verifying the precision of automatic measurement, the height measurements(cervicale, side neck point, front neck point) were relatively accurate, but neck-base width measurement was measured wide.

의류 쇼핑 웹사이트 태도 형성 모델 연구 (제1보) -웹사이트 속성, 웹사이트 쇼핑가치, 웹사이트 태도 측정모형 검증- (Attitude toward the Website for Apparel Shopping (Part I): Measurement Model Testing)

  • 홍희숙
    • 한국의류학회지
    • /
    • 제28권11호
    • /
    • pp.1482-1494
    • /
    • 2004
  • This study identified convergent validity and discriminant validity of measurement variables by factor analysis using Spss program and tested covariance measurement model including latent variables such as the website attributes (interactivity, search and visual information of website), shopping values(utilitarian and hedonic value) and attitude toward website by AMOS program. The data were collected from a sample of 271 internet shopper of university students(male: 82, female: 189). They visited the website for apparel shopping and, after searching a casual clothing which they wanted to buy, requested to answer the questionnaire. The results were as follows: Variables that reduce validity were deleted in the several steps of factor analysis and initial measurement model testing. Final measurement model was constructed by valid variables was accepted. This measurement model will be input for testing causal research model that can explain how attributes of the website influences on consumer attitude toward the website.

측정 품질과 신뢰도 향상을 위한 교정주기 분석 프로그램의 개발 및 응용 (Development and Application of Calibration Interval Analysis Program for Measurement Quality and Reliability Improvement)

  • 박병선;안웅환;조중재
    • 품질경영학회지
    • /
    • 제34권1호
    • /
    • pp.54-72
    • /
    • 2006
  • In recent years, the widespread application of quality management and measurement reliability has put increasing emphasis on procedures for periodic instrument calibration. By optimizing calibration intervals, unnecessary calibrations can be minimized, thereby reducing costs. Moreover, optimizing intervals will improve compliance with regulatory directives while ensuring maximal compliance with reliability targets. In this paper, we present Calibration Interval Analysis Program developed using several establishment methodologies of calibration interval for measurement quality and reliability improvement. Also, we perform calibration interval analysis for some measurement instruments and analyse its results.

동작 적합성 평가를 위한 3차원 가상착의 프로그램 활용 방안 - 남성 진 팬츠를 중심으로 - (Utilization of 3D Virtual Garment Simulation Program Proposed for the Evaluation of Movement Fitness - Focusing on the Men's Jean Pants -)

  • 김경아;어미경;홍은희
    • 한국의상디자인학회지
    • /
    • 제17권4호
    • /
    • pp.55-66
    • /
    • 2015
  • The objective of this study is to propose a method by which movement fitness can be evaluated using a three-dimensional virtual garment simulation program. To this end, five types of jean pants for men were evaluated on the program by setting the avatars to make particular movements to examine the level of pressure on each body part. To verify whether the clothing pressure measurement produces valid and reliable results, virtual garment simulation program was utilized. The results indicated that there were significant differences in the levels of pressure on body parts depending on the type of test garment and motion. In addition, the clothing pressure measurement results were in line with the appearance evaluation results suggested by a previous study. Based on this set of results, the nomological validity of the clothing pressure measurement program used in this study was verified. Moreover, we employed an appearance evaluation along with the clothing pressure measurement to verify the reliability of the program; there was a high correlation between clothing pressure measurements and appearance evaluation measurements, indicating that measuring clothing pressures may well compensate for the limitations of appearance evaluation. We expect the results of this study to make valuable contributions in facilitating the digitalization of the fashion industry. Furthermore, this study also is significant in that it has suggested 3D virtual fitting programs as a solution to the long-criticized problem related to the evaluation of movement fitness in existing virtual garment simulation programs.

  • PDF