• Title/Summary/Keyword: Measurement Method

Search Result 15,846, Processing Time 0.037 seconds

무부하 급가속 측정 사이클로 운전되는 검사 대상 디젤 차량으로부터 배출되는 매연값 적분에 의한 차량 매연 대표값 특성 연구 (A Study on Evaluating a Representative Smoke Value from an Inspection Vehicle Using Integration Method over a Cycle of Free-Acceleration Test Mode)

  • 이충훈
    • 한국분무공학회지
    • /
    • 제18권3호
    • /
    • pp.132-139
    • /
    • 2013
  • Smoke emissions from light duty diesel vehicles were measured using light extinction method with the free acceleration test mode. The smoke emissions for each measurement cycle of the free acceleration method showed large variations according to driver's pedal pushing pattern. The smoke values for each measurement cycle initially increased and reach a peak value. Integration of the smoke emissions with time for each measurement cycle was performed to get a representative smoke value which was obtained by averaging the integrated results. Two kinds of integration time range were used. One is range over the whole measurement cycle of the free acceleration method. The other is only the acceleration range in the measurement cycle. Overall, variation of the representative smoke values obtained by the integration method was reduced comparing to the traditional representative smoke value which was obtained from a peak smoke value over the measurement cycle. Ten vehicles of the same model with 2.5 liter diesel engines, and seven vehicles of the same model with 2.7 liter diesel engines, were tested using the free acceleration test method.

A Study on the Difference Method of Magnetic Resonance Signal Measurement when Using Multi-channel Coil and Parallel Imaging

  • Choi, Kwan-Woo;Lee, Ho-Beom;Son, Soon-Yong;Jeong, Mi-Ae
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.220-226
    • /
    • 2017
  • SNR (signal to ratio) is a criterion for providing objective information for evaluating the performance of a magnetic resonance imaging device, and is an important measurement standard for evaluating the quality of MR (Magnetic Resonance) image. The purpose of our study is to evaluate the correct SNR measurement for multi-channel coil and parallel imaging. As a result of research, we found that both T1 and T2 weighted images show the narrowest confidence interval of the method recommended by NEMA (The National Electrical manufacturers Association) 1 having a single measurement method, whereas the ACR (American College of Radiology) measurement method using a multi-channel coil and a parallel imaging technique shows the widest confidence interval. There is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a ACR measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.

측정 잡음을 고려한 위치 결정 기법의 성능비교 (A Performance Comparison of Positioning Methods Considering Measurement Noise)

  • 박찬식;임재걸
    • 제어로봇시스템학회논문지
    • /
    • 제16권12호
    • /
    • pp.1176-1181
    • /
    • 2010
  • This paper proposes three positioning algorithms using TOA measurements: 1) The well-known linearization method using Taylor series, 2) a modified Savarese method considering measurement noise, which does not need linearization, and 3) a modified Bancroft method where TOA measurements instead of pseudorange measurements are considered. Furthermore, through an error analysis, for Savarese method, divergence of altitude is anticipated if the transmitters are located at the same height. To prevent height divergence, the Savarese method is modified again for receivers which assumed moving on the even plane. Error analysis also shows the relationship between Bancroft and Savarese method. From the analysis it is expected that the performance of Savarese method is worse than Bancroft method because of error amplification during difference operation. Experiments using real TOA measurement from the time difference of ultra sound and RF validate the proposed methods and show that analysis is correct.

Application of Phase-Shifting Method in Speckle Interferomtery to Measurement of Micro-Scale Displacement

  • Baek, Tae-Hyun;Kim, Myung-Soo
    • 비파괴검사학회지
    • /
    • 제26권3호
    • /
    • pp.162-168
    • /
    • 2006
  • Speckle interferometry with phase-shifting method has been applied to measurement of micro-scale displacement through optical signal processing. Four-step phase-shifting method by PZT is used to measure out-of-plane displacement in spot-welded cantilever and results of optical experiments are comparable to those of FEM. Phase-shifting method using Fourier transform by PZT is applied to measurement of in-plane displacement on rectangular steel plate with a circular hole. The results of optical experiment agree well with theoretical calculation. New phase-shifting method in speckle interferometry has been implemented with a quarter wave plate. In-plane displacement of specimen is measured by the new phase-shifting method. Results of optical experiment show that the quarter wave plate can be used for phase-shifting method that is cheap and easy to use in speckle interferometry.

광학적 비접촉 측정에 의한 구조물 해석의 화상처리 계측 시스템 개발에 관한 연구 (A Study on the Development of Image Processing Measurement System on the Structural Analysis by Optical Non-contact Measurement)

  • 김경석
    • 한국생산제조학회지
    • /
    • 제8권6호
    • /
    • pp.78-83
    • /
    • 1999
  • This study discusses a non-contact optical technique, electronic speckle pattern interformetry(ESPI), that is well suited for in-plane and out-of-plane deformation measurement. However, the existing ESPI methods that are based on dual-exposure, real-time and time-average method have difficulties for accurate measurement of structure, due to irregular intensity and shake of phase. Therefore, phase shifting method has been proposed in order to solve this problem. About the method, the path of reference light in interferometry is shifted and added to least square fitting method to make the improvement in distinction and precision. This proposed method is applied to measure in -plane displacement that is compared with the previous method. Also, Used as specimen AS4/PE따 [30/=30/90]s was analyzed by ESPI based on real-time to determine the characteristics of vibration under no-load and tension. These results are quantitatively compared with those of FEM analysis inmode shapes.

  • PDF

광 최소/최대법을 이용한 IPS-LCD의 잔류 DC 전압 측정 (Measurement of Residual DC Voltage in the IPS-LCD by Light Minimum/Maximum Method)

  • 전용제;김향율;김재형;한은주;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.354-357
    • /
    • 2001
  • The residual DC properties in the in-plane switching (IFS) liquid crystal displays(LCDs) which have different concentrations of cynao NLCs and different resistivities of fluorine NLCs were studied. We also propose a new residual DC measurement method, named 'light minimum/maximum method'. We confirmed the precision of residual DC measurement by light minimum/maximum method compared with the flicker minimizing method and found that new measurement method of residual DC is better than that of the conventional flicker minimizing method since the resolution level of measurements is in 0.1V

  • PDF

광 최소/최대법을 이용한 IPS-LCD의 잔류 DC 전압 측정 (Measurement of Residual DC Voltage in the IPS-LCD by Light Minimum/Maximum Method)

  • 전용제;김향율;김재형;한은주;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.354-357
    • /
    • 2001
  • The residual DC properties in the in-plane switching (IPS) liquid crystal displays(LCDs) which have different concentrations of cynao NLCs and different resistivities of fluorine NLCs were studied. We also propose a new residual DC measurement method, named 'light minimum/maximum method'. We confirmed the precision of residual DC measurement by light minimum/maximum method compared with the flicker minimizing method and found that new measurement method of residual DC is better than that of the conventional flicker minimizing method since the resolution level of measurements is in 0.1 V

  • PDF

프레넬영역 안테나 측정법의 파리미터 분석과 측정 가이드라인 제시 (Parametric Analysis and Measurement Guideline of Fresnel Region Antenna Measurement Method)

  • 오순수
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.351-352
    • /
    • 2008
  • In this paper, parametric analysis of Fresnel region antenna measurement method has been performed for the square aperture having the uniformly distributed current. The optimum number of Fresnel region field and the tolerable distance between two antennas have been guided. This parametric analysis could be fully utilized when performing Fresnel region antenna measurement method. Other types of current distribution and aperture shape will be investigated in the near future

  • PDF

송풍기의 소음레벨 측정방법 (KS B6361, 2000년 개정내용을 중심으로) (Methods of A-weighted Sound Pressure Level Measurement for Fans and Blowers (KS B 6361, Focus on Revised Content made in 2000))

  • 김경호;이승배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.424-432
    • /
    • 2000
  • The revision was provided for the method of A-weighted sound pressure measurement for fans and blowers, in which the newly developed measurement techniques were applied to KS B 6361. This revision includes the sound power methods for radiated sound from the body, the in-duct measurement method, and the correction method for flow noise upon measuring microphone, etc.

  • PDF

인간공학적 좌석평가를 위한 좌면 형상 변형측정에 관한 연구 (A new seat surface deformation measurement method for ergonomic seat evaluation)

  • 이남식
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 1990년도 춘계공동학술대회논문집; 한국과학기술원; 28 Apr. 1990
    • /
    • pp.171-185
    • /
    • 1990
  • In order to measure the shape deformation of seat surfaces, an indentation measurement mat was devised. The 50cm * 50 cm mat containing small polyethylene beads were made using two sheets of polyurethane film. The indentation measurement mat was shaped by vacuuming between the subject and the testing seat. This method showed less than 5mm of deformation measurement error. Deformation of CADILLAC and MAXIMA seats were compared to demonstrate usefulness of the new method.

  • PDF