• Title/Summary/Keyword: Measurement Deviation

검색결과 948건 처리시간 0.092초

일점측위에 의한 GPS측정 (GPS Surveying by A Point Positioning)

  • 이용희;문두열
    • 한국항만학회지
    • /
    • 제12권1호
    • /
    • pp.119-130
    • /
    • 1998
  • As a satellite positioning system, GPS is designed to provide the information on three dimensional position, velocity, and time all over the world. The purpose of this paper is to obtain what day has the best accuracy and what time has the best accuracy of measuring of forteen-twenty mimutes for effective using of MAGELLAN G.P.S NAV DLX-10 system. The result of measurement maximum deviation value from November, 1997 to March, 1998 that latitude deviation is 3' .75 and longitude deviation is 2' .1 And the result of measurement maximum deviation value during fourteen minutes of April 29, 1998 that latitude deviation is 3' .75 and longitude deviation is 1' .9. The result of measurement maximum deviation value during twenty minutes of May 6, 1998 that latitude deviation is 4' .75 and longitude deviation is 2' .1 and that is provid 3' .25, 4' .1 to May 13, 1998. So, we expect efficient use of horizontal position for navigation.

  • PDF

안모비대칭의 진단용 기준선의 유용성에 관한 연구 (A STUDY ON USEFULNESS OF THE REFERENCE LINE IN DIAGNOSIS OF THE FACIAL ASYMMETRY)

  • 류성호;장현호
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권3호
    • /
    • pp.266-273
    • /
    • 2005
  • Purpose: To assess the relationship between soft tissue reference line and hard tissue reference line using the standardized photographs and the posteroanterior cephalometric radiographs(P-A)in facial asymmetric patients and to compare the differences of angular measurement between normal group and asymmetry group. Methods: Normal group consisted of 44 persons with normal occlusion and normal facial morphology. Asymmetry group consisted of 90 patients with facial asymmetry. Standardized facial photographs and P-A were taken in all subjects. The horizontal reference lines were bipupillary line in photographs and latero-orbitale line in P-A respectively. The vertical reference line were the line from the midpoint of horizontal reference line perpendicularly. Angular measurement of otobasion canting, lip canting, nose deviation, chin deviation, and maxillary deviation were compared and analyzed in photographs. And angular measurement of mastoid canting, mandibular canting, nose deviation, chin deviation, and maxillary deviation were compared and analyzed in P-A. Results: 1. The variables of photographs and P-A were significantly related in the asymmetry group. 2. Significant differences between all variables except for PT2 and PA2 were shown in the asymmetry group and between PT1 and PA1, PT3 and PA3 in the normal group respectively. 3. Comparison measurement scores of angular difference between control group and experimental group concerning each variable showed significant difference except for PA1. Conclusions: Soft tissue components may not compensate for underlying skeletal imbalance in nose deviation and chin deviation. The horizontal reference lines in photographs were significant related with the P-A, but angular variables between the two studies show significant differences. Therefore, we do not recommend use photography in the assessment the facial asymmetry as complemented in the P-A.

항공사진측량과 위성영상측량에서 거리측정 정확도 연구 (Analysis of Distance Measurement Accuracy in Aerial and Satellite Image Photogrammetry)

  • 김형무;차득기;남권모;양철수
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2010년 춘계학술발표회 논문집
    • /
    • pp.253-255
    • /
    • 2010
  • 항공사진측량과 위성영상측량에서 거리측정정확도에 대한 연구의 필요성이 급증하고 있다. 그러나 기존 연구들에서는 표준편차와 제곱평균편차간은 물론이고 측정정확도와 측정정밀도간의 정의에 대한 경향성 있는 혼동된 이해가 들어있다. 따라서 본 연구는 항공사진측량과 위성영상측량에서 거리정확도에 관한 표준편차와 제곱평균편차간은 물론이고 측정 정확도와 측정 정밀도간의 관계에 대한 제한적인 정의를 제안한다. 실험결과는 제안한 정확한 정의가 거리측정 정밀도가 아닌 항공사진측량과 위성영상측량에서 거리정확도에서의 개선을 가져옴을 보여준다.

  • PDF

Developing of Grading Method using 3D Body Measurement Data of Women in Their Thirties -Focusing on Their Proper Body Types-

  • Shin, Ju-young Annie;Nam, Yun-ja
    • 한국의류산업학회지
    • /
    • 제19권6호
    • /
    • pp.749-758
    • /
    • 2017
  • The purpose of the present study is to develop a grading deviation, which is appropriate for the body type of women in thirties, by analyzing the three-dimensional body type. The materials for the study were adopted from the body measurement data of women in the age group of 30 to 39 years old, provided from Size Korea. By reflecting the factor analysis results using the three-dimensional shape measurement, deviations were derived. First, six factors influencing the changes in human body shape were derived as waist-hip length factor, bust-waist shape factor, back protrusion back shoulder factor, bust length factor, shoulder length factor, and frontal waist dart factor. The bust size and height, which can be easily utilized for the top original grading, were used for deriving a regression formula, and the deviation was set in accordance with the result. Second, by applying the deviation which reflects the changes in the body shape, the crimps which were generated due to the application of existing deviation were remarkably reduced, indicating that the grading of the present study is more fitting than the existing one. The deviation derived by the analysis of actual increase and decrease of body size was more fitting than the existing one. This was proved by actual wearing experiment, which represents the significance of this study.

출산유형이 산모의 골반변위에 미치는 영향에 관한 방사선학적 연구 (The Radiological Study on the Pelvic Deviation in Delivery Women)

  • 김철한;김희준;신병철;김정연
    • 대한추나의학회지
    • /
    • 제5권1호
    • /
    • pp.11-17
    • /
    • 2004
  • Objective : Women can be affected physically and psychologically by pregnancy and delivery. Because the relaxation of pelvic ligaments has a chance to cause pelvic deviation, we investigated the radiological peivic deviation according to delivery types and experiences. Method : 71 patients were evaluated by X-ray findings. Every patients divided into two group according to delivery types and experiences. After measured innominate measurement. off centering measurement, sacral ala measurement and ilium shadow measurement, X-ray findings in each group were analyzed statistically. Results and Conclusions : It was concluded that the ilium was more deviated into outer side in normal delivery group than caesarean operation group, and more deviated into inner or outer side in multipara group than primipara group.

  • PDF

말뚝 변위 측정시스템의 진동 평가에 의한 정확도 향상 대책 (A Measure for Improvement in Accuracy by Performance Evaluation of a DPRMs)

  • 최영삼;정진태;이계영;한창수
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1653-1659
    • /
    • 2005
  • In this study, the performance of a DPRMs is evaluated and the measurement precision for the pile driving is presented. The DPRMs is a visual-measurement system for the pile rebound and the penetration movement using a high speed line-scan camera. The DPRMs generates the measurement deviation. It is caused by the strong impact for the pile driving. To reduce it, the vibration signal analysis about the pile driving is performed. As a result, it is confirmed that the tilting frequency of a camera-tripod structure corresponding to excitation frequency range of the ground is under 40Hz. Through the structure modification, the camera-tripod structure is redesigned to the model being free itself from the excitation frequency range of the ground. By the verification testing about the improvement effects, it is inspected that the tilting and measurement deviation of the redesigned DPRMs are reduced.

Reliability of Lateral Deviation Measurement in the Hyoid Bone With Center Point and Lateral Motion Tests

  • Min, Hye-jin;Yoon, Tae-lim
    • 한국전문물리치료학회지
    • /
    • 제26권3호
    • /
    • pp.76-83
    • /
    • 2019
  • Background: The hyoid bone is the only non-jointed structure among the skeletal tissues of the head and neck region, and its movement and posture depend on the attached muscle, ligament, and fascia. The location of the hyoid bone is important for airway maintenance, vocalization, chewing, swallowing, breathing, and head and scapular position. In general, the location of the hyoid bone is measured using radiographs and 3D computed tomography, and no studies have reported on clinical measurement methods. Objects: This study was performed to suggest clinical measurement methods for lateral deviation of the hyoid bone and to evaluate their reliability. Methods: In this study, 24 healthy volunteers (12 males, 12 females) in Cheongju-si participated. Two examiners performed the center point test and lateral motion test twice each to measure the lateral displacement of the hyoid bone. The reliability of the center point test was analyzed using intra-class correlation coefficients (ICC), and the reliability of the lateral motion test was analyzed using Cohen's kappa coefficient. Results: The intra-rater reliability of the center point test was good, and the inter-rater reliability was moderate. The intra- and inter-rater reliability of the lateral motion test showed substantial reliability. Conclusion: Based on these results, the center point test and the lateral motion test can be used as an alternative methods of the measurement of lateral deviation of the hyoid bone for people who have musculoskeletal disorders of the head, neck, and scapula.

cds 광전소자(光電素子)를 이용한 인공태양(人工太陽) 일사강도(日射强度)의 동시측정(同時測定) (One-time measurement of irradiation intensity of Solar Simulator using cds photo-sensors)

  • 배강;조서현;이보호;오정무
    • 태양에너지
    • /
    • 제5권2호
    • /
    • pp.28-34
    • /
    • 1985
  • There are two kinds of irradiation intensity deviation, depending on time and position, on illuminated plane when thermal performance of solar collector is tested by using solar simulator. In this study we measured only position deviation of irradiation intensity using 45-cds photosensors and data acqusition system and found the point of average value. By this result we can improve the accuracy of irradiation measurement in indoor test of solar collector.

  • PDF

PLL 주파수 합성기를 이용한 새로운 주파수 변조 회로 설계 및 제작 (Design and Implementation of a Novel Frequency Modulation Circuit using Phase Locked Loop Synthesizer)

  • 양승식;이종환;염경환
    • 한국전자파학회논문지
    • /
    • 제15권6호
    • /
    • pp.599-607
    • /
    • 2004
  • 이 논문은 PLL주파수 합성기의 루프 대역폭보다 높은 주파수에서 낮은 주파수까지 변화하는 신호에 대한 주파수 변조가 일정한 최대 주파수 편이를 갖도록 하는 단순하면서도 저가의 새로운 주파수 변조회로를 소개하였다. 이 주파수 변조회로는 PLL 안에서의 주파수에 따른 루프 필터의 궤환량을 보상하도록 설계되었고 최대주파수 편이값 조절과 루프와의 상호 간섭을 제거할 수 있도록 설계되었다. 또한 기존의 스펙트럼 분석기로 $\Delta$f(최대 주파수 편이)또는 $\beta$(변조 지수)를 측정하는 방법은 협대역 주파수 변조에서만 유용하여 광대역 주파수에서 측정할 수 있도록 새로운 측정방법을 제안하고 변조 신호 발생기를 이용하여 정확성을 확인하였다. 이런 한 방법으로 설계하여 제작한 회로를 측정하여 기대한 일정한 최대 주파수 편이를 가지는 것을 확인하였다.

레이저센서를 이용한 비접촉식 두께자동측정기 개발 (Development of Automated Non-contact Thickness Measurement Machine using a Laser Sensor)

  • 조경철;김수연;신기열
    • 한국기계가공학회지
    • /
    • 제14권2호
    • /
    • pp.51-58
    • /
    • 2015
  • In this study, we developed an automated non-contact thickness measurement machine that continuously and precisely measures the thickness and warp of a PCB product using a laser sensor. The system contains a measurement part to measure the thickness in real time automatically according to the set conditions with an alignment supply unit and unloading unit to separate OK and NG products. The measurement machine was utilized to evaluate the performance at each step to minimize measurement error. At the zero setting for the initial setup, the standard deviation of the 216 samples was determined to be $5.52{\mu}m$. A measurement error of 0.5mm and 1.0mm as a standard sample in the measurement accuracy assessment was found to be 2.48% and 2.28%, respectively. In the factory acceptance test, the standard deviation of 1.461mm PCB was measured as $28.99{\mu}m$, with a $C_{pk}$ of 1.2. The automatic thickness measurement machine developed in this study can contribute to productivity and quality improvement in the mass production process.