• 제목/요약/키워드: Measured Intensity Control

검색결과 360건 처리시간 0.025초

위상 검출 방식 레이저 스캐너의 APD bias 전압 특성을 이용한 검출신호세기 제어 방법 (Measured Intensity Control Method of a Phase-shift Measurement Based Laser Scanner by using APD Bias Voltage Characteristic)

  • 장준환;윤희선;황성의;박기환
    • 한국정밀공학회지
    • /
    • 제29권10호
    • /
    • pp.1096-1100
    • /
    • 2012
  • In the phase-shift measurement method, the distance light travels can be obtained based on the phase difference between the reference signal and the measured signal. When the object having various colors is measured, the intensity of the measured signal much varies even at the same distance, and it causes different phase delay due to wide dynamic range input to a signal processing circuit. In this work, an measured intensity control method is proposed to solve this phase delay problem.

COVID-19로 인한 마스크 착용이 보행 속도에 따라 심혈관계 기능에 미치는 영향 (Effects of Mask Wearing Due to COVID-19 on Cardiovascular Function in Treadmill Exercise)

  • 남기원;서동열
    • 대한물리의학회지
    • /
    • 제17권4호
    • /
    • pp.37-43
    • /
    • 2022
  • PURPOSE: To find out how wearing a mask due to COVID-19 affects cardiovascular function as the pace of walking changes. METHODS: Forty-nine college students (27 men, 22 women) were subjected to treadmill exercises without masks (Group I) and wearing masks (Group II). The body temperature, heart rate, oxygen saturation, and blood pressure were measured to determine the changes in cardiovascular function. These parameters were measured at rest (Control I), low-intensity (Control II), medium-intensity (Control III), and high-intensity (Control IV) before and after exercise. RESULTS: Significant differences in heart rate were observed between Control III and Control IV, and a significant difference in oxygen saturation was noted in Control IV. Significant differences in the exercise intensity change in Group II were as follows: Body temperature was Control IV compared to Control I and Control II, heart rate was Control III and Control IV compared to Control I and Control II, and Control IV compared to Control III. The heart rate was Control III and Control IV compared to Control I and Control II, Control IV for Control III, oxygen saturation was Control IV compared to Control I, blood pressure was Control II and Control III and Control IV compared to Control I, and Control IV compared to Control II. CONCLUSION: Exercising when wearing a mask affects the cardiovascular system. Therapists should consider the patient's condition when setting the exercise intensity. In particular, therapists should be more careful when setting the exercise intensity of patients with cardiovascular disease.

Effects of High-intensity Intermittent Training and Moderate-intensity Training on Cardiopulmonary Capacity in Canoe and Kayak Paddlers during 8 Weeks

  • Kim, Ah-Ram;Shin, Won-Seob
    • 대한물리의학회지
    • /
    • 제9권3호
    • /
    • pp.307-314
    • /
    • 2014
  • PURPOSE: The purpose of this study was to investigate the effects of high intensity intermittent training on cardiopulmonary capacity in canoe and kayak paddlers. METHODS: A total of 16 canoe and kayak paddlers were participated in this study. Experimental group(n=8) was performed high-intensity intermittent training and control group(n=8) was moderate intensity training. All subjects performed a treadmill test in order to compare the difference before and after the intervention. Finishing the test, all subjects were measured to their heart rate(HR), forced vital capacity(FVC), forced expiratory volume in one second (FEV1) and forced expiratory ratio(FEV1/FVC). Recovery of heart rate(RHR) was calculated using the HR. HR and pulmonary flow values was measured before and during the intervention period per 2, 4, 6 and 8 weeks. To compare the differences over time between experimental group and the control group, used(time${\times}$group) two-way repeated measures ANOVA. One-way repeated ANOVA was performed to determine where differences over time within-group. RESULTS: One-way repeated ANOVA revealed a significant difference in the experimental and control group. In experimental group, %RHR3min and FEV1 were significantly increased after 4 weeks(p<.05). Also, %RHR1min, FVC and FEV1/FVC were significantly increased after 6 weeks(p<.05). In control group, %RHR1min, %RHR3min, FVC, FEV1 and FEV1/FVC were significantly increased after 6 weeks(p<.05). CONCLUSION: Not only moderate training but also high-intensity intermittent training contributes to cardiopulmonary capacity in canoe and kayak paddlers. Although high-intensity intermittent training is very short time, the training has high degree of efficiency. Therefore, developed this training in the future, it will be better to improve the cardiopulmonary capacity for athletes and healthy people.

The Effects of High Intensity Laser Therapy on Pain and Function of Patients with Frozen Shoulder

  • Jeon, Chun-Bae;Choi, Seok-Joo;Oh, Hyun-Ju;Jeong, Mu-Geun;Lee, Kwan-Sub
    • The Journal of Korean Physical Therapy
    • /
    • 제29권4호
    • /
    • pp.207-210
    • /
    • 2017
  • Purpose: This study was to identify the effectiveness of high-intensity laser therapy on pain and function of a frozen shoulder. Methods: Thirty patients were assigned to two groups: the experimental group (n=15) and the control group (n=15). Both groups received traditional therapy for 4 weeks, 3 days a week. The experimental group, however, received an additional high intensity laser therapy. Pain was measured using the visual analogue scale (VAS). The functional ability was measured using the patient specific functional scale (PSFS). A paired t-test was used to determine any differences before and after the treatment, and an independent t-test was used to determine any differences between treatment groups. Results: Both groups showed a statistically significant difference for VAS and PSFS score (p<0.05). In comparison between two groups, more experimental group than control group statistically significant difference (p<0.05). Conclusion: There seems to be a positive effect on pain and function of frozen shoulder from using high intensity laser therapy.

AMR센서를 이용한 옥외용 AGV 주행센서 시스템에 관한 연구 (A Study on Navigation Sensor System for Outdoor AGV Using AMR Sensors)

  • 김성호;박경섭
    • 제어로봇시스템학회논문지
    • /
    • 제9권2호
    • /
    • pp.140-144
    • /
    • 2003
  • A navigation sensor system for outdoor AGV(Automatic Guided Vehicle) using AMR(Anisotropic Magnetoresitive) sensors is described. We derive a formula of the position of AMR sensor using the measured magnetic field intensity due to permanent magnet with constant distance. The system consists of sensor board. sensor control board and position processing board. The sensor board measures magnetic field intensity, the sensor control board controls the measurement of six sensors sequentially, and the position processing board computes the accurate position of the permanent magnet using Least Square Method. We arranged six sensors at intervals of 30cm and measured the position of the permanent magnet moving at intervals of 30cm. Experimental results showed that we can get standard deviation of 2mm and error of &\pm&4.5mm at a height of 20cm from the permanent magnet.

Oligomerized polyphenols in lychee fruit extract supplements may improve high-intensity exercise performance in male athletes: a pilot study

  • Kawamura, Aki;Hashimoto, Shun;Suzuki, Miho;Ueno, Hiromasa;Sugita, Masaaki
    • 운동영양학회지
    • /
    • 제25권3호
    • /
    • pp.8-15
    • /
    • 2021
  • [Purpose] Excessive reactive oxygen species (ROS) induced by prolonged high-intensity exercise can cause structural and functional damage. Antioxidant polyphenol supplementation, which reduces ROS levels, may improve high-intensity exercise performance. We evaluated the effect of lychee fruit extract, which contains high levels of low-molecular-weight oligomerized polyphenols, on high-intensity exercise performance. [Methods] Ten male athletes were included in an open-label trial that consisted of control and intervention phases, with a 7-day washout period between phases. The participants were administered oligomerized lychee fruit extract for seven days, whereas no intervention was given in the control phase. High-intensity intermittent exercise and the Wingate test were performed. The power output, blood lactate levels, reactive oxygen metabolite levels, biological antioxidant potential, heart rate, and rate of perceived exertion were measured. [Results] The average power output was significantly higher in the intervention phase than in the control phase (P < 0.01), while the change in blood lactate levels was significantly lower in the intervention phase than in the control phase (P < 0.05). The average heart rate was significantly higher in the intervention phase than in the control phase (P < 0.05), without changing the rate of perceived exertion. Although there was no difference in reactive oxygen metabolite levels between the phase, the change in biological antioxidant potential was larger in the intervention phase than in the control phase (P = 0.06). The Wingate test showed no significant differences between the phase. [Conclusion] Short-term loading with oligomerized lychee fruit extract may increase performance during high-intensity intermittent exercise by improving metabolism.

열목지 경유센서에 의한 멜론 경유양의 측정 (Measurement of Mass Flow of Water in the Stem of Musk Melon by Sap Flow Gauge)

  • 강곡명;양원모
    • 생물환경조절학회지
    • /
    • 제7권3호
    • /
    • pp.268-274
    • /
    • 1998
  • 열수지 경류센서에 의한 멜론의 흡수량 측정오차는 최저 0.3%에서 최대 31.8% 범위 내에 있었으며, 일사량 20MJ.m$^{-2}$ .d$^{-1}$에서는 오차가 적었으나 일사량이 이보다 많아지면 많아질수록 센서측정 경류량이 실측양액 소비량보다 적어지는 경향이었고 일사량이 적어질수록 센서측정 경류량이 실측양액 소비량보다 많아지는 경향이었다. 센서간의 오차는 최저 0.1%에서 최대 13.0%의 오차율을 보였다. 열수지센서측정 경류량은 일사량이나 온도와 고도의 부의 상관관계를 보였다. 그러므로 이를 이용 보정계수를 산출하면 보다 정확한 멜론의 경류량을 측정할 수 있을 것으로 판단되었다.

  • PDF

Analysis of Postural Stability in Response to External Perturbation Intensity in Dancers and Non-dancers

  • Park, Da Won;Koh, Kyung;Lee, Sung Ro;Park, Yang Sun;Shim, Jae Kun
    • 한국운동역학회지
    • /
    • 제26권4호
    • /
    • pp.427-432
    • /
    • 2016
  • Objective: The goal of this study was to systematically investigate the postural stability of dancers by providing unexpected perturbations. Method: Six female dancers and college students participated in this study. Unpredictable wait-pull balance perturbations in the anterior direction were provided to the participants during standing. Three different perturbation intensities (low, moderate, and high intensity) were used by increasing perturbation forces. Spatial and temporal stability of postural control were measured by using margin of stability (MoS) and time to contact (TtC), respectively. Results: Both MoS and TtC at moderate intensity were significantly greater in the dancer group than in the control group, but no significant differences were found at low and high intensities between the groups. Conclusion: The present study showed spatial and temporal stability of dynamic postural control in dancers. We found that the dancers were more spatially and temporally stable than the ordinary participants in response to unexpected external perturbation when the perturbation intensity was moderate at two extreme intensity levels (low and high).

Power control of CiADS core with the intensity of the proton beam

  • Yin, Kai;Ma, Wenjing;Cui, Wenjuan;He, Zhiyong;Li, Xinxin;Dang, Shiwu;Yang, Feng;Guo, Yuhui;Duan, Limin;Li, Meng;Hou, Yikai
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1253-1260
    • /
    • 2022
  • This paper reports the control method for the core power of the China initiative Accelerator Driven System (CiADS) facility. In the CiADS facility, an intense external neutron source provided by a proton accelerator coupled to a spallation target is used to drive a sub-critical reactor. Without any control rod inside the sub-critical reactor, the core power is controlled by adjusting the proton beam intensity. In order to continuously change the beam intensity, an adjustable aperture is considered to be used at the Low Energy Beam Transport (LEBT) line of the accelerator. The aperture size is adjusted based on the Proportional Integral Derivative (PID) controllers, by comparing either the setting beam intensity or the setting core power with the measured value. To evaluate the proposed control method, a CiADS core model is built based on the point reactor kinetics model with six delayed neutron groups. The simulations based on the CiADS core model have indicated that the core power can be controlled stably by adjusting the aperture size. The response time in the adjustment of the core power depends mainly on the adjustment time of the beam intensity.

Mesh 스크린을 이용한 충돌제트 열전달 제어에 관한 연구 (Control of Impinging Jet Heat Transfer with Mesh Screens)

  • 조정원;이상준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.267-271
    • /
    • 2000
  • The local heat transfer rate of an axisymmetric submerged air jet impinging on normal to a heated flat plate was investigated experimentally with varying solidity of mesh screen. The mean velocity and turbulent Intensity profiles of streamwise velocity component were measured using a hot-wire anemometry. The temperature distribution on the heated flat surface was measured with thermocouples. The screen installed in front of the nozzle exit(behind of 35mm) modify the jet flow structure and local heat transfer characteristics. For higher solidity screen, turbulence intensity at core lesion is high and increases the local heat transfer rate at nozzle-to-plate spacings(L/D<6). For larger nozzle-to-plate spacings(L/D>6), however, the turbulent Intensities of all screens tested in this study approach to an asymptotic curve, but the small mean velocity at the core region reduces the local heat transfer rate for high solidity screens.

  • PDF