• Title/Summary/Keyword: Measure of Size

Search Result 2,038, Processing Time 0.035 seconds

Development of a 3-Dimensional Measurement System using Laser Vision (레이저 비전을 이용한 3차원 측정 시스템 구현)

  • Kwon, Hyo-Geun;Chun, Young-Seok;Suh, Young-Soo;Ro, Young-Shick
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.973-979
    • /
    • 2007
  • A laser vision system is developed to measure the three-dimensional feature of an object. This system consists of two low cost cameras and a cross laser. One camera and a cross laser are used to measure a plane equation of an object. Using this information, the other camera measures a hole size of an object. The proposed system provides 0.05 mm accuracy measurement systems with relatively low cost.

Investigation on the Effective Calibration of Annubar (다점식 피토관의 효율적인 교정에 대한 연구)

  • Choi Yong-Moon;Choi Hae-Man;Choi Ji-Chul;Hong Kyung-Ki;Han Sang-Woo;Kim Woong-Sun;Chun Se-Jong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.4 s.247
    • /
    • pp.373-380
    • /
    • 2006
  • Annubar is one of popular tools to measure the exhausted gas flow rate from the stacks. For the accurate monitoring of the amount of discharged pollutants, calibration of annubar is very important. Calibration of annubar has been carried out in a wind tunnel. When the length of annubar is longer than the test section size of wind tunnel, it is very difficult to find out typical value of annubar coefficients. So, a measurement technique to calibrate annubar longer than the size of the test section of wind tunnel must be developed. In the present study, an experiment is performed to measure the annubar coefficients in such a limited size of the wind tunnel. The experimental annubar coefficient by using a partial blocking technique is very close to the annubar coefficient of normal condition.

Study on Development of Infrared Retinoscope (적외선 검영기의 개발에 관한 연구)

  • Lee, Ik-Han;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.29-34
    • /
    • 2004
  • The aim of this thesis research is to develop equipment measuring refractive state in order to measure the general ocular function using PC-based Foucault Test(Knife Edge Test). The Image of light generated from the reflection of incident light in retina thru Knife Edge Test was photographed using a CCD camera. The resulting image was then analyzed to measure the size of pupil by measuring the diameter of reflected image. The reflection state was judged from the orientation of reflected image and the degree of abnormal reflection was confirmed by measuring the size of second image of reflection. The aberration value was calculated from the magnitude of spherical aberration obtained by comparing the brightness of second reflected image appeared in the opposite direction to the reflected image.

  • PDF

Measurement of Surface Temperature for Real Time Monitoring of the GMA Welding Processes (GMA용접공정의 실시간 모니터링을 위한 표면온도 측정)

  • 부광석;조형석
    • Proceedings of the KWS Conference
    • /
    • 1994.10a
    • /
    • pp.111-114
    • /
    • 1994
  • This paper describes a method to measure a weldment surface temperature for estimating variations of the weld pool size in the gas metal arc(GMA) welding processes. An Infrared sensing system is designed to measure the radiation emitted from the top surface of the weldment, The interference effect of the electric arc to the measurement is rejected by detecting the low peaks of the noisy signal. An optimizing criterion, in which the correlation between the weld quality and the measured temperature is maximized, is also proposed to determine the optimal measurement location.

  • PDF

Unbalanced ANOVA for Testing Shape Variability in Statistical Shape Analysis

  • Kim, Jong-Geon;Choi, Yong-Seok;Lee, Nae-Young
    • The Korean Journal of Applied Statistics
    • /
    • v.23 no.2
    • /
    • pp.317-323
    • /
    • 2010
  • Measures are very useful tools for comparing the shape variability in statistical shape analysis. For examples, the Procrustes statistic(PS) is isolated measure, and the mean Procrustes statistic(MPS) and the root mean square measure(RMS) are overall measures. But these measures are very subjective, complicated and moreover these measures are not statistical for comparing the shape variability. Therefore we need to study some tests. It is well known that the Hotelling's $T^2$ test is used for testing shape variability of two independent samples. And for testing shape variabilities of several independent samples, instead of the Hotelling's $T^2$ test, one way analysis of variance(ANOVA) can be applied. In fact, this one way ANOVA is based on the balanced samples of equal size which is called as BANOVA. However, If we have unbalanced samples with unequal size, we can not use BANOVA. Therefore we propose the unbalanced analysis of variance(UNBANOVA) for testing shape variabilities of several independent samples of unequal size.

Design and Implementation of an Absolute Position Sensor Based on Laser Speckle with Reduced Database

  • Tak, Yoon-Oh;Bandoy, Joseph Vermont B.;Eom, Joo Beom;Kwon, Hyuk-Sang
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.362-369
    • /
    • 2021
  • Absolute position sensors are widely used in machine tools and precision measuring instruments because measurement errors are not accumulated, and position measurements can be performed without initialization. The laser speckle-based absolute position sensor, in particular, has advantages in terms of simple system configuration and high measurement accuracy. Unlike traditional absolute position sensors, it does not require an expensive physical length scale; instead, it uses a laser speckle image database to measure a moving surface position. However, there is a problem that a huge database is required to store information in all positions on the surface. Conversely, reducing the size of the database also decreases the accuracy of position measurements. Therefore, in this paper, we propose a new method to measure the surface position with high precision while reducing the size of the database. We use image stitching and approximation methods to reduce database size and speed up measurements. The absolute position error of the proposed method was about 0.27 ± 0.18 ㎛, and the average measurement time was 25 ms.

Implemention of Physical Measuring Device using Arduino (아두이노를 활용한 신체 측정 디바이스 구현)

  • Kim, Yong-Hwan;Song, Jong-Gun;Kim, Tae-Yong;Jang, Won-Tae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.519-521
    • /
    • 2015
  • Recently Sharp in use of smartphones has been inventing convenient application in living. Among the application to use a lot of people about to diet and exercise have to measure the their heart rate and activity. but have to nothing to measure th their body size. In this paper using Arduino and ultrasonic sensor, The distance between the sensor to be measured on the body size, value output a LCD, the size value to the application transferring through a Bluetooth communication smartphone, they knew exactly what the exercise for body part that is what they wants.

  • PDF

노트수에 의한 프로그램 복잡성 개선

  • No, Cheol-U
    • ETRI Journal
    • /
    • v.5 no.3
    • /
    • pp.16-25
    • /
    • 1983
  • Increasing importance is being attached to the idea of measuring software characteristics. This paper deals with following things. First, a relation of program and flow graph is discussed. It describes a theoretic complexity measure and illustrates how it can be used to manage and control program complexity. Second, cyclomatic complexity measure is discussed. The complexity is independent of physical size and depends only on the decision structure of a program. Third, consider a knot which defines crossing point and provide the ordering of the nodes to make the transition from a two dimensional graph to a one dimensional program. A program modules that can improve FORTRAN IV program text is tested by knot counting and its control complexity is improved.

  • PDF

Depth Extraction From Focused Images Using The Error Interpolation (오류 보정을 이용한 초점 이미지들로부터의 깊이 추출)

  • 김진사;노경완;김충원
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.627-630
    • /
    • 1999
  • For depth extraction from the focus and recovery the shape, determination of criterion function for focus measure and size of the criterion window are very important. However, Texture, illumination, and magnification have an effect on focus measure. For that reason, depth map has a partial high and low peak. In this paper, we propose a depth extraction method from focused images using the error interpolation. This method is modified the error depth into mean value between two normal depth in order to improve the depth map.

  • PDF

Comparative Assessment of the Vertebral Left Atrial Size in Healthy Adult Dogs

  • Han, Sung-Hyun;Yun, Mun-Su;Song, Kunho
    • Journal of Veterinary Clinics
    • /
    • v.39 no.2
    • /
    • pp.45-50
    • /
    • 2022
  • Vertebral left atrial size can be used as a radiographic tool to evaluate left atrial size in dogs. Vertebral left atrial size has been studied in dogs; however, few studies have been conducted on breed-specific differences in healthy dogs. To study the median vertebral left atrial size differences by breed and to investigate the association between age, sex, body condition score, thoracic depth-to-width ratio, and vertebral left atrial size. A total of 220 dogs of the following breeds: Maltese (n = 73), Beagle (n = 30), Poodle (n = 41), Shih-tzu (n = 44), and Mongrel (n = 32) were reviewed retrospectively. Sex, body weight, age, and body condition score of each dog were collected. Thoracic radiography was conducted for dorsoventral and right/left lateral views in all dogs to measure the vertebral heart score, vertebral left atrial size, and thoracic depth-to-width ratio. No significant differences in the median vertebral left atrial size were found among the breeds. There were no effects of sex, age, body condition score, and thoracic depth-to-width ratio on vertebral left atrial size. There was a significant positive correlation between the vertebral heart score and vertebral left atrial size. Breed, age, sex, and chest conformation did not correlate with vertebral left atrial size.