• Title/Summary/Keyword: Measure height

Search Result 781, Processing Time 0.031 seconds

Development of Mean Stand Height Module Using Image-Based Point Cloud and FUSION S/W (영상 기반 3차원 점군과 FUSION S/W 기반의 임분고 분석 모듈 개발)

  • KIM, Kyoung-Min
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.4
    • /
    • pp.169-185
    • /
    • 2016
  • Recently mean stand height has been added as new attribute to forest type maps, but it is often too costly and time consuming to manually measure 9,100,000 points from countrywide stereo aerial photos. In addition, tree heights are frequently measured around tombs and forest edges, which are poor representations of the interior tree stand. This work proposes an estimation of mean stand height using an image-based point cloud, which was extracted from stereo aerial photo with FUSION S/W. Then, a digital terrain model was created by filtering the DSM point cloud and subtracting the DTM from DSM, resulting in nDSM, which represents object heights (buildings, trees, etc.). The RMSE was calculated to compare differences in tree heights between those observed and extracted from the nDSM. The resulting RMSE of average total plot height was 0.96 m. Individual tree heights of the whole study site area were extracted using the USDA Forest Service's FUSION S/W. Finally, mean stand height was produced by averaging individual tree heights in a stand polygon of the forest type map. In order to automate the mean stand height extraction using photogrammetric methods, a module was developed as an ArcGIS add-in toolbox.

The Performance Analysis and Design of Selling Spectacle Lenses in Domestic Market (국내 시판 안경렌즈의 성능 분석 및 설계)

  • Kim, Se-Jin;Lim, Hyeon-Seon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.355-360
    • /
    • 2010
  • Purpose: Analysis performance for spectacle lens which sales in domestic market and optimization design a spectacle lens which is corrected aberration. Methods: Measured center thickness, radius and aspherical surface coefficient for spherical and aspherical lenses which were ${\pm}$5.00D. Refractive index for every lens was 1.6 and they came from 4 different companies. I used 3 types of equipment to measure lenses. ID-F150 (Mitutoyo) : Center Thickness, FOCOVISION (SR-2, Automation Robotics) : Radius, PGI 1240S (Taylor Hobson) : Aspherical surface coefficient. Designed a lens which had 27 mm of distance from lens rear surface to center of eye, 4 mm of pupil diameter and small aberration on center vision $30^{\circ}C$. To shorten axial distance compared with the measured lens rise merits for cosmetic. Lens Design tool was CODE V (Optical Research Associates). Results: -5.00D aspherical lens had somewhat high astigmatism and distortion compared with the spherical lens. But it had a merit for cosmetic because of short axial height and decrease edge thickness. Improved a performance of distortion and ascertain merits for cosmetic due to short axial height and decrease edge thickness same as (-) lens in case of +5.00 aspherical lens. Though an optimization process front surface aspherical lens had a good performance for astigmatism and distortion and the merit for beauty compared with measured spherical lens. Conclusions: Design trend for domestic aspherical lens is decrease axial height and thickness to increase a merit for cosmetic not but increase performance of aberration. From design theory for optimization design front surface aspherical spectacle lens which has improved performance of aberration and merit for cosmetic at the same time compared with the measured lens. Expect an improved performance from design back aspherical lens compared with front aspherical lens.

Influence of Fluid Height and Structure width ratio on the Dynamic Behavior of Fluid in a Rectangular Structure (사각형 구조물에 저장된 유체의 동적거동에 유체높이와 구조물 폭의 비가 미치는 영향)

  • Park, Gun;Yoon, Hyungchul;Hong, Ki Nam
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.126-134
    • /
    • 2020
  • In the case of an earthquake, the fluid storage structure generates hydraulic pressure due to the fluctuation of the fluid. At this time, the hydraulic pressure of the fluid changes not only the peaked acceleration of the earthquake but also the sloshing height of the fluid free water surface. Factors influencing this change in load include the shape of the seismic wave, the maximum seismic strength, the size of the fluid storage structure, the width of the structure, and the height of the fluid. In this study, the effect of the ratio between the height of the fluid and the width of the structure was investigated on the fluctuation characteristics of the fluid. 200mm and 140mm of fluid were placed in a water storage tank with a width of 500mm, and a real seismic wave was applied to measure the shape of the fluctuation of the fluid free water surface. The similarity between the experiment and the analysis was verified through the S.P.H(Smoothed Particle Hydrodynamic) technique, one of the numerical analysis techniques. It was confirmed that the free water surface of the fluid showed a similar shape, through comparison of experiment and analysis. And based on this results, SPH technique was applied to analyze the fluctuation shape of the fluid free water surface while varying the ratio between the fluid height and the structure width. An equation to predict the maximum and minimum heights of the fluid free water surface during an earthquake was proposed, and it was confirmed that the error between the maximum and minimum heights of the fluid free water surface predicted by the proposed equation was within a maximum of 3%.

The Study of Verification Bi-Digital O-Ring Test by gauges (계측기(計測器)를 이용한 O-Ring Test법(法)의 검증(檢證)에 관(關)한 연구(硏究))

  • Kim, Jeong-Ryeol;Kim, Dal-Rae
    • The Journal of Korean Medicine
    • /
    • v.16 no.2 s.30
    • /
    • pp.225-247
    • /
    • 1995
  • Using Bi-Digital O-Ring Test which was developed by Ohmura Toshiaki, constiution classification by the vegetables' was Measured by various muscle power measurement meters and the results are as follow: 1. Pinch Gauge (Model:pc5030HPG, Japan) is the gauge to measure finger power between the thumb and the second finger, Grip Strength Dynamometer (Model: T.K.K. 5101, Japan) is to measure the hand power (hand dynamometer), Back Strength Dynamometer (Model: T.K.K. 5102, Japan) is to measure back muscle strength, Vertical jump Meter (Model: T.K.K. 5106, Japan) is to measure the height of jump. The above gauges were and its result found that the radish, potato, carrot and cucumber can influence to muscle strength was not true. 2. When the physical constitution is distinguished by the O-Ring Test method, Taeyangin's rate appeared as average 21% although it was insisted that there will be only 0.03-0.1%. This means that the physical constitution but it appears accidently according to the examinee's emotion about the material such as vegetable etc. as favor or unfavor. 3. It was found that the result of O-Ring Test is the same at any time and at any place was not true. there is no reemergence character. 4. The import of O-Ring Test mehtod to the physical discrimination disregarded that the mental factor influences absolutely to the physical heath in the ideological physi cal constitution medical science. 5. 'O-Ring Test method is a objective judgement method.' is wrong judgement. As you see on the above result, Bi-Digital O-Ring Test set the changeable voluntary muscle as the standard of the judgument, that was first mistake logically, second in spite of leass influence of mental influence by the examiner and examinee than the vegetable discrimination influence, the test disregarded the influence. Third, only grasp of some material on hand can influence to the voluntary muscle was a wrong theory disregarding the physiology. Finally the misunderstaning his subjective view as an objective view in spite of examiner and examinee's strong influence. Therefore such kind of physical descrimination method must be sublated.

  • PDF

Respiratory Functions and Characteristics of Phonation in Patients with de novo Idiopathic Parkinson's Diseases (de novo 특발성 파킨슨병 환자의 호흡 및 발성 특성)

  • Cho, Sun-A;Sohn, Young-Ho;Baek, Seung-Jae;Lee, Phil-Hyu;Lee, Ji-Eun;Choi, Yae-Lin
    • Phonetics and Speech Sciences
    • /
    • v.2 no.4
    • /
    • pp.75-82
    • /
    • 2010
  • Many previous studies based on respiratory characteristics of Idiopathic Parkinson's Diseases (IPD) patients have not controlled related factors appropriately. Accordingly, these studies produced discordant results. Furthermore, there is currently a lack of studies that can provide precise explanations on the characteristics of respiration and phonation. This study included a total of 40 subjects: 20 mixed gender de novo IPD patients ranging in age from 50 to 80 (Hoehn & Yahr stage 1~3), and 20 normal subjects with similar matches for age and gender. All participants were controlled based on their gender, age, height, weight, vocal fold function, cognitive abilities, and depression factors. K-MMSE (Korean-Mini Mental State Examination), nVHI-10 (new Voice Handicap Index), and KGDS (Korean Form of Geriatric Depression Scale) were evaluated to select this study subjects. In order to compare respiratory functions between the two groups, FVC, FEV1, and FEV1/FVC were measured using microQuark, a PC-based spirometer. CSL was used by measure MPT and PAS was used to measure MFR. To investigate the characteristics of phonation ability, CSL was used to measure jitter and shimmer, while PAS was used to measure Psub. In order to compare the respiratory function averages and phonation ability between the two groups, statistical analysis was conducted using SPSS (version 12.0). The results of this study showed that most de novo IPD patients were included in the normal average range of respiratory and phonatory ability. But the respiratory and phonatory ability of de novo IPD patients showed lower tendency as compared with the normal group. When the average of respiratory and phonatory ability among the gender was compared, the difference of males was greater than the difference of females.

  • PDF

The Effects of the Height and the Quality of the Material of Popular Heel-up Insole on the Mean Plantar Foot Pressure during Walking (보행시 보급형 키 높이 인솔의 높이와 재질이 평균 족저압에 미치는 영향)

  • Lee, Joong-Sook;Kim, Doo-Hwan;Jung, Bu-Won;Han, Dong-Wook;Park, Don-Mog
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.479-486
    • /
    • 2011
  • This study determined the effects of the height and the quality of the material of popular heel-up insole on mean plantar foot pressure during walking. Seven healthy college students who are studying at S university in Busan were as participants in this study. After sufficiently explaining about the research to the subjects before the experiment, mean plantar foot pressures were examined using F-Scan Pressure Measure System 5.23 for the gait with shoes inserted insole and the data were compared among the height and the quality of material of insoles. In the result, there was a difference significantly in the mean plantar foot pressure followed the height of insoles both left and right. Especially, mean plantar foot pressure in left indicated significantly lower in 3 cm and 5 cm insoles than in 0 cm and 1 cm insoles. Also mean plantar foot pressure in right showed significantly lower in 3 cm and 5 cm insoles than in 0 cm, and indicated significantly lower in 5 cm insoles than in 1 cm and 3 cm insoles. The mean plantar foot pressure followed the quality of the material of insoles were different significantly. In left, the mean plantar foot pressure of urethane poly-acetyl insole was lower significantly than urethane poly-acetyl inserted air insole, power-gel insole and jelly insole. And the mean plantar foot pressure of urethane poly-acetyl insole was lower significantly than power-gel insole and jelly insole in right. We showed that 3 cm and 5 cm insoles in the height of insoles and Urethane poly-acetyl insole in the quality of material were suitable to reduce a fatigue which is felt in plantar foot during the walking.

A Study on Detection of Overloaded Vehicles at Highway Toll Gates Using Detection of Height Changes in Vehicle Cargo Boxes (차량 적재함의 높이 변화 감지를 이용한 고속도로 톨게이트 과적차량 검출에 관한 연구)

  • Gwang Lee;Bong-Keun Kim
    • Journal of Practical Engineering Education
    • /
    • v.16 no.3_spc
    • /
    • pp.391-399
    • /
    • 2024
  • All highway toll gates in Korea use low-speed WIM(Weight-In-Motion) to block overloaded cargo vehicles from entering the main highway, but some cargo vehicle owners are illegally modifying vehicles to operate variable axles and evading crackdowns by manipulating the axles. In previous studies detect all tires of a running vehicle were detected to determine whether there is axle manipulation. However, because the vehicle entry area at the highway toll gate checkpoint is very narrow, there is a problem that it is realistically difficult to film all tires of the entering vehicle in one video frame. In this paper, we proposed a system that can determine whether the axle is being operated through changes in the height of the vehicle's cargo box rather than by detecting tires. To detect changes in the height of a cargo box, we propose a method to extract the representative line of the cargo box using Hough transform and then measure the change in height of the representative line to detect the change in height of the cargo box. In addition, we propose a method to detect changes in the vertical height of a cargo box by accumulating motion vectors of pixels within a certain area of the image using optical flow. And the two methods were compared and their advantages and disadvantages were analyzed and presented.

BMI, Weight Control Behavior, and Self-esteem in High School Adolescents (남녀 고등학생들의 비만도, 체중조절행위, 자아존중감에 대한 비교연구)

  • Kim, Ok-Soo;Kim, Sun-Wha;Kim, Ae-Jung
    • Korean Journal of Adult Nursing
    • /
    • v.14 no.1
    • /
    • pp.53-61
    • /
    • 2002
  • Purpose: This descriptive study was designed to investigate Body Mass Index(BMI), weight control behavior, and self-esteem in high school adolescents. Method: The convenience sample consisted of 129 high school females and 106 high school males. Data were collected using a self-report questionnaire from November to December, 1999. BMI was calculated by using the subject's self-reported body weight and height to identify objective obesity. Self evaluation about subjective obesity was measured by a single item question. Preferred BMI was calculated by using the subject's elf-reported body weight and height which the subjects desired. The Rosenberg's Self-Esteem Scale was utilized to measure the level of self-esteem. Results: Results of the study revealed that high school females perceived themselves as more more obese than their the actual BMI, excessively participated in dieting behavior and exercises, and reported lower self-esteem than that of males. Conclusion: Based on this study, health care providers need to educate female adolescents about healthy behavior as well as the normal weight range in BMI.

  • PDF

Experimental Study on the Whirling, Tilting and Flying Motion of the FDB Spindle System of a 3.5' HDD (3.5인치 HDD용 FDB스핀들 시스템의 훨링, 플라잉과 틸팅 거동에 관한 연구)

  • Oh, S.H.;Lee, S.H.;Jang, G.H.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.1 s.94
    • /
    • pp.39-45
    • /
    • 2005
  • This research develops an experimental method to measure the motion of a FDB spindle system with a 3.5' disk by using three capacitance probes fixed on the xyz-micrometers, and it shows that a FDB spindle system has the whirling, flying and tilting motion. It also shows that the whirling, flying and tilting motion converge very quickly to the steady state at the same time when the rotor reaches the steady-state speed. However, they are quite large even at the steady state when they are compared with the 10nm flying height of a magnetic head. For the FDB spindle system used in this experiment, the whirl radius and the peak-to-peak variation of flying height and tilting angle at the steady-state speed of 7,200rpm are 0.675m, 30nm and $5.758\times10^{-3^{\circ}}$, respectively, so that the radial motion of the FDB spindle system exceeds a track pitch of a 3.5' HDD with 90,000 TPI.

Effects of Soy Isoflavone Supplementation and Exercise on Bone Mineral Density and Urinary Deoxypyridinoline in Postmenopausal Women (폐경 후 여성에서 대두 이소플라본 공급 및 운동처방이 골밀도 및 소변 디옥시피리디놀린에 미치는 영향)

  • 승정자;윤미은;이재구;김미현;이행신
    • Journal of Nutrition and Health
    • /
    • v.37 no.4
    • /
    • pp.291-301
    • /
    • 2004
  • We studied the effects of soy isoflavones supplementation with exercise on bone mineral density and the urinary excretion of deoxypyridinoline as an index of bone resorption rates in postmenopausal women. A total of 67 postmen-opausal women were assigned to Isoflavone (90 mg/day) or placebo groups. These group were further divided into groups that undergone a regular exercise or a rather sedentary state performing daily activity only. Four groups were Placebo-control group (n = 16), Placebo-exercise group (n = 16), Isoflavone-sedentary group (n = 19) and Isofla-vone-exercise group (n = 16). After the intervention, we compared anthropometric mesurement, dietary recall, bone mineral density (femoral neck, lumbar spine), urinary deoxypyridinoline between the groups and between the pre and post studies. There were no significant differences between the four groups in terms of average age, height, weight, period after menopause at the baseline. The average age of the subjects were 55.2 yrs, average height, weight, period after menopause were 154.7 cm, 59.3 kg, 5.58 yrs, respectively. After eight week intervention period, there were no significant differences between the four groups in bone mineral density, but urinary deoxypyridinoline excretion was significantly decreased both in Isoflavone-sedentary and Isoflavone-Exercise groups. These results suggest that Isofla-vone supplementation alone or with exercise may be preventive measures through the decrease of bone reabsorption rate in post-menopausal subjects. Whereas exercise alone did not appear to be an effective measure in bone loss with these subjects.