• 제목/요약/키워드: Mean-line Analysis

검색결과 442건 처리시간 0.031초

Validation on Residual Variation and Covariance Matrix of USSTRATCOM Two Line Element

  • Yim, Hyeon-Jeong;Chung, Dae-Won
    • Journal of Astronomy and Space Sciences
    • /
    • 제29권3호
    • /
    • pp.287-293
    • /
    • 2012
  • Satellite operating agencies are constantly monitoring conjunctions between satellites and space objects. Two line element (TLE) data, published by the Joint Space Operations Center of the United States Strategic Command, are available as raw data for a preliminary analysis of initial conjunction with a space object without any orbital information. However, there exist several sorts of uncertainties in the TLE data. In this paper, we suggest and analyze a method for estimating the uncertainties in the TLE data through mean, standard deviation of state vector residuals and covariance matrix. Also the estimation results are compared with actual results of orbit determination to validate the estimation method. Characteristics of the state vector residuals depending on the orbital elements are examined by applying the analysis to several satellites in various orbits. Main source of difference between the covariance matrices are also analyzed by comparing the matrices. Particularly, for the Korea Multi-Purpose Satellite-2, we examine the characteristics of the residual variation of state vector and covariance matrix depending on the orbital elements. It is confirmed that a realistic consideration on the space situation of space objects is possible using information from the analysis of mean, standard deviation of the state vector residuals of TLE and covariance matrix.

혈장 lipoprotein lipid의 NMR spectrum 분석 - 메틸기 및 메털렌기의 line width에 의한 악성 종양 진단 - (NMR Spectrum Analysis of Plasma Lipoprotein Lipid)

  • 송인찬;민병구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1296-1300
    • /
    • 1987
  • NMR spectrum analysis is performed to obtain the preliminary data for cancer detection. As NMR spectrum of plasma is dominated by the resonances of water, the resonances of plasma lipoprotein lipid is obscured by the water resonance. Thus, we can obtain the signal of plasma lipoprotein lipid using Ultracentrifugation. we analyzed the spectrum measuring the mean line widths of the methyl and methylene resonances for normal control group. As a result, the line width was Hz To obtain a potentially valuable approach to the detection of cancer, the performance of additional clinical trials in larger populations will be made.

  • PDF

3차원 축류형 터빈익형의 공력설계에 관한 연구 (A Study on the Aerodynamic Design of Three-Dimensional Axial Type Turbine Blade)

  • 장범익;김동식;조수용
    • 동력기계공학회지
    • /
    • 제5권3호
    • /
    • pp.38-47
    • /
    • 2001
  • One stage axial type turbine is designed by mean-line analysis, streamline curvature method and blade design method using shape parameters. Tip and hub diameter of the turbine are 300mm and 206.4mm, respectively. The rotating speed is 1800RPM, and the output power is 1.4kW. The flow coefficient is 1.68 and the reaction factor at mean-line is 0.373. The number of stator and rotor of the turbine are 31 and 41, respectively. Mach number of stator exit flow near hub is 0.164. A test rig is developed for performance test to validate a developed design method. The experimental result shows that the maximum efficiency is obtained on the design point.

  • PDF

상완부 및 진동형태에 관한 연구 (A Study on the Shape of the Upper Arm and the Armscye Line)

  • 김순분
    • 복식
    • /
    • 제30권
    • /
    • pp.201-210
    • /
    • 1996
  • The perpose of this study is to compare and to analyze the characters of the shape of up-per arm and armscye line between young and aged women. The subjects were measured with the Mar-tin's anthropometer and with free curve ruler. 10 items in the shape of upper arm were measured and 16 items in the shape of armscye line measured indirectly based on the measured shape taken from the subjects with free curve ruler and both date were analyzed. Mean standard deviation f-test factor analysis were performed for the statistical analysis of the date. The main results were as follows: 1) The shape of the upper arm is long and narrow in youg women compared with aged. 2) The length of the axilla of the aged women were longer than that of young women. 3) There are significant differences young and aged women on the shape of armscye line. THe length of from the front point of axilla to shoulder point width and depth of the shape of the armscye line length of axilla of aged women were longer than that of young. but the length of from the back point of axilla to shoulder point of yyoung women was longer than aged. 4.) The front point of axilla was existed lower than back point of axilla in aged women while front point of axilla was existed higher than the back point in young. 5) Through the factor analysis two factors were obtained from the shape of the upper arm and five factors from the shape on armmscye line in both groups. Factor compornents in the shape of the up per arm were length width and girth of that and in the shape of the armscye line were width and length of upper and lower back and front part of the shape of the armscye line depth of the axilla. he items in the same factor were resemble each other between two groups.

  • PDF

Treatment Patterns, Costs, and Survival among Medicare-Enrolled Elderly Patients Diagnosed with Advanced Stage Gastric Cancer: Analysis of a Linked Population-Based Cancer Registry and Administrative Claims Database

  • Karve, Sudeep;Lorenzo, Maria;Liepa, Astra M;Hess, Lisa M;Kaye, James A;Calingaert, Brian
    • Journal of Gastric Cancer
    • /
    • 제15권2호
    • /
    • pp.87-104
    • /
    • 2015
  • Purpose: To assess real-world treatment patterns, health care utilization, costs, and survival among Medicare enrollees with locally advanced/unresectable or metastatic gastric cancer receiving standard first-line chemotherapy. Materials and Methods: This was a retrospective analysis of the Surveillance, Epidemiology, and End Results-Medicare linked database (2000~2009). The inclusion criteria were as follows: (1) first diagnosed with locally advanced/unresectable or metastatic gastric cancer between July 1, 2000 and December 31, 2007 (first diagnosis defined the index date); (2) ${\geq}65$ years of age at index; (3) continuously enrolled in Medicare Part A and B from 6 months before index through the end of follow-up, defined by death or the database end date (December 31, 2009), whichever occurred first; and (4) received first-line treatment with fluoropyrimidine and/or a platinum chemotherapy agent. Results: In total, 2,583 patients met the inclusion criteria. The mean age at index was $74.8{\pm}6.0years$. Over 90% of patients died during follow-up, with a median survival of 361 days for the overall post-index period and 167 days for the period after the completion of first-line chemotherapy. The mean total gastric cancer-related cost per patient over the entire post-index follow-up period was United States dollar (USD) $70,808{\pm}56,620$. Following the completion of first-line chemotherapy, patients receiving further cancer-directed treatment had USD 25,216 additional disease-related costs versus patients receiving supportive care only (P<0.001). Conclusions: The economic burden of advanced gastric cancer is substantial. Extrapolating based on published incidence estimates and staging distributions, the estimated total disease-related lifetime cost to Medicare for the roughly 22,200 patients expected to be diagnosed with this disease in 2014 approaches USD 300 millions.

Spinal Deformity Detection Based on the Evaluation of Middle Line´s Displacement on a Moire Image of a Human Back

  • Kim, Hyoungseop;Seiji Ishikawa;Yoshinori Otsuka;Hisashi Shimizu;Takashi Shinomiya
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.105.1-105
    • /
    • 2001
  • In this paper, a technique is described for classifying normal cases and abnormal cases in automatic spinal deformity detection by computer based on moire topographic images of human backs. Displacement is evaluated statistically between the middle line extracted from the entire moire image and the middle line obtained from a small rectangle area defined on the moire image. The middle line is calculated employing a developed potential symmetry analysis technique. The displacement is calculated in several regions and the mean and the standard deviation of the displacement values are chosen as two features. A linear discriminant function (LDF) is defined on the 2-D feature space based on the Mahalanobis distance and the features are classified into two categories, i.e., normal and ...

  • PDF

INFLUENCE OF CONVECTION ON LINE ASYMMETRIES

  • Park, Yong-Sun;Yun, Hong-Sik
    • 천문학회지
    • /
    • 제19권1호
    • /
    • pp.15-31
    • /
    • 1986
  • We have analyzed Gray's observed mean line bisectors of FS, G0, G2, and G5 normal dwarf stars and interpreted them by computing theoretical line bisectors based on a two stream model. A set of perturbed models has been derived, and their detailed structures on temperature fluctuations and velocity fields are presented as a function of depth, which account for the observed bisectors. From the present study, it is found that the degree of stellar convective overshootings and temperature fluctuations in the upper atmospheres increases towards earlier spectral types. The convection cell size inferred from these models is found to increase also with the advancing earlier type. We demonstrated the usefulness of line bisector analysis as a diagnostic probe for stellar convection.

  • PDF

패킷에 우선도가 있는 토큰링 LAN에서의 평균대기시간의 근사해석 (Approximated Analysis of Mean Waiting Time in Packet Based Priority Token Ring LAN)

  • 김영동;이재호
    • 한국통신학회논문지
    • /
    • 제14권5호
    • /
    • pp.453-461
    • /
    • 1989
  • Bux의 우선도가 없는 토큰링 LAN의 해석 결과와 Cobham의 HOL 우선도의 해석 결과를 사용해서 패킷에 우선도가 있는 토큰링 LAN의 각 노드에서의 각 우선도에 대한 평균대기시간을 근사적으로 해석하였다. IEEE 802.5에 제시된 토큰링 LAN에서의 우선도 예약전송방법은 사용하지 않았다. 본 논문에서 해석한 수학적 결과와 시뮬레이션 결과를 비교하여 +-5%정도의 상대오차율을 확인하였다. 트래픽의 세기, 노드수, 패킷길이, 전송속도, 회선길이, 토큰검색시간, 우선도 동급수, 트래픽 집중율 변화에 따른 각 우선도의 지연을 분석하였다.

  • PDF

자동열차제어장치 AF궤도회로 S-BOND의 사용신뢰도 분석 (Field Reliability Analysis of S-Bond of AF Track Circuit for Automatic Train Control System)

  • 최규형;고영환
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.308-313
    • /
    • 2009
  • This paper presents a reliability analysis of S-bonds for AF track circuits, which detect train movement and transmit a speed control signal to the train. Field survey shows that S-bonds are exposed to very large vibrations transferred from rail, and suffer from frequent failures when they were installed on ballasted track. We collected the time-to-failure data of S-bonds from the maintenance field of Seoul metro line 2, and made a parametric approach to estimate the statistical distribution that fits the time-to-failure data. The analysis shows that S-bonds have time-to-failure characteristics described by Weibull distribution. The estimated shape parameter of Weibull distribution is 1.1, which means the distribution has constant failure rate characteristics like exponential distribution. The reliability function, hazard function, percentiles and mean lifetime are derived for maintenance support.

디지털 영상인식 방법을 통한 자세평가 및 운동가동범위 측정시스템 개발 (Development of Posture Evaluation System through Digital Recognition Method)

  • 문영진;이순호;백진호;이종각;이건범
    • 한국운동역학회지
    • /
    • 제14권3호
    • /
    • pp.49-65
    • /
    • 2004
  • The purpose of this study is development of posture evaluation and Range of Motion(ROM) system by using digital vision analysis method. The results of this study are as follows. First, Scoliosis evaluation through this research measurement system represent 3mm error in 7 cervical point and deepest lumbar point, 0.7mm error in other point. This mean this research measurement system have a reliability for scoliosis evaluation. Second, for spine line evaluation on high fat subject, we need reconstrection spine line after measurement for fat thickness in 7 cervical point and deepest lumbar point. Third, In pedioscope error test, it present 0.01848cm in X axis and 0.01757cm in Y axis. This results mean pedioscope have a reliability foot evaluation. Forth, Posture evaluation and Range of Motion measurement system by using digital vision analysis method can fast measure in range of motion and foot evaluation and posture. therefore we can expect this system application in young people posture clinic center and hospital and so on.