• 제목/요약/키워드: Mean transit time

검색결과 63건 처리시간 0.032초

미주신경간절제술에 있어서 $^{99m}Tc-DISIDA$ 신티그램을 이용한 총수담관 및 Afferent loop의 평균지연시간 (The Mean Transit Time of the CBD and the Afferent Loop Using $^{99m}Tc-DISIDA$ Scintigram in Truncal Vagotomy)

  • 문태용;김동수
    • 대한핵의학회지
    • /
    • 제22권2호
    • /
    • pp.199-203
    • /
    • 1988
  • The authors observed functional change of the CBD and the afferent loop with the transit time of $^{99m}Tc-DISIDA$ scintigram in patients treated by the surgical operation of gastric ulcers and cancer at Busan National University Hospital from June, 1987 to April, 1988. So authors estimated the time between the peak activity of the CBD and the afferent loop (TCA), the half transit time of the CBD activity (t 1/2 CBD) and the half transit time of the afferent loop activity (t 1/2 A-loop) in 9 patients undergone truncal vagotomy, who have no specific symptoms at 2 to 6 months after the operation, 5 patients undergone the operation without truncal vagotomy, and 7 persons as a control group. The results were as follows: I) In control group, the mean TCA, t 1/2 CBD and t 1/2 duodenum were $8.6{\pm}9.0$ min, $38.7{\pm}17.3$ min. and $28.6{\pm}10.9$ min, respectively. 2) In the operation group without truncal vagotomy, the mean TCA, t 1/2 CBD and t 1/2 A-loop were $10.0{\pm}7.1$ min. $48.2{\pm}22.3$ min. and $39.4{\pm}26.7$ min. respectively. 3) In the operation group with truncal vagotomy, the mean TCA, t 1/2 CBD and t 1/2 A-loop were $15.0{\pm}8.7$ min., $36.1{\pm}16.5$ min. and $42.6{\pm}24.4$ min, respectively. From the above results, we concluded that the transit time of the CBD and the afferent loop is not affected by truncal vagotomy.

  • PDF

천구 및 지구의 침 자극이 노인 변비의 대장 통과시간에 미치는 영향 (The Effects of Acupuncture(ST25, TE6) Stimulation on Colonic Transit Time in Old Age Constipation Persons)

  • 황상일;이윤재;임은경;정현애;문미현;조영기;이성균;김동웅
    • 동의생리병리학회지
    • /
    • 제18권1호
    • /
    • pp.220-225
    • /
    • 2004
  • We undertook this study to investigate the effects of acupuncture and electroacupuncture on colonic transit time in old age constipation persons. Twenty three volunteers were old age constipation persons(mean age 69.72±2.43 years, mean defecation rate 1.83±0.41/week). Before acupuncture was only to check the radio-opaque markers transit time all the way through gastrointestinal tract. Simple acupuncture was to apply acupuncture therapy for three days. The fourth acupoints(both ST.25, TE.6) were selected and the needle was kept for 15 minutes. Electroacupuncture was same as the simple acupuncture except for applying 2Hz electrical stimulation. After Then we compare with three method Each transit time in the whole colon, right colon, left colon and rectosigmoid colon were checked in the order of before acupuncture, simple acupuncture, and electroacupuncture stimulation. In the before acupuncture stimulation, the transit time in each part of colon was as follows 19.48±1.76 32.74±2.69 25.61±2.13 76.62±7.95 hours. Simple acupuncture stimulation, the transit time was 17.47±1.10 33.10±1.87 24.12±1.65 74.87±3.91 hours. Compared with before acupuncture stimulation, the transit time was significantly shortened(P<0.05), especially in right colon transit time of simple acupuncture stimulation was significantly shortened(P<0.05). Electroacupuncture stimulation, was 16.32±1.97 32.91±2.48 21.53±1.94 71.59±2.82. Compared with the previous two trial, transit time in right colon and rectosigmoid colon were significantly shortened(P<0.05). Acupuncture and electroacupuncture stimulation change on the right colonic transit time in old age constipation persons and rectosigmoid colonic transit time was changed as electroacupuncture stimulation. In other words, old age constipation persons who suffer chronic constipation, acupuncture and electroacupuncture stimulation reduces the total colonic transit time.

A Method to Estimate Peripheral Systolic Blood Pressure using Pulse Transit Time during Bicycle Ergometer Exercise of Healthy Korean Subjects in their Twenties

  • Lee Jeong-Chan;Eo Yun-Hye;Park Kyung-Mo;Park Seung-Hun
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권3호
    • /
    • pp.89-93
    • /
    • 2006
  • A simple algorithm that can be used to estimate a healthy person's blood pressure using pulse transit time is proposed in this paper. Fifty healthy students participated in the experiment that was conducted in line with the study. The subjects were asked to exercise on several exercise levels using a bicycle ergometer. Their blood pressures during the succeeding rest period were measured. A simple method was proposed to illustrate the relationship between blood pressure and pulse transit time. The systolic blood pressures as well as the heights and weights of the subjects were regarded as the proper parameters, and a second-order regression curve was produced to estimate the subjects' blood pressures. The mean error of estimation was less than 10 mmHg, which was the mean error of manual measurement. Although our estimation model is so simple, it can be used to estimate continuous blood pressure measurement for bicycle ergometer exercise. The electrocardiograms, photoplethysmograms, and blood pressures, however, could not be measured simultaneously As such, their estimation may be slightly different from the results taken from simultaneous measurements.

유동식 및 고형식을 이용한 동위원소 식도통과검사의 임상적 의의에 대한 연구 (Clinical Evaluation of Radionuclide Esophageal Transit Studies using Liquid and Solid Foods)

  • 최재걸;이민재;서원혁;송치욱;현진해
    • 대한핵의학회지
    • /
    • 제29권1호
    • /
    • pp.61-72
    • /
    • 1995
  • The author performed radionuclide esophageal transit studies(RETS) with liquid and solid boluses using the same day protocol in 90 normal controls and 164 patients with various primary esophageal motility disorders who were diagnosed by manometric criteria and clinical courses. The authors calculated mean esophageal transit time(MTT) and mean residual retention(MRR) in each of the liquid and solid studies, and classified time-activity curve(TAC) patterns. The normal criteria of RETS with liquid bolus were MTT<24 sec, MRR<9%, and the TAC pattern that showed rapid declining slope and flat low residual(Type 1). The normal criteria of RETS with solid bolus were MTT<35 sec, MRR<9% and TAC of type 1. With these normal criteria, the sensitivity and the specificity of the liquid study were 62.2 % and 97.8%, respectively. The sensitivity increased to 75.4% with the solid study. The author also found that the RETS was highly reproducible. The achalasia typically showed no effective emptying of both liquid and solid boluses during the whole study period, and was well differentiated by its extremely long transit time and high retention from the other motility disorders. The diffuse esophageal spasm (DES) and nonspecific esophageal motility disorder(NEMD) showed intermediate delay in transit time and increased retention. In the groups of hypertensive lower esophageal sphincter(LES), hypotensive LES and nutcracker, there noted no significant difference with the normal control group in terms of MTT and MRR. The DES and NEMD could be more easily identified by solid studies that showed more marked delay in MTT and increased MRR as compared with the liquid study. In conclusion, esophageal scintigraphy is a safe, noninvasive and physiologic method for the evaluation of esophageal emptying.

  • PDF

지구의 기준선 “그리니치”(I) (Prime Meridian of the World - Greenwich)

  • 윤경철
    • 기술사
    • /
    • 제36권6호
    • /
    • pp.72-77
    • /
    • 2003
  • The Royal Observatory Is the Prime Meridian of the world and of Greenwich Mean Time. All time and space is measured relative to Longitude Zero1000" 00' 00" )which is defined by the crosshairs of the great Transit Circle telescope in the Meridian Building of the Observatory Greenwich Mean Time. GMT is the basis for the international Time Zone System

  • PDF

자기부상열차 RAM DATA 관리방안 (Review on RAM Data Management to Urban Maglev Transit)

  • 이창덕;강찬용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.191-196
    • /
    • 2007
  • This paper is reviewed RAM(Reliability, Availability and Maintainability) data table utilized for RAM data management to Urban Maglev Transit. As railway systems become more complex, the RAM requirements are reinforced to ensure that a design meets Reliability, Availability, Maintainability criteria. Therefore, it needs the efficient management for RAM data of railway system to meet RAM target. At this study, RAM data management format is suggested to ensure reliability and maintainability based on acquired experience for overseas rolling stock. This RAM data table and FMECA(Failure Mode Effect Criticality Analysis) table are useful to the calculation of MTBF(Mean Time Between Failure), MTBSF(Mean Time Between Service Failure) and Maintainability. Also, this RAM management table will be efficient to improve the RAM evaluation to Urban Maglev Transit.

  • PDF

쇄빙상선의 북극해 항로 항행 모델링 (The Northern Sea Route Transit Modeling of Icebreaking Cargo Vessels)

  • 정성엽;최경식
    • 대한조선학회논문집
    • /
    • 제44권3호
    • /
    • pp.340-347
    • /
    • 2007
  • Main purpose of the study is to develop a transit model for icebreaking cargo vessels in the Northern Sea Route and to select optimum sea routes with the shortest navigation time and the lowest operation cost. This numerical model executed with basic information such as ship capabilities, transit directions and months of transit, can calculate total transit distance and elapsed time, mean speed, operation cost for each vessel. In the transit model. environment information such as the site-specific ice conditions, wave and wind states are utilized for four different months (April, June, August, and October) along the Northern Sea Route. The model also defines a necessary period of an icebreaker escort. Then the optimum sea routes are selected and visually displayed on the digital map using a commercial software ArcGIS. Usefulness of the selected sea routes is discussed.

Estimating blood pressure using the pulse transit time of the two measuring from pressure pulse and PPG

  • 김기련;예수영;김재형;전계록
    • 센서학회지
    • /
    • 제17권2호
    • /
    • pp.87-94
    • /
    • 2008
  • Blood pressure (BP), one of the most important vital signs, is used to identify an emergency state and reflects the blood flow characteristics of the cardiovascular system. The conventional noninvasive method of measuring BP is inconvenient because patients must wear a cuff on their arm and the measurement process takes time. This paper proposes an algorithm for estimating the BP using the pulse transit time (PTT) of the photoplethysmography (PPG) and pressure pulse from finger at the same time as a more convenient way to measure the BP. After recording the electrocardiogram (ECG), measuring the pressure pulse, and performing PPG, we calculated the PTT from the acquired signals. Then, we used a multiple regression analysis to measure the systolic and diastolic BP indirectly. Comparing the BP measured indirectly using the proposed algorithm and the real BP measured with a sphygmomanometer, the systolic pressure had a mean error of ${\pm}3.240$ mmHg and a standard deviation of 2.530 mmHg, while the diastolic pressure had a satisfactory result, i.e., a mean error of ${\pm}1.807$ mmHg and a standard deviation of 1.396 mmHg. These results are more superior than existing method estimating blood pressure using the one PTT and satisfy the ANSI/AAMI regulations for certifying a sphygmomanometer i.e., the measurement error should be within a mean error of ${\pm}5$ mmHg and a standard deviation of 8 mmHg. These results suggest the possibility of applying our method to a portable, long-term BP monitoring system.

말초혈관 혈류 측정을 이용한 비관혈적 혈압 추정법에 대한 연구 (Estimation of Non- Invasive Blood Pressure Using Peripheral Plethysmograph)

  • 정인철;신태민;윤형로
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권8호
    • /
    • pp.504-509
    • /
    • 2005
  • This paper presents a new method for obtaining the noninvasive and unrestrained blood pressure readings noninvasively and unrestrainedly using based on reflected wave arrival time(RAT) in the volume of pulse. Since this new method employs only volume pulse, is more rapider and simpler than the method using pulse transit time(PTT) because it only employs the volume of pulse. Blood pressure, PTT and RAT were acquired from 15 healthy subjects. Each subjects were performed forty trials of each measurement. As a result of those trials, the mean error between oscillometric and RAT measurements for systolic blood pressure was $4.55\pm5.64mmHg$. This result showed quite equal with the mean error between oscillometric and PPT measurf:ments, $4.22\pm5.30mmHg$, However, it was not obtained a satisfactory result in the relativity of oscillometric to both RAT and PPT measurements for diastolic blood pressure because of personal difference. To conclude, the method of systolic blood pressure estimation noninvasively and unrestrainedly using by RAT may be used as the method by PTT. Nevertheless, additional studies would be necessary for the RAT/PTT estimation of diastolic blood Pressure measurement.