• Title/Summary/Keyword: Mean temperature

Search Result 3,928, Processing Time 0.038 seconds

Evaluation of Pheromone Lure of Grapholita molesta (Lpidoptera: Torticidae) and Forecasting Its Phenological Events in Suwon (복숭아순나방 성페로몬 미끼 평가 및 수원지역에서 주요 발생시기 예찰)

  • Kim Dong Soon;Boo Kyung Saeng;Jeon Heung Yong
    • Korean journal of applied entomology
    • /
    • v.43 no.4 s.137
    • /
    • pp.281-289
    • /
    • 2004
  • The sex pheromone blend (28-12AC : E8-12AC : Z8-12OH = 95 : 5 : 1) of oriental fruit moth, Grapholita molesta (Busck), was evaluated with reference to its male attractivity at different dosage and lure longevity of 1.0 mg in a field condition. Also, degree-days (DD) were calculated up to major phenological events of G. molesta using seasonal adult flights monitored by pheromone traps and egg population densities in early season in Suwon peach orchards. In the range of 0.1-4.0 mg dosage examined, G. molesta males caught in pheromone trap decreased with increasing total pheromone doses. The highest number of G. molesta males were attracted in traps baited with 0.1 mg-lure, and there were no significantly differences among 0.5 to 4.0 mg-lure. In longevity test with a 1.0 mg-lure, there was no difference in mean numbers of G. molesta males caught between traps with fresh-baited lures every 20d and field-lasted lures up to ${\approx}50d$ after trap installation, but thereafter more G. molesta males were attracted in the field-lasted lures than in the fresh-baited lures. Accumulated degree-days (DD) from January 1 to the first adult emergence (biofix) were 39DD at a lower threshold temperature $8.1^{\circ}C$. Degree-days from the biofix up to the 1st adult peak through 4th peak were 98DD, 620DD, 1233DD, and 1916DD, respectively. Required degree-days from the 1st adult peak to the 1st egg peak were 130DD, while the 2nd egg peak timing was simultaneous with the 2nd adult peak. Further, management strategies of G. molesta were discussed in peach orchards.

Comparision of Blood Gas Analyser, pH Meter and pH Strip Methods in the Measurement of Pleural Fluid pH (흉수의 pH 측정에서 혈액가스분석기계, pH meter, pH Strip 방법의 비교)

  • Jee, Hyun-Suk;Park, Yong-Bum;Choi, Jae-Chol;Ahn, Chang-Hyuk;Yoo, Ji-Hoon;Kim, Jae-Yeol;Park, In-Won;Choi, Byoung-Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.773-780
    • /
    • 2000
  • Background : pH measurement is an important test in assessing the etiology of pleurisy and in identifying complicated parapneumonic effusion. Although the blood gas analyzer is the gold standard method' for pleural pH measurement, pH meter & pH strip methods are also used for this purpose interchangably. However, the correlation among the pH data measured by the three different methods needs to be evaluated. In this study, we measured the pH of pleural fluid with the three different methods respectively and evaluated the correlation among the measured data. Methods : From August 1999 to March 2000, we measured the pleural fluid pH in 34 clinical samples with three methods-blood gas analyzer, pH meter, and pH strip. In the blood gas analyzer and pH meter methods, the temperature of pleural fluid was maintained around $0^{\circ}C$ in air-tight condition before analysis and measurement was performed within 30 minutes after collection. As for the pH strip method, the pleural fluid pH was checked in the ward immediately after tapping and in the clinical laboratory of our hospital. This part is unclear. Results : The causes of pleural effusion were tuberculosis pleurisy in 16 cases, malignant pleural effusion 5 cases, parapneumonic effusion 9 cases, empyema 3 cases, and congestive heart failure 1 case. The pH of pleural fluid (mean$\pm$SD) was 7.34$\pm$0.12 with blood gas analyser, 7.52$\pm$0.25 with pH meter, 7.37$\pm$0.16 with pH strip of immediate measurement and 6.93$\pm$0.201 with pH strip of delayed measurement. The pH measured by delayed pH strip measurement was lower than those of other methods (p<0.05). The correlation of the results between the blood gas analyzer and pH meter(p=0.002, r=0.518) and the blood gas analyzer and pH strip of immediate measurement(p<0.001, r=0.607). Conclusion : In the determination of pH of pleural fluid, pH strip method could be a simple and reliable method under immediate measurement conditions after pleural fluid tapping.

  • PDF

Efficacy of Low-dose Hydrocortisone Infusion for Patients with Severe Community-acquired Pneumonia Who Invasive Mechanical Ventilation (기계 환기가 요구된 중증 지역사회 획득 폐렴에서 저용량 하이드로코르티손 주입의 효과)

  • Kim, Ho Cheol;Lee, Seung Jun;Ham, Hyoun Seok;Cho, Yu Ji;Jeong, Yi Yeong;Lee, Jong Deok;Hwang, Young Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.4
    • /
    • pp.419-425
    • /
    • 2006
  • Background : Severe community-acquired pneumonia (CAP) can develop into respiratory failure that requires mechanical ventilation (MV), which is associated with a higher rate of mortality. It was recently reported that a hydrocortisone infusion in severe CAP patients was associated with a significant reduction in the length of the hospital stay and mortality. This study evaluated efficacy of a hydrocortisone infusion for patients with severe CAP requiring MV. Methods : From February 2005 to July 2005, 13 patients (M : F = 10 : 3, mean age: $68.6{\pm}14.1years$), who were diagnosed with severe CAP and required MV, were enrolled in this study. Hydrocortisone was administered as an intravenous 200mg loading bolus, which was followed by an infusion at a rate of 10mg/hour for 7 days. The control group was comprised of patients with severe CAP requiring MV but in whom corticosteroid was not used before study period. The clinical and physiologic parameters on or by day 8 and the outcome in the hydrocortisone infusion group were compared with those in the control group. Results : 1) There was no significant difference in age, gender ratio, SAPS II, SOFA score, temperature, leukocyte count, PaO2/FiO2 (P/F) ratio, the number of patients with P/F ratio < 200, chest radiograph score, lung injury score and catecholamine-dependent septic shock between the hydrocortisone infusion group and control group at day 1. 2) At day 8, the proportion of patients with an improvement in the P/F ratio ${\geq}100$ and the chest radiograph score was significantly higher in the hydrocortisone infusion group than in the control group (61.5% vs. 15.4%, 76.9% vs. 23.1%, p< 0.05). However, there was no significant difference in the other clinical and physiologic parameters. 3). There was no significant difference in the duration of the MV, ICU stay, hospital stay and 10th and 30th day mortality between the two groups. Conclusion : Hydrocortisone infusion for patients with severe CAP requiring invasive mechanical ventilation may be effective in improving the level of oxygenation and the chest radiograph score.

Usefulness of a Alvarado Scoring System for the Diagnosis of Acute Appendicitis in Children (소아 충수돌기염 진단에서 Alvarado Scoring System의 유용성)

  • Yang, Eun Seok;Yoon, Sung Kwan;Kim, Eun Young;Rho, Young Il;Park, Sang Kee;Park, Yeong Bong;Mun, Gyeong-Rae
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • Purpose: Alvarado scoring system was evaluated regarding its usefulness for the early diagnosis of acute appendicitis in adult and in reduction of the incidence of negative appendicectomies. To evaluate the accuracy of diagnosing appendicitis using the Alvarado score in children. Methods: Prospectively, we surveyed 122 patients (male 67, female 55) suffering from abdominal pain, who had visited to the emergency department of Chosun University Hospital from June 2002 to May 2003. The Alvarado score has been computed from the white blood cell count, neutrophil count, body temperature, resistance in the right lower quadrant, length of symptoms, nausea and vomiting. Each patient was evaluated by a pediatric resident and then by a general surgeon independently. Results: Out of 170 total children who visited to the emergency department due to abdominal pain, 122 patients were associated with appendicitis. A total of 122 patients (67 male and 55 female) were visited to the emergency room with suspected appendicitis. From 105 operated patients, 92 (87.6%) were diagnosed acute appendicitis and erronous diagnostic rate was 12.4%, pathologically. Mean alvarado score of appendicitis group was $5.40{\pm}1.24$ whereas those of non-appendicitis group was $3.73{\pm}1.82$ (p<0.05). From 6 Alvarado score high sensitivity (86.4%) and high specificity (80.0%) were observed. Sensitivity of ultrasonography or computed tomography was 92.5%. Conclusion: We found that Alvarado score system is a noninvasive, safe diagnostic method, which is simple, reliable and repeatable. Alvarado score is useful system for a first, rapid and economic evaluation for the appendicitis in children.

  • PDF

Studies on the Cold Attenuation and Protective Effects of a Thermostable Newscastle Disease Virus Isolated from Korean Pheasants (한국산 꿩으로부터 분리한 열안정성 뉴캣슬병 바이러스의 저온순화와 방어효과)

  • K. H. Kwak;S. C. Han;T. J. Kim;K. S. Chang;M. H. Jun;H. J. Song
    • Korean Journal of Poultry Science
    • /
    • v.28 no.2
    • /
    • pp.83-89
    • /
    • 2001
  • Newcastle disease virus, CBP-1 strain isolated from Korean pheasants was passaged for 173 times by 9-day-old specific pathogenic free (SPF) embryonated eggs at $37^{\circ}C$ (parent strain) and subsequently passaged for 15 (cold attenuation (CA) -15) and 30(cold attenuation (CA) -30) times by 10-day-old of commercial broiler chicks embryonated eggs at $29^{\circ}C$, respectively, The Physical and chemical properties (sensitivity to lipid solvents, low pH and thermostability), pathogenicity (mean death time, intracerebral pathogenic index and intravenous patho-genic index), safety, booster or protective effect and characterization of temperature sensitivity were measured in cold attenuated CA-15 or 30 strain and compared to those of parent CBP-1 strain. NDV, CBP-1 CA-30 strain acquired cold attenuation and decreased infectivity at $41^{\circ}C$ compared to those of parent strain grown at $37^{\circ}C$. It lost hemagglutination activity (HA) and cell infectivity at $56^{\circ}C$ for 30, 60, and 120 Min. CA-30 strain treated with ethyl ether also lost its HA and cell infectivity. Both CA-30 and parent strains exhibited a little resistant to HA at pH 3.0 glycine HCI buffer. Intracerebral pathogenic index (ICPI) and intravenous pathogenic index (IVPI) of parent strain were 1.12 and 1.45, but decreased to 0.75 and 0.00 in CA-30 strain, respectively. The safety was evaluated by mortality in chicks inoculated with 10$^{4.0}$ EID$_{50}$ /0.1 ml. The mortalities of parent, CA-30 and commercial Bl strains were 17.5, 12.0 and 0.0%, respectively. The safety of CA-30 strain was higher than that of parent strain. The booster effects of CA-30 strain and parent strain performed in 4-week-old chicks after being vaccinated with primary commercial Bl strain.

  • PDF

Effect of Ventilating System on the Performance of Broiler Chicks in an Environmental Controlled Cage House (무창계사의 환기 시스템이 케이지 사육 육계의 초기 생산성에 미치는 영향)

  • HwangBo J.;Hong E.C.;Lee B.S.;Bae H.D.;Lee S.J.;Cho S.B.;Kim H.K.;Kim J.H.;Park B.S.;Song J.I.
    • Korean Journal of Poultry Science
    • /
    • v.33 no.1
    • /
    • pp.57-63
    • /
    • 2006
  • This study was conducted to investigate the effect of ventilating system of environmental controlled broiler house on broiler production. Three hundred eighty four broiler chicks (Hubbard, mean live weight of $44.5{\pm}2.0g/bird$) were reared for 2 wk. The results of the present study were summarized as follows : 1. Ammonia gas production was lower in the second and the third floors of cages compared with first floor of cages 13.5 and 13.5 vs 14.6 ppm, respectively). The observations of ammonia production in the morning and afternoon were similar. The production of carbon dioxide was not different between morning and afternoon, but it was tended to decrease in the forth floor of cages due to a fresh air 2. A wind velocity in the enclosed house was similar across lower, middle and upper section (0.57m/sec, 0.22m/sec and 0.04msec, respectively). In order to maintain an optimal air flow velocity in the cages, the duct entrance was punched, and then the air flow was full-round in the overall space in the cage. 3. Daily liveweight gain, feed intakes, and feed efficiency were not significant differences among treatments during whole experimental period (P>0.05). Therefore, the present results showed that temperature, moisture and atmosphere controlling were desirable, and air flew evenly in the cage.

Sick Building Syndrome in 130 Underground Workers (지하상가 근무자의 건강 장애에 관한 실태조사)

  • Joo, Ree;SaKong, Joon;Chung, Jong-Hak;Park, Sang-Whan;Kim, Dong-Hee;Kim, Dong-Min;Choi, Eun-Kyong;Cho, Hyun-Geon
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.2
    • /
    • pp.325-340
    • /
    • 1998
  • A cross-sectional study was conducted to evaluate the relationship between sick building syndrome(SBS) and the environmental factors affecting SBS on 130 underground workers and 60 controls. The study consisted of 1) a review of environmental condition 2) measurement of temperature, $O_2$, $CO_2$, CO, and formaldehyde and 3) a questionnaire survey of symptom prevalence and perception of environmental conditions using indoor Air Quality questionnaire recommended by National Institute for Occupational Safety and Health. Bronchitis and dust allergy were more prevalent in underground workers significantly(p < 0.05). Among the 18 symptoms related to the indoor air pollution, the experience rate of dry, itching or irritated eyes, sore or dry throat, chest tightness, tired or strained eyes and dry or itchy skin symptom was significantly different between the underground workers and controls. The diagnostic criteria of SBS was defined as at least 1 symptom is experienced 1-3 times a week during the last 1 month among 18 indoor air pollution related symptoms which can be relieved by moving out of the underground. Applying the criteria, the mean symptom score was significant higher in underground workers than controls significantly (p < 0.05). These resalts indicated that underground workers are under inappropriate ergonomic and physical condition and inadequate ventilation. Their experience rate of symptoms related to indoor air pollution and prevalence of SBS was significantly higher than controls. To reduce the prevalence of SBS of underground workers, the surveillance system of indoor air quality, restriction of using fuel in underground and legislative regulations for the environment are needed to establish a better indoor air quality. Early detection, treatment and prevention of SBS through medical attention is also needed.

  • PDF

Effect of Silicon Source and Application Method on Growth of Kalanchoe 'Peperu' (규산염 종류와 적용방법이 칼랑코에 '페페루'의 생육에 미치는 영향)

  • Son, Moon-Sook;Oh, Hye-Jin;Song, Ju-Yeon;Lim, Mi-Young;Sivanesan, Iyyakkannu;Jeong, Byoung-Ryong
    • Horticultural Science & Technology
    • /
    • v.30 no.3
    • /
    • pp.250-255
    • /
    • 2012
  • The effect of different source silicon ($CaSiO_3$, $K_2SiO_3$, and $NaSiO_3$) and their application methods (foliar application and subirrigation) on the growth of potted kalanchoe was investigated. Rooted terminal cuttings of Kalanchoe blossfeldiana 'Peperu' were transplanted into 10.5 cm plastic pots containing a commercial growing medium. Then, a nutrient solution, containing 0 or $50mg{\cdot}L^{-1}$ Si as $K_2SiO_3$, $Na_2SiO_3$, or $CaSiO_3$ and adjusted to EC 1.4-$1.6mS{\cdot}cm^{-1}$ and pH 6.0, was supplied through subirrigation along with the nutrient solution or by a foliar application. Plants were grown in a glasshouse under a mean temperature of $23^{\circ}C$ and RH of 70-80%. After 12 weeks of cultivation, plant growth characteristics and leaf tissue contents of P, K, Ca, Mg, Na, S, and Si were measured. Both subirrigational supply and foliar application of Si decreased the plant height and flower stem length. However, the plant condition in the foliar application resulted in disease-like soft rot on the leaf. Among three silicon sources tested, $CaSiO_3$ supplied through a subirrigation system increased shoot tissue contents of Si and chlorophyll as compared to the $Na_2SiO_3$ or $K_2SiO_3$ treatment. Shoot tissue contents of Ca, K, and Na increased when the plant was supplied with $CaSiO_3$, $K_2SiO_3$, and $Na_2SiO_3$, respectively. Subirrigational supply of $K_2SiO_3$ and $NaSiO_3$ decreased the shoot tissue contents of Ca and Mg, and K and Ca, respectively. Therefore, $CaSiO_3$ supplied through a subirrigation system could improve plant quality of kalanchoe 'Peperu' making compact potted plants.

Effect of Nutrient Solution Strength on Growth, Fruit Quality and Yield of Strawberry 'Mehyang' in Hydroponics (배양액의 농도가 딸기 '매향' 생육, 과실의 품질 및 수량에 미치는 영향)

  • Jun, Ha Joon;Byun, Mi Soon;Liu, Shi Sheng;Jeon, Eui Hwan;Lee, Yong Beom
    • Horticultural Science & Technology
    • /
    • v.31 no.2
    • /
    • pp.173-178
    • /
    • 2013
  • Experiments were conducted to investigate the optimum concentration of nutrient solution for strawberry 'Maehyang' bred domestically for exportation in hydroponics. Nutrient solutions for strawberry, which was made by Yamazaki, were supplied electrical conductivity (EC) 0.6, 0.8, 1.2, and $1.8dS{\cdot}m^{-1}$ after planting on cocopeat medium during the experiment period. Growth of shoot of strawberries did not show any statistical differences among treatments. Fruit length showed the longest in EC 0.8 and $1.2dS{\cdot}m^{-1}$, followed by 0.6 and $1.8dS{\cdot}m^{-1}$ in the first and third cluster. It showed the shortest in EC $1.8dS{\cdot}m^{-1}$ in the second cluster but there were no significant differences among treatments in the fourth cluster. Fruit diameter did not show significant differences among treatments in the first and second cluster but was the longest in the lowest concentration EC $0.6dS{\cdot}m^{-1}$ in the third cluster. The shortest was in EC $1.8dS{\cdot}m^{-1}$ in the fourth cluster. The heaviest mean fruit weight appeared in EC 0.8 and $1.2dS{\cdot}m^{-1}$, and the lightest was in EC $1.8dS{\cdot}m^{-1}$ in the first cluster and also lightest in EC $1.8dS{\cdot}m^{-1}$ but no significant differences was found among other treatments in the second & third cluster. Also the fruit weight was significantly light in plants grown in EC $1.8dS{\cdot}m^{-1}$ than $0.6dS{\cdot}m^{-1}$ in the fourth cluster. Soluble solids content of fruit was the highest in EC $0.6dS{\cdot}m^{-1}$ in all cluster. As a result, we came to the conclusion that the optimum EC for strawberry 'Maehyang' was EC 0.8 - $1.2dS{\cdot}m^{-1}$ during low temperature season. This result will be utilized as an indicator for strawberry hydroponics.

Seagrass (Zostera marina L., Zosteraceae) Bed in the Brackish Lake Hwajinpo, Korea (화진포 기수호에 해산식물 거머리말 (Zostera marina L., Zosteraceae))

  • Lee, Sang-Yong;Kwon, Chun-Joong;Heo, Sung;Choi, Chung-Il
    • Korean Journal of Ecology and Environment
    • /
    • v.33 no.4 s.92
    • /
    • pp.336-341
    • /
    • 2000
  • This study was conducted to clarify the habitat characteristics and distribution of seagrass. Zostera marina L. (Zosteraceae) in the brackish Hwajinpo Lake, Korea in June 1998 and July 2000. Z. marina beds were distributed along the sea-side cost of the lower lake mouth at 0.8 to 1.5m in death, and the seagrass bed area was about 3,200 m$^{2}$. Salinity, water temperature and pH were in the range of 8.0${\sim}$23.0$%_{o}$, 22.0${\sim}$23.7$^{\circ}C$ and 8.34${\sim}$8.62, respectively. Nutrient concentrations were generally now (TN: 24.34 ${\mu}$M, NH$_{4}$-N: 2.57 ${\mu}$M, NO$_{3}$-N: 0.56 ${\mu}$M, NO$_{2}$-N: 0.27 ${\mu}$M, TP: 2.08 ${\mu}$M, PO$_{4}$-P: 0.34 ${\mu}$M). Suspended particulate matters (SPM) concentration averaged 62.8 mg/l and particulate organic matter (POM) averaged 21.3 mg/l. Organic content of SPM averaged 33.9%. The beds substratum was composed of well-sorted, fine sand and its mean brain size was 3.13${\Phi}$. The Z. marina vegetation was almost submerged, and the morphological characteristics can be classified as steno-leaf phenotype by the shoot length, leaf width, and number of leaf vein. Shoot length and leaf width were 70.0${\sim}$126.5 cm and 5${\sim}$7 mm, respectively. Shoot densities ranged from 264 to 296/m$^{2}$, and the plants biomass was estimated at 332.6 to 373.0 g dw/m$^{2}$. Therefore, the habitats of Z. marina in Korea were recognized in a brackish lake, and morphological characteristics appeared to be variable.

  • PDF