• 제목/요약/키워드: Mean skin temperature

검색결과 237건 처리시간 0.033초

체형별 발한 반응에 관한 연구 (A Study of Sweating Reaction by the Somato Types)

  • 심부자
    • 대한인간공학회지
    • /
    • 제17권2호
    • /
    • pp.65-82
    • /
    • 1998
  • To investigate the difference of sweating reaction by the somato types, we measured total sweat rate, local sweat rate, skin temperature, physiological reaction and psychological reaction at $25{\pm}1^{\circ}C$ and $29{\pm}1^{\circ}C$ under laboratory conditons. Nine healthy adult females were divided into three somato types : slender (3), normal (3) and obese (3). The results were as follows ; Total sweat rate was highest in the obese type, followed by the normal and slender types in order. Local sweat rate was highest in the infrascapular area, and then came breast, the back of the hand, upper ann, anterior leg, and anterior thigh in all somato types. Mean skin temperature was highest in the slender type, and followed the normal and obese types. Rectal temperature, blood pressure and pulse rate were highest in the obese type. Psychological reaction appeared 'hot', 'humid', 'sweaty' as ambient temperature went up. Somato types made little difference in psychological reaction.

  • PDF

자돈의 일중 체온변화에 관한 연구 (Changes in Body Temperature of Piglets in a Day)

  • 이원현;정왕용;이상철;이상락
    • 한국축산시설환경학회지
    • /
    • 제18권2호
    • /
    • pp.91-94
    • /
    • 2012
  • 본 실험에서는 자돈을 대상으로 비정상 체온의 판정을 위한 알고리즘 개발에 활용할 정상상황에서의 표피 (귀, 목, 머리) 및 심부 체온의 database를 구축하였다. 평균체중 46kg의 자돈 5두를 공시하여 $22.5{\pm}2.0^{\circ}C$로 설정된 이유 자돈사에 설치한 개별 케이지에 2주간 적응시킨 후, 귀, 목 및 머리의 피부온도와 심부 (피하지방) 체온, 그리고 돈사내 온도를 1 mm k-type 열전대와 National Instruments Corporation (Austin, Texas, USA)의 장치 (cDAQ-9174, NI-9214, 9214TB)를 이용하여 1분 간격으로 17일간 연속하여 측정하였다. 수집된 체온 data는 24시간 단위로 통합하여 매 시간대별 평균 및 표준편차를 산출했다. 모든 측정 site의 하루 중 체온의 변화는 오전 6시에 가장 낮은 값으로 나타났으며 이후 점점 증가하다가 14시에 가장 높은 값을 보였고 그 후 익일 오전 6시까지 서서히 떨어졌다. 이런 변화 pattern은 외부온도의 변화와 일치하였다. 심부의 체온은 $35{\sim}39^{\circ}C$의 범위로 변화가 적은 반면에 목과 머리는 각각 $32{\sim}36^{\circ}C$, $30{\sim}36^{\circ}C$이고, 귀는 $29{\sim}36^{\circ}C$로 변화 폭이 컸다. 귀의 경우 가장 낮은 값은 자돈의 활동이 가장 적은 새벽시간이었으며, 새벽시간대를 제외한다면 귀, 목, 머리의 체온은 대체적으로 같은 범위의 온도 값을, 심부는 체온의 가장 근접한 값을 나타내고 있다. 이 연구를 통해 축적된 자돈의 표피 (귀, 목, 머리)와 심부 체온의 databse는 RFID (radio frequency identification device)를 이용한 동물의 비정상 체온의 전자적 감지를 위한 알고리즘 개발에 활용 할 수 있을 것으로 사료된다.

냉적용 방법에 따른 심부 및 피부온도변화 (Differences in Body Temperatures according to Three Methods of cold Application)

  • 임난영;김진경
    • 대한간호학회지
    • /
    • 제23권2호
    • /
    • pp.157-169
    • /
    • 1993
  • The most effective modality for cold application and the length of the application have not been determined despite many studies about the use of cold. A quasi-experimental study was conducted to examine the most effective modality among three methods of cold application, the most effective length of time for the application and the continuing effect after each type of cold application. Thirty adult patients admitted to medical and neurosurgical unit and with high fever (above 38.2 ℃) were assigned randomly to each of three cold ap-plication methods : (a) ice bag: (b) cold compress; and (c) tepid water sponge bath. Each method was applied to the whole anterior surface except the face and neck with the patient in the supine pos-ition. Rectal temperatures and skin temperatures (mid chest, upper arm, thigh and leg) were measured be-fore each application and every 10 minutes during ,each application for a period of 60 minutes. They were also measured every 10 minutes for 30 minutes after each cold application was finished. The experiments were carried out from Dec. 22. 1992 through Feb. 26, 1993. The data were analysed using means, ANCOVA Sheffe test and Pearson's Correlation Coefficient. The results of this study are as follows : 1. There were no significant differences among the three cold application methods in the reduction of body temperature, 2. Among the ice bag, cold compress and tepid water sponge bath groups, the ice bag proved to be the most effective method for lowering skin temperature while the cold compress was least effective. 3. Both rectal and skin temperature continued to decrease during the 60 minutes of cold application, but the hunting phenomena was not observed at any of the cold application sites. 4. There were no significant correlations between mean rectal and skin temperatures. 5. Skin temperatures according to the cold application sites decreased to a range of 3.46℃ to 5.20℃ (mid chest), a range of 4.48℃ 4.96℃ (upper arm), a range of 3.86℃ to 5.05℃ (thigh), and a range of 5.42℃ -7.12℃ (leg ). 6. In continuing effect after the cold applications were finished, rectal temperatures according to ice bag, cold compress and tepid sponge bath decreased to 0.29℃, 0.23℃ and 0.09℃ respectively, while the mean skin temperatures increased to 2.39℃ , 2.04℃ and 2.22℃ respectively. In this experiment the ice bag was the most effective modality for lowering skin temperature. when-ever cold is applied for systemic effect, the continuing effect of cold should be considered. The determination of the most effective length of time for cold application needs further study.

  • PDF

여름철 작업자들의 고체온증 예방을 위한 액체냉각복 개발 및 효과적인 냉각온도와 인체 냉각부위 탐색 (Developing Liquid Cooling Garments to Alleviate Heat Strain of Workers in Summer and Exploring Effective Cooling Temperature and Body Regions)

  • 정재연;강주호;설선홍;이주영
    • 한국의류산업학회지
    • /
    • 제22권2호
    • /
    • pp.250-260
    • /
    • 2020
  • The purpose of the present study was to explore the most effective body region and cooling temperature to alleviate heat strain of workers in hot environments. We developed liquid cooling hood, vest, sleeves and socks and applied the water temperatures of 10, 15, 20, and 25℃ through the liquid cooling garments in a hot and humid environment (33℃ air temperature and 70% RH air humidity). A healthy young male participated in a total of 16 experimental trials (four cooling garments × four cooling temperatures) with the following protocol: 10-min rest, 40-min exercise on a treadmill and 10-min recovery. The results showed that rectal temperature, mean skin temperature, and ratings of perceived exertion during exercise; heart rate and diastolic blood pressure during recovery; and total sweat rate were lower for the vest condition than other garment conditions(p < .05). However, there was no differences in mean skin temperature among the four cooling garments when we compared the values converted by covering area(%BSA). When we classified the results by cooling temperature, there were no consistent differences in thermoregulatory and cardiovascular responses among the four temperatures, but 25℃ water temperature was evaluated as being the most ineffective cooling temperature in terms of subjective responses. In conclusion, the results indicated that wearing cooling vest with < 20℃ cooling temperature can alleviate heat strain of workers in hot and humid environments. If the peripheral body regions are cooled with liquid cooling garments, larger cooling area with lower cooling temperature than 10℃ would be effective to reduce heat strain of workers. Further studies with a vaild number of subjects are required.

수면시 침상기후와 인체생리반응에 관한 연구 -온돌환경을 중심으로- (A Study on the Bed Climate and the Physiological Responses in Sleep. - On Ondol Environment -)

  • 김명주;최종화
    • 한국의류학회지
    • /
    • 제15권2호
    • /
    • pp.77-87
    • /
    • 1991
  • The purpose of this study were to investigate the bed climate and the physiological responses in sleep on the traditional Korean floor heating system called Ondol. Ondol has been the most widely used heating system in Korea, yet there has been a no systematic studies examined its environmental effects on human body. Experimental room was constructed to match the typical thermal environment of Ondol. (floor surface temperature; $32\~33^{\circ}C$, air temperature; $22.5{\pm}1.0^{\circ}C$, relative humidity; $64.0{\pm}4.0\%$RH, air velocity; 0.25 m/sec.) Three different combinations of bedclothes were chosen for the experiment based on the study results showing that they were the most widely used types in Korea. Type 1 was the combination of a cotton-padded mattress with a cotton-padded Korean style blanket. Type 2 was a cotton-padded mattress with a cotton-guilted Korean style blanket. Type 3 was a cotton-padded matless with a polyacryl blanket. Thermal resistance of each of these combina-tions in the bedclothes was measured using thermal manikin. Two adult female was chosen for the seven hour sleeping experiment which was known to be the average sleeping hours of Korean adult female. The bed climate was measured with the temperature under the mattress, the surface temper-ature of the mattress, and the air temperature and the relative humidity of the space between the mattress and blanket. The skin temperature, rectal temperature of the subjects and the bed climate were measured eight times, one hour before the experiment and every hour during the experiment. The weight loss and the subjective sensation were measured for the each subjects before and after the experiment. The procedure was repeated twice with two subjects and three types of bedclothes, yielding twelve combinations of results. The results were as follows; 1. With the surface temperature of $32\~33^{\circ}C$ of Ondol, air temperature was $22.5{\pm}1.0^{\circ}C$ with $64.0{\pm}4.0\%$ RH. The bed climates were $39.2{\pm}40.8^{\circ}C$ under the mattress, $35.3\~36.2^{\circ}C$ on the mattress, and $26.9\~32.0^{\circ}C$ with $56.0\~71.3\%$ RH between the mattress and the blanket. 2. Mean skim temperature during sleep was 34.2"C with local skin temperature of $34.0\~35.5^{\circ}C$. The skin temperatures of abdomen, thigh, foot were higher than the other parts of the body. 3. The skin temperature of chest, thigh, leg and back varied significantly according to the combinations of bedclothes. With the cotton-padded blanket, the skin temperature was the highest, while with the cotton-guilted blanket showed lowest. 4. Examining the relationship between the mean skin temperature and the local skin temper-ature, the chest temperature showed the highest correlation with the former. Therefore, the chest temperature can be recommended to represent the skin temperature in measuring the bed climate. 5. The subjective bed climates were $39.0\~40.4^{\circ}C$ under the mattress, $35.2\~35.9^{\circ}C$ on the mattress, $29.8\~31.6^{\circ}C$ with $56.8\~68.4\%$ RH between the mattress and blanket. In sum, from this experiment we not only obtained the reliable value of bed climates on Ondol, but also showed that the bed climates and the physiological responses were affected differently according to the materials of bed clothes.

  • PDF

방진복 착용에 따른 인체의 온열생리적 특성 및 주관적 감각 (The Physiological Responses and Subjective Sensation in the Subjects Wearing Dust-free Garment for Semiconductor Industrial Environments)

  • 권오경;이창미
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1998년도 춘계학술발표 논문집
    • /
    • pp.255-263
    • /
    • 1998
  • Dust-free garment prevents contamination which otherwise is caused by skin and clothes to protect from dust or dirt. Therefore, it requires high performance and should function as a working clothes. Clothes are a medium between human and thermal environmental system, and it is required to study human enviroment to ensure comfortableness of clothes and to satisfactorily go along with enviroment .This study investigates the physical and physiological features of dust-free garment used in the clean room at a semiconductor factory in oredr to scientifically clarify what the dust-free garmint is as well as to contribute to the design and development of high performance material and clothes. Three kinds of dust-free fabrics (DFG-I, DFG-II, DFG-III) which are being developed by a local company are used to manufacture dust-free garment. These dust-free garments are dressed and tested in such an enviroment as similar to semiconmemts with temperature at 23${\pm}$1$^{\circ}C$ and humidity at 50${\pm}$5%RH in order to investigate the thermo physiological and psychological features of human body. The results of this study are as follows. The results of this study are as follows. 1.The mean skin temperature was significantly different among the clothes, subjects and experimental time. Temperature tends to rise from the time of exercising load. Continuous motion coupled sealed clothes prevents heat transmittance, and temperature rises in the order of DFG-l, DFG-ll and DFG-lll as time course. 2.As for the skin temperature by local timperature is minimun on the head and torso and increares remarkably at the terminal part of human body. 3. As for the body mass loss was significantly higher in DFG-lll than DFG-l and DFG-ll. 4. Though there is no significant difference in the temperature within clothes among the kind of clothes temperature is 1$^{\circ}C$ higher in the back. Temperature within all the dust-free garments 29.7$^{\circ}C$ in the back and 31.3$^{\circ}C$ in the chest which belong to the comfort zone(31-33$^{\circ}C$). The relative humidity is 39.7%RH in the chest and 33.8%RH in the back which is slightly below the comfort zone(40-60%RH) 5. The thermal sensation belong to the comfort zone regardless of the kinds of clothes. The subjects feels a slight fatigue as times goes. As for the subjective sense of subjects the mean skin temperature as well as temperature and humidity within clothes show similar tendency. This means that they relate with each other.

  • PDF

한냉에 노출된 인체의 냉각과 총지방량 및 S/V 비율 사이의 관계 (Relationship between Total Body Fat and S/V Ratio and Body Cooling for Two Hours at $15^{\circ}C$)

  • 정관옥;남기용
    • The Korean Journal of Physiology
    • /
    • 제3권1호
    • /
    • pp.19-28
    • /
    • 1969
  • Skin temperatures on 10 sites and rectal temperature at every 10 minutes, oxygen consumption at every 20 minutes were measured on 18 male subjects (ages between 14 and 47 years) after exposure to cold air at $15^{\circ}C$ for two hours in a climatic room. Total body fat measured by means of a skinfold method and ratio of body surface area (S) to body volume (V), S/V, were utilized as basis of observations. Surface area was calculated after DuBois equation and body volume was calculated by our original formula. In influencing on the heat loss from the body core to the cold environment, % fat showed inverse relations, whereas, S/V ratio showed direct relations. Thus these two factors acted antagonistically on the body heat loss. Local skin temperatures showed negative correlations with skinfold thickness on the same site, nemaly, on chest, r=-.567; on back, r=-.507; and on upper arm, r=-.353. The other 7 skin sites showed low correlations with % fat. Minimum mean weighted skin temperature (MWST) showed a negative correlation (r=-.443) with % fat, and showed no correlation with S/V ratio. Oxygen consumption in the cold air at $15^{\circ}C$ increased from the first measurement at 20 minutes after exposure and maintained the same increasing trend up to 120 minutes. ${\Delta}T_R$ was greater in tile lean subjects who showed a greater % change in oxygen consumption. The antagonistic actions of % fat and S/V ratio on the heat loss were manifested by observations as follows: minimum rectal temperature was higher In fat subjects (r=.600) and lower in subjects with a greater S/V ratio (=-.582), ${\Delta}T_R$ was smaller in fat subjects (r=-.738) and greater in subjects with a greater S/V ratio (r=.618). Temperature difference between body core and skin surface (minimum rectal temperature minus minimum MWST) showed a positive correlation with % fat (r=.600) and a negative correlation with S/V ratio (r=-.881). Decrease in the mean body temperature and heat debt, respectively, showed negative correlations with % fat and positive correlations with S/V ratio.

  • PDF

생활한복형 하절교복의 의복기후와 주관적 감각 (The Clothing Microclimates and Subjective Sensation for Casual Hanbok as School Summer Uniform)

  • 유정자;권수애
    • 한국생활과학회지
    • /
    • 제21권4호
    • /
    • pp.765-780
    • /
    • 2012
  • This study was investigated the clothing microclimate, subjective sensation for the improvement of traditional koran high school student uniform so called "Saenghwal Hanbok". For the purpose, casual hanbok school summer uniforms were made. They were made of 4 different textiles materials - P/R, P100, P/C, P/R/S for blouses, P/W, P100, P/R, P/W/F for skirts. Then their clothing microclimate, subjective sensation were tested at room temperature $25{\pm}1^{\circ}C$ and $50{\pm}10%$ R.H. Clothing Microclimates wearing on the blouses were good matched comfort temperature range. Subjective sensations wearing on the blouses were better than those of traditional koran clothes so called "Hanbok" and quite same for western style clothes. Thermal sensations were indicated some hot condition, and moisture sensations were indicated some wet condition but tactile sensations and comfortable sensations were agreeable. The temperatures of the forehead and the breast wearing on the skirts were indicated the same results with the cases of the blouses. Leg temperatures were some lower than the mean skin temperature, the other parts' temperatures were slightly higher than blouses but the mean skin temperatures were satisfied comfortable ranges. Subjective sensations wearing on the skirts were better than those of the other traditional clothes and even Western clothes. Thermal sensations and moisture sensations were resulted the same with the case of blouses. Currently, P/R material and P/W material seemed to be cool and respectively suitable for blouses and skirts in summer among the materials of modernized Korean traditional costumes and school uniforms, since those materials lowered skin temperature. But better, physiologically pleasant materials for summer clothes should be development in consideration of clothing microclimate and subjective sensation.

축구복 소재와 디자인이 인체생리반응과 주관적 감각에 미치는 영향 (Physiological Responses and Subjective Sensations of Human Wearing Soccer Wear of Different Materials and Designs)

  • 최정화;김소영;전태원
    • 한국의류학회지
    • /
    • 제29권1호
    • /
    • pp.35-45
    • /
    • 2005
  • The purpose of this study was to evaluate thermal properties of soccer wear with different materials and designs. As a beginning step, the questionnaire survey about the actual condition of soccer wears was conducted. with the results of the questinnaire, two soccer wears with new material and design that were improved in tactile sensations, absorption and ventilation were developed. We evaluated thermal and subjective responses of subjects wearing Korea national soccer team uniform in 1998 World Cup (Uniform 98), soccer wear with new material and same design(New II) and with new material and new design(New I). New I was made with mesh in armhole for improving ventilation. Rectal temperature, skin temperature, clothing microclimate, and heart rate were measured in climatic chamber test(twelve times) and field test(eighteen times). The results were as follows. 1. As the results of the climatic chamber test, rectal temperature was lower in New I and New II than Uniform98, and mean skin temperature was lower in New I than Uniform 98 and New II. Heart rate was lower in New I than New II, and total body weight loss and local sweating were not significantly different by soccer wears. 2. As the results of the field test, rectal temperature was lower in New I than Uniform98 and New II. Mean skin temperature was lower in New II than Uniform98 and New I. Clothing microclimate temperature was lower in New II than Uniform98 and New 1, and clothing microclimate humidity was lower in New I, New II than Uniform 98. Heart rate was lower in New I than Uniform 98, New II and total body weight loss and local sweating were lower in New I, New II than Uniform 98. In conclusion, New I using new design using mesh in armhole and new material using sweat absorbent finishing was excellent from the point of view of physical responses, ventilation and sweat absorption.

체성분 구성에 따른 대학생의 여름철 실내 쾌적온도 (Preferred Indoor Temperature of College Students in Summer by Body Composition)

  • 심현섭;정운선
    • 한국지역사회생활과학회지
    • /
    • 제22권1호
    • /
    • pp.155-161
    • /
    • 2011
  • This study was designed to present the preferred indoor temperature of college students in summer based on their body composition. A total of 19 subjects, 10 females and 9 males, participated in this study. They sat in a climatic chamber controlled at $27^{\circ}C$ wearing a short sleeved shirt and short trousers. The air temperature decreased by $0.5^{\circ}C$ every 10 minutes until it reached $24^{\circ}C$. Oxygen uptake, rectal temperature, and skin temperature, subjective sensation were measured and recorded. Females increased the rectal temperature and decreased mean skin temperature in an air conditioned environment, showing better physiological responses. But they felt more thermal discomfort than males. The preferred indoor temperature of college students in summer was $25.3^{\circ}C$, $25.7^{\circ}C$ for females and $24.97^{\circ}C$ for males.