• 제목/요약/키워드: Mean Value Function

검색결과 598건 처리시간 0.026초

Environmental effects in the stellar populations of Compact Elliptical galaxies

  • Kim, Suk;Jeong, Hyunjin;Lee, Youngdae;Joo, Seok-Joo;Lee, Jaehyun;Sung, Eon-Chang
    • 천문학회보
    • /
    • 제42권1호
    • /
    • pp.30.2-31
    • /
    • 2017
  • Compact elliptical (cE) galaxies are in a rare class of stellar systems characterized by high stellar densities, small sizes, high velocity dispersion, and high metallicity corresponding to elliptical galaxies. cE galaxies have been observed around massive galaxies, so they could be formed under strong influences of tidal stripping and truncation. However, the recent discovery of isolated cE galaxies requires the need of new formation scenarios. We aim at finding cE galaxies in various environments using SDSS DR12, and studying stellar population of cEs as function of environments. Based on the typical properties of cE galaxies, we selected cE candidates by restricting that low-luminosity Mg > 19.5 mag, small sizes Re < 700 pc, and high velocity dispersions ${\sigma}$ > $60kms^{-1}$. Since effect radii of cE candidates are mostly smaller than the seeing size of SDSS photometry, we calculated the effective radius by fitting a Sersic profile. In addition, we assumed that host galaxies have brightness with Mr < -21 mag, and an environmental parameter is computed as distances between cE galaxies and host-galaxies. We found 112 cE galaxies at z < 0.05, which have high sersic indices (mean value is 5.2) similar to the typical massive elliptical galaxies. Mgb values of cE galaxies increase as the distances from the host galaxies decrease. Especially, for cEs close to the host galaxies (NcE; $D_{host}$ < 300 pc), the Mgb values are similar to those of massive elliptical galaxies, which is consistent with the previous studies. On the other hand, cE galaxies distant from the host galaxies (DcE; Dhost >300 pc) have lower Mgb values than the conventional cE. The Mgb values follow the ${\sigma}$-Mgb relation of elliptical galaxies, and are connected to its faint end. This can be explained as a result of different merger histories for differing environments. For example, NcE galaxies are formed by tidal stripping by massive galaxies as suggested by previous studies, but DcE galaxies could be linked with high-redshift spheroids (e.g. red nuggets) which have not evolved into present-day elliptical galaxies because of the environmental influences.

  • PDF

소아환자의 세보플루란 흡입진정시 미다졸람 병용 투여의 효과에 관한 예비연구 (Effects of Midazolam with Sevoflurane Insufflation Sedation on Concomitant Administration in Pediatric Patients : A Preliminary Study)

  • 지성인;김종수
    • 대한소아치과학회지
    • /
    • 제41권4호
    • /
    • pp.283-291
    • /
    • 2014
  • 심한 치과적 공포와 불안으로 치과적 행동조절에 문제를 일으키는 환자의 경우, 진정법과 같은 약물적 행동 조절 방법이 요구될 수 있다. 이번 연구에서는 소아 환자에서 세보플루란 흡입진정시에 추가적으로 0.1 mg/kg의 미다졸람을 근육주사하였을 때 진정 깊이와 심폐기능에 미치는 영향을 알아보기 위해 2013년 1월부터 2014년 3월 사이 본원에서 세보플루란 흡입진정 하에 치과치료를 받은 환자의 마취기록지를 후향적으로 분석하였다. 3~6세의 환자를 대상으로 하였으며, 세보플루란 단독 사용군이 18명, 미다졸람 병용 투여군이 18명이었다. 미다졸람 병용 투여군의 평균 엔트로피 값은 세보플루란 단독 사용군에 비해 10정도 낮게 측정되었으나 통계적 유의성은 없었으며(p > 0.05), 분당 심박수와 평균동맥압은 미다졸람 병용 투여군이 세보플루란 단독 사용군에 비해 높은 값을 보였다(p < 0.05). 즉, 0.1 mg/kg의 미다졸람 근육주사는 세보플루란 흡입진정시 진정의 질을 높이는데 큰 도움이 되지는 않았으며, 추후 세보플루란 흡입진정과 병용 사용하기에 적절한 미다졸람의 용량을 결정하기 위한 추가적인 연구가 필요할 것으로 사료된다.

횡보강근이 없는 100 MPa 이하 콘크리트의 철근 압축이음 강도와 이음길이 (Capacity and Length of Compression Lap Splice in Unconfined Concrete of 100MPa and Less Compressive Strength)

  • 천성철;이성호;오보환
    • 콘크리트학회논문집
    • /
    • 제22권5호
    • /
    • pp.659-666
    • /
    • 2010
  • 현행 설계기준식에 따르면 초고강도 콘크리트에서는 철근 인장이음길이보다 압축이음길이가 더 길어지는 현상이 발생된다. 압축이음은 단부 지압이 존재하므로, 인장이음보다 길 필요는 없다. 초고강도 콘크리트의 경제적 실용화를 위해 합리적인 압축이음강도의 평가가 필요하다. 이를 위해 설계강도 80, 100 MPa 콘크리트를 이용하여 횡보강근이 없는 압축이음 실험을 수행하였다. 실험 결과 압축이음강도는 콘크리트 강도의 제곱근에 비례하는 것으로 평가되었다. 지압에 의해 발현되는 이음강도는 이음길이와 무관하며 콘크리트 강도의 제곱근에 비례하는 것으로 평가되었다. 58개 실험체의 평균은 $16.5\;\sqrt{f_{ck}}$이다. 부착에 의해 발현되는 강도를 ACI 408식으로 평가한 결과 [실험값]/[이론값]의 비는 평균 0.94로, 인장이음의 부착강도와 거의 유사하였다. 따라서 인장이음강도에 대비한 압축이음강도의 향상은 단부 지압효과로 설명될 수 있다. 실험결과에서 분석된 이음길이와 콘크리트 강도의 영향 특성을 고려하여 압축이음강도 평가식과 압축이음길이 설계식을 제안하였다. 제안된 설계식은 통계적 기법에 기반을 두어, 이음부가 철근 재료강도와 동일한 수준의 신뢰성을 확보할 수 있다.

Gated Cardiac Blood Pool scan에서의 심장 주위 배후방사능 관심영역 설정시 산란선의 영향을 감소시키기 위한 연구 (Study a Technique for Reducing the Influence of Scattered Rays from Surrounding Organs to the Heart during Gated Cardiac Blood Pool scan)

  • 김정열;박훈희;남궁혁;조석원;김재삼;이창호
    • 핵의학기술
    • /
    • 제12권1호
    • /
    • pp.33-38
    • /
    • 2008
  • Purpose: The Gated cardiac blood pool scan is non-invasive method that a quantitative evaluation of left ventricular function. Also this scan have shown the value of radionuclide ejection fraction measurements during the course of chemotherapy as a predictor of cardiac toxicity. Therefore a reliable method of monitoring its cardiotoxic effects is necessary. the purpose of this study is to minimize the overestimate of left ventricular ejection fraction (LVEF) by modified body position to reduce the influence of scattered rays from surrounding organs of the heart in the background region of interest. Materials and Methods: Gated cardiac blood pool scan using in vivo $^{99m}Tc$-red blood cell (RBC) was carried out in 20 patients (mean $44.8{\pm}8.6$ yr) with chemotherapy for a breast carcinoma. Data acquisition requires about 600 seconds and 24 frames of one heart cycle by the multigated acquisition mode, Synchronization deteriorates toward the end of the cycle and with the distance from the trigger signal (R-wave) by ECG gating. Gated cardiac blood pool scan was studied with conventional method (supine position and the detector head in $30-45^{\circ}$ left anterior oblique position and caudal $10-20^{\circ}$ tilt) and compared with modified method (left lateral flexion position with 360 mL of drinking water). LVEF analysis was performed by using the automatically computer mode. Results: The ROI counts of modified scan method were lower than LV conventional method ($1429{\pm}251$ versus $1853{\pm}243$, <0.01). And LVEF of modified method was also decrease compared with conventional method ($58.3{\pm}5.6%$ versus $65.3{\pm}6.1%$, <0.01). Imaging analysis indicated that stomach was expanded because of water and spleen position was changed to lateral inferior compared with conventional method. Conclusion: This study shows that the modified method in MUGA reduce the influence of scattered rays from surrounding organs. Because after change the body position to left lateral flexion and drinking water, the location of spleen, left lobe of liver and stomach had changed and they could escaped from background ROI. Therefore, modified method could help to minimize the overestimate LVEF (%).

  • PDF

평균 해수면 및 최극조위 자료의 이상자료 및 기준고도 변화(Level Shift) 진단 (Outliers and Level Shift Detection of the Mean-sea Level, Extreme Highest and Lowest Tide Level Data)

  • 이기섭;조홍연
    • 한국해안·해양공학회논문집
    • /
    • 제32권5호
    • /
    • pp.322-330
    • /
    • 2020
  • 부산, 목포 지점의 평균해수면(MSL)과 고극조위, 저극조위 자료의 이상자료 시계열 모델링을 수행하였다. 시계열 모델은 계절성분을 포함하는 SARIMA 모형이며, 일시적인 변화에 해당하는 이상자료(Additive Outlier, AO)와 영구적인 변화를 의미하는 기준고도 변화(Level Shift, LS)를 모델에 포함하였으며, AIC 기준에 의거하여 최적 모델을 선정하였다. 이상자료 모형의 매개변수 추정은 R 프로그램 'tsoutliers' 패키지('tso' 함수)를 이용하였다. 선정 모형을 이용하여 이상자료와 기준고도 변화 진단에 적용한 결과, 부산의 월 단위 고극조위 자료에서 2003, 2012년 발생한 태풍 매미(MAEMI), 산바(SANBA)에 의한 일시적인 수위상승을 65.5, 29.5 cm 정도로 추정하였으며, 목포의 월 단위 평균해수면 자료에서는 1983년의 영산강 하굿둑 건설 사업에 의한 기준고도 변화를 21.2 cm 정도로 추정하였다. 한편 본 연구에서 구성한 모형은 모형의 편향을 유발하는 이상자료의 영향을 포함하며, 모형에 의한 RMS 오차는 연간 자료를 사용한 경우, 부산은 MSL 1.95 cm, 고극조위, 저극조위 각각 5.11 cm, 6.50 cm이며, 목포의 경우에는 큰 조차의 영향으로 MSL 2.01 cm, 고극조위, 저극조위 각각 11.80 cm, 9.14 cm로 부산보다 다소 높게 나타났다.

비만 및 대사성증후군 위험인자에 대한 천연물 식품의 인체 및 동물 효능연구 (Human and Animal Study on the Natural Food for Obesity and Metabolic Syndrome Risk Factors)

  • 문근아;최선미;김선형;김성수;강지연;윤유식
    • 한국식품영양과학회지
    • /
    • 제32권8호
    • /
    • pp.1394-1400
    • /
    • 2003
  • 본 연구에서는 비만 및 대사성증후군 위험 인자를 개선하기 위하여 한방원리를 활용한 조성물 KSH28을 구성하고 동물실험과 인체실험을 통한 효능 평가를 수행하였다. 동물실험에서는 4주령의 수컷 C57BL/6 마우스에게 30%고지방 식이를 급여하면서 4주간 KSH28을 경구 투여하였다. 4주후 체중과 복부의 부고환 및 신장후 지방조직은 KSH28에 의해 용량 의존적으로 의미있게 감소하였다. 또한 지방조직내의 지방세포 평균단면적이 KSH28에 의해 용량 의존적으로 감소하여 지방조직 억제 효과가 뚜렷함이 발견되었다. 공복시 혈당과 혈중 중성지방 농도는 KSH28에 의해 유의적으로 감소하였다. 인체실험에서는 40명 (남성 8명, 여성 32명 )의 피험자들이 KSH28을 포함한 생식 제품(30 g)을 하루 2포 4주간 복용하였다. 체중은 4주간 평균적으로 1.91 kg(남 2.05 kg, 여 1.87 kg)감소하여 주당 약 0.5 kg의 감소를 나타내었고 체성분 분석에서는 체지방이 1.77kg(남 2.69kg,여 1.56kg) 감소하여 체중감량 부분의 대부분을 차지하였다. 수분과 단백질, 근육, 무기질은 변화가 없었다. 여성에서 수축기 혈압, 확장기 혈압과 혈중 총콜레스테롤, LDL콜레스테롤이 모두 의미있게 감소하여 대사성증후군을 개선시킴이 관찰되었다. 간기능의 지표로 이용되는 GPT 수치에는 변화가 없었고 기타의 특별한 부작용은 발견되지 아니하였다.

반복적인 공격적 행동과 혈소판 $^3H$ Imipramine 결합의 상관관계 연구 (REPEATED AGGRESSIVE BEHAVIOR AND PLATELET $^3H$ IMIPRAMINE BINDING)

  • 최진숙;우종인;홍강의
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • 제5권1호
    • /
    • pp.93-101
    • /
    • 1994
  • 반복적으로 공격적인 행동 양상을 보이는 사람들의 세로토닌 반응(serotonergic responsivity)이 정상인과 비교하여 차이가 있을 것인지를 알아보고자 연구를 실시하였다. 나이를 대조하여 공격성군(소년원 재소자 16명)과 대조군(의과대학생 17명)으로 구분한 연구대상에게, 여러 심리검사 척도를 이용하여 공격성의 심한 정도를 정의하고, 두뇌의 세로토닌 기능과 일치하는 것으로 알려진 혈소판의 이미프라민 결합을 측정하여 다음과 같은 결과를 얻었다. 1) 공격성군은 대조군에 비하여 공격척도상 신체적 공격성(physical aggression)의 평균이 모두 유의하게 높은 값을 나타내었다. 이외에도 공격성군은 대조군에 비해 충동성(impulsivity), 적대감(hostility), 정신증(psychoticism)등이 통계적으로 유의하게 높은 평균값을 보였다. 2) 공격성군은 대조군에 비하여 혈소판 이미프라민 최대결합부위 밀도(Bmax)가 낮은 경향을 보였다. 3) 공격성군과 대조군의 혈소판 이미프라민 결합의 결합상수(Kd) 값은 통계적으로 유의한 차이를 보이지 않았다. 4) 연구대상군을 전체로 하였을 때, 공격성척도(PFAV)와 갈등해결 척도(CTS)의 신체적 공격성의 심한 정도는 혈소판 이미프라민 최대결합부위 밀도(Bmax)와 통계적으로 유의한 정도의 역비례 상관관계를 보였다.

  • PDF

PDV를 이용한 가상 버퍼상의 AAL2 패킷 폐기 알고리즘과 성능분석 (Performance Analysis of AAL2 Packet Dropping Algorithm using PDV on Virtual Buffer)

  • 정다위;조영종
    • 대한전자공학회논문지TC
    • /
    • 제39권1호
    • /
    • pp.20-33
    • /
    • 2002
  • 패킷을 이용한 음성 서비스는 무선 망을 통한 음성 서비스 등으로 구현되고 있으며, 미래의 모든 음성 서비스는 패킷 기반형으로 진화할 것이다. 이러한 측면에서 ATM의 AAL2를 이용한 음성 패킷의 전달은 백본 망에서 음성 패킷의 전달 효율을 증가시키는 대표적인 방법이다. AAL2를 이용한 음성 서비스의 경우, 망의 자원이 허락되면 새로운 호의 연결을 수락한다. 하지만 새로운 호에 의해 발생되는 패킷으로 기존의 AAL2 연결의 전송 지연이 급격하게 증가할 가능성이 존재한다. 따라서 본 논문에서는 AAL2를 이용한 음성 서비스를 제공하는데 있어, AAL2 버퍼 관리 매카니즘으로 N개의 호에 대해 N개의 가상 버퍼를 통하여 각각의 호에 대한 전송지연변이를 계산하고, 전송 지연 변이에 따른 패킷 폐기 알고리즘을 제시한다. 이러한 패킷 폐기 알고리즘은 새로운 호의 수락으로 인해 발생하는 전송지연변이의 증가때문에 기존의 호의 QoS가 급격하게 악화되는 것을 방지한다. 그리고 종단 대 종단 지연에 영향을 미치는 AAL2 패킷 구성과 ATM 셀 구성의 요소를 분석하고, 음성 서비스를 ATM 셀로 만드는 과정을 K-정책을 갖는 M/D/1 큐잉시스템과 MIN(K, Tc) 정책을 갖는 M/D/1 큐잉 시스템으로 모델링함으로써, AAL2 패킷을 ATM 셀로 만드는 과정에서의 ATM 셀 밀집도와 AAL2 버퍼에서의 지연시간을 분석하였다. 제안하는 알고리즘을 모의 실험하여서 큐잉 시스템 모델링 결과와 비교하고 성능 결과를 분석하였다. 성능 분석 결과, AAL2 패킷 생성 시간과 ATM셀 생성 시간은 음성 소스의 갯수가 증가할 경우 전송 지연에 영향을 미치지 못하였으며, 제안하는 알고리즘은 음성 소스의 QoS를 저하하지 않은 수준에서 전송 지연을 낮게 유지할 수 있었다.

서로 다른 스캔 방식을 이용하여 CAD/CAM에 의해 제작된 코핑의 변연 및 내면의 적합성 (Marginal and Internal Fit of Copings Made by CAD/CAM using Different Scanning Methods)

  • 조영범;정재헌;김희중
    • 구강회복응용과학지
    • /
    • 제29권4호
    • /
    • pp.366-376
    • /
    • 2013
  • 구강내 스캔(Group 1), 모델 광학 스캔(Group 2)과 모델 접촉식 스캔(Group 3)방식으로 각각 zirconia 코핑을 제작하여 광학 현미경으로 적합성을 관찰하였다. 측정항목은 변연오차(absolute marginal discrepancy;AMD), 변연간극(marginal gap; MG), 측방간격(gap of axial wall; GA), 선각간격(gap of line angle; GL)와 교합간격(gap of occusal surface; GO)이었으며, 결과는 아래와 같았다. 1. Group 1, Group 2, Group 3의 평균 AMD는 각 각 $141.21{\pm}42.94{\mu}m$, $140.63{\pm}31.64{\mu}m$, $109.37{\pm}28.42{\mu}m$이고, Group1, Group 2, Group 3의 MG는 각 각 $82.52{\pm}43.99{\mu}m$, $90.28{\pm}27.93{\mu}m$, $66.55{\pm}28.77{\mu}m$였다. AMD와 MG는 각 그룹에서 통계학적으로 유의한 차이를 보여주지 않았다(Anova test, P>0.05). 2. Group 2의 GA가 Group 1과 Group 3에 비해 통계학적으로 유의하게 적은 수치를 나타내었다(Anova test, P<0.05). 3. Group 1의 GL과 GO가 다른 그룹에 비해 통계학적으로 높은 수치를 나타내었다(Mann-whitney test(P<0.05). 세 가지 스캔 방식으로 제작된 zirconia 코핑은 세라믹 보철의 가장 중요한 평가 요소인 AMD와 MG에서 서로 통계학적 차이를 보이지 않았다.

여러 레진계 치아고정 재료의 굴곡강도 및 탄성계수 비교 (Comparison of flexural strength and modulus of elasticity in several resinous teeth splinting materials)

  • 유제인;김수연;;김진우;박세희;조경모
    • 구강회복응용과학지
    • /
    • 제32권3호
    • /
    • pp.169-175
    • /
    • 2016
  • 목적: 본 연구의 목적은 수종의 레진계 치아고정 재료의 굴곡강도와 탄성계수를 비교 분석하는 것이다. 연구 재료 및 방법: 레진계 치아고정 재료로 Super-Bond C&B (SB), G-FIX (GF), G-aenial Universal Flo (GU), Filtek Z350 XT (FZ)를 이용하여 각 군당 15개씩 총 60개의 시편을 제작하였다. 3점 굽힘 시험으로 측정된 값에 따라 굴곡강도와 탄성계수를 계산하였다. 실험값은 One-way ANOVA test로 분석하고, Scheffe's test로 사후 검정하였다. 결과: 본 연구의 결과 SB는 다른 재료들과 비교 시 가장 낮은 굴곡강도를 보였으며 GF, GU, FZ는 비슷하게 높은 굴곡강도를 보였다. 탄성계수의 경우 SB가 가장 낮은 값을 보였고 GF는 SB보다는 높지만 GU와 FZ보다는 낮은 탄성계수를 보였으며 GU와 FZ는 유의하게 높은 탄성계수를 보였다. 결론: 동요치 고정을 목적으로 새로 개발된 GU (G-FIX)는 유동성 복합 레진과 수복용 복합 레진과 같이 높은 강도를 보이며 잘 파절되지 않으면서도 상대적으로 유연한 성질을 보여 동요치 고정에 유리할 것으로 사료된다.