• Title/Summary/Keyword: Mean Load

Search Result 975, Processing Time 0.027 seconds

Frequency Domain Analysis for Hydrodynamic Responses of Floating Structure using Desingularized Indirect Boundary Integral Equation Method (비특이화 간접경계적분방정식 방법을 이용한 부유식 구조물의 유체동역학적 거동에 대한 주파수영역 해석)

  • Oh, Seunghoon;Jung, Dongho;Cho, Seok-kyu;Nam, Bo-woo;Sung, Hong Gun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.1
    • /
    • pp.11-22
    • /
    • 2019
  • In this paper, a Rankine source method is applied and validated to analyze the hydrodynamic response of a three-dimensional floating structure in the frequency domain. The boundary value problems for radiation and diffraction problem are solved by using a desingularized indirect boundary integral equation method (DIBIEM). The DIBIEM is simpler and faster than conventional methods based on the numerical surface integration of Green's function because the singularities of Green's function are located outside of fluid regions. In case of floating structure with complex geometry, it is difficult to desingularize the singularities of Green's function consistently. Therefore a mixed approach is carried out in this study. The mixed approach is partially desingularized except singularities of the body. Wave drift loads are calculated by the middle-field formulation method that is mathematically simple and has fast convergence. In order to validate the accuracy of the developed program, various numerical simulations are carried out and these results are analyzed and compared with previously published calculations and experiments.

Effects of different wind deflectors on wind loads for extra-large cooling towers

  • Ke, S.T.;Zhu, P.;Ge, Y.J.
    • Wind and Structures
    • /
    • v.28 no.5
    • /
    • pp.299-313
    • /
    • 2019
  • In order to examine the effects of different wind deflectors on the wind load distribution characteristics of extra-large cooling towers, a comparative study of the distribution characteristics of wind pressures on the surface of three large cooling towers with typical wind deflectors and one tower without wind deflector was conducted using wind tunnel tests. These characteristics include aerodynamic parameters such as mean wind pressures, fluctuating wind pressures, peak factors, correlation coefficients, extreme wind pressures, drag coefficients and vorticity distribution. Then distribution regularities of different wind deflectors on global and local wind pressure of extra-large cooling towers was extracted, and finally the fitting formula of extreme wind pressure of the cooling towers with different wind deflectors was provided. The results showed that the large eddy simulation (LES) method used in this article could be used to accurately simulate wind loads of such extra-large cooling towers. The three typical wind deflectors could effectively reduce the average wind pressure of the negative pressure extreme regions in the central part of the tower, and were also effective in reducing the root of the variance of the fluctuating wind pressure in the upper-middle part of the windward side of the tower, with the curved air deflector showing particularly. All the different wind deflectors effectively reduced the wind pressure extremes of the middle and lower regions of the windward side of the tower and of the negative pressure extremes region, with the best effect occurring in the curved wind deflector. After the wind deflectors were installed the drag coefficient values of each layer of the middle and lower parts of the tower were significantly higher than that without wind deflector, but the effect on the drag coefficients of layers above the throat was weak. The peak factors for the windward side, the side and leeward side of the extra-large cooling towers with different wind deflectors were set as 3.29, 3.41 and 3.50, respectively.

Change of Head Position and Muscle Activities of Neck During Overhead Arm Lift Test in Subjects With Forward Head Posture

  • Kim, Tae-ho;Hwang, Byoung-ha
    • Physical Therapy Korea
    • /
    • v.26 no.2
    • /
    • pp.61-68
    • /
    • 2019
  • Background: Forward head posture (FHP) is a postural alignment of the cervical vertebrae that leads to increased gravitational load on cervical segmental motions. The overhead arm lift test assesses the ability to actively dissociate and control low cervical flexion and move the shoulders through overhead flexion. Objects: The purpose of this study was to explore muscle activities in the upper trapezius (UT), serratus anterior (SA), sternocleidomastoid (SCM), and lower trapezius (LT) alongside changes in head position during the overhead arm lift test in individuals with FHP. Methods: Fifteen subjects with forward head posture and fifteen subjects with normal subjcects were enrolled in this study. The patients performed the overhead arm lift test, and muscle activities of the UT, SCM, SA, and LT were measured using surface electromyography and by evaluating changes in head position. Independent t-tests were used to detect significant differences between the two groups and Cohen's d was calculated to measure the size of the mean difference between the groups. Results: The FHP group demonstrated significantly increased muscle activity of the UT ($32.46{\pm}7.64$), SCM ($12.79{\pm}4.01$), and LT ($45.65{\pm}10.52$) and significantly decreased activity in the SA ($26.65{\pm}6.15$) than the normal group. The change in head position was significantly higher in the FHP group ($6.66{\pm}2.08$) than the normal group. Effect sizes for all parameters assessed were large between the two groups. Conclusion: The subjects with excessive FHP displayed were unable to fix their heads in position during the overhead arm lift test. The overhead arm lift test can thus be used in clinical settings to confirm control of the neck in these subjects.

Pull-off resistance of a screwless implant-abutment connection and surface evaluation after cyclic loading

  • Alevizakos, Vasilios;Mosch, Richard;Mitov, Gergo;Othman, Ahmed;See, Constantin von
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.3
    • /
    • pp.152-159
    • /
    • 2021
  • Purpose. The aim of this study was to investigate to what extent cyclic load affects the screwless implant-abutment connection for Morse taper dental implants. Materials and Methods. 16 implants (SICvantage max) and 16 abutments (Swiss Cross) were used. The screwless implant-abutment connection was subjected to 10,000 cycles of axial loading with a maximum force of 120 N. For the pull-off testing, before and after the same cyclic loading, the required force for disconnecting the remaining 6 implant-abutment connections was measured. The surface of 10 abutments was examined using a scanning electron microscope 120× before and after loading. Results. The pull-off test showed a significant decrease in the vertical force required to pull the abutment from the implant with mean 229.39 N ± 18.23 before loading, and 204.30 N ± 13.51 after loading (P<.01). Apart from the appearance of polished surface areas and slight signs of wear, no visible damages were found on the abutments. Conclusion. The deformation on the polished abutment surface might represent the result of micro movements within the implant-abutment connection during loading. Although there was a decrease of the pull-off force values after cyclic loading, this might not have a notable effect on the clinical performance.

Signal Processing of Guide Sensor based on Multi-Masking and Center of Gravity Method for Automatic Guided Vehicle (다중 마스킹과 무게중심법을 기반한 AGV용 가이드 센서 신호처리)

  • Lee, Byeong-Ro;Lee, Ju-Won
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.79-84
    • /
    • 2021
  • The most important device of the AGV is the guide sensor, and the typical function of this sensor is high accuracy and extraction of the road. If the accuracy of the guide sensor is low or the sensor device is extracted the wrong track, this causes the problems such as the AGV collision, track-out, the load falling due to AGV swing. In order to improve these problems, this study is proposed a signal processing method of the guide sensor based on multi-maskings and the center of gravity method, and evaluated its performance. As a result, the proposed method showed that the mean error of absolute value is 2.32[mm] and it showed performance improvement of 27[%] than the center of gravity method of existence. Therefore, when the proposed signal processing method is applied, It is thought that the posture control and driving stability of the AGV will be improved.

Bond-slip behaviour of H-shaped steel embedded in UHPFRC

  • Huang, Zhenyu;Huang, Xinxiong;Li, Weiwen;Chen, Chufa;Li, Yongjie;Lin, Zhiwei;Liao, Wen-I
    • Steel and Composite Structures
    • /
    • v.38 no.5
    • /
    • pp.563-582
    • /
    • 2021
  • The present study experimentally and analytically investigated the push-out behaviour of H-shaped steel section embedded in ultrahigh-performance fibre-reinforced concrete (UHPFRC). The effect of significant parameters such as the concrete types, fibre content, embedded steel length, transverse reinforcement ratio and concrete cover on the bond stress, development of bond stress along the embedded length and failure mechanism has been reported. The test results show that the bond slip behaviour of steel-UHPFRC is different from the bond slip behaviour of steel-normal concrete and steel-high strength concrete. The bond-slip curves of steel-normal concrete and steel-high strength concrete exhibit brittle behaviour, and the bond strength decreases rapidly after reaching the peak load, with a residual bond strength of approximately one-half of the peak bond strength. The bond-slip curves of steel-UHPFRC show an obvious ductility, which exhibits a unique displacement pseudoplastic effect. The residual bond strength can still reach from 80% to 90% of the peak bond strength. Compared to steel-normal concrete, the transverse confinement of stirrups has a limited effect on the bond strength in the steel-UHPFRC substrate, but a higher stirrup ratio can improve cracking resistance. The experimental campaign quantifies the local bond stress development and finds that the strain distribution in steel follows an exponential rule along the steel embedded length. Based on the theory of mean bond and local bond stress, the present study proposes empirical approaches to predict the ultimate and residual bond resistance with satisfactory precision. The research findings serve to explain the interface bond mechanism between UHPFRC and steel, which is significant for the design of steel-UHPFRC composite structures and verify the feasibility of eliminating longitudinal rebars and stirrups by using UHPFRC in composite columns.

Comparative analysis on intaglio surface trueness, wear volume loss of antagonist, and fracture resistance of full-contour monolithic zirconia crown for single-visit dentistry under simulated mastication

  • Kim, Yong-Kyu;Yoon, Hyung-In;Kim, Dae-Joon;Han, Jung-Suk
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.3
    • /
    • pp.173-181
    • /
    • 2022
  • PURPOSE. This analysis aimed to evaluate the intaglio surface trueness, antagonist's wear volume loss, and fracture resistance of full-contour crowns of (Y, Nb)-stabilized fully-sintered zirconia (FSZ), 4 mol% or 5 mol% yttria-stabilized partially sintered zirconia (4YZ or 5YZ) with high-speed sintering. MATERIALS AND METHODS. A total of 42 zirconia crowns were separated into three groups: FSZ, 4YZ, and 5YZ (n = 14). The intaglio surface trueness of the crowns was evaluated at the inner surface, occlusal, margin, and axial areas and reported as root-mean-square, positive and negative average deviation. Half of the specimens were aged for 120,000 cycles in the chewing simulator, and the wear volume loss of antagonist was measured. Before and after chewing, the fracture load was measured for each group. The trueness values were analyzed with Welch's ANOVA, and the wear volume loss with the Kruskal-Wallis tests. Effect of the zirconia type and aging on fracture resistance of crowns was tested using two-way ANOVA. RESULTS. The intaglio surface trueness measured at four different areas of the crown was less than 50 ㎛, regardless of the type of zirconia. No significant P in wear volume loss of antagonists were detected among the groups (P > .05). Both the type of zirconia and aging showed statistically significant effects on fracture resistance (P < .05). CONCLUSION. The full-contour crowns of FSZ as well as 4YZ or 5YZ with high-speed sintering were clinically acceptable, in terms of intaglio surface trueness, antagonist's wear volume loss, and fracture resistance after simulated mastication.

Differences In Joint Position Sense, Force Sense, and Performance Level of the Upper Extremities According to the Sex, Injury and Pain Experiences of Korean Elite Archers (한국 엘리트 양궁선수들의 성별과 부상, 통증 경험에 따른 상지의 관절위치 감각과 힘감각, 경기력 수준의 차이)

  • Kim, Mun-kyo;Kim, Suhn-yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.27 no.3
    • /
    • pp.1-15
    • /
    • 2021
  • Objective: The purpose of this study was to examine the differences in joint position sense (JPS), force sense (FS), and performance level of the upper extremities according to the injury and pain experiences of Korean elite archers. Methods: A total of 15 subjects were briefed about the purpose of this study and agreed to participate voluntarily. JPS was evaluated using the laser-point attached to the wrist while aiming at the target. The difference when relocating while aiming was used as JPS factor. FS was evaluated using load cell through reproduces same muscle strength. Fear-Avoidance Beliefs Questionnaire (FABQ) was used to evaluate psychosocial factors, Kerlan-Jobe Orthopedic Clinic overhead athlete scores (KJOC) and numerical rating scale (NRS) was used to evaluate pain. and performance was evaluated by tournament match score. Results: There is a strong correlation between the current pain and KJOC. Moreover, moderate correlation between KJOC and FABQ also current pain and both upper trapezius and lower trapezius in elite archers. The mean (SD) between groups based on current pain display relatively large margin in force sense than without pain group. The result presents that there is a significant difference in performance and pain. There is a significant difference in the force sense of the upper and lower trapezius and pain. Conclusions: Result present there is a significant difference in functional level in the average comparison between groups according to the presence of absence of current pain. There is a significant difference in the force sense of the upper trapezius as well as lower trapezius and without pain group present a relatively low joint position sense error compared to the groups.

Impact response of a novel flat steel-concrete-corrugated steel panel

  • Lu, Jingyi;Wang, Yonghui;Zhai, Ximei;Zhou, Hongyuan
    • Steel and Composite Structures
    • /
    • v.42 no.2
    • /
    • pp.277-288
    • /
    • 2022
  • A novel flat steel plate-concrete-corrugated steel plate (FS-C-CS) sandwich panel was proposed for resisting impact load. The failure mode, impact force and displacement response of the FS-C-CS panel under impact loading were studied via drop-weight impact tests. The combined global flexure and local indentation deformation mode of the FS-C-CS panel was observed, and three stages of impact process were identified. Moreover, the effects of corrugated plate height and steel plate thickness on the impact responses of the FS-C-CS panels were quantitatively analysed, and the impact resistant performance of the FS-C-CS panel was found to be generally improved on increasing corrugated plate height and thickness in terms of smaller deformation as well as larger impact force and post-peak mean force. The Finite Element (FE) model of the FS-C-CS panel under impact loading was established to predict its dynamic response and further reveal its failure mode and impact energy dissipation mechanism. The numerical results indicated that the concrete core and corrugated steel plate dissipated the majority of impact energy. In addition, employing end plates and high strength bolts as shear connectors could prevent the slip between steel plates and concrete core and assure the full composite action of the FS-C-CS panel.

Protocatechuic acid impacts rotator cuff healing and reduces fatty degeneration in a chronic rotator cuff tear model in rats

  • Seo, Su-Jung;Park, Jae-Young;Park, Hyoung-Jin;Hwang, Jung-Taek
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.1
    • /
    • pp.5-14
    • /
    • 2022
  • Background: The purpose of this study was to verify the effect of protocatechuic acid (PCA) on tendon healing and fatty degeneration in a chronic rotator cuff model. Methods: Twenty-eight Sprague-Dawley male rats were randomly allocated into two groups: Saline+repair (SR) and PCA+repair (PR). The right shoulder was used for experimental interventions, and the left served as a control. PCA (30 mg/kg/day) was administered intraperitoneally at the site of infraspinatus tendon detachment in rats in the PR group, and the same volume of saline was administered to the same site in the SR group. The torn tendon was repaired 4 weeks after infraspinatus detachment. Four weeks after repair, hematoxylin and eosin (H&E), S100, and CD68 stains were performed to evaluate the degree of fatty degeneration and H&E and Masson trichrome stains were performed to assess tendon healing. Superoxide dismutase (SOD) was measured to test the efficacy of PCA as an antioxidant. Results: Results from histological evaluation indicated that SOD and CD68 levels at the musculotendinous region and collagen fiber parallel to the orientation at the tendon-to-bone junction were not significantly different between the SR and PR groups. The mean load-to-failure of the PR group (20.32±9.37 N) was higher than that of the SR group (16.44±6.90 N), although this difference was not statistically significant (p=0.395). The SOD activity in the operative side infraspinatus muscle of the PR group was higher than that of the SR group, but the difference was not statistically significant (p=0.053). Conclusions: The use of PCA could improve tendon healing and decrease fatty degeneration after rotator cuff repair.