• 제목/요약/키워드: Maximum wind speed

검색결과 601건 처리시간 0.027초

Characteristics of Sea Breezes at Coastal Area in Boseong (보성 해안 지역에서의 해풍 특성)

  • Lim, Hee-Jeong;Lee, Young-Hee
    • Atmosphere
    • /
    • 제29권1호
    • /
    • pp.41-51
    • /
    • 2019
  • The characteristics of the sea breeze were investigated using the wind and temperature data collected from 300-m tower at Boseong from May 2014 to April 2018. Sea breeze day was detected using following criteria: 1) the presence of a clear change in wind direction near sunrise (between 1 hour after sunrise and 5 hours before sunset) and sunset (from 1500 LST to midnight), 2) presence of thermal forcing of sea breeze and 3) no heavy precipitation (rain < $10mm\;d^{-1}$). Sea breeze days occurred on 569 days for 4 years. The monthly distribution of sea breeze day occurrence shows maxima in May and September and minimum in December. The average onset and cessation times of the sea breeze are 0942 LST and 1802 LST, respectively. Although the 10-m wind shows clockwise rotation with time in the afternoon, the observed hodograph does not show an ideal elliptical shape and has different characteristics depending on the upper synoptic wind direction. Vertical structure of sea breeze shows local maximum of wind speed and local minimum of virtual potential temperature at 40 m in the afternoon for most synoptic conditions except for southeasterly synoptic wind ($60^{\circ}{\sim}150^{\circ}$) which is in the same direction as onshore flow. The local minimum of temperature is due to cold advection by sea breeze. During daytime, the intensity of inversion layer above 40 m is strongest in westerly synoptic wind ($240^{\circ}{\sim}330^{\circ}$) which is in the opposite direction to onshore flow.

Performance Improvement of a Temperature and Humidity Measuring System for Strawberry Cultivation Greenhouse (딸기재배 온실용 온습도 계측시스템의 성능개선)

  • Jeong, Young Kyun;Lee, Jong Goo;Ahn, Enu Ki;Seo, Jae Seok;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • 제29권2호
    • /
    • pp.110-119
    • /
    • 2020
  • This study investigates the improvement in the performance of a temperature and humidity measuring system developed by Company A using the Aspirated Radiation Shield (ARS). The shield has been used in the industry and its accuracy was verified recently. The study also experimentally examines the impact of the wind speed of the ARS device on temperature and humidity. The results are summarized as follows. Before the improvement of the system, the temperature of Company A's system was up to 10.2℃ higher than that measured by the ARS device, and the measured relative humidity was approximately 20.0% lower. After improving the system, the temperature and relative humidity of nodes 1 and 2 were found to be almost identical. The temperature deviations including the maximum, mean, and minimum temperatures between those measured in node 2 and by ARS were approximately 0.2 to 0.7℃, respectively; further, the values measured by ARS tended to be slightly lower or higher. In terms of relative humidity, the ARS measurements yielded values approximately 10.0% higher immediately after sunset; otherwise, the values were approximately 1.9% lower. Moreover, when node 1 was set to minimum-middle, middle-maximum, and maximum, the deviations including the maximum, mean, and minimum temperatures of nodes 1 and 2 were 0.1 to 0.4℃, 0.0 to 0.2℃, and 0.0 to 0.5℃, respectively. The deviations including the maximum, average, and minimum temperatures of the three points of node 1 and the ARS ranged from 0.2 to 0.5℃, 0.1 to 2.2℃, and 0.1 to 1.1℃, respectively, indicating that the temperature deviation according to the wind speed was negligible. In addition, considering the results of the previous study with those from this study, the optimal wind speed to improve the temperature deviation is considered to be in the range of 1.0~2.0 m·s-1.

Variations of the Summertime Tropical Cyclone Intensity near 30°N in East Asia (동아시아의 30°N부근에서 여름철 태풍 강도변화)

  • Choi, Ki-Seon;Kim, Baek-Jo;Lee, Seong-Lo;Kim, Ho-Kyung;Lee, Ji-Sun
    • Journal of Environmental Science International
    • /
    • 제18권10호
    • /
    • pp.1089-1101
    • /
    • 2009
  • In this paper, changes in the intensity (e.g., central pressure and maximum sustained wind speed) of Tropical Cyclone (TC) in summer in the regions located at $30^{\circ}N$ in East Asia from 1988 to 1991 were found. The intensity of TC from 1991 to 2007 was much higher than that of TC from 1965 to 1988. The reason for this was that the frequency of TCs passing China from 1991 to 2007 was much lower than that of TCs from 1965-1988 because a northeasterly wind caused by high-pressure circulation in East Asia got severer along the East Asian coast. Instead, TCs moved from the eastern region of the Tropical West Pacific to Korea and Japan mainly after passing the East China Sea due to the low-pressure circulation strengthened in the subtropical waters of East Asia. In addition, low Vertical Wind Shear (VWS) was created along the mid-latitude regions of East Asia and the main path of TCs from 1991 to 2007. Most of the regions in the Northwestern Pacific showed higher Sea Surface Temperature (SST) from 1991 to 2007, and had a good environment where TCs were able to maintain a higher intensity on the mid-latitude. In particular, a low sensible heat flux occurred due to high snow depth in East Asia in the spring of 1991 to 2007. Accordingly, the lower layer of East Asia showed high-pressure circulation, and the sea surrounding East Asia showed low-pressure circulation. Thus, the typical west-high, east-low pattern of winter atmospheric pressure was shown. The possibility of snowfall in East Asia in spring to be used as a factor for predicting the summer intensity of TC in the mid-latitude regions of East Asia was insinuated. The characteristics of TC in a low-latitude region were the same in Korea. The latest intensity of TCs got higher, and the landing location of TCs gradually changed from the west coast to the south coast.

Evaluation of the Intensity Predictability of the Numerical Models for Typhoons in 2013 (2013년 태풍에 대한 수치모델들의 강도 예측성 평가)

  • Kim, Ji-Seon;Lee, Woojeong;Kang, KiRyong;Byun, Kun-Young;Kim, Jiyoung;Yun, Won-Tae
    • Atmosphere
    • /
    • 제24권3호
    • /
    • pp.419-432
    • /
    • 2014
  • An assessment of typhoon intensity predictability of numerical models was conducted to develop the typhoon intensity forecast guidance comparing with the RSMC-Tokyo best track data. Root mean square error, box plot analysis and time series of wind speed comparison were performed to evaluate the each model error level. One of noticeable fact is that all models have a trend of error increase as typhoon becomes stronger and the Global Forecast System showed the best performance among the models. In the detailed analysis in two typhoon cases [Danas (1324) and Haiyan (1330)], GFS showed good performance in maximum wind speed and intensity trend in the best track, however it could not simulate well the rapid intensity increasing period. On the other hand, ECMWF and Hurricane-WRF overestimated the typhoon intensity but simulated track trend well.

Control of nonlinear production-distribution process with limited decision policy (최대구매 제한을 갖는 비선형 생산분배계의 제어)

  • 정상화;정상표;오용훈
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제14권3호
    • /
    • pp.156-165
    • /
    • 1997
  • In the practical control systems, the dynamic range of actuatiors is limited(or saturated) when actuators are driven by sufficiently large signals. This gives rise to a nonlinearity as a result of actuator saturation. For example, the upper limit is imposed on productive capability by available factory space and capital equipment. Other examples of those kinds of actuator saturations are a maximum torque of the actua- ting motors and a throttle position in an aircraft speed control A saturating actuator may lead not only to a large overshoot during start-up and shut-down, but also to deterioration of the performance due to the uncertainties. That is, the speed of response is decreased and, possibly, the system output may not follow the lalrge reference inputs. The large-overshoot may be accompanied by rest wind-up(or called by integra- tor wind-up) which comes from controllers with integral action in saturation operation regions. Eventually, as the overshoot increases, the system has a limit cycle or becomes oscillatorily unstable. Due to these cir- cumstances, many studies are focused on the stability and robustness of the nonlinear systems with satu- rating actuator in the time-domain as well as in the frequency-domain.

  • PDF

Uncertainty Analysis of Dynamic Thermal Rating of Overhead Transmission Line

  • Zhou, Xing;Wang, Yanling;Zhou, Xiaofeng;Tao, Weihua;Niu, Zhiqiang;Qu, Ailing
    • Journal of Information Processing Systems
    • /
    • 제15권2호
    • /
    • pp.331-343
    • /
    • 2019
  • Dynamic thermal rating of the overhead transmission lines is affected by many uncertain factors. The ambient temperature, wind speed and wind direction are the main sources of uncertainty. Measurement uncertainty is an important parameter to evaluate the reliability of measurement results. This paper presents the uncertainty analysis based on Monte Carlo. On the basis of establishing the mathematical model and setting the probability density function of the input parameter value, the probability density function of the output value is determined by probability distribution random sampling. Through the calculation and analysis of the transient thermal balance equation and the steady- state thermal balance equation, the steady-state current carrying capacity, the transient current carrying capacity, the standard uncertainty and the probability distribution of the minimum and maximum values of the conductor under 95% confidence interval are obtained. The simulation results indicate that Monte Carlo method can decrease the computational complexity, speed up the calculation, and increase the validity and reliability of the uncertainty evaluation.

Laboratory investigation of the effects of translation on the near-ground tornado flow field

  • Razavi, Alireza;Sarkar, Partha P.
    • Wind and Structures
    • /
    • 제26권3호
    • /
    • pp.179-190
    • /
    • 2018
  • Translation of tornadoes is an important feature in replicating the near-ground tornado flow field which has been simulated in previous studies based on Ward-type tornado simulators using relative motion of the ground plane. In this laboratory investigation, effects of translation on the near-ground tornado flow field were studied using the ISU Tornado Simulator that can physically translate over a ground plane. Two translation speeds, 0.15 m/s and 0.50 m/s, that scale up to those corresponding to slowly-moving tornadoes in the field were selected for this study. Compared with the flow field of a stationary tornado, the simulated tornado with translation had an influence on the spatial distribution and magnitude of the horizontal velocities, early reversal of the radial inflow, and expansion of the core radius. Maximum horizontal velocities were observed to occur behind the center of the translating tornado and on the right side of its mean path. An increase in translation speed, resulted in reduction of maximum horizontal velocities at all heights. Comparison of the results with previous studies that used relative motion of the ground plane for simulating translating tornadoes, showed that translation has similar effects on the flow field at smaller radial distances (~2 core radius), but different effects at larger radial distances (~4 core radius). Further, it showed that the effect of translation on velocity profiles is noticeable at and above an elevation of ~0.6 core radius, unlike those in studies based on the relative motion of the ground plane.

Mixed Layer Variability in Northern Arabian Sea as Detected by an Argo Float

  • Bhaskar, T.V.S. Udaya;Swain, D.;Ravichandran, M.
    • Ocean Science Journal
    • /
    • 제42권4호
    • /
    • pp.241-246
    • /
    • 2007
  • Northern Arabian Sea (NAS) between $17^{\circ}N-20.5^{\circ}N$ and $59^{\circ}E-69^{\circ}E$ was observed by using Argo float daily data fur about 9 months, from April 2002 through December 2002. Results showed that during April - May mixed layer shoaled due to light winds, clear sky and intense solar insolation. Sea surface temperature (SST) rose by $2.3^{\circ}C$ and ocean gained an average of 99.8 $Wm^{-2}$. Mixed layer reached maximum depth of about 71 m during June - September owing to strong winds and cloudy skies. Ocean gained abnormally low $\sim18Wm^{-2}$ and SST dropped by $3.4^{\circ}C$. During the inter monsoon period, October, mixed layer shoaled and maintained a depth of 20 to 30 m. November - December was accompanied by moderate winds, dropping of SST by $1.5^{\circ}C$ and ocean lost an average of 52.5 $Wm^{-2}$. Mixed layer deepened gradually reaching a maximum of 62 m in December. Analysis of surface fluxes and winds suggested that winds and fluxes are the dominating factors causing deepening of mixed layer during summer and winter monsoon periods respectively. Relatively big]h correlation between MLD, net heat flux and wind speed revealed that short term variability of MLD coincided well with short term variability of surface forcing.

Characteristics of the Ultrasonic Motors of Single - Phase Driving Type (단상 구동형 초음파 전동기의 특성)

  • Kim, J.S.;Kim, Y.H.;Lee, N.H.;Kim, H.G.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.282-284
    • /
    • 1997
  • Ultrasonic motors using piezoelectric ceramics and brass metal endcaps were fabricated, which is operated by single - phase high frequency. The structure of the ultrasonic motors has the wind-mill type. The stator part consists of a piezoelectric disk and two metal endcaps slotted wind-mill type. According to the piezoceramic disk vibrates as a radial mode, two metal endcaps provide both longitudinal and torsional displacements simultaneously. Because the metal endcaps have a nonsymmetric structure. the principle of the ultrasonic motor is not well understood. The dimension of the ultrasonic motor is diameter in 12.7 mm and thickness in 2.0 mm, and especially the PMN-PT-PZ piezoelectric disk was used. The maximum revolution speed 700 rpm and the maximum torque 0.22 mN.m were obtained. The ultrasonic motor for rotation was Supplied only single phase AC.

  • PDF

Characteristics of Surface High Ozone Concentration on Pusan Coastal area, Korea (부산 해안지역의 고농도 오존 발생 특성에 관한 연구)

  • 전병일
    • Journal of Environmental Science International
    • /
    • 제9권4호
    • /
    • pp.295-302
    • /
    • 2000
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone, nitrogen dioxide and meteorological data for 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was the highest at Dongsamdong in Spring(35.4ppb), at Kwangbokdong in Fall(25.1ppb) and the lowest Dongsamdong(22.2ppb) and Kwangbokdong(16.0ppb) in Winter. Relative standard deviation indicating clearness of observation site was 0.42 at Dongsamdong and 0.49 at Kwangbokdong that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong and Kwangbokdong showed maximum at 1500~1600LST and minimum 0700~0800LST that typical pattern of ozone concentration. In ozone episode period(Sept. 10~15, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface. During the episode days peak ozone concentrations are much higher than the normal values, wind speeds are always lower, and solar radiation is high with the exception of the September episode.

  • PDF