The influence of various core designs on stress distribution in the veneered zirconia crown: a finite element analysis study

  • Ha, Seung-Ryong;Kim, Sung-Hun;Han, Jung-Suk;Yoo, Seung-Hyun;Jeong, Se-Chul;Lee, Jai-Bong;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.187-197
    • /
    • 2013
  • PURPOSE. The purpose of this study was to evaluate various core designs on stress distribution within zirconia crowns. MATERIALS AND METHODS. Three-dimensional finite element models, representing mandibular molars, comprising a prepared tooth, cement layer, zirconia core, and veneer porcelain were designed by computer software. The shoulder (1 mm in width) variations in core were incremental increases of 1 mm, 2 mm and 3 mm in proximal and lingual height, and buccal height respectively. To simulate masticatory force, loads of 280 N were applied from three directions (vertical, at a $45^{\circ}$ angle, and horizontal). To simulate maximum bite force, a load of 700 N was applied vertically to the crowns. Maximum principal stress (MPS) was determined for each model, loading condition, and position. RESULTS. In the maximum bite force simulation test, the MPSs on all crowns observed around the shoulder region and loading points. The compressive stresses were located in the shoulder region of the veneer-zirconia interface and at the occlusal region. In the test simulating masticatory force, the MPS was concentrated around the loading points, and the compressive stresses were located at the 3 mm height lingual shoulder region, when the load was applied horizontally. MPS increased in the shoulder region as the shoulder height increased. CONCLUSION. This study suggested that reinforced shoulder play an essential role in the success of the zirconia restoration, and veneer fracture due to occlusal loading can be prevented by proper core design, such as shoulder.

Comparison of Strain on Dental Cervical Line between Tooth Fracture Test and Finite Element Analysis (치아파절시험과 유한요소해석에서의 치경 변형률에 관한 연구)

  • Yoo, Oui-Sik;Chun, Keyoung-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.4
    • /
    • pp.87-94
    • /
    • 2010
  • When occlusal force is applied to a tooth, stress concentration occurs on the dental cervical line. This study investigated to find the maximum force and strain of natural teeth using an Instron and strain gauges, comparing the strain of cervical enamel using finite element analysis(FEA). Tests were conducted with a mandibular first premolar applying the conditions of occlusion. Then, the FEA was processed with the same as conditions of the fracture test. The test showed that the maximum force, maximum compressive strain and maximum tensional strain was $278{\pm}26$ N, $0.668{\times}10^{-3}{\pm}0.678{\times}10^{-3}$ and $0.248{\times}10^{-3}{\pm}0.102{\times}10^{-3}$, respectively. It was found that six of eight measured strains were within the range of estimated strains by the FEA. Even though it was assumed that properties of FE models were isotropic, it could prove useful as a reference in understanding the tendency of dental strain.

An evaluation of the stress effect of different occlusion concepts on hybrid abutment and implant supported monolithic zirconia fixed prosthesis: A finite element analysis

  • Yesilyurt, Nilgün Gulbahce;Tuncdemir, Ali Riza
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.216-225
    • /
    • 2021
  • PURPOSE. The aim of this study is to evaluate the effects of canine guidance occlusion and group function occlusion on the degree of stress to the bone, implants, abutments, and crowns using finite element analysis (FEA). MATERIALS AND METHODS. This study included the implant-prosthesis system of a three-unit bridge made of monolithic zirconia and hybrid abutments. Three-dimensional (3D) models of a bone-level implant system and a titanium base abutment were created using the original implant components. Two titanium implants, measuring 4 × 11 mm each, were selected. The loads were applied in two oblique directions of 15° and 30° under two occlusal movement conditions. In the canine guidance condition, loads (100 N) were applied to the canine crown only. In the group function condition, loads were applied to all three teeth. In this loading, a force of 100 N was applied to the canine, and 200-N forces were applied to each premolar. The stress distribution among all the components of the implant-bridge system was assessed using ANSYS SpaceClaim 2020 R2 software and finite element analysis. RESULTS. Maximum stress was found in the group function occlusion. The maximum stress increased with an increase in the angle of occlusal force. CONCLUSION. The canine guidance occlusion with monolithic zirconia crown materials is promising for implant-supported prostheses in the canine and premolar areas.

Material Characteristics of Dental Implant System with In-Vitro Mastication Loading

  • Jeong, Tae-Gon;Jeong, Yong-Hun;Lee, Su-Won;Yang, Jae-Ung;Jeong, Jae-Yeong;Park, Gwang-Min;Gang, Gwan-Su
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.72-72
    • /
    • 2018
  • A dynamic fatigue characteristic of dental implant system has been evaluated with applying single axial compressive shear loading based on the ISO 14801 standard. For the advanced dynamic fatigue test, multi-directional force and motion needed to be accompanied for more information of mechanical properties as based on mastication in oral environment. In this study, we have prepared loading and motion protocol for the multi-directional fatigue test of dental implant system with single (Apical/Occlusal; AO), and additional mastication motion (Lingual/Facial; LF, Mesial/Distal; MD). As following the prepared protocol (with modification of ISO 14801), fatigue test was conducted to verify the worst case results for the development of highly stabilized dental implant system. Mechanical testing was performed using an universal testing machine (MTS Bionix 858, MN, USA) for static compression and single directional loading fatigue, while the multi-directional loading was performed with joint simulator (ADL-Force 5, MA, USA) under load control. Basically, all mechanical test was performed according to the ISO 14801:2016 standard. Static compression test was performed to identify the maximum fracture force with loading speed of 1.0 mm/min. A dynamic fatigue test was performed with 40 % value of maximum fracture force and 5 Hz loading frequency. A single directional fatigue test was performed with only apical/occlusal (AO) force application, while multi directional fatigue tests were applied $2^{\circ}$ of facial/lingual (FL) or mesial/distal (MD) movement. Fatigue failure cycles were entirely different between applying single-directional loading and multi-directional loading. As a comparison of these loading factor, the failure cycle was around 5 times lower than single-directional loading while applied multi-directional loading. Also, the displacement change with accumulated multi-directional fatigue cycles was higher than that of single directional cycles.

  • PDF

Nocturnal Bruxism and Botulinum Toxin Effect on the Subjects with Masseteric Hypertrophy (야간 이갈이와 교근비대 환자의 보툴리눔 독소 주사 효과)

  • Sohn, Seung-Mahn;Chung, Gi-Chung;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.337-346
    • /
    • 2007
  • This study aimed to evaluate a relation of bruxism with clinical effects of botulinum toxin type A(BTX-A) injection. 5 bruxers and 5 nonbruxers with bilateral masseter hypertrophy were participated in this study. After injecting 25 unit of BTX-A(Allergen Inc, $Botox^{(R)}$) into each masseter muscle, the thickness of masseter(Mm) and anterior temporalis(Ta) muscles was measured by ultrasonography and the maximum bite force was evaluated during a 9-month period. Self-estimation on the recovery of occlusal force during mastication was done as well. Regardless of presence of bruxsim, all subjects showed significantly reduced Ms thickness(p<0.001) and maximum bite force at $1^{st}$ molars(p=0.027) with their peak at 3 months after injection, which then started to return. No significant difference was observed in Ta thickness and the bite force at the central incisors. While self-estimated occlusal force was the least at 2 weeks after injection and then rapidly returned to the baseline level with full recovery at the time of 6 to 9 months after injection, the maximum bite force measured by bite force recorder did not recover the original value, particularly in the nonbruxer group. It is assumed that nocturnal bruxism can influence recovery of atrophic masseter and decreased occlusal force due to BTX-A injection. These findings suggest a need of occlusal appliance to control bruxism or clenching habit for longer clinical effect of BTX-A injection.

The 3-Dimensional Finite Element Analysis of Minimum Implant Structure for Edentulous Jaw (무치악에 대한 최소 임플란트의 구조물의 3차원 유한요소 해석)

  • Jang, In-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.2
    • /
    • pp.148-155
    • /
    • 2008
  • The aim of the study is to interpret the distribution of occlusal force by 3-dimensional finite element analysis of ISP(Implant Supported Prosthesis) supported by minimum number of implant to restore the edentulous patients. For this study, the Astra Tech implant system is used. Geometric modeling for 6 and 4 fixture ISP group is performed with respect to the bone, implant and one piece superstructure, respectively. Implants are arbitrarily placed according to the anatomical limit of lower jaw and for the favorable distribution of occlusal force, which is applied at the end of cantilever extension of ISP with 30mm. Element type is tetrahedral for finite element model and the typical mechanical properties, Young's modulus and Poisson's ratio of each material, cortical, cancellous bone and implant material are utilized for the finite element analysis. From this study, we can see the distribution of equivalent stress equal to real situation and speculate the difference in the stress distribution in the whole model and at each implant fixture, From the analysis, the area of maximum stress is distributed on distal contact area between bone and fixture in the crestal bone. The maximum stress is 53MPa at the 0.2mm area from the bone-implant interface in the maximum side for 300N load condition for 4 fixture case, which is slightly less than the stress calculated from allowable strain. This stress has not been deduced to directly cause the loss of crestal bone around implant fixture, but the stress can be much reduced as the old peoples may have lower chewing force. Thus, clinical trial may be performed with this treatment protocol to use 4 fixtured ISP for old patients.

Evaluation of Sex and Age Factors Contributing to the Diagnosis of Oral Frailty in Community-Dwelling Older Adults

  • Eun-Ha Jung;Sun-Young Han
    • Journal of dental hygiene science
    • /
    • v.23 no.4
    • /
    • pp.378-388
    • /
    • 2023
  • Background: With increasing interest in health in old age, aspects of oral aging are being considered. The Korean Academy of Geriatric Dentistry recently proposed the diagnostic criteria for oral frailty in older adults in Korea. This study aimed to conduct a cross-sectional survey of factors related to oral frailty among community-dwelling older adults and identify differences in oral frailty status according to age and sex. Methods: Among 217 older adults aged ≥60 years who visited a senior center in Wonju, 206 completed all tests for oral frailty. Among them, data from those with a Korean Version of the Modified Barthel Index score ≥90 were used in the final analysis. After evaluating oral frailty diagnostic factors such as chewing ability, occlusal force, tongue pressure, oral dryness, oral cleanliness, and swallowing function, oral hypofunction was determined according to the oral frailty diagnostic criteria. Subsequently, the evaluation results were compared based on sex and age. Results: Significant differences in chewing ability, maximum occlusal pressure, and maximum tongue pressure were observed between sexes. However, these differences did not affect oral frailty diagnosis. All diagnostic factors of oral frailty, except for the risk of oral dryness and swallowing dysfunction, showed significant differences with age. However, no significant difference was observed in the prevalence of oral frailty. Additionally, this study found no relationship between sex and oral frailty factors using the oral frailty diagnostic criteria. However, it also found that age plays a significant role as an oral frailty diagnostic indicator, in addition to oral dryness and swallowing function. Conclusion: Sex and age did not affect oral frailty diagnosis. However, patients' chewing ability, occlusal force, and tongue pressure were affected by sex and age. Therefore, sex and age should be considered when diagnosing and intervening in oral frailty in the future.

Effect of Mouthguard on Tooth Distortion During Clenching (이악물기 시 발생되는 치아변형에 대한 구강보호장치의 역할)

  • Lee, Yun;Choi, Dae-Gyun;Kwon, Kung-Rock;Lee, Richard Sung-Bok;Noh, Kwan-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.405-417
    • /
    • 2010
  • Previous studies have already shown that mouthguard is effective in protecting jaw bone, teeth and oral tissue against sports trauma. However, other than severe trauma, repetitive force, such as disorders like clenching, cause teeth or oral tissue damage. These kinds of disorders usually present pathologic attrition in the posterior teeth, resorption in alveolar bone, loss of teeth and destruction of occlusion. Wearing a mouthguard is believed to be effective in preventing these disorders. But its effect is not examined thoroughly enough. The purpose of this study is to identify whether mouthguard is effective in reducing strain caused by clenching. Mandibular first molars in the normal occlusal relationship without any history of dental treatment were chosen. Biaxial type strain gauge was placed on the buccal surface of the tooth. Having maximum occlusal force, measured by load cell, as a standard, clenching intensity were divided into three stages; moment of slightly tooth contact, medium bite force (50% of maximum bite force), maximum bite force. Strain occurring in dentition in each stage with and without mouthguard was measured. Changes in strain (on dentition) between each stage and difference in strain, between with or without mouthguard were recorded by PCD-300 analyzer and PCD-30 soft ware. The data was statistically analyzed by Wilcoxon signed rank test. The following results were drawn; Without mouthguard, strain given on dentition increased as the clenching force increased. With mouthguard, strain given on dentition also increased as the clenching force increased. With mouthguard, strain decreased, in all cases of clenching force stages. Data on the moment of slightly tooth contact stage, had no statistical significance. However, with mouthguard, 50-90% of decrease in strain could be obtained in maximum occlusal force, compared to the group without mouthguard. Mouthguard decreased the strain on the dentition, caused by clenching. Therefore, mouthguard seems to be effective in preventing damage on dentition, by acting against clenching, which occurs both consciously and unconsciously during sports activities.

A STUDY ON THE STRESS DISTRIBUTION OF THE ALL CERAMIC CROWNS ACCORDING TO THE CUSP ANGLE OF THE MAXILLARY FIRST PREMOLAR USING THREE DIMENSIONAL FINITE ELEMENT METHOD (상악 제1소구치의 교두각에 따른 전부도재관의 응력분포에 관한 삼차원유한요소법적 연구)

  • Kim Won-Kyu;Shin Dong-Kuk;Song Kie-Bum;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.58-72
    • /
    • 2004
  • Statement of problem : Clinically, maxillary first premolar has a high risk of fracture. This is thought to be caused by the susceptible figure which the maxillary first premolar has In other words, sharp cusp angles of the premolar is thought to influence this situation. Purpose : This study was to know stress distribution of all-ceramic crown according to the cusp angle. Material and Method : It was manufactured a three dimensional finite element model simplified maxillary first premolar, and then analyzed stress distribution when cusp angle was each $80^{\circ}$, $90^{\circ}$, $100^{\circ}$, $110^{\circ}$ and $120^{\circ}$. Results and conclusion : 1. The von Misses stress showed that stress decreases as cusp angle increases in the central groove of the occlusal surface. 2. It showed that maximum principal stress was centered at the region of the central groove of the occlusal surface and a region which the force was inflicted. And also it appeared high on the lingual and buccal side of finish line. 3. The X axis of normal stress was focused in the central groove of the occlusal surface. The Y axis normal stress appeared high in the central groove of the occlusal surface, buccal and lingual side. 4. The Stress near the finish line showed a low value compared with stress in the region of the central groove of the occlusal surface. 5. It shows that the most dangerous angle for tooth fracture was on $80^{\circ}$ of the cusp angle and low on $120^{\circ}$ of its.

A FINITE ELEMENT ANALYSIS OF THE DISPLACEMENT AND STRESS DISTRIBUTION OF HUMAN DRY MANDIBLE DURING THE MANDIBULAR FIRST MOLAR CERVICAL TRACTION (유한요소법에 의한 하악제 1 대구치의 Cervical Traction의 효과에 관한 역학적 연구)

  • Ahn, Eui-Young;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.19 no.1 s.27
    • /
    • pp.45-59
    • /
    • 1989
  • This study was undertaken to analyze the displacement and stress distribution in the mandible according to the pulling directions during mandibular first molar cervical traction after mandibular second molar extraction. The 3-dimensional finite element method(FEM) was used for a mathematical model composed of 594 elements and 1019 nodes. An orthodontic force, 450 gm, was applied to the each mandibular first molar in parallel, and below the occlusal plane by $7^{\circ}\;and\;25^{\circ}$ and meet the midsagittal plane by $40^{\circ}$ toward posterior direction. The results were as follows: 1. Mandibular teeth were displaced in more downward, posterior and lateral direction. Especially high stress was noted in case of parallel pull than in case of below the occlusal plane by $7^{\circ}\;and\;25^{\circ}$. 2. Mandibular first molar was moved bodily. 3. Generally, alveolar bone, mandibular body, ascending ramus and mandibular angle portion were displaced in downward, posterior and lateral direction. But coronoid process was displaced in downward, forward and lateral direction, and anterior and inner middle portion of condyle head and neck were displaced in downward, forward and medial direction, and posterior and outer middle portion of condyle head and neck were displaced in upward, forward and medial direction. 4. Maximum stress was observed at the condyle head and neck portion. With steeper direction of force, condyle head and neck showed more stress than parallel relation to the occlusal plane.

  • PDF