• Title/Summary/Keyword: Maximum flow

Search Result 3,385, Processing Time 0.029 seconds

Development of a Flow Rate Sensor Using 2-way Cartridge Valve (2-유로 카트리지 밸브를 이용한 유압용 유량 센서의 개발)

  • 홍예선;이정오
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2381-2389
    • /
    • 1993
  • In this paper the design and test results of a dynamic flow rate sensor was reported. This sensor comprises an 2-way cartridge valve as standard hydraulic component and a displacement sensor. Its working principle bases on the linear relationship between the flow rate and the piston displacement of 2-way cartridge valves under constant pressure drop. This principle is well known, however it is not easy to develop a flow rate sensor with the measurement range of 300 1/min, pressure loss of less than 8 bar at 300 1/min, maximum linearity error of less than $\pm$1% and the maximum rising time of 10 ms. This paper describes the design procedure of the flow rate sensor, the improvement procedure of static performance and test method and results of dynamic performance.

Investigation of the 2013 Hadari Debris Flow in Korea Through Field Survey and Numerical Analysis

  • Choi, Junghae
    • The Journal of Engineering Geology
    • /
    • v.28 no.3
    • /
    • pp.341-348
    • /
    • 2018
  • Landslides can be caused by localized intense rainfall. The loss of human lives and damage to property from landslides is increasing. However, little information exists on the movement and flow of sediment material at the time of rapid landslides. In this study, a field survey was conducted of landslides that occurred in 2013 in the Hadari area of Yeoju city in Korea. This was followed by numerical analysis. The purpose is to analyze the characteristics of a consequent debris flow and its movement at the time of failure. The results of the field survey and numerical analysis are consistent with each other. The maximum velocity of the debris flow was ~9.335 m/s and the maximum sediment thickness ~4.674 m. The latter is similar to the traces of debris flow observed in the field.

A Study on the Method for Mitigation of Streaming Electrifiction by the Improvement of Flow Condition in the Oil Folw System of Transformer (변압기 절연유의 순환 계통에서의 흐름 조건의 개선에 의한 유동대전현사의 완화 방법에 관한 연구)

  • 권석두;남상천
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.4
    • /
    • pp.594-600
    • /
    • 1994
  • The maximum charge accumulation in transformers caused by streaming electrification is commonly observed on the bottom area of transformer winding(i.e.the oil inlet of transformer winding). It is because turbulent flows occur in this portion of transformers. Consequently, if we are to reduce the maximum charge accumulation of transformers, it is important that we should have a good understanding of the conditions of the occurence of partial turbulent flows in the oil inlet of transformer winding. With this point in mind, a simple flow model was designed in this study in order to simulate oil flow in the insulation ducts of power transformers. As a method for mitigating charge accummulation, attention was given to (a) a flow path design for the improvement of flow conditions, and (b) the charge tendency of the material used this design. The results of this study show that the above method is useful for mitigating charge accumulation.

  • PDF

Flow Analysis on the Outside of Automotive Body (차체 외부에서의 유동해석)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.1
    • /
    • pp.55-60
    • /
    • 2010
  • The air resistance about automotive body is studied by the flow analysis in this study. Maximum air flow velocity is shown with 28 to 30 m/s on the upper roof of automotive body. The air flow becomes most regular at automotive body model 3 but the model of 2 or 3 becomes irregular in comparison with the model 1. The maximum air resistance pressure is shown with 413 to 420 Pa at the front bumper of automotive body. The flow velocity at inlet or middle plane of automotive body is shown as the contour same with the model of 1, 2, or 3. But the velocity at outlet plane at model 1 is shown as the contour different with the model of 2 or 3.

A Study on the Heuristic Algorithm for n/m Flow- Shop Problem (n/m 흐름작업의 Heuristic 기법에 관한 연구)

  • 이근부
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.5 no.6
    • /
    • pp.41-48
    • /
    • 1982
  • This paper analyzed md developed flow - shop sequencing heuristic method. The essence of the heuristic approach is in the application of selective routine that reduce the size of a problem. The advantages of this approach are consistency. Speed, endurance and the ability to cope with more data and larger systems than is humanly possible, In recent years many heuristic procedures have been suggested for the flow - shop sequencing problem. Although limited comparisons of these procedures have been made, a full scale test and evaluation have not been reported previously. The maximum flow - time criterion is selected as the evaluation criterion is selected as the evaluation criterion of flow - shop's efficiency. The author evaluated these 3 heuristic method's performance. By the evaluation of the result, we can see that the modified methods produce a shorter maximum flow - time than the original methods.

  • PDF

Effect of the Flow Rate of Coolant on the Absorption Peformance of a Vertical Absorber (수직 액막형 흡수기의 흡수성능 변화에 미치는 냉각수 유량의 영향)

  • Kim Jung-Kuk;Cho Keum-Nam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.5
    • /
    • pp.410-417
    • /
    • 2006
  • The present study predicted the effect of the flow rate of coolant on the absorption performance of a vertical falling film type absorber Heat and mass transfer peformances were numerically investigated. The exit temperatures of solution and coolant were decreased as the flow rate of the coolant was increased at the film Reynolds number of 100. The absorption mass flux was increased and then decreased as the distance from the inlet of the absorber was increased. The distance showing the maximum absorption mass flux was ranged from 0.3 to 0.5m. The heat flux and the absorption mass flux were increased and then slowly decreased as the flow rate of the coolant was increased. The maximum values were obtained at the flow rate of coolant of 2.0L/min.

Analysis of Debris Flow of Chun-cheon Landslide Area using Numerical Methods (수치해석을 통한 춘천 산사태지역 토석류 거동 분석)

  • Choi, Junghae
    • The Journal of Engineering Geology
    • /
    • v.27 no.1
    • /
    • pp.59-66
    • /
    • 2017
  • The characteristic of recent rainfall pattern in Korea is concentrated in summer season and it is very different compare with former characteristic. In 2011, there was heavy rainfall in Chuncheon city of northern part of Korea. Because of rainfall in short time, many landslides were occurred in narrow area and many people were killed by these landslides at that time. The purpose of this study is to calculate run-out distance of debris flow and analyze the movement properties of debris flow according to the elapsed time using numerical analysis method at that time. The debris 2D program, which is developed by prof. Liu in National Taiwan University, was used in this study. Run-out distance of debris flow was calculated under different yield strength conditions which were controlled by rainfall amount. The results reveal that absolute maximum velocity of the debris flow is about 8.1 m/s and maximum depth of debris flow is about 7 m when debris flow was occurred. The run-out distance after 500 sec is about 300 m from end of the valley. It is very well similar with actual debris flow run-out distance. From these results, we can presume the maximum velocity and depth of debris flow at that time.

An Experimental Study on the Flow-rate and Velocity Profile of Air Flow in the Smooth Pipe (매끈한 관내 공기유동에서 유량과 속도분포에 관한 실험적 연구)

  • Park, Sang-Eun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.5 no.4 s.17
    • /
    • pp.54-60
    • /
    • 2002
  • Experimental study was conducted to obtain the air velocity profiles in turbulent pipe flow. The acrylic smooth pipe (${\phi}=80mm$) was used for the test section of the flow loop. It was known that the velocity profiles of turbulent flow were different with Reynolds numbers and the viscous sublayer was usually quite thin. The following conclusions were drawn from the experimental investigations. Maximum velocity of the pipe center and flow-rate are useful for the duct design on the spot. The velocity profiles of high Reynolds number was flatter than those of low Reynolds number. It was known that the exponent, n, for power-law velocity profiles was $6{\sim}9$ depending on Reynolds number ranging from $10^4$ to $10^5$ in the turbulent flow, However, in this experiment study, it was $9{\sim}14$ depending on Reynolds number ranging from 17,000 to 123,727 in the turbulent flow, and $1.7{\sim}3.5$ depending on Reynolds number ranging from 2,442 to 4,564 in the transition region.

Observation of Reservoir Current Using Drifter (The Case Study of Yongdam Reservoir) (Drifter를 이용한 저수지 수리거동 조사 (용담댐을 중심으로))

  • Lee, Yo-Sang;Koh, Deok-Koo;Chae, Hyo-Sok;Han, Kyung-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.2
    • /
    • pp.200-209
    • /
    • 2012
  • The current of the water body is very important information for the water quality management on reservoirs. It is applied to hydraulics and water quality model for simulation. In this regard, the current characteristic of water body is the basic information that can be used to predict various conditions. However, it is very slow flowing and is affected by the reservoir operations and external factors. As such, an accurate measurement of the current is a difficult problem. In order to measure the water current, we constructed a drifter. According to the result of flow survey at Yongdam reservoir, 5m and 10 m depth layer flow was investigated from the upstream to the downstream, during a flood period. Maximum flow rate of 5 m depth is 13.8 cm $sec^{-1}$ and 10 m depth shows 4 cm $sec^{-1}$, respectively. But 2m depth shows a backward flow and maximum flow rate is 4 cm $sec^{-1}$. Density currents flow plays the role of back flow in reservoirs. Flow velocity in the reservoir was measured in the range of 1~2 cm $sec^{-1}$, at normal flow season, and the flow direction were different for each survey. This phenomenon occurs because the reservoir volume is very large, compared to the inflow and outflow volume.

Inundation Simulation of Underground Space using Critical Dry Depth Scheme (임계 마름 수심기법을 이용한 지하공간 침수 모의)

  • Rhee, Dong Sop;Kim, Hyung-Jun;Song, Chang Geun
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.63-69
    • /
    • 2015
  • In this study, a 2D hydrodynamic model equipped with critical dry depth scheme was developed to reproduce the flow over staircase. The channel geometry of hydraulic experiment conducted by Ishigaki et al. was generated in the computational space, and the developed model was validated against flow properties such as discharge, velocity and momentum. In addition, the water surface profile and the velocity distribution evolved in flow over two layers staircases were analyzed. When the initial water depth at the upper floor was 0.3 m, the maximum velocity at lower floor was 4.2 m/s, and the maximum momentum was $1.2m^3/s^2$, and its conversion to force per unit width was 1.2 kN/m. This value was equivalent to the hydrostatic force with 50 cm water depth, and evacuation became difficult, as proposed by Ishigaki et al. For the flow over staircases connecting two layers, the maximum run-up height in flat part connecting two layers was approximately two times higher than the initial water depth in upper floor, and the rapid shock wave with sharp front and long tail was propagated.