• 제목/요약/키워드: Maximum flow

검색결과 3,392건 처리시간 0.037초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

자율 주행을 위한 Edge to Edge 모델 및 지연 성능 평가 (Edge to Edge Model and Delay Performance Evaluation for Autonomous Driving)

  • 조문기;배경율
    • 지능정보연구
    • /
    • 제27권1호
    • /
    • pp.191-207
    • /
    • 2021
  • 오늘날 이동통신은 급증하는 데이터 수요에 대응하기 위해서 주로 속도 향상에 초점을 맞추어 발전해 왔다. 그리고 5G 시대가 시작되면서 IoT, V2X, 로봇, 인공지능, 증강 가상현실, 스마트시티 등을 비롯하여 다양한 서비스를 고객들에게 제공하기위한 노력들이 진행되고 있고 이는 우리의 삶의 터전과 산업 전반에 대한 환경을 바꿀 것으로 예상되고 되고 있다. 이러한 서비스를 제공하기위해서 고속 데이터 속도 외에도, 실시간 서비스를 위한 지연 감소 그리고 신뢰도 등이 매우 중요한데 5G에서는 최대 속도 20Gbps, 지연 1ms, 연결 기기 106/㎢를 제공함으로써 서비스 제공할 수 있는 기반을 마련하였다. 하지만 5G는 고주파 대역인 3.5Ghz, 28Ghz의 높은 주파수를 사용함으로써 높은 직진성의 빠른 속도를 제공할 수 있으나, 짧은 파장을 가지고 있어 도달할 수 있는 거리가 짧고, 회절 각도가 작아서 건물 등을 투과하지 못해 실내 이용에서 제약이 따른다. 따라서 기존의 통신망으로 이러한 제약을 벗어나기가 어렵고, 기반 구조인 중앙 집중식 SDN 또한 많은 노드와의 통신으로 인해 처리 능력에 과도한 부하가 발생하기 때문에 지연에 민감한 서비스 제공에 어려움이 있다. 그래서 자율 주행 중 긴급 상황이 발생할 경우 사용 가능한 지연 관련 트리 구조의 제어 기능이 필요하다. 이러한 시나리오에서 차량 내 정보를 처리하는 네트워크 아키텍처는 지연의 주요 변수이다. 일반적인 중앙 집중 구조의 SDN에서는 원하는 지연 수준을 충족하기가 어렵기 때문에 정보 처리를 위한 SDN의 최적 크기에 대한 연구가 이루어져야 한다. 그러므로 SDN이 일정 규모로 분리하여 새로운 형태의 망을 구성 해야하며 이러한 새로운 형태의 망 구조는 동적으로 변하는 트래픽에 효율적으로 대응하고 높은 품질의 유연성 있는 서비스를 제공할 수 있다. 이러한 SDN 구조 망에서 정보의 변경 주기, RTD(Round Trip Delay), SDN의 데이터 처리 시간은 지연과 매우 밀접한 상관관계를 가진다. 이 중 RDT는 속도는 충분하고 지연은 1ms 이하이기에 유의미한 영향을 주는 요인은 아니지만 정보 변경 주기와 SDN의 데이터 처리 시간은 지연에 크게 영향을 주는 요인이다. 특히, 5G의 다양한 응용분야 중에서 지연과 신뢰도가 가장 중요한 분야인 지능형 교통 시스템과 연계된 자율주행 환경의 응급상황에서는 정보 전송은 매우 짧은 시간 안에 전송 및 처리돼야 하는 상황이기때문에 지연이라는 요인이 매우 민감하게 작용하는 조건의 대표적인 사례라고 볼 수 있다. 본 논문에서는 자율 주행 시 응급상황에서 SDN 아키텍처를 연구하고, 정보 흐름(셀 반경, 차량의 속도 및 SDN의 데이터 처리 시간의 변화)에 따라 차량이 관련정보를 요청해야 할 셀 계층과의 상관관계에 대하여 시뮬레이션을 통하여 분석을 진행하였다.

시멘트 분산제(分産劑) 및 고류동화제(高流動化劑)를 사용(使用)한 모르터의 제(諸) 성질(性質)에 관(關)한 실험적(實驗的) 연구(硏究) (Experimental studies on the characteristics of the mortar using dispersing agent of cement and high fluid admxiture)

  • 김성완;박인규
    • 농업과학연구
    • /
    • 제11권1호
    • /
    • pp.146-159
    • /
    • 1984
  • 본(本) 연구(硏究)는 시멘트 분산제(分散劑) 및 고유동화제(高流動化劑)를 사용(使用)하여 모르터의 압축(壓縮) 및 인장강도(引張强度)와 감소율(減少率), 흐름시험(試驗)을 실시(實施)하였으며 그 결과(結果)를 요약(要約)하면 다음과 같다. 1. 최대강도(最大强度)를 나타내는 이화제(泥和劑)의 최적(最適) 첨가율(添加率)은 배합별(配合別) 공(共)히 같은 경향(傾向)으로 고유동화제(高流動化劑) SP는 0.6%이고 분산제(分散劑) LG와 C211은 0.2%, SK는 0.3%, C376은 0.5%로 나타났다. 그런데 사용적량(使用適量)의 2~3배(倍) 과다(過多) 사용시(使用時)는 강도(强度)가 급격(急激)히 저하(低下)하는데 이것은 수화작용(水和作用)에 악영향(惡影響)을 일으켜 응결(凝結)이 상당히 지연(遲延)되는 것으로 본다. 2. 적정량(適定量)의 이화제(泥和劑)를 첨가(添加)하였을 때 압축강도(壓縮强度)는 보통(普通)모르터 보다 재령(材令) 7일(日)에서 고유동화제(高流動化劑) SP는 40.7%, 분산제(分散劑)(C211은 19.5%, LG은 19.1%, SK는 18.1%, C376은 17.9%)의 평균(平均) 증가율(增加率)은 18.7%이었으며, 재령(材令)28일(日)에서는 고유동화제(高流動化劑) SP가 24.4%, 분산제(分散劑)(LG은 21.2%, C211은 16.4%, SK는 11.1%, C376은 7.6%)의 평균(平均) 증가율(增加率)은 14.1%로 나타냈다. 3. 적정량(適定量)의 이화제(泥和劑)를 첨가(添加)하였을 때 인장강도(引張强度)는 보통(普通)모르터 보다 재령(材令)7일(日)에서 고유동화제(高流動化劑) SP가 26.6%, 분산제(分散劑)(SK는 16.0%, C376은 14.7%, LG은 10.0%, C211은 5.8%)의 평균(平均) 증가율(增加率)은 11.6%이었다. 재령(材令)28일(日)에서는 고유동화제(高流動化劑) SP는 16.5%, 분산제(分散劑)(LG는 19.1%, SK는 10.6%, C211은 10.1%, C376은 8.7%)의 평균(平均) 증가율(增加率)은 12.1% 이었다. 4. 각각(各各)의 이화제(泥和劑)를 적량(適量) 첨가(添加)했을 때 모르터의 감수율(減水率)은 콘크리트의 감수율(減水率) 보다 작게 나온다. 즉 콘크리트의 감수율(減水率)은 15% 정도(程度) 감수(減水)했다고 했으나 모르터의 감수율(減水率)은 1 : 1의 경우는 최소(最少) 5.8%에서 최대(最大) 13.1%였고, 1 : 2의 경우는 최소(最小) 7.6%에서 최대(最大) 14.2%였으며, 1 : 3의 경우는 최소(最小) 9.5%에서 최대(最大) 18.8%의 범위(範圍)에 있었다. 5. 각(各) 이화제(泥和劑)의 유동성(流動性)은 고유동화제(高流動化劑) SP가 다른 분산제(分散劑) 보다 월등히 좋았다. 즉 1 : 1의 경우 w/c가 30%에서 280(75% 증가(增加)), 1 : 2의 경우는 w/c 가 36%에서 147(23.5% 증가(增加))로 가장 좋았으며, 1 : 3의 경우에서는 다른 분산제(分散劑)와 같은 경향(傾向)을 보였다. 그러므로 이러한 양질(良質)의 분산제(分散劑)는 프리팩트 콘크리트 공사(工事)에 사용(使用)하는 주입전충용(注入塡充用) 모르터에 적합(適合)한 것으로 사료(思料)된다.

  • PDF

수영만 수질에 미치는 비점원 오염부하의 특성과 영향 (The Characteristics and the Effects of Pollutant Loadings from Nonpoint Sources on Water Quality in Suyeong Bay)

  • 조은일;이석모;박청길
    • 한국수산과학회지
    • /
    • 제28권3호
    • /
    • pp.279-293
    • /
    • 1995
  • 강우시 유출되는 비점원오염물질의 유출특성을 조사하고, 수영만에 있어서 하천오염물질이 만내로 유입되어 미치는 영향을 4가지 경우인 점원오염부하가 미치는 영향(Case 1), 연간 비점원오염부하가 미치는 영향(Case 2), 우기시 오염부하가 미치는 영향(Case 3)과 실측강우 조사기간동안 비점원오염부하가 미치는 영향(Case 4)으로 나누어 예측 및 평가하였다. 이상의 연구 결과를 요약하면 다음과 같다. 비점원오염물질의 특성을 보면 강우시 하천의 수질변동은 강우강도와 유량의 증감과 매우 밀접한 관계를 가지고 증감한다 COD, TSS와 VSS의 경우는 2차 강우 후 유량이 최대인 $65.736m^3/s$가 될 때 오염물질의 최대치가 나타났는데 최대치는 각각 121.4mg/l, 1148.0mg/l와 262.0mg/l를 보여주었다. 그리고 영양염류인 경우는 1차 강우가 시작되어 유량이 1차 최대치인 $4.686m^3/s$로 증가할 패 최대치를 보여주는데 $TIN,\;NH_4\;^+-\;N,\;NO_2\;^--N$$PO_4\;^{3-}-P)$는 각각 20.306mg/l, 14.154mg/l, 9.571mg/l와 1.785mg/l를 나타내며 2차 강우가 시작된 후 약간 증가하다가 감소하였다. 해수유동모델에 의한 결과를 보면 만내 유향은 낙조시에 시계방향으로 창조시에 반시계방향으로 북동-남서방향이다. 만내 조류속은 최대 0.3m/s이고 만외 유속은 0.4m/s 정도이며 계산치는 관측치와 매우 유사하게 재현되고 있다. 확산모델의 보정은 점원오염부하량이 만내에 미치는 영향을 수영만내 관측치를 이용해 반복 시뮬레이션하여 보정하였고 보정결과 COD, SS의 계산 결과는 관측치와 잘 일치하였다. 확산모델의 적용결과 수영강의 오염부하는 낙조시에는 해운대 해수욕장으로 창조시는 광안리 해수욕장으로 수질을 악화시켰다. 비점원오염부하가 만내에 미치는 영향을 재현시킨 결과 연간 강우로 인한 비점원오염부하(Case 2)와 우기시 강우로 인한 오염부하(Case 3)가 미치는 영향은 점원오염부하(Case 1)가 만내 수질이 미치는 영향과 비교해 광안리 해수욕장의 오염부하를 약간 증가시키며 큰 차이는 보이지 않았다. 강우 조사시 비점원오염부하가 미치는 영향(Case 4)은 수영만내에 매우 심각한 오염현상을 보여준다. 낙조시에는 COD와 SS의 만내의 농도 분포는 각각 2.0-30.0mg/l와 7.0-200.0mg/l를 보여준다. 낙조시에는 창조시보다 낮은 오염정도를 나타내나 해운대 해수욕장으로는 높은 오염을 가중시키는 것을 볼 수 있다. 그러나 강우가 멈춘 후 24시간이 경과하여 실측한 수영만의 오염분포를 보면 건기시 해역농도에 비해 약간 높은 농도분포를 보여 주는 것으로 보아 입자가 큰 침강성 고형물질의 빠른 침강과 수영만내 해수유동으로 인해 빠르게 확산되어 농도가 감소되는 것으로 보인다. 그러나 강우가 시작한 후 매우 높은 오염물질을 함유하는 강우유출수가 만내로 유입될 때의 충격부하는 수영만의 해양생태계에 심각한 영향을 미치리라 예상되며 만약 이들 강우유출수를 처리하여 만내로 유출시키면 만내 수질은 개선되리라 사료된다.

  • PDF

인공광 스마트온실에서 광질 및 광강도 제어가 케일 실생묘의 생장에 미치는 영향 (Growth of Kale Seedlings Affected by the Control of Light Quality and Intensity under Smart Greenhouse Conditions with Artificial Lights)

  • 허정욱;이재수;이공인;김현환
    • 한국환경농학회지
    • /
    • 제36권3호
    • /
    • pp.193-200
    • /
    • 2017
  • 인공광 스마트온실(식물공장) 조건에서 작물의 생장은 주로 외부 환경조건의 변화와 상관없이 형광등이나 특정 파장역의 발광다이오드와 같은 인공광원에 의해 좌우된다. 본 실험에서는 형광등 및 발광다이오드를 활용한 광질 및 광강도 제어가 케일 실생묘의 생장 및 물질합성에 미치는 영향을 조사하였다. 잎이 3~4매 전개한 케일 실생묘는 광강도를 50 및 $100{\mu}mol/m^2/s$로 제어한 형광등 (FLL 및 FLH구), 적색 LEDs (RL 및 RH 구), 청색+백색 LEDs (BWL 및 BWH구) 및 청색+적색 LEDs (BRL 및 BRH구) 등 단일 및 혼합광질로 제어하였으며 50일간 담액방식으로 수경재배하였다. 케일 지상부 생체중은 광강도 $100{\mu}mol/m^2/s$의 적색, 청색+ 백색 및 청색+적색의 혼합광 조사구에서 유의하게 증가하였으며, 신초신장은 광강도가 높은 처리구에서 억제되었고 잎내 폴리페놀 함량은 증가하였다. 당합성은 광강도 $50{\mu}mol/m^2/s$에 비해 $100{\mu}mol/m^2/s$ 조건의 적색광질에 의해 2배이상 증가하였다. 본 실험을 통하여 인공광 스마트온실 조건에서 특정 파장역의 광질 및 광강도를 제어하면서 작물을 수경재배하는 것은 노지나 온실에서 토경재배하는 관행적 재배방식에 비해 작업효율성을 높이면서 잎의 생장 및 물질합성을 촉진할 수 있다는 것을 알 수 있었다. 금후, 인공광 스마트온실에서 특정 파장역의 LEDs를 인공광원으로 할 때 작물생장을 최대로 유지할 수 있는 적정 광강도에 대한 연구를 수행할 계획이다.

국민건강보험 발전방향 (Future Direction of National Health Insurance)

  • 박은철
    • 보건행정학회지
    • /
    • 제27권4호
    • /
    • pp.273-275
    • /
    • 2017
  • It has been forty years since the implementation of National Health Insurance (NHI) in South Korea. Following the 1977 legislature mandating medical insurance for employees and dependents in firms with more than 500 employees, South Korea expanded its health insurance to urban residents in 1989. Resultantly, total expenses of the National Health Insurance Service (NHIS) have greatly increased from 4.5 billion won in 1977 to 50.89 trillion won in 2016. With multiple insurers merging into the NHI system in 2000, a single-payer healthcare system emerged, along with separation policy of prescribing and dispensing. Following such reform, an emerging financial crisis required injections from the National Health Promotion Fund. Forty years following the introduction of the NHI system, both praise and criticism have been drawn. In just 12 years, the NHI achieved the fastest health population coverage in the world. Current medical expenditure is not high relative to the rest of the Organization for Economic Cooperation and Development. The quality of acute care in Korea is one of the best in the world. There is no sign of delayed diagnosis and/or treatment for most diseases. However, the NHI has been under-insured, requiring high-levels of out-of-pocket money from patients and often causing catastrophic medical expenses. Furthermore, the current environmental circumstances of the NHI are threatening its sustainability. Low birth rate decline, as well as slow economic growth, will make sustainment of the current healthcare system difficult in the near future. An aging population will increase the amount of medical expenditure required, especially with the baby-boomer generation of those born between 1955 and 1965. Meanwhile, there is always the problem of unification for the Korean Peninsula, and what role the health insurance system will have to play when it occurs. In the presidential election, health insurance is a main issue; however, there is greater focus on expansion and expenditure than revenue. Many aspects of Korea's NHI system (1977) were modeled after the German (1883) and Japanese (1922) systems. Such systems were created during an era where infections disease control was most urgent and thus, in the current non-communicable disease (NCD) era, must be redesigned. The Korean system, which is already forty years old, must be redesigned completely. Although health insurance benefit expansion is necessary, financial measures, as well as moral hazard control measures, must also be considered. Ultimately, there are three aspects that we must consider when attempting redesign of the system. First, the health security system must be reformed. NHI and Medical Aid must be amalgamated into one system for increased effectiveness and efficiency of the system. Within the single insurer system of the NHI must be an internal market for maximum efficiency. The NHIS must be separated into regions so that regional organizers have greater responsibility over their actions. Although insurance must continue to be imposed nationally, risk-adjustment must be distributed regionally and assessed by different regional systems. Second, as a solution for the decreasing flow of insurance revenue, low premium level must be increased to an appropriate level. Likewise, the national reserve fund (No. 36, National Health Insurance Act) must be enlarged for re-unification preparation. Third, there must be revolutionary reform of benefit package. The current system built a focus on communicable diseases which is inappropriate in this NCD era. Medical benefits must not be one-time events but provide chronic disease management. Chronic care models, accountable care organization, patient-centered medical homes, and other systems that introduce various benefit packages for beneficiaries must be implemented. The reimbursement system of medical costs should be introduced to various systems for different types of care, as is the case with part C (Medicare Advantage Program) of America's Medicare system that substitutes part A and part B. Pay for performance must be expanded so that there is not only improvement in quality of care but also medical costs. Moreover, beneficiaries of the NHI system must be aware of the amount of their expenditure through a deductible payment system so that spending can be profiled and monitored. The Moon Jae-in Government has announced its plans to expand the NHI system; however, it is important that a discussion forum is created so that more accurate analysis of the NHI, its environments, and current status of health care system, can take place for reforming NHI.

개방형과 무창형 육성비육돈사의 환기효율 비교 (Comparison of Ventilation Efficiency in an Enclosed and Conventional Growing-Finishing Pig House)

  • 송준익;최동윤;정종원;양창범;최홍림
    • Journal of Animal Science and Technology
    • /
    • 제46권3호
    • /
    • pp.459-468
    • /
    • 2004
  • 본 연구는 우리 나라에 건축되어져 있는 개방육성비육돈사와 무창육성비육돈사의 환경효율을 검증하고자 하였다. 본 실험은 실험돈사에서 겨울철과 여름철로 나누어 실시한 실험결과는 다음과 같다. 1) 무창육성비육돈사는 외부의 기온 변화가 심하더라도 돈사내부의 온도는 외부기온의 영향을 받지 않고 여름철 24.8${\sim}$29.1$^{\circ}C$, 겨울철 17.9${\sim}$23.1$^{\circ}C$를 유지하였으나 개방육성비육돈사는 여름철 24.7${\sim}$32.3$^{\circ}C$, 겨울철 14.5${\sim}$18.2$^{\circ}C$를 유지하여 온도효율이 낮았다. 2) 암모니아 농도를 측정한 바 개방육성비육돈사는 여름철 9.31${\sim}$16.9 mg/$\ell$, 겨울철 5.1${\sim}$19.7 mg/$\ell$로 측정되었으며, 무창육성비육돈사는 공기입기 및 배기의 효율적인 구성으로 여름철 7.9${\sim}$16.1 mg/$\ell$, 겨울철 3.7${\sim}$9.6 mg/$\ell$를 유지하여 개방육성비육돈사 보다는 낮게 나타났다. 3) 무창육성비육돈사는 돼지생육 공간(하부)의 공기유속이 겨울철 최소환기(5%) 수준으로 하였을 때 0.0${\sim}$0.87 m/s 였으며, 여름철 최대환기(95%) 수준에서는 0.1${\sim}$2.73 m/s로 분포되어 여름철 및 겨울철의 무창육성비육돈사내 공기유속이 개방육성비육돈사보다 양호하였다. 4) 여름철 비육돈출하시(평균 110 kg 전후)의 체중은 개방육성비육돈사는 100.2인데 비하여 무창육성비육돈사에서의 체중은 107.3kg으로 약 7kg 정도의 차이로 빠른 증체를 가져왔는데, 이것은 외기의 영향을 영향을 크게 받지 않고 일정한 환경을 유지해 주어 스트레스를 줄여 주었기 때문으로 판단된다.

온실의 잉여 태양에너지 회수용 FCU 소요대수 검토 (Estimation of the Required Number of Fan Coil Unit for Surplus Solar Energy Recovery of Greenhouse)

  • 윤성욱;최만권;김하늘;강동현;이시영;손진관;윤용철
    • 생물환경조절학회지
    • /
    • 제25권2호
    • /
    • pp.83-88
    • /
    • 2016
  • 본 연구에서는 이미 보고된 잉여 태양에너지 관련 연구결과와 현재 현장에 설치되어 있는 냉난방용 FCU 현황을 개략적으로 검토한 후, 잉여 태양에너지 회수에 필요한 FCU의 소요대수 결정 방법을 개략적으로 제시하여 앞으로 이 분야의 연구자 및 기술자들에게 기조자료를 제시할 목적으로 연구를 수행하였다. 실험기간 동안 최대, 평균 및 최저 외기온은 각각 $28.2^{\circ}C$, $4.4^{\circ}C$$-11.5^{\circ}C$정도였다. 온실 밖의 수평면 일사량은 $0.8{\sim}20.5MJ{\cdot}m^{-2}$로 정도의 범위였으며, 평균 및 총 일사량은 $10.8MJ{\cdot}m^{-2}$$1,187.5MJ{\cdot}m^{-2}$으로 나타났다. 그리고 주간동안 온실 내의 평균기온과 상대습도는 각각 18.8~45.5 및 53.5~77.5%정도였다. 실험기간 동안 온실로부터 회수한 총 잉여 태양에너지는 6,613.4MJ정도로서 총 난방에너지인 98,600.2MJ 약 6.7%정도를 보충할 수 있을 것으로 나타났다. 또한 사양이 유사한 FCU를 사용하지만, 난방을 위하여 설치되는 FCU의 대수는 제각각 다른 것을 알 수 있었고, 좀 더 효율적이고 경제적인 관점에서 설치높이, 방향 및 설치간격, 적정 대수에 대한 연구가 이루어져야 할 것으로 판단된다. 잉여 태양에너지 회수용 FCU의 적정 소요 대수는 FCU를 통과하는 공기의 질량 및 순환유량을 기준으로 각각 8.4~10.9대 및 6.1~8.0대 정도이었다. 여기에 계산방법이나 FCU의 효율 및 사용 환경 등 위험률을 고려하면, 결국 9대 전후(약 $24m^3$당 1대 정도)를 설치하면 될 것으로 판단되었다.

개선된 배깅 앙상블을 활용한 기업부도예측 (Bankruptcy prediction using an improved bagging ensemble)

  • 민성환
    • 지능정보연구
    • /
    • 제20권4호
    • /
    • pp.121-139
    • /
    • 2014
  • 기업의 부도 예측은 재무 및 회계 분야에서 매우 중요한 연구 주제이다. 기업의 부도로 인해 발생하는 비용이 매우 크기 때문에 부도 예측의 정확성은 금융기관으로서는 매우 중요한 일이다. 최근에는 여러 개의 모형을 결합하는 앙상블 모형을 부도 예측에 적용해 보려는 연구가 큰 관심을 끌고 있다. 앙상블 모형은 개별 모형보다 더 좋은 성과를 내기 위해 여러 개의 분류기를 결합하는 것이다. 이와 같은 앙상블 분류기는 분류기의 일반화 성능을 개선하는 데 매우 유용한 것으로 알려져 있다. 본 논문은 부도 예측 모형의 성과 개선에 관한 연구이다. 이를 위해 사례 선택(Instance Selection)을 활용한 배깅(Bagging) 모형을 제안하였다. 사례 선택은 원 데이터에서 가장 대표성 있고 관련성 높은 데이터를 선택하고 예측 모형에 악영향을 줄 수 있는 불필요한 데이터를 제거하는 것으로 이를 통해 예측 성과 개선도 기대할 수 있다. 배깅은 학습데이터에 변화를 줌으로써 기저 분류기들을 다양화시키는 앙상블 기법으로 단순하면서도 성과가 매우 좋은 것으로 알려져 있다. 사례 선택과 배깅은 각각 모형의 성과를 개선시킬 수 있는 잠재력이 있지만 이들 두 기법의 결합에 관한 연구는 아직까지 없는 것이 현실이다. 본 연구에서는 부도 예측 모형의 성과를 개선하기 위해 사례 선택과 배깅을 연결하는 새로운 모형을 제안하였다. 최적의 사례 선택을 위해 유전자 알고리즘이 사용되었으며, 이를 통해 최적의 사례 선택 조합을 찾고 이 결과를 배깅 앙상블 모형에 전달하여 새로운 형태의 배깅 앙상블 모형을 구성하게 된다. 본 연구에서 제안한 새로운 앙상블 모형의 성과를 검증하기 위해 ROC 커브, AUC, 예측정확도 등과 같은 성과지표를 사용해 다양한 모형과 비교 분석해 보았다. 실제 기업데이터를 사용해 실험한 결과 본 논문에서 제안한 새로운 형태의 모형이 가장 좋은 성과를 보임을 알 수 있었다.