• 제목/요약/키워드: Maximum detection range

검색결과 206건 처리시간 0.029초

AIS 광역망을 이용한 연근해 어장관리 (Management of coastal and offshore fishing ground using wide-area network of AIS)

  • 신형일;배문기;이대재;이유원
    • 수산해양기술연구
    • /
    • 제42권3호
    • /
    • pp.179-185
    • /
    • 2006
  • In order to efficiently manage the coastal and offshore fishing ground, the applicability of real-time monitering was also investigated through a wide-area network of automatic identification system(AIS). The experiment of efficiently managing coastal and offshore fishing ground with a wide-area network of AIS required, on the headquarter's screen, a synthetic display of vessel information transmitted from three different distant stations. This experiment tested the applicability of real-time monitoring with the shown display. The maximum range of detection of the first station in Busan was 24 nautical miles while those of the second and third stations in Yeosu and Jeju were 26 and 52 nautical miles, respectively.

Semiautomated Analysis of Data from an Imaging Sonar for Fish Counting, Sizing, and Tracking in a Post-Processing Application

  • Kang, Myoung-Hee
    • Fisheries and Aquatic Sciences
    • /
    • 제14권3호
    • /
    • pp.218-225
    • /
    • 2011
  • Dual frequency identification sonar (DIDSON) is an imaging sonar that has been used for numerous fisheries investigations in a diverse range of freshwater and marine environments. The main purpose of DIDSON is fish counting, fish sizing, and fish behavioral studies. DIDSON records video-quality data, so processing power for handling the vast amount of data with high speed is a priority. Therefore, a semiautomated analysis of DIDSON data for fish counting, sizing, and fish behavior in Echoview (fisheries acoustic data analysis software) was accomplished using testing data collected on the Rakaia River, New Zealand. Using this data, the methods and algorithms for background noise subtraction, image smoothing, target (fish) detection, and conversion to single targets were precisely illustrated. Verification by visualization identified the resulting targets. As a result, not only fish counts but also fish sizing information such as length, thickness, perimeter, compactness, and orientation were obtained. The alpha-beta fish tracking algorithm was employed to extract the speed, change in depth, and the distributed depth relating to fish behavior. Tail-beat pattern was depicted using the maximum intensity of all beams. This methodology can be used as a template and applied to data from BlueView two-dimensional imaging sonar.

음향방출을 이용한 복합재 압력용기의 건전성 평가 (The Structural Integrity Evaluation of Composite Pressure Vessel Using Acoustic Emission)

  • 이상호;최용규
    • 한국추진공학회지
    • /
    • 제1권2호
    • /
    • pp.1-11
    • /
    • 1997
  • 본 연구에서는 음향방출법을 활용한 복합재 연소관의 구조적 건전성 평가 방법을 개발하기 위하여 표준 평가용 시험 시편의 수압 시험 중, 압력용기로부터 방출되는 음향방출 신호를 측정함으로써 시편이 파괴되기 전, 대략적인 시편의 파열 위치 예측 및 일정 압력 유지 상태에서 hit rate(hit/sec) 양상에 의한 시편의 건전성 평가 방법을 제시하였다. 데이터 분석 기법의 향상을 위하여 음향방출 데이터를 시간 및 센서별로 분류하는 프로그램을 개발하였다. 수압 시험을 낮은 압력 단계부터 높은압력 단계까지 일정 압력 유지 상태에서 발생한 hit 수와 1분간 유지한 후, 발생되는 hit rate의 값의 크고 작음이 복합재 압력 용기의 결함수의 증감으로 나타났으며, 이로부터 복합재 압력 용기의 파열 압력과의 상관 관계 및 건전성을 예측할 수 있었다. 복합재 압력 용기의 파열 위치는 energy rate(energy/sec) 측정값을 분석하여 예측하였으며, 시편 파열 압력의 25∼36%에서 가능하였다.

  • PDF

위치 인식이 가능한 WBAN 용 UWB 수신기 (UWB WBAN Receiver for Real Time Location System)

  • 하종옥;박명철;정승환;어윤성
    • 전자공학회논문지
    • /
    • 제50권10호
    • /
    • pp.98-104
    • /
    • 2013
  • 본 논문에서는 무선 통신 및 근거리 위치 인식이 가능한 WBAN(wireless body area network) 용 UWB(Ultra-wide band) 수신기 회로를 제안한다. UWB 수신기는 에너지 검출 방식의 OOK(on-off keying) 변조가 가능하도록 설계가 되었다. 고속의 sampling 을 하기 위해서 4bit ADC 는 DLL(delay locked loop) 을 이용하여 sub-sampling 기법을 사용하도록 설계되었다. 제안된 UWB 수신기는 CMOS $0.18{\mu}m$ 공정을 이용하여 설계되었으며, 전원 전압 1.8V에서 61mA의 전류를 소모하면서 -85.7dBm의 수신 감도, 42.1dB의 RF front-end 게인, 3.88 dB의 noise figure, 최대 4m 까지의 거리 감지 성능을 가지고 있다.

용접선 자동추적을 위한 이중 전자기센서의 개발에 관한 연구 (A Study of a Dual-Electromagnetic Sensor for Automatic Weld Seam Tracking)

  • 신준호;김재응
    • Journal of Welding and Joining
    • /
    • 제18권4호
    • /
    • pp.70-75
    • /
    • 2000
  • The weld seam tracking system for arc welding process uses various kinds of sensors such as arc sensor, vision sensor, laser displacement and so on. Among the variety of sensors available, electro-magnetic sensor is one of the most useful methods especially in sheet metal butt-joint arc welding, primarily because it is hardly affected by the intense arc light and fume generated during the welding process, and also by the surface condition of weldments. In this study, a dual-electromagnetic sensor, which utilizes the induced current variation in the sensing coil due to the eddy current variation of the metal near the sensor, was developed for arc welding of sheet metal butt-joints. The dual-electromagnetic sensor thus detects the offset displacement of weld line from the center of sensor head even though there's no clearance in the joint. A set of design variables of the sensor were determined for the maximum sensing capability through the repeated experiments. Seam tracking is performed by correcting the position of sensor to the amount of offset displacement every sampling period. From the experimental results, the developed sensor showed the excellent capability of weld seam detection when the sensor to workpiece distance is near less than 5 mm, and it was revealed that the system has excellent seam tracking ability for the butt-joint of sheet metal.

  • PDF

스핀코팅법으로 제작한 산화구리 박막의 일산화질소 가스 감지 특성 (Nitrogen Monoxide Gas Sensing Properties of Copper Oxide Thin Films Fabricated by a Spin Coating Method)

  • 황현정;김효진;김도진
    • 한국재료학회지
    • /
    • 제25권4호
    • /
    • pp.171-176
    • /
    • 2015
  • We present the detection characteristics of nitrogen monoxide(NO) gas using p-type copper oxide(CuO) thin film gas sensors. The CuO thin films were fabricated on glass substrates by a sol-gel spin coating method using copper acetate hydrate and diethanolamine as precursors. Structural characterizations revealed that we prepared the pure CuO thin films having a monoclinic crystalline structure without any obvious formation of secondary phase. It was found from the NO gas sensing measurements that the p-type CuO thin film gas sensors exhibited a maximum sensitivity to NO gas in dry air at an operating temperature as low as $100^{\circ}C$. Additionally, these CuO thin film gas sensors were found to show reversible and reliable electrical response to NO gas in a range of operating temperatures from $60^{\circ}C$ to $200^{\circ}C$. It is supposed from these results that the p-type oxide semiconductor CuO thin film could have significant potential for use in future gas sensors and other oxide electronics applications using oxide p-n heterojunction structures.

Simultaneous Determination of Sulfonamides in Porcine and Chicken Muscle Using High Performance Liquid Chromatography with Ultraviolet Detector

  • Shim, You-Sin;Shin, Dong-Bin;Cho, Yong-Sun;Choi, Yun-Hee;Lee, Sang-Hee
    • Food Science and Biotechnology
    • /
    • 제18권6호
    • /
    • pp.1430-1434
    • /
    • 2009
  • The present study used the liquid extraction pretreatment method and developed a liquid chromatographyultraviolet detector (LC-UV) for the simultaneous determination of 14 sulfonamides (SAs) residues in porcine and chicken muscle. Linearity within a range of $50-150\;{\mu}g/kg$ was obtained with the correlation coefficient ($r^2$) of 0.9673-0.9997. The mean recovery of SAs was 55.9-109.7% (relative standard deviations; RSDs 1.7-17.3%) in porcine muscle and 52.8-112.4% (RSDs 2.3-16.9%) in chicken muscle. The limits of detection (LODs) and limits of quantification (LOQs) were 2-32 and $7-96\;{\mu}g/kg$ in porcine muscle, and 4-32 and $13-97\;{\mu}g/kg$ in chicken muscle, respectively. These values were lower than the maximum residue limits (MRLs) established by the European Union. The sum of all SAs residues present should be less than $100\;{\mu}g/kg$.

북서 태평양 멸치(Japanese anchovy)에 대한 측면 음향 반사강도 특성 (In situ side-aspect target strength of Japanese anchovy (Engraulis japonicus) in northwestern Pacific Ocean)

  • 이형빈;강돈혁
    • 수산해양기술연구
    • /
    • 제46권3호
    • /
    • pp.248-256
    • /
    • 2010
  • Acoustic side-aspect target strength (TS) of living Japanese anchovy (Engraulis japonicus) was measured at 120kHz during in situ experiments. The data were collected by lowering and horizontally projecting the splitbeam transducer into the anchovy school. For analysis and interpretation of the side-aspect TS data, acoustic theoretical model, based on the fish morphology, and dorsal-aspect TS data were used. Total length of the anchovy ranged from 6.6 to 12.8cm (mean length 9.3cm). The side-aspect TS distributed between -40 and -55dB, has an obvious length dependency. The mean side-aspect TS of the anchovy was -47.8dB, and the TS was about 2dB higher than mean TS generated from dorsal-aspect measurements. With reference to maximum TS, the results of the side-aspect TS were distributed within the range of the theoretical and dorsal-aspect TS. Apparently these tendency indicates that side-aspect TS measured from the study is useful data. These in situ measurements of side-aspect TS can be applied to improve acoustic detection and estimates of the anchovy, and is necessary to measure with a various frequency and length for making enhance data.

Aflatoxin M1 in Pasteurized Market Milk in Korea

  • Hwang, Kyu-Choon;Hwang, Joo-Yea;Kim, Hyoun-Wook;Oh, Mi-Hwa
    • 한국축산식품학회지
    • /
    • 제32권3호
    • /
    • pp.376-378
    • /
    • 2012
  • Aflatoxin M1, ingested as aflatoxin B1 via contaminated feedstuff and later converted into, is a major problematic target for milk safety control among the aflatoxin class. Korean government has controlled level of AFM1 in milk at 500 ppt as maximum residue level (MRL), and more recently, government also publicized the proposal for more strict control on fungal toxins about infant and baby foods. In this study the levels of Aflatoxin M1 (AFM1) of 42 marketed milk samples were determined with Enzyme-Linked Immunosorbent Assay (ELISA) to evaluate the status on the contamination of Aflatoxin M1. The evaluated ELISA performances of limit of detection (LOD) and the half maximal inhibitory concentration ($IC_{50}$) were 5 pg/mL (ppt) and 49 ppt, respectively. In all 42 samples, AFM1 appeared above the 5 ppt, with the average of 21 ppt and the range of up to 90 ppt. Only 3 (7%) of samples showed the level of contamination above the EU MRL (50 ppt). Although there was incidence of higher level of contamination compared with previous reports, the result of this study requires more intensive study to control of AFM1 in milk and infant foods.

BSO와 ZnSe를 광 변조기로 이용한 전류센서에 관한 연구 (A Study on the Current Sensor Using an Optical Modulator with BSO)

  • 김요희;이대영
    • 전자공학회논문지A
    • /
    • 제28A권9호
    • /
    • pp.721-728
    • /
    • 1991
  • In this paper, a magneto-optic modulator has been designed by using single crystal BSO and polycrystal ZnSe as Faraday cells. And practical core-type optical current sensors using pure iron and permalloy have been prepared and experimented. In order to obtain efficient magnetic field detection, LED(NEC OD08358, 0.87 $\mu$m) was used as optical source, PIN-PD(OD-8454)as optical receiver and multi-mode optical fiber (100/140$\mu$m) as transmission line. The characteristics matrix of the optical element was calculated by Stokes parameter, and optic modulation characteristics equations were derived by Muller matrix. Electromagnetic analysis program (FLUX 2D, micro VAX 3600) by finite element method was used to find the magnetic flux density around the core. The measuring error of the output voltage to input current has been masured below 5% in the range of 50A to 1000A. As the temperature was changed from -20$^{\circ}C$ to 60$^{\circ}C$, the maximum measurement error of the optical output has been found to be 0.5% at 60$^{\circ}C$. These experimental results show good temperature and linearity characteristics. The SNR of the overall system was 47dB in case of 600A (250.2 Oe) conductor current and the system has good noise immunity.

  • PDF