• Title/Summary/Keyword: Maximum a Posterior

Search Result 263, Processing Time 0.026 seconds

Use of separate single-tooth implant restorations to replace two or more consecutive posterior teeth: a prospective cohort study for up to 1 year

  • Kwon, Min-Jung;Yeo, In-Sung;Kim, Young-Kyun;Yi, Yang-Jin;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.2
    • /
    • pp.54-57
    • /
    • 2010
  • PURPOSE. The aim of this study was to evaluate the periodontal and prosthodontic complications of multiple freestanding implants in the posterior jaws for up to 1 year of function. MATERIALS AND METHODS. Eight patients received 20 implants posterior to canines. Two or more implants were consecutively inserted to each patient. Single crowns were delivered onto the implants. Marginal bone loss, implant mobility, probing depth, and screw loosening were examined to evaluate the clinical success of such restorations for maximum 1 year of functional loading. RESULTS. All the implants performed well during the observation period. Neither periodontal nor prosthodontic complications were found except a slight porcelain chipping. While the marginal bone level was on average 0.09 mm lower around the implant after 6 months of loading, it was 0.15 mm higher after 1 year. CONCLUSION. Within the limits of this investigation, separate single-tooth implant restorations to replace consecutive missing teeth may clinically function well in the posterior jaw.

Evaluation of reliability of zirconia materials to be used in implant-retained restoration on the atrophic bone of the posterior maxilla: A finite element study

  • Degirmenci, Kubra;Kocak-Buyukdere, Ayse;Ekici, Bulent
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.2
    • /
    • pp.112-119
    • /
    • 2019
  • PURPOSE. Zirconia materials have been used for implant-retained restorations, but the stress distribution of zirconia is not entirely clear. The aim of this study is to evaluate the stress distribution and risky areas caused by the different design of zirconia restorations on the atrophic bone of the posterior maxilla. MATERIALS AND METHODS. An edentulous D4-type bone model was prepared from radiography of an atrophic posterior maxilla. Monolithic zirconia and zirconia-fused porcelain implant-retained restorations were designed as splinted or non-splinted. 300-N occlusal forces were applied obliquely. Stress analyses were performed using a 3D FEA program. RESULTS. According to stress analysis, the bone between the 1) molar implant and the 2) premolar in the non-splinted monolithic zirconia restoration model was stated as the riskiest area. Similarly, the maximum von Mises stress value was detected on the bone of the non-splinted monolithic zirconia models. CONCLUSION. Splinting of implant-retained restorations can be more critical for monolithic zirconia than zirconia fused to porcelain for the longevity of the bone.

A Retrospective Study of Sintered Porous-surfaced Dental Implants in Restoring the Edentulous Posterior Mandible: Up to Eight Years of Functioning (하악 구치부에 식립한 sintered porous surfaced implants의 후향적 다기관 연구)

  • Kim, Woo-Sung;An, Kyung-Mi;Sohn, Dong-Seok;Jung, Heui-Seung;Shin, Im-Hee
    • The Journal of the Korean dental association
    • /
    • v.47 no.12
    • /
    • pp.823-829
    • /
    • 2009
  • Purpose : The aim of this study was to evaluate the survival rate of sintered porous-surfaced implants placed in the edentulous posterior mandibles, in relation to implant length and diameter, crown-to-implant ratio, and types of prostheses, for a maximum of eight years of functioning. Material and Methods : The study group consisted of 43 partially edentulous patients who visited Catholic University Hospital of Daegu and one private dental clinic. A total of 122 sintered porous-surfaced implants n $Endopore^{(R)}$ (Inn ova Life Sciences, Toronto, Ontario, Canada) -- were placed in the edentulous posterior mandibles, Two diameter sizes (4.1 mm and 5.0 mm) and four lengths (5.0 mm, 7.0 mm, 9.0 mm, and 12.0 mm) were used. One hundred and three implants were splinted and 21 implants were nonsplinted. The survival rates of the implants in relation to length, diameter, crown-to-implant ratio, and types of prostheses were investigated. Statistical data were analyzed using SPSS Win.Ver 14.0 software with the Chi-square test. Results : The survival rate of the 4.1mm diameter implants was 100% and 91.2% for the 5.0mm diameter implants. The survival rates of the implants of differing diameters were found to be statistically different (p=0.005). The survival rates of both the 5.0mm and 7.0 mm length implants were 100%. The survival rate of the 9.0mm length implants was 97.9% and for the 12.0mm length implants was 95.1%. There was no statistical difference in survival rates for the differing lengths of implants. Of the 103 prostheses that were splinted, the survival rate was 98.0%. The survival rate of splinted prostheses was higher than that of the non-splinted prostheses, but was found to be not statistically different. There were no failed cases when the crown-to-implant ratio was under 1.0. When the crown-to-implant ratio was between 1.0 and 1.5, the failure rate of the implants was 6.7%. No failure was recorded with the ratio range of 1.5 to 2.0. Relative to the crown-to-implant ratio of 1.0, the failure rates were statistically different (p=0.048). Discussion and Conclusion : The cumulative survival rate of the porous-surfaced implants placed in the edentulous posterior mandibles was 97.5%. Short porous-surfaced implants showed satisfactory results after a maximum of nine years of functioning in the edentulous posterior mandibles.

  • PDF

Effects of Freezing of Gait on Spatiotemporal Variables, Ground Reaction Forces, and Joint Moments during Sit-to-walk Task in Parkinson's Disease

  • Park, Hwayoung;Youm, Changhong;Son, Minji;Lee, Meounggon;Kim, Jinhee
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.1
    • /
    • pp.19-27
    • /
    • 2018
  • Objective: This study aimed to analyze the effects of freezing of gait on spatiotemporal variables, ground reaction forces (GRFs), and joint moments during the sit-to-walk task at the preferred and maximum speeds in patients with Parkinson's disease (PD). Method: The subjects were classified by a neurologist into 12 freezers, 12 non-freezers, and 12 controls. Sit-to-walk parameters were measured during three repetitions of the task in a random order at the preferred and maximum possible speeds. Results: In the sit-to-walk task at the preferred speed, the freezers and non-freezers exhibited a higher peak anterior-posterior GRF (p<0.001) in the sit-to-stand phase and lower step velocity (p<0.001), step length (p<0.001), and peak anterior-posterior GRF (p<0.001) in the first-step phase than the controls. The freezers had higher peak anterior-posterior GRF (p<0.001) and peak moment of the hip joint (p=0.008) in the sit-to-stand phase than the non-freezers. In the sit-to-walk phase at the maximum speed, the freezers and non-freezers had lower peak moment of the hip joint (p=0.008) in the sit-to-stand phase than the controls. The freezers and non-freezers displayed lower step velocity (p<0.001) and peak anterior-posterior GRF (p<0.001) in the first-step phase than the controls. The freezers showed higher peak moments of the hip joint in the sit-to-stand phase than the non-freezers (p=0.008). Conclusion: The PD patients had reduced control ability in sit-to-stand motions for efficient performance of the sit-to-walk task and reduced performance in the sit-to-walk task. Furthermore, the freezers displayed reduced control ability in the sit-to-stand task. Finally, the PD patients exhibited a lower ability to control dynamic stability with changes in speed than the controls.

Reliability of the Mixture Model with Gamma Family Using Gibbs Sampler (깁스추출법을 이용한 감마족 신뢰확률 혼합모형에 대한 연구)

  • 김평구
    • Journal of Korean Society for Quality Management
    • /
    • v.27 no.1
    • /
    • pp.80-90
    • /
    • 1999
  • In this paper, reliability estimation using Gibbs sampler is considered for the mixture model with Gamma family, Gibbs sampler is derived to compute the features for the posterior distribution. By simulation study, the maximum likelihood estimator and the Gibbs estimator are obtained. A numerical study with a simulated data is provided.

  • PDF

Initial Lengthening Behavior of Cadaveric Achilles Tendon Graft After Posterior Cruciate Ligament Reconstruction (후방십자인대 재건술 후 사체 아킬레스 이식건의 초기연신거동)

  • Kim, Cheol-Woong;Bae, Ji-Hoon;Lee, Ho-Sang;Wang, Joon-Ho;Park, Jong-Woong;Oh, Dong-Joon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1461-1466
    • /
    • 2008
  • In the case of Posterior Cruciate Ligament (PCL), the most frequent mechanism is the dashboard injury, which is directly pressurized to the anterior of the proximal tibia in the state of the knee hyperflexion. The PCL associated ligament damage happens when the posterior injury, the varus, the valgus, the hyperextension and the severe vagus torque are out of the critical value of PCL. After the successful operation cases of Anterior Cruciate Ligament (ACL) reconstruction using the allograft were informed from 1986, a number of results kept over the maximum 10 years were reported. Unfortunately, PCL reconstruction are crowded the surgery techniques such as the graft, the tibia fixing method, the fixation device, the location of the femoral tunnel, the number of the graft bundles and PCL reconstruction to access to the stability of the normal joint is being developed. Therefore, this study is the basic research of these above facts. The current transtibial tunnel surgery using the cadaveric Achilles tendon grafts is chosen for the various PCL reconstruction. The initial extension of the Achilles tendon by the fixing device and its location under the cyclic loading, were observed.

  • PDF

Determinacy on a Maximum Resolution in Wavelet Series

  • Park, Chun-Gun;Kim, Yeong-Hwa;Yang, Wan-Youn
    • Journal of the Korean Data and Information Science Society
    • /
    • v.15 no.2
    • /
    • pp.467-476
    • /
    • 2004
  • Recently, an approximation of a wavelet series has been developed in the analyses of an unknown function. Most of articles have been studied on thresholding and shrinkage methods for its wavelet coefficients based on (non)parametric and Bayesian methods when the sample size is considered as a maximum resolution in wavelet series. In this paper, regardless of the sample size, we are focusing only on the choice of a maximum resolution in wavelet series. We propose a Bayesian approach to the choice of a maximum resolution based on the linear combination of the wavelet basis functions.

  • PDF

A STUDY ON THE STRESS DISTRIBUTION OF POSTERIOR FIXED PARTIAL DENTURE WITH VARIOUS ALL-CERAMIC SYSTEMS (구치부 고정성 국소의치에서 전부도재 시스템에 따른 응력분포에 관한 연구)

  • Kang Han-Joong;Dong Jin-Keun;Oh Sang-Chun;Lee Hae-Hyoung;Song Ki-Chang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.204-217
    • /
    • 2005
  • Purpose. The purpose of this study was to analyze stress distribution of all ceramic posterior fixed partial denture using a three dimensional finite element method. Material and method. A three dimensional finite element model was created to demonstrate all-ceramic posterior fixed partial denture and then this computer model measured the stress distribution of the all ceramic bridges which has a ceramic core materials such as Zirconia, IPS Empress. 2. In-Ceram zirconia, Metal-Ceramic. Also the stress distribution was examined according to loading sites when force was applied to sites such as the central area of second premolar the mesial connector of pontic, the central fossa of pontic, the distal connector of pontic, and the central fossa of second molar. Results. 1. In all the materials of the core in this study, von Mises stress indicated that the stress increased as force was applied to loaded sites, just at those points, on the connector, and the margin in the area adjacent to the connectors. 2. The maximum principal stress was much higher in the lower part of the connectors than in any other region. 3. As the load was applied to the different locations, the research showed a consistent increase of stress in the lower connectors. The maximum value of the von Mises stress was two or three times greater when the load was applied directly to the connectors rather than indirectly through another stressed region. 4. In the case of In-Ceram zirconia, the stress in lower connectors was the highest of all the reference points, the stress showed 75% of all the maximum stress. Ziconia showed 72%, Metal Ceramic 67% and IPS Empress 2 50%. 5. In the case of Ziconia, the stress was well dispersed in each reference point that the stress differences were smaller when compared to In-Cream ziconia.

Kinematic Character istics to Skill Degree during Dance Sports Rumba Forward Walk (댄스스포츠 룸바 Forward Walk 시 숙련도에 따른 운동학적 특성)

  • Seo, Se-Mi;Kim, Tae-Sam
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.3
    • /
    • pp.293-301
    • /
    • 2010
  • The purpose of this study was to investigate the kinematic difference between skilled and less skilled group for the forward walk at dance sports rumba. Six female players(skilled group: 3, less skilled group: 3) were participated as the subjects. To obtain the three-dimensional location coordinates in the joints and segments, it shot with 100Hz/s using 8 video cameras. Step length, shoulder rotation angle, orientation angle and angular velocity of pelvis were analyzed for each trail. The skilled group showed a bigger movement than the less skilled group at the shoulder rotation angle and ROM. The skilled group showed a bigger movement than the less skilled group at the up/down obliquity and internal/external rotation movement for pelvis. And the skilled group showed a bigger movement than the less skilled group at Maximum angle (down obliquity) of P2 and Maximum angle (up obliquity) of P3 to pelvis ROM. The skilled group showed a faster angular velocity than the less skilled group at P2 (+ direction, posterior) of anterior & posterior tilt, P2 & P3 (- direction, up) of up & down obliquity, and P2 (+ direction, external) of internal & external rotation.

Reproductive Biology of the Pen Shell, Atrina(Servatrina) pectinata on the Boryeong Coastal Waters of Korea

  • Chung, Ee-Yung;Baik, Seong-Hyeon;Ryu, Dong-Ki
    • The Korean Journal of Malacology
    • /
    • v.22 no.2
    • /
    • pp.143-150
    • /
    • 2006
  • The gonad index, condition index, reproductive cycle and spawning of the pen shell Atrina (Servatrina) pectinata were investigated using samples from the subtidal zone of Nokdo on the Boryeong coastal waters of Korea. Samples were collected monthly by SCUBA divers for one year from January to December, 2001. A. (Servatrina) pectinata is dioecious and oviparous. The spawning season of this species occurred once a year from June to August, with the main spawning occurring between June and July when the seawater temperature was around $20^{\circ}C$. Ripe oocytes were about 60-65 ${\mu}m$ in diameter. The reproductive cycle of this species could be classified into five successive stages; early active stage (November to March), late active stage (February to May), ripe stage (April to July), partially spawned stage (June to August), and spent/inactive stage (August to October). Monthly changes in the gonad index reached a maximum (4.6) in May (ripe stage), thereafter, the GI values gradually decreased from June to August when spawning occurred continuously. Therefore, monthly changes in the GI values showed a similar pattern to the gonadal phase. The condition index (CI) of the meat part without the posterior adductor muscle reached the maximum in June (ripe and partially spawned stage) and the minimum in September (spent/inactive stage), Accordingly, monthly changes in the condition indice of the meat part without the posterior adductor muscle coincided with the gonadal phases.

  • PDF