• Title/Summary/Keyword: Maximum Power Output Condition

Search Result 130, Processing Time 0.031 seconds

Maximum Power Output Condition of the Binary Power Cycle Composed of Two Carnot Cycles (이중 동력 사이클의 최대 출력 조건)

  • 김창욱;김수연;정평석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.349-354
    • /
    • 1991
  • The power output behavior of the binary cycle composed of two Carnot cycles is analyzed with considering heat transfer processes, in which the finitely constant temperature differences between heat sources and working fluids exists. The power output has the maximum value as an extremum for cycle temperatures and capacities of heat exchangers. In the internally reversible cycle, the power output is independent of the cycle temperature in the intermediate heat exchanger. In this case when the total capacities of heat exchangers are given, three heat exchangers have the same capacities at the maximum power output condition. In addition, when the cycle is not extremum for cycle temperatures and capacities of heat exchangers. At the maximum power output condition, the capacity of heat exchanger at the cold side is slightly more than the hot side as the cycle effectiveness decreases.

Novel Unified Criterion to Optimize Power Coupling at Optical Directional Couplers with Discontinuity Interface (불연속 경계면을 갖는 광 방향성 결합기의 최적 결합효율을 위한 새로운 통합기준)

  • Ho, Kwang-Chun
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.627-630
    • /
    • 2005
  • Novel unified criterion to optimize power coupling at optical directional couplers with discontinuous input/output interfaces is first defined and evaluated numerically. The numerical results reveal that maximum power transfer between guiding slabs without discontinuous interfaces is dominated by conventional phase-matching condition while the guiding structures with discontinuous interfaces has maximum power transfer at an equi-partition condition, which describes the power distribution condition between two rigorous modes propagating through optical couplers.

  • PDF

The Control Characteristics of PV System Using Discrete Data Signal (이산치 신호를 이용한 PV시스템의 제어특성)

  • 김동휘;백형래
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.93-96
    • /
    • 1999
  • Solar cell generate DC power from sunlight whose power is different at any instance according to condition of variables : insolation and temperature. In order to improve the system utility factor and efficiency of energy conversion, it is desirable to operate the PV system at maximum power point of solar cell under different condition. In this paper, Boost chopper is controlled it output voltage with a new discrete control algorithm for MPPT. PWM signal of DC-DC converter are generated with a 89C51 microcontroller. Switching frequency of DC-DC converter is set at 10KHz. Simulation and experimental results show that the PV system studied in this paper is always operated at maximum power point under different maximum power point of solar cells having stabilized output voltage waveform with relatively small ripple component

  • PDF

DESIGN OF A LOW TEMPERATURE DIFFERENCE STIRLING ENGINE (저온도차 모형 스털링 엔진의 최대출력 설계조건)

  • Jung, P.S.;Won, M.Y.;Kim, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.420-423
    • /
    • 2003
  • A low temperature difference model Stirling engine is a small Stirling engine running with several degree of temperature difference without power output. In this study, the design parameters to give maximum power are discussed. As results, the phase angle is about 100 degree, and compression ratio is 1.5% of the ratio of heat source temperatures at maximum power condition.

  • PDF

Optimization of PEM Fuel Cell System Using a RSM (반응표면기법에 의한 고분자전해질형 연료전지 시스템의 최적화)

  • Xuan, Dongji;Kim, Jin-Wan;Nan, Yanghai;Ning, Qian;Kim, Young-Bae
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3140-3141
    • /
    • 2008
  • The output power efficiency of the fuel cell system depends on the demanded current, stack temperature, air excess ratio, hydrogen excess ratio and inlet air humidity. Thus, it is necessary to determine the optimal operation condition for maximum power efficiency. In this paper, we developed a dynamic model of fuel cell system which contains mass flow model, diffusivity gas layer model, membrane hydration and electrochemistry model. In order to determine the maximum output power and minimum use of hydrogen in a certain power condition, response surface methodology (RSM) optimization based on the proposed PEMFC stack model is presented. The results provide an effective method to optimize the operation condition under varied situations.

  • PDF

Global Maximum Power Point Tracking Method of Photovoltaic Array using Boost Converter (부스트 컨버터를 이용한 태양전지 어레이 전역 최대전력 점 추종 방법)

  • Hwang, Dong-Hyeon;Lee, Woo-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.2
    • /
    • pp.216-223
    • /
    • 2018
  • Since solar cells have non-linear voltage-current output characteristics, Photovoltaic systems require the Maximum Power Point Tracking(MPPT) function. For this reason, a large number of MPPT techniques have been studied. However, the conventional MPPT techniques may fail to track the maximum power point when partial shading occurs in the solar cell array due to its characteristics. Therefore, it is necessary to research the MPPT technique that can follow the maximum power point in the partial shadow condition. In this paper, the characteristics of solar cell arrays in partial shadowing are analyzed and the MPPT technique which can follow the maximum power point in partial shadow condition has been proposed. To validate the proposed MPPT method, simulation and experimentation results are provided.

High Efficiency Design Procedure of a Second Stage Phase Shifted Full Bridge Converter for Battery Charge Applications Based on Wide Output Voltage and Load Ranges

  • Cetin, Sevilay
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.975-984
    • /
    • 2018
  • This work presents a high efficiency phase shifted full bridge (PSFB) DC-DC converter for use in the second stage of a battery charger for neighborhood electrical vehicle (EV) applications. In the design of the converter, Lithium-ion battery cells are preferred due to their high voltage and current rates, which provide a high power density. This requires wide range output voltage regulation for PSFB converter operation. In addition, the battery charger works with a light load when the battery charge voltage reaches its maximum value. The soft switching of the PSFB converter depends on the dead time optimization and load condition. As a result, the converter has to work with soft switching at a wide range output voltage and under light conditions to reach high efficiency. The operation principles of the PSFB converter for the continuous current mode (CCM) and the discontinuous current mode (DCM) are defined. The performance of the PSFB converter is analyzed in detail based on wide range output voltage and load conditions in terms of high efficiency. In order to validate performance analysis, a prototype is built with 42-54 V / 15 A output values at a 200 kHz switching frequency. The measured maximum efficiency values are obtained as 94.4% and 76.6% at full and at 2% load conditions, respectively.

Real Maximum power point tracking for loss compensation of PV array under partially shaded condition (태양전지 어레이 음영 변화에 따른 손실 보상을 위한 최대전력점 추종 기법)

  • Jung, Hoon-Young;Ji, Young-Hyok;Jung, Doo-Yong;Lee, Su-Won;Won, Chung-Yuen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.317-320
    • /
    • 2009
  • Under partial shading condition, the multiple local maxima can be existed on the output characteristics of PV array. In case of the conventional MPPTs (i.e P&O or IncCond), the failure of maximum power point tracking could be occurred under partial shading condition(PSC). The problems are deduced by the analysis of conventional MPPTs. In this paper, a real maximum power point tracking for PV array under partially shaded condition is proposed. And proposed MPPT is analyzed by case study. It is confirmed by simulation results that the proposed MPPT can track the real MPP under partial shading condition.

  • PDF

A Numerical Study on the Effect of Inlet Guide Vane Angle on the Performance of Francis Hydraulic Turbine

  • Kim Chul-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.7
    • /
    • pp.750-757
    • /
    • 2005
  • The objective of this study is an understanding of the effect of inlet flow angle on the output power performance of a Francis hydraulic turbine, An optimum induced angle at the inlet of the turbine is one of the most important design parameters to have the best performance of the turbine at a given operating condition, In general. rotating speed of the turbine is varied with the change of water mass flowrate in a volute, The induced angle of the inlet water should be properly adjusted to the operating condition to have maximum energy conversion efficiency of the turbine, In this study. a numerical simulation was conducted to have detail understanding of the flow phenomenon in the flow path and output power of the model Francis turbine. The indicated power produced by the model turbine at a given operating condition was found numerically and compared to the brake power of the turbine measured by experiment at KIER. From comparison of two results, turbine efficiency or energy conversion efficiency of the model turbine was estimated. From the study, it was found that the rotating power of the turbine linearly increased with the rotating speed. It means that the higher volume flow rate supplied. the bigger torque on the turbine shaft generated. The maximum brake efficiency of the turbine is around 46$\%$ at 35 degree of induced angle. The difference between numerical and experimental output of the model turbine is defined as mechanical efficiency. The maximum mechanical efficiency of the turbine is around 93$\%$ at 25$\∼$30 degree of induced angle.

The Realization of MPPT Controller Using Fuzzy Controller for Photovoltaic System (퍼지제어기를 이용한 태양광발전시스템의 MPPT 제어기 구현)

  • Cho, Geum-Bae;Choi, Yeon-Ok;Baek, Hyung-Lae
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.89-96
    • /
    • 2004
  • PV system is easy to operate and maintain than the other power generating system since it generally contains no moving parts, operates silently and requires very little maintenance. A solar cell generates DC power from sunlight whose power is different at any instance according to condition of irradiation and temperature variables. In order to improve the system utility factor and efficiency of energy conversion, it is desirable to operate the PV system at maximum power point of solar cell under different condition This paper describes the experimental results of the PV system contain solar modules and a DC-DC converter(boost type chopper) using fuzzy controller. The experimental results show that the PV system always operates at maximum power point of solar cells having stabilized output voltage waveform with relatively small ripple component.