• Title/Summary/Keyword: Maximum Number

Search Result 4,884, Processing Time 0.032 seconds

An Experimental Study on Ventilated Supercavitation of the Disk Cavitator (원판 캐비테이터의 환기 초공동에 대한 실험적 연구)

  • Kim, Byeung-Jin;Choi, Jung-Kyu;Kim, Hyoung-Tae
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.3
    • /
    • pp.236-247
    • /
    • 2015
  • In this paper, the experimental equipments for ventilated supercavitation in cavitation tunnel is constructed and the basic data of ventilated supercavitation regard to the entrainment coefficient and Froude number is fulfilled. The experiments are conducted for the disk cavitator with injecting air and the pressure inside cavity and the shape of cavity are measured. As the entrainment coefficient increases while the Froude number is kept constant, the ventilated cavitation number decreases to a minimum value which decreases no more even with increasing the air entrainment. The minimum value of ventilated cavitation number, caused by the blockage effect, decreases according to increasing the diameter ratio of test section to cavitator. The cavity length is rapidly enlarged near the minimum cavitation number. In low Froude numbers, the cavity tail is floating up due to buoyancy and the air inside the cavity is evacuated from its rear end with twin-vortex hollow tubes. However, in high Froude numbers, the buoyancy effect is almost negligible and there is no more twin-vortex tubes so that the cavity shape becomes close to axisymmetric. In order to measure the cavity length and width, the two methods, which are to be based on the cavity shapes and the maximum width of cavity, are applied. As the entrainment coefficient increases after the ventilated cavitation number gets down to the minimum cavitation number, the cavity length still increases gradually. These phenomenon can be confirmed by the measurement using the method based on the cavity shapes. On the other hand, when the method based on the maximum width of cavity is used, the length and width of the cavity agree well with a semi-empirical formular of natural cavity. So the method based on the maximum width of cavity can be a valid method for cavitator design.

The Stability of Excavated Soft Ground Supported by Sheet-pile Walls (강널말뚝 흙막이벽으로 시공된 굴착연약지반의 안정성)

  • Hong Won-Pyo;Kim Dong-Uk;Song Young-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.1
    • /
    • pp.5-14
    • /
    • 2005
  • Based on the field measuring data obtained from excavation sections in Inchon International Airport project, the relationships between the horizontal displacement of sheet-pile walls and the deformations of soft ground around the excavation were investigated. The horizontal displacements of walls according to supporting method occur, and the displacements were found to become larger in the order of anchors, anchors with struts, and struts. The depths of maximum horizontal displacement are varied with supporting systems. If the stability number shows lower than ${\pi}$, the maximum horizontal displacement and the velocity of maximum horizontal displacement are respectively developed less than $1\%$ of excavation depth and 1mm/day. When the stability number shows lower than ${\pi}+2$, the maximum horizontal displacement and the velocity are respectively developed less than $2.5\%$ of excavation depth and 2mm/day. Also, when the stability number shows more than ${\pi}+2$, the maximum horizontal displacement and the velocity rapidly increase. Also, the maximum horizontal displacement is found to increase rapidly when N value is less than 10. The maximum horizontal displacement increases with decreasing the factor of safety against basal heave (Terzaghi, 1943), and the maximum horizontal displacement is found to increase rapidly when the factor of safety against basal heave is greater than 2.0. This value can be proposed as the criterion for the factor of safety against basal heave in Korea.

A Numerical Analysis of the Behavior of the Free Surface in a Moving Cup (이송되는 컵 내부의 자유 표면의 거동 특성에 대한 수치해석)

  • Hong, Tae-Hyub;Chae, Hee-Moon;Kim, Chyang-Nyung
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2997-3002
    • /
    • 2007
  • A manipulator is operated for the motion of mechanical hands or arms by mechanical mechanism. When a cup including liquid inside is shifted by a manipulator, it is important to know how a free surface of the liquid moves. In this study, non-dimensional parameters have been found that affect the rise of the free surface in a cup moving with constant acceleration. The non-dimensional parameters are the dimensionless time, the ratio of inertia effect to vicous effect (Reynolds number), aspect ratio of the liquid inside the cup and acceleration ratio (Froude number). Through this study, the height of the free surface rise in a cup has been predicted. Generally the maximum rise of the free surface is dependent on the Reynolds number and Froude number strongly, but on the aspect ratio weakly. But the influence of the aspect ratio on the maximum rise of the free surface in not negligible in the range 10 < Re < 100.

  • PDF

Piezoelectric Properties of PZW-PMN-PZT Low Loss Multilayer Actuator according to the Number of Multilayer using Pure Ag Internal Electrode (순수한 Ag 내부전극을 사용한 PZW-PMN-PZT 저손실 적층 액츄에이터의 적층수에 따른 압전 특성)

  • Yoo, Ju-Hyun;Lee, Kab-Soo;Lee, Il-Ha
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.6
    • /
    • pp.524-529
    • /
    • 2008
  • In this paper, in order to develop low loss multilayer actuator, piezoelectric properties of PZW-PMN-PZT multilayer actuator sintered at $900^{\circ}C$ low temperature were investigated according to the number of multilayer. The multilayer actuator was fabricated using tape casting method and used pure Ag internal electrode. The density above $8.0\;g/cm^3$ was obtained at all specimens. With increasing number of multilayer, effective electromechanical coupling factor($k_{eff}$) was increased. $k_{eff}$ of multilayer actuator shows the maximum value of 0.283 at 11 layers actuator. However, effective mechanical quality factor(Qm') was decreased according to the increase of number of multilayer. The Qm' of multilayer actuator showed the maximum value of 920 at 5 layers actuator.

An Experimental Study on Forced Convective Heat Transfer in a Rectangular Duct with $180^{\circ}$ Bend (직사각형단면을 갖는 $180^{\circ}$곡관에서의 강제 대류 열전달 특성에 관한 실험적 연구)

  • Moon, C.;Lee, G.H.;Choi, Y.D.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.2
    • /
    • pp.290-301
    • /
    • 1992
  • An experimental study has been performed to investigate the characteristics of forced convective heat transfer in a rectangular duct with a 180.deg. bend. The Nusselt number of outer wall has maximum value near 105.deg. at which secondary flow is most active and the Nusselt number of inner wall has maximum value near the inlet of a duct. Near the outlet of a duct, the Nusselt number of outer wall decreases, the Nusselt number of inner wall increases and so those access each other through the influence of a straight duct attached to the end of a duct with a 180.deg. bend. Results of this experimental study would be the fundamental data when streamline curvature correction models are developed in the numerical study for forced convective heat transfer in a curved duct.

Flow Characteristics of Floating Roof Tank with Varying the Number of Operation and Angle (믹서의 가동 수 및 각도 변화에 따른 유동형 지붕 탱크의 유동특성)

  • Kim, Noh-Hyeong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.3
    • /
    • pp.20-25
    • /
    • 2015
  • In this study, there are 6 mixers that are installed in a 600,000 barrel tank. We identified internal flow characteristics of floating roof tank with varying the number of operation from 4 to 6 because mixer is a variable that influence flow characteristics of the tank. And while varying an angle from Right $60^{\circ}$, Right $30^{\circ}$, Left $30^{\circ}$ to Left $60^{\circ}$, we identified internal flow characteristics of the tank. As a result, maximum velocity of flow was 0.02m/s stationarily when we changed the number of operation from 4 to 6. Maximum velocity of flow by change of an angle was from 0.42m/s to 0.47m/s. Therefore, we identified that these factors don't have a great influence on internal flow characteristics of a tank by investigating results with varying the number of operation and an angle.

ON CLIQUES AND LAGRANGIANS OF HYPERGRAPHS

  • Tang, Qingsong;Zhang, Xiangde;Zhao, Cheng
    • Bulletin of the Korean Mathematical Society
    • /
    • v.56 no.3
    • /
    • pp.569-583
    • /
    • 2019
  • Given a graph G, the Motzkin and Straus formulation of the maximum clique problem is the quadratic program (QP) formed from the adjacent matrix of the graph G over the standard simplex. It is well-known that the global optimum value of this QP (called Lagrangian) corresponds to the clique number of a graph. It is useful in practice if similar results hold for hypergraphs. In this paper, we attempt to explore the relationship between the Lagrangian of a hypergraph and the order of its maximum cliques when the number of edges is in a certain range. Specifically, we obtain upper bounds for the Lagrangian of a hypergraph when the number of edges is in a certain range. These results further support a conjecture introduced by Y. Peng and C. Zhao (2012) and extend a result of J. Talbot (2002). We also establish an upper bound of the clique number in terms of Lagrangians for hypergraphs.

A Study on the Low Power Algorithm for a Task (태스크에 따른 저전력 알고리즘에 관한 연구)

  • Kim, Jae-Jin
    • Journal of Digital Contents Society
    • /
    • v.14 no.1
    • /
    • pp.59-64
    • /
    • 2013
  • In this paper, we proposed low power algorithm for a task. The task means the inside of a necessary processor and external resources to work accomplishment of a system. Each task analyzes a life time and a number of called for implement a low power circuit. First of all, reduce power consumption of a task have maximum power consumption for low power circuit implementation. Therefore, first selecting a task had maximum power consumption. The task had a maximum power consumption ranking consider a life time and a number of called for each task. While a life time of task is long, top priority ranking to decrease power consumption to the task that the number of call generates the power consumption how a disguise is large in case of a lot of task becomes. Frequency decision to have minimum power consumption, and decrease power consumption all the circuit by a change of frequency of the task which the minimum task that a wasting past record is the maximum becomes. Also, keep continuously minimum power consumption, with every effort task until last life time in opening life time, and decrease gets total power consumption. Experiments results show reduction in the power consumption by 5.43% comparing with that [7] algorithm.

Environmental Adaptation of Tall Fescue Varieties in Mountainous Pastures II. Varieties differences of dry matter production and yield components in growth period of Autumn (Tall fescue 품종의 환경적응성 II. 가을철 건물생산의 품종간 차이와 수량구성요소)

  • 이주삼;한성윤;조익환
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.13 no.2
    • /
    • pp.78-85
    • /
    • 1993
  • This experiment was carried out to select for the varieties with high environmental adaptability in mountainous pastures of Taekwalyong area, and the evaluation was based on the data of varietal differences of dry matter production and yield components in Tall fescue cutting at various developmental stages in growth period of autumn. The results were summarized as follows; 1. The varieties with high number of tillers per plant(NT) showed a high dry weight of plant(DW) in all autumn cuttings. These varieties(Barce1 and Fuego) may be more adaptable to mountainous pastures of Taekwalyon area than other varieties. 2. The number of tillers per plant(NT) was significantly positive correlated with dry weight of plant (DW), but dry weight of tiller(WT) was not significantly correlated with dry weight of plant(DW) in all autumn cuttings. 3. The multiple regression equations of autumn cutting stages with mean dry weight of plant(DW) and number of tillers per plant(NT) can be used to estimate the cutting time to obtain maximum mean dry weight of plant(DW) and the highest number of tillers per plant(NT). The maximum mean dry weight of plant(DW) and the highest number of tillers per plant(NT) was estimated at the time of 21 Oct. and 26 Oct, respectively. 4. Dead leaves tended to increase greatly after the 2nd cutting(l4 Oct.) in growth period of autumn. 5. The number of tillers per plant(NT) was an important yield component before tiller density achieved equilibrium, but dry weight of tiller(WT, including dead leaves) was of most significant as a yield determinant after maximum tiller density reached in growth period of autumn.

  • PDF

Forced Convection Cooling Across Rectangular Blocks in a Parallel Channel (블럭이 부착된 수평 유로에서의 강제대류 열전달 해석)

  • 조한승;유재석
    • Journal of Energy Engineering
    • /
    • v.2 no.3
    • /
    • pp.251-257
    • /
    • 1993
  • The purpose of this study is to obtain an improved interpretation of heat transfer phenomena between blocks and fluids in the parallel conducting plates. Flow is two-dimensional, incompressible steady laminar flow over rectangular blocks, representing finite heat source on parallel plate. Heat transfer phenomena, temperature of blocks and heat transfer into the flow field are investigated for different spacings between blocks and Reynolds numbers. Results indicate that Nusselt number on the far upstream corner of the block was higher than that of any part of the block. As Reynolds number and spacings of blocks increased, Nusselt number increased. The distribution of local Nusselt number on the top surface of the conducting plate is similar to the case with insulated plate. Temperature of the block which has heat source in half cubage was approximately twice as high as temperature of the block which has heat source in whole cubage. As Reynolds number and spacings of blocks increased, overall temperature decreased. The peak value of block temperature occurred at position shifted to the right or upper right from center. The maximum temperature of block can be expressed as a function of Reynolds number, spacings between blocks, position of maximum temperature of each block and then it is possible to predict the maximum temperature of blocks.

  • PDF