• Title/Summary/Keyword: Maximum Material Condition

Search Result 445, Processing Time 0.026 seconds

The Effect Of Standard Limits And Fits On The Productivity Of Assembly Robots (표준 Limits 및 Fits가 조립 로보트의 생산성에 미치는 영향)

  • Kim, Sunn-Ho;Knott, Kenneth
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.17 no.2
    • /
    • pp.75-86
    • /
    • 1991
  • This paper presents a methodology to enable the tolerances on mating parts of an assembly to be specified and be compatible to the precision of an assembly robot so as to achieve maximum system performance. The measure of performance is defined as the Probability of Successful Assembly (PSA). A typical loose fastener assembly, usually called peg-in-a-hole is investigated. The Geometric Tolerancing System is adopted to represent position tolerances of mating parts. Two models are presented by considering modifiers on a position tolerance, Regardless of Feature Size (RFS) and Maximum Material Condition (MMC). Using these models, it is analyzed how the Standard Limits and Fits recommended by ANSI influence the performance of an assembly robot. For this analysis, the Standard Limits and Fits are transformed to the representation scheme of the Geometric Tolerancing System. Due to low PSAs when the Standard Limits and Fits are taken into account, the effect of chamfers around a hole is also analyzed.

  • PDF

A Study on the Method for Mitigation of Streaming Electrifiction by the Improvement of Flow Condition in the Oil Folw System of Transformer (변압기 절연유의 순환 계통에서의 흐름 조건의 개선에 의한 유동대전현사의 완화 방법에 관한 연구)

  • 권석두;남상천
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.4
    • /
    • pp.594-600
    • /
    • 1994
  • The maximum charge accumulation in transformers caused by streaming electrification is commonly observed on the bottom area of transformer winding(i.e.the oil inlet of transformer winding). It is because turbulent flows occur in this portion of transformers. Consequently, if we are to reduce the maximum charge accumulation of transformers, it is important that we should have a good understanding of the conditions of the occurence of partial turbulent flows in the oil inlet of transformer winding. With this point in mind, a simple flow model was designed in this study in order to simulate oil flow in the insulation ducts of power transformers. As a method for mitigating charge accummulation, attention was given to (a) a flow path design for the improvement of flow conditions, and (b) the charge tendency of the material used this design. The results of this study show that the above method is useful for mitigating charge accumulation.

  • PDF

The Electrical Properties of SBT Thin Film for Semiconductor Device (반도체 소자용 SBT 박막의 전기적특성)

  • Oh, Yong-Cheul;Cho, Choon-Nam;Kim, Jin-Sa;Shin, Chul-Ki;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05d
    • /
    • pp.86-89
    • /
    • 2003
  • SBT thin film for semiconductor device that is made by RF magnetron sputtering method studied electrical properties under various temperature condition. Dielectric constant who differ annealing condition appears highest in $750[^{\circ}C]$ and it is 213. Also, C-V properties by annealing temperature of SBT thin film for semiconductor device is no change almost to $600[^{\circ}C]$ and shows non-linear butterfly shape more than $650[^{\circ}C]$ Maximum capacitance and difference of smallest capacitance show the biggest difference in $750[^{\circ}C]$ as degree that domain wall motion contributes in ferrelectric polarization value in C-V characteristic curve of ferroelectric that this shows typical ferroelectric properties. Therefore, SBT thin film for semiconductor device that is annealing in $750[^{\circ}C]$ expressed the most superior electrical and ferroelectric properties.

  • PDF

The Fabrication of Chromium Nitride Thin-Film Type Pressure Sensors for High Pressure Application and Its Characteristics (고압용 코롬질화박막형 압력센서의 제작과 그 특성)

  • 정귀상;최성규;서정환;류지구
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.6
    • /
    • pp.470-474
    • /
    • 2001
  • This paper describes the fabrication and characteristics of CrN thin-film type pressure sensors, in which the sensing elements were deposited on SuS. 630 diaphragm by DC reactive magnetron sputtering in an argon-nitride atmosphere(Ar-(10%)N$_2$). The optimized condition of CrN thin-film sensing elements was thickness range of 3500$\AA$ and annealing condition(300$\^{C}$, 3 hr) in Ar-10%N$_2$ deposition atmosphere. Under optimum conditions, the CrN thin-films for strain gauges is obtained a high resistivity, ρ=1147.65 $\mu$Ωcm, a low temperature coefficient of resistance, TCR=186ppm/$\^{C}$ and a high temporal stability with a good longitudinal, 11.17. The output sensitivity of fabricated CrN thin-film type pressure sensors is 2.36 mV/V, 4∼20nA and the maximum non-linearity is 0.4%FS and hysteresis is less than 0.2%FS.

  • PDF

Variation in Leakage Current Characteristics of Polymer Insulator for Various Environmental Condition (여러 환경조건에 대한 고분자애자의 누설전류 특성 변화)

  • Park Jae-Jun;Choi In-Hyuk;Lee Dong-il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.2
    • /
    • pp.169-175
    • /
    • 2006
  • This study investigated variation leakage current maximum value and waveform considering applied voltage phase angel by simulating three environmental conditions, such as fog, salt fog, and kaolin contamination .As the result of applied voltage phase angel characteristics, leakage currents presented almost in phases in the early stage regardless of environmental conditions just after applying the voltage, and the phase of leakage currents certain phase lags for the discharge of the applied voltage when surface discharges occurred due to the continuous environmental contamination. In addition, the difference in phase significantly increased according to the intensity of discharges. The change in distortion rates according to the environmental contamination presented a nearly same level just after applying the voltage. The distortion rate of third harmonic for the fundamental wave presented by the order of fog>salt fog>kaolin when surface discharges occurred due to the applied voltage for certain continued periods. In the case of the fog and salt fog, the scale of spectrums decreased according to the increase in frequencies from the results of the analysis of high frequencies. In addition, the even number frequency presented a relatively large level compared to the odd number frequency under the kaolin contamination.

Characteristics of thin-film type pressure sensors for high pressure (고압용 박막형 압력센서의 특성)

  • 서정환;최성규;정찬익;류지구;남효덕;정귀상
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.737-740
    • /
    • 2001
  • This paper describes the fabrication and characteristics of CrN thin-film type pessure sensors, which the sensing elements were deposited on SUS. 630 diaphragm by DC reactive magnetron sputtering in an argon-nitride atmosphere(Ar-(10%)N$_2$). The optimized condition of CrN thin-film sensing elements was thickness range of 3500${\AA}$ and annealing condition(300$^{\circ}C$, 3 hr) in Ar-10 %N$_2$deposition atmosphere. Under optimum conditions, the CrN thin-films for strain gauges is obtained a high resistivity, $\rho$=1147.65 ${\mu}$$\Omega$cm, a low temperature coefficient of resistance, TCR=-186 ppm/$^{\circ}C$ and a high temporal stability with a good longitudinal, 11.17. The output sensitivity of fabricated CrN thin-film type pressure sensors is 2.36 mV/V, 4∼20 mA and the maximum non-linearity is 0.4 %FS and hysteresis is less than 0.2 %FS.

  • PDF

Improvement of Chemical Mechanical Polishing (CMP) Performance of Nickel by Additions of Abrasive and Various Oxidizers (산화제 및 연마제 첨가를 통한 Nickel CMP 특성 개선 연구)

  • Choi, Gwon-Woo;Kim, Nam-Hoon;Seo, Yong-Jin;Lee, Woo-Sun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.7
    • /
    • pp.605-609
    • /
    • 2005
  • Chemical mechanical polishing (CMP) of Ni was performed by the various ratios of four kinds of oxidizers and an addition of alumina powders as an abrasive in each slurry with the different oxidizers. Moreover, the interaction between the Ni and the each oxidizer was discussed by potentiodynamic polarization measurement, in order to compare the effects of Ni-CMP and electrochemical characteristics on the Ni with the different oxidizers. As an experimental result, the removal rate of Ni reached a maximum at 1 $vol\%$ of $H_2O_2$. Also the removal rates of Ni increased with the audition of alumina abrasives in each slurry. The potentiodynamic polarization of Ni under dynamic condition showed a significant difference in electrochemical behavior by addition of $H_2O_2$ in solutions. Ni showed the perfect passivation behavior in solution without $H_2O_2$ under potentiodynamic polarization condition, while active dissolution dominates in solution with the addition of $H_2O_2$. The results indicate that the surface chemistry and electrochemical characteristics of Ni play an important role in controlling the polishing behavior of Ni.

A Study on Thermally Stratied Hot Water Storage Tank in A Solar Heating System (태양열 난방 시스템에 적용되는 축열조의 성층화에 관한 연구)

  • Hong, Hi-Ki;Kim, Hyo-Kyung
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.1
    • /
    • pp.87-96
    • /
    • 1986
  • An experiment on the devices that enchance the stratification of storage tanks in a solar heat ins system has been carried out. The benefits of thermal stratification in sensible heat storage are to increase the system performance such as the collector efficiency or the fraction of the total load supplied by solar energy. Using the diffuser and the distributor as the stratification enchancement device, the expeliments were perfomed in the different condition of diameter and material of the distributor. As a result of experiments, there exists the diameter of distributor in which the stratification is made maximum under certain design and operation condition. Also it was identified that the kind of distributor material influenced the degree of stratification. Comparing the experimental result to the computational results calculated under the same conditions, the node number N(stratification index) was determined. The results of computer simulation that was performed about the actual solar heating system in Seoul for 24 hours show the relative advantage of stratified over well-mixed storage and the significant improvements in system performance.

  • PDF

Seismic Analysis of Traveling Sea Water Screen (해수여과장치의 내진해석)

  • Kim, Heung-Tae;Lee, Young-Shin;Park, Young-Moon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.3
    • /
    • pp.289-294
    • /
    • 2011
  • In this study, the seismic analysis of traveling sea water screen for nuclear power plant was performed using finite element model. For qualification of traveling sea water screen, the response spectrum analysis was performed using the given operating basis earthquake(OBE) and safe shutdown earthquake(SSE) floor response spectrum. Dynamic analysis of water sea traveling screen was performed using finite element method. The analytical maximum displacements of traveling sea water screen were 2.5 mm under OBE condition and 4.6 mm under SSE condition. The maximum stresses of traveling sea water screen were 24 MPa under OBE condition and 44 MPa under SSE condition, that this results were 18 %, 27% of yield strength of material. Thus, it can shown that the structural integrity of traveling sea water screen has a stable structure for seismic load conditions.

Structural Safety Test and Analysis of Type IP-2 Transport Packages with Bolted Lid Type and Thick Steel Plate for Radioactive Waste Drums in a NPP (원자력발전소의 방사성폐기물 드럼 운반을 위한 볼트체결방식의 두꺼운 철판을 이용한 IP-2형 운반용기의 구조 안전성 해석 및 시험)

  • Lee, Sang-Jin;Kim, Dong-hak;Lee, Kyung-Ho;Kim, Jeong-Mook;Seo, Ki-Seog
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.199-212
    • /
    • 2007
  • If a type IP-2 transport package were to be subjected to a free drop test and a penetration test under the normal conditions of transport, it should prevent a loss or dispersal of the radioactive contents and a more than 20% increase in the maximum radiation level at any external surface of the package. In this paper, we suggested the analytic method to evaluate the structural safety of a type IP-2 transport package using a thick steel plate for a structure part and a bolt for tying a bolt. Using an analysis a loss or dispersal of the radioactive contents and a loss of shielding integrity were confirmed for two kinds of type IP-2 transport packages to transport radioactive waste drums from a waste facility to a temporary storage site in a nuclear power plant. Under the free drop condition the maximum average stress at the bolts and the maximum opening displacement of a lid were compared with the tensile stress of a bolt and the steps in a lid, which were made to avoid a streaming radiation in the shielding path, to evaluate a loss or dispersal of radioactive waste contents. Also a loss of shielding integrity was evaluated using the maximum decrease in a shielding thickness. To verify the impact dynamic analysis for free drop test condition and evaluate experimentally the safety of two kinds of type IP-2 transport packages, free drop tests were conducted with various drop directions. For the tests we examined the failure of bolts and the deformation of flange to evaluate a loss or dispersal of radioactive material and measured the shielding thickness using a ultrasonic thickness gauge to assess a loss of shielding integrity. The strains and accelerations acquired from tests were compared with those by analyses to verify the impact dynamic analysis. The analytic results were larger than the those of test so that the analysis showed the conservative results. Finally, we evaluated the safety of the type IP-2 transport package under the stacking test condition using a finite element analysis. Under the stacking test condition, the maximum Tresca stress of the shielding material was 1/3 of the yielding stress. Two kinds of a type IP-2 transport package were safe for the free drop test condition and the stacking test condition.

  • PDF