In this study, the seismic analysis of traveling sea water screen for nuclear power plant was performed using finite element model. For qualification of traveling sea water screen, the response spectrum analysis was performed using the given operating basis earthquake(OBE) and safe shutdown earthquake(SSE) floor response spectrum. Dynamic analysis of water sea traveling screen was performed using finite element method. The analytical maximum displacements of traveling sea water screen were 2.5 mm under OBE condition and 4.6 mm under SSE condition. The maximum stresses of traveling sea water screen were 24 MPa under OBE condition and 44 MPa under SSE condition, that this results were 18 %, 27% of yield strength of material. Thus, it can shown that the structural integrity of traveling sea water screen has a stable structure for seismic load conditions.
Keywords
seismic analysis; traveling water screen; operating basis earthquake; safe shutdown earthquake; floor response spectrum;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 IEEE Std. 344 (1987) Recommended Practice for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations.
2 US NRC Regulatory Guide 1.61 (1973) Damping Values for Seismic Design of Nuclear Power Plants, October.
3 Vasilopoulos, A.A., Beskos, D.E. (2009) Seismic Design of Space Steel Frames using Advanced Method of Analysis, Soil Dynamic and Earthquake Engineering, 29, pp.194-218.   DOI   ScienceOn
4 Wei Gao (2007) Random Seismic Response Analysis of Truss Structures with Uncertain Parameters, Engineering Structures, 29, pp.1487-1498.   DOI   ScienceOn
5 고우식, 김진, 허익구, 최병원 (2000) 원자력발전소 안전 등급 대형유도전동기의 기기검증, 대한기계학회 추계학술대회논문집A, pp.498-503.
6 이용일 (1995) 원전구조물의 내진해석 및 설계, 한국전산구조공학회 논문집, 8(1), pp.19-25.
7 이준근, 김진영, 이희남 (2002) 울진 원자력발전소 5,6 호기용 공기정화기에 대한 내진검증, 대한기계학회 논문집A,26(7), pp.1376-1383.
8 이흥식, 김명구, 조종두 (2005) 발전소 주 제어실 제어패널의내진해석, 한국소음진동공학회 논문집, 15(6), pp.652-659.
9 정길호, 박병철, 최진유, 강영종 (1998) 국내 내진설계 제도및 기준에 대한 고찰, 한국전산구조공학회 논문집, 11(1),pp.7-16.
10 정철섭 (2010) 응답스펙트럼법을 이용한 지진하중을 받는 원전용 주냉각수펌프의 내진 건전성 평가, 대한기계학회 논문집A, 34(11), pp.1773-1778.
11 황석환, 최재승 (2002) Traveling Water Screen의 내진해석, 대한기계학회 춘계학술대회 논문집, pp.627-632,
12 ASME Section III Division 1 Appendix F (1995) Rules for Evaluaion of Service Loadings with Level D Service Limits.
13 ASME Section III Division 1 Subsection NF (1995) Component Surpports.
14 Fragiacomo, M., Amadio, C., Macorini, L. (2004) Seismic Response of Steel Frames under Repeated Earthquake Ground Motions, Engineering Structures, 26, pp.2021-2035.   DOI   ScienceOn
15 IEEE Std. 323 (1974) Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations.