• Title/Summary/Keyword: Maximum Matching

Search Result 365, Processing Time 0.028 seconds

Performance Evaluation of Scaling based Dynamic Time Warping Algorithms for the Detection of Low-rate TCP Attacks (Low-rate TCP 공격 탐지를 위한 스케일링 기반 DTW 알고리즘의 성능 분석)

  • So, Won-Ho;Shim, Sang-Heon;Yoo, Kyoung-Min;Kim, Young-Chon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.3 s.357
    • /
    • pp.33-40
    • /
    • 2007
  • In this paper, low-rate TCP attack as one of shrew attacks is considered and the scaling based dynamic time warping (S-DTW) algorithm is introduced. The low-rate TCP attack can not be detected by the detection method for the previous flooding DoS/DDoS (Denial of Service/Distirbuted Denial of Service) attacks due to its low average traffic rate. It, however, is a periodic short burst that exploits the homogeneity of the minimum retransmission timeout (RTO) of TCP flows and then some pattern matching mechanisms have been proposed to detect it among legitimate input flows. A DTW mechanism as one of detection approaches has proposed to detect attack input stream consisting of many legitimate or attack flows, and shown a depending method as well. This approach, however, has a problem that legitimate input stream may be caught as an attack one. In addition, it is difficult to decide a threshold for separation between the legitimate and the malicious. Thus, the causes of this problem are analyzed through simulation and the scaling by maximum auto-correlation value is executed before computing the DTW. We also discuss the results on applying various scaling approaches and using standard deviation of input streams monitored.

Improved Binarization and Removal of Noises for Effective Extraction of Characters in Color Images (컬러 영상에서 효율적 문자 추출을 위한 개선된 2치화 및 잡음 저거)

  • 이은주;정장호
    • Journal of Information Technology Application
    • /
    • v.3 no.2
    • /
    • pp.133-147
    • /
    • 2001
  • This paper proposed a new algorithm for binarization and removal of noises in color images with characters and pictures. Binarization was performed by threshold which had computed with color-relationship relative to the number of pixel in background and character candidates and pre-threshold for dividing of background and character candidates in input images. The pre-threshold has been computed by the histogram of R, G, B In respect of the images, while background and character candidates of input images are divided by the above pre-threshold. As it is possible that threshold can be dynamically decided by the quantity of the noises, and the character images are maintained and the noises are removed to the maximum. And, in this study, we made the noise pattern table as a result of analysis in noise pattern included in the various color images aiming at removal of the noises from the Images. Noises included in the images can figure out Distribution by way of the noise pattern table and pattern matching itself. And then this Distribution classified difficulty of noises included in the images into the three categories. As removal of noises in the images is processed through different procedure according to the its classified difficulties, time required for process was reduced and efficiency of noise removal was improved. As a result of recognition experiments in respect of extracted characters in color images by way of the proposed algorithm, we conformed that the proposed algorithm is useful in a sense that it obtained the recognition rate in general documents without colors and pictures to the same level.

  • PDF

A 15b 50MS/s CMOS Pipeline A/D Converter Based on Digital Code-Error Calibration (디지털 코드 오차 보정 기법을 사용한 15비트 50MS/s CMOS 파이프라인 A/D 변환기)

  • Yoo, Pil-Seon;Lee, Kyung-Hoon;Yoon, Kun-Yong;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.5
    • /
    • pp.1-11
    • /
    • 2008
  • This work proposes a 15b 50MS/s CMOS pipeline ADC based on digital code-error calibration. The proposed ADC adopts a four-stage pipeline architecture to minimize power consumption and die area and employs a digital calibration technique in the front-end stage MDAC without any modification of critical analog circuits. The front-end MDAC code errors due to device mismatch are measured by un-calibrated back-end three stages and stored in memory. During normal conversion, the stored code errors are recalled for code-error calibration in the digital domain. The signal insensitive 3-D fully symmetric layout technique in three MDACs is employed to achieve a high matching accuracy and to measure the mismatch error of the front-end stage more exactly. The prototype ADC in a 0.18um CMOS process demonstrates a measured DNL and INL within 0.78LSB and 3.28LSB. The ADC, with an active die area of $4.2mm^2$, shows a maximum SNDR and SFDR of 67.2dB and 79.5dB, respectively, and a power consumption of 225mW at 2.5V and 50MS/s.

Characteristics and Status of Commercial System for Utilizing MMS in Geospatial Information Construction (공간정보 구축 분야의 모바일 매핑 시스템 활용을 위한 상용 시스템의 특징 및 현황 조사)

  • Park, Joon-Kyu;Um, Dae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.36-41
    • /
    • 2017
  • The mobile mapping system first introduced at Ohio State University in 1991 is being developed in various forms as sensor technology develops. The mobile mapping system can acquire geospatial information around amoving object quickly using the information gathered using the position and attitude information of the moving object and the data from various sensors. The mobile mapping system can rapidly acquire large amounts of Geospatial information and MMS provides maximum productivity in the same measurement methods as existing GNSS and total stations. Currently, a variety of systems are being launched, mainly by foreign companies, and they are applied to the construction of geospatial information. On the other hand, the application of domestic technology development or production is insufficient. This paper provides basic data for the introduction of a mobile mapping system to geospatial information related business by conducting the status survey and feature analysis of a commercialized system focusing on the ground-based mobile mapping system. The research identified the current status and characteristics of high-priced, low-priced, indoor, and handheld mobile mapping systems based on vehicles and suggest that the recent system development trends are moving toward lowering the unit prices. The mobile mapping system is currently being developed as a platform for the application of geospatial information construction and the launch of low-cost models. The development of data processing technologies, such as automatic matching and the launch of low-cost models, are forming a basis for the application of mobile mapping systems in the field of geospatial information construction.

Chaotic Disaggregation of Daily Rainfall Time Series (카오스를 이용한 일 강우자료의 시간적 분해)

  • Kyoung, Min-Soo;Sivakumar, Bellie;Kim, Hung-Soo;Kim, Byung-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.9
    • /
    • pp.959-967
    • /
    • 2008
  • Disaggregation techniques are widely used to transform observed daily rainfall values into hourly ones, which serve as important inputs for flood forecasting purposes. However, an important limitation with most of the existing disaggregation techniques is that they treat the rainfall process as a realization of a stochastic process, thus raising questions on the lack of connection between the structure of the models on one hand and the underlying physics of the rainfall process on the other. The present study introduces a nonlinear deterministic (and specifically chaotic) framework to study the dynamic characteristics of rainfall distributions across different temporal scales (i.e. weights between scales), and thus the possibility of rainfall disaggregation. Rainfall data from the Seoul station (recorded by the Korea Meteorological Administration) are considered for the present investigation, and weights between only successively doubled resolutions (i.e., 24-hr to 12-hr, 12-hr to 6-hr, 6-hr to 3-hr) are analyzed. The correlation dimension method is employed to investigate the presence of chaotic behavior in the time series of weights, and a local approximation technique is employed for rainfall disaggregation. The results indicate the presence of chaotic behavior in the dynamics of weights between the successively doubled scales studied. The modeled (disaggregated) rainfall values are found to be in good agreement with the observed ones in their overall matching (e.g. correlation coefficient and low mean square error). While the general trend (rainfall amount and time of occurrence) is clearly captured, an underestimation of the maximum values are found.

The effects of knee joint position sense following local and general load protocols (국소적 부하와 전신적 부하가 슬관절 위치 감각에 미치는 영향)

  • Hwang, Yoon-Tae;Park, Rae-Joon;Choi, Jin-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.3
    • /
    • pp.429-440
    • /
    • 2005
  • The purpose of this study was to compare the effects of knee joint position sense following local and general load protocols in 25 healthy male subjects. Proprioception of the knee joint was evaluated by measuring absolute angular errors at matching angles before, after and between 2 different types of load protocols. Proprioception tests(on the dominant knee) were performed in which proprioception of the passivepassive reproduced and active-active reproduced knee position was measured. Local load was provided with maximum isokinetic knee extension-flexion on the isokinetic dynamometer(Cybex), and general load was 10 minutes running on a treadmill. Peak torque(knee extension and flexion) and heart rate(beats per minute) was evaluated as an indicator of local and general fatigue during load protocols. The results were as follows: 1. For pasive-pasive reproduced knee position test, significant difference in absolute angular errors after general load protocol was detected compared with that before general load protocol(P<.05), significant difference in absolute angular errors after local load protocol was detected compared with that before local load protocol(P<.05). However, no significant difference in absolute angular errors of general load protocol was detected compared with that of local load protocol (P>.05), no significant difference in absolute angular errors of local load protocol was detected compared with that of general load protocol(P>.05). 2. For active-active reproduced knee position test, significant difference in absolute angular errors after general load protocol was detected compared with that before general load protocol(P<.05), significant difference in absolute angular errors after local load protocol was detected compared with that before local load protocol (P<.05). Also, significant difference in absolute angular errors of general load protocol was detected compared with that of local load protocol(P<.05), significant difference in absolute angular errors of local load protocol was detected compared with that of general load protocol(P<.05). 3. A significant decrease of peak torque of knee extensors and flexors was seen after local load, although heart rate was significantly increased(P<.05). No significant change of peak torque of knee extensors and flexors was seen after general load(P>.05), although heart rate was also significantly increased(P<.05). The previous study revealed that knee proprioception is significantly altered when the muscle mechanoreceptors are dysfunctional due to muscle fatigue, although the joint mechanoreceptors have no significantly effect on knee proprioception when the presence of knee muscle fatigue. However, the results of this study are different from those of the previous study in that muscle weakness of the knee could not be seen after general load. This study shows that general load may diminish motor control by the central nervous system. Proprioceptional decline without muscle weakness of knee after general load suggests a change in the proprioceptional pathway without influence from muscle mechanoreceptors.

  • PDF

Design and Fabrication of 5 GHz Band MMIC Power Amplifier for Wireless LAN Applications Using Size Optimization of PHEMTs (PHEMT 크기 최적화를 이용한 무선랜용 5 GHz 대역 MMIC 전력증폭기 설계 및 제작)

  • Park Hun;Hwang In-Gab;Yoon Kyung-Sik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.6A
    • /
    • pp.634-639
    • /
    • 2006
  • In this paper an MMIC 2-stage power amplifier is designed and fabricated for 5GHz wireless LAN applications using $0.5{\mu}m$ gate length PHEMT transistors. The PHEMT gate width is optimized in order to meet the linearity and efficiency of the MMIC power amplifier. The $0.5{\mu}m\times600{\mu}m$ PHEMT for the drive stage and $0.5{\mu}m\times3000{\mu}m$ PHEMT for the amplification stage are the optimized sizes to achieve more than 25dBc of third order IMD at the power level of 3dB back-off from the input P1dB and more than 22dBm output power under a supply voltage of 3.3V. The two-stage MMIC power amplifier is designed to be used for the both of HIPERLAN/2 and IEEE 802.11a because of its broadband characteristics. The fabricated PHEMT MMIC power amplifier exhibits a 20.1dB linear power gain, a maximum 22dBm output power, a 24% power added efficiency under 3.3V supply voltage. The input and output on-chip matching circuits are included on a chip of $1400\times1200{\mu}m^2$.

Colorimetric comparison of single layered dental composite with double layered dental composite (색상 측정 기기를 이용한 복합레진 적층 수복과 단일 수복의 색상 비교 분석)

  • Song, Young-Sang;Kim, Ja-Hyun;Lee, Bin-Na;Jang, Ji-Hyun;Chang, Hoon-Sang;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.2
    • /
    • pp.84-89
    • /
    • 2012
  • Objectives: This study analyzed the difference in color caused by different thickness in enamel layer of composite resins when applied with single and layering placement technique, and evaluated if the results agreed with the shade guide from the manufacturers to verify reliability of the color matching process of the manufacturers. Materials and Methods: For single composite resin samples, 6 mm diameter and 4 mm thickness cylindrical samples were fabricated using Ceram-X mono (DENTSPLY DeTrey) and CIE $L^*a^*b^*$ values were measured with spectrophotometer. Same process was done for layering composite resin samples, making 3 dentinal shade samples, 4 mm thickness, for each shade using Ceram-X duo (DENTSPLY DeTrey) and enamel shade resins were layered in 2 mm thickness and CIE $L^*a^*b^*$ values were measured. These samples were ground to 0.2 mm thickness each time, and CIE $L^*a^*b^*$ values were measured to 1 mm thickness of enamel shade resin. Results: Color difference (${\Delta}E^*$) between single and layering composite resin was 1.37 minimum and 10.53 maximum when layering thicknesses were between 1 mm and 2 mm and 6 out of 10 same shade groups suggested by manufacturer showed remarkable color difference at any thickness (${\Delta}E^*$ > 3.3). Conclusion: When using Ceram-X mono and duo for composite resin restoration, following the manufacturer's instructions for choosing the shade is not appropriate, and more accurate information for Ceram-X duo is needed on the variation and expression of the shades depending on the thickness of the enamel.

Development of UHF Band Tag Antenna using Radio Frequency Identification Multipurpose Complex Card (RFID 다기능 복합 카드용 UHF 대역 소형 태그 안테나 개발)

  • Byun, Jong-Hun;Sung, Bong-Geun;Choi, Eun-Jung;Ju, Dae-Geun;Yoo, Dae-Won;Cho, Byung-Lok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.12B
    • /
    • pp.1452-1458
    • /
    • 2009
  • In this paper, Our proposed Multipurpose Complex Card UHF band RFID small-size Tag antenna. Multi purpose Complex Card UHF band RFID small-size Tag antenna that is to minimize the low efficiency of RFID Tag Read Range that generates space limitation and a conductor surrounded by inducing fingerpring system with dual(HF, UHF) Card is presented. Our proposed UHF band RFID small-size Tag antenna is for the Multipurpose Complex Card that is mounted on the fingerpring system as well as the HF Tag. It also enables to minimize and facilitates Tag chip matching by adjusting Tapered, Meander line and Loop structure. Given the card substance properties and periphery circuit, the proposed small-size Tag antenna, in this report, is designed with PET film with size of $50{\times}15mm^2$. The RFID small-size Tag method for measurements is used by EPCglobal Static Test instrument in Anechoic Chamber, which is tested with dual Card, within the car and in wallet. It is found that Read Range is 3.8m from the EPCglobal Static Test, Maximum Read Range within the car from the field test results in 7.6m. Proposed Tag antenna is will be used in the parking control security system.

Estimation of stream flow discharge using the satellite synthetic aperture radar images at the mid to small size streams (합성개구레이더 인공위성 영상을 활용한 중소규모 하천에서의 유량 추정)

  • Seo, Minji;Kim, Dongkyun;Ahmad, Waqas;Cha, Jun-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.12
    • /
    • pp.1181-1194
    • /
    • 2018
  • This study suggests a novel approach of estimating stream flow discharge using the Synthetic Aperture Radar (SAR) images taken from 2015 to 2017 by European Space Agency Sentinel-1 satellite. Fifteen small to medium sized rivers in the Han River basin were selected as study area, and the SAR satellite images and flow data from water level and flow observation system operated by the Korea Institute of Hydrological Survey were used for model construction. First, we apply the histogram matching technique to 12 SAR images that have undergone various preprocessing processes for error correction to make the brightness distribution of the images the same. Then, the flow estimation model was constructed by deriving the relationship between the area of the stream water body extracted using the threshold classification method and the in-situ flow data. As a result, we could construct a power function type flow estimation model at the fourteen study areas except for one station. The minimum, the mean, and the maximum coefficient of determination ($R^2$) of the models of at fourteen study areas were 0.30, 0.80, and 0.99, respectively.