• Title/Summary/Keyword: Maximum Current Density

Search Result 595, Processing Time 0.032 seconds

Span limit and parametric analysis of cable-stayed bridges

  • Zhao, Xinwei;Xiao, Rucheng;Sun, Bin
    • Structural Engineering and Mechanics
    • /
    • v.71 no.3
    • /
    • pp.271-282
    • /
    • 2019
  • The span record of cable-stayed bridges has exceeded 1,000 m, which makes research on the maximum possible span length of cable-stayed bridges an important topic in the engineering community. In this paper, span limit is discussed from two perspectives: the theoretical span limit determined by the strength-to-density ratio of the cable and girder, and the engineering span limit, which depends not only on the strength-to-density ratio of materials but also on the actual loading conditions. Closed form equations of both theoretical and engineering span limits of cable-stayed bridges determined by the cable and girder are derived and a detailed parametric analysis is conducted to assess the engineering span limit under current technical conditions. The results show that the engineering span limit of cable-stayed bridges is about 2,200 m based on materials used available today. The girder is the critical member restricting further increase in the span length; its compressive stress is the limiting factor. Approaches to increasing the engineering span limit are also presented based on the analysis results.

Analysis of Leakage Current Waveforms for Transmission Line Porcelain Insulators due to ESDD Contamination (ESDD 오손에 따른 송전용자기애자의 누설전류 파형의 분석)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1461-1470
    • /
    • 2012
  • This paper reports the contamination performance of transmission line porcelain insulators tested under five different contaminant conditions - clean and ESDD (equivalent salt deposit density) level (A, B, C, and D) through measurement of their leakage current under drop of potential method. To estimate the contamination for transmission line porcelain insulators, leakage current waveform and its maximum value were measured under step-up power test. In the clean insulators test, % distortion factors decreased with increasing step-up power, and as the ESDD level increased, some characteristics such as frequency analysis, harmonics and % distortion facotor could be used for contamination diagnosis of the transmission line porcelain insulators.

Transport Capacity Design and Characteristics Evaluation of Al/Cu Composite Busbar for Power Equipments (전력기기용 Al/Cu 복합 부스바의 통전용량 설계 및 특성 평가)

  • Bae, Joon-Han;Kim, Hae-Joon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.12
    • /
    • pp.628-632
    • /
    • 2006
  • This paper deals with the electric and thermal characteristics of the composite busbar composed of aluminum and copper. When AC current is flowing in Cu busbar used widely in conservative equipments like power cable, transformer, and switchgear & controlgear most current is concentrated on the surface of the busbar by the skin effect. Therefore, if the Cu region in the busbar having low current density is replaced with aluminum, we can largely reduce the product cost and weight of the busbar. To conform the performance of the composite busbar, we designed and fabricated a test Al/Cu composite busbar. Maximun temperature rise of the busbar was $35^{\circ}C$ when 1600 Arms of AC current was applied to the test composite busbar($120mm{\times}10mm$). Based on test results, we can expect to make the low-priced and light power equipments using the Al/Cu composite busbar.

Analyses on Current Densities Induced Inside a Worker Using AC Arc Welder (교류 아크용접기를 사용하는 작업자의 인체 유도전류밀도 해석)

  • Park, Jun-Hyeong;Min, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1410-1411
    • /
    • 2007
  • This paper analyses current densities induced inside a worker using AC arc welder. Applying the boundary element method, we calculate current densities induced in organs inside a worker in case he was located at 1[cm], 3[cm], 5[cm], 10[cm], 15[cm], 20[cm] far from a power cable of AC arc welder. As results of study, we find a maximum current density induces at a heart surface and may be higher than 10[$mA/m^2$] of ICNIRP guideline if he works within 15[cm] from a power cable.

  • PDF

Effect of Heat-Treatment on the Crystallization of B Powder and Critical Current Density Property of MgB2 Superconductor (보론 분말의 결정화에 대한 열처리 영향과 MgB2 초전도체의 임계전류밀도 특성)

  • You, Byung Youn;Kim, Chan-Joong;Park, Soon-Dong;Jun, Byung-Hyuk
    • Korean Journal of Materials Research
    • /
    • v.24 no.9
    • /
    • pp.465-468
    • /
    • 2014
  • The crystallization effects of boron (B) powder on the phase, full width at half maximum (FWHM) values, and critical properties were investigated for in-situ reacted $MgB_2$ bulk superconductors. The semi-crystalline B powder was heat-treated at different temperatures of 1000, 1300 and $1500^{\circ}C$ for 5 hours in an Ar atmosphere. Then, using as-received and heat-treated B powders, the $MgB_2$ samples were prepared at $600^{\circ}C$ for 40 hours in an Ar atmosphere. As the heat-treatment temperature of the B powder increased, both the particle size of the B powder and crystalline phase increased. In the case of $MgB_2$ samples using B powders heat-treated at above $1300^{\circ}C$, unreacted magnesium (Mg) and B remained due to the improved crystallinity of the B powder. As the heat-treatment temperature of B powder increased, the critical current density of $MgB_2$ decreased continuously due to the reduction of grain boundary density and superconducting volume caused by unreacted Mg and B.

A Study on the Effect of Coal Properties on the Electrochemical Reactions in the Direct Carbon Fuel Cell System (석탄 물성에 따른 직접탄소 연료전지의 전기화학 반응 특성 연구)

  • Ahn, Seong-Yool;Eom, Seong-Yong;Rhie, Young-Hoon;Moon, Cheor-Eon;Sung, Yon-Mo;Choi, Gyung-Min;Kim, Duck-Jool
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.10
    • /
    • pp.1033-1041
    • /
    • 2012
  • Performance evaluation of a direct carbon fuel cell (DCFC) was conducted according to coals and a graphite particle. Several fuel properties such as thermal reactivity, textural structure, gas adsorption characteristic, and functional groups on the surface of fuels were investigated and their effects on electrochemistry were discussed. The strong carbon structure inside of fuels led the rapid potential decreasing in high current density region, because it caused small surface area and low pore volume. The functional groups on the surface were related to the low current density region. The maximum current density and power density of fuels were affected by the total carbon content in fuels. The effect of operating conditions such as stirring rate and operating temperature was investigated in this study.

Video Image Analysis in Accordance with Power Density of Arcing for Current Collection System in Electric Railway (전기철도 집전장치의 아크량에 따른 비디오 이미지 분석)

  • Park, Young;Lee, Kiwon;Park, Chulmin;Kim, Jae-Kwang;Jeon, Ahram;Kwon, Sam-Young;Cho, Yong Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1343-1347
    • /
    • 2013
  • This paper presents an analysis methods for current collection quality in catenary system by means of video image based monitoring system. Arcing is the sparking at the interface point between pantograph and contact wire when the electric trains have traction current values at speed. Percentage of arcing at maximum line speed is measurable parameters for compliance with the requirements on dynamic behaviour of the interface between pantograph and contact wire in accordance with requirement of IEC and EN standards. The arc detector and video is installed on a train aim at the trailing contact strip according to the travel direction. The arc detector presented and measured verity of value such as the duration and power density of each arc and the video image is measured a image when the arc is occurred in pantograph. In this paper we analysis of video image in accordance with power density of arcing from arc detector and compared with video image and power density of arcing so as to produce quality of arcing from image.

Analytical Investigations on the Figures of Meander Lines on the YBCO Thin Film for Resistive Fault Current Limiters (YBCO 박막형 저항형 한류기에 적용 가능한 Meander Line 해석 연구)

  • 이방욱;강종성;박권배;오일성;현옥배
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.221-224
    • /
    • 2002
  • Superconducting electrical devices are under development in a national project in Korea. And KEPCO and LGIS are in charge of development of a resistive type fault current limiters(FCLs) with YBCO thin films. In order to realize FCLs, the rated power of FCLs must be increased. For this purpose, it is of great interest to increase of allowed voltage of unit component without electrical and thermal damages. So, meander lines were widely used for the conducting path to increase maximum electric field. In this research, numerical simulations on the electromagnetic behaviors of the device were carried out, especially focusing on the effect of meander line structures on the YBCO thin films. To evaluate the structures of meander lines, three types of meander lines were considered for numerical analysis using finite element method (FEM). In this simulation, both normal state and fault conditions were considered for calculation of electric field, current density, magnetic field density. And the simulation resulted are compared to find the optimum design of meander lines for resistive FCLs.

  • PDF

Mechanical Properties of Conductive Polymer as Actuator Materials with Change of Polymerization Condition (합성조건의 변화에 따른 액츄에이터 재료로서의 전도성 고분자의 기계적 특성)

  • Choi, Young;Lee, Seung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.6
    • /
    • pp.446-451
    • /
    • 1998
  • Recently, conductive polymer is known to be direct-drive active material which can convert electrical energy directly into mechanical energy. In this paper, the polymerized thickness of polypyrrole is measured with change of polymerization conditions and the mechanical bending is analyzed for various polymerized thickness. In order to detect of mechanical bending, bending beam method using the bridge shaped sample is used. Thickness of polypyrrole is proportional to polymerization time in fixed current density. Also it shows a linear relation with the applied current except high current density. Maximum displacement appears at the thickness of $18.35{\mu}m$ which has been polymerized at $5.4{\mu}A/mm^2$ and for 120min and actuated at the frequency of 0.1Hz.

  • PDF

A study on the magnetic properties of high Tc superconductor $Y_{1-x}Yb_xBa_2Cu_3FyOy$ (고온 초전도체 $Y_{1-x}Yb_xBa_2Cu_3FyOy$의 자기적 성질에 관한 연구)

  • 김재욱;김채옥
    • Electrical & Electronic Materials
    • /
    • v.9 no.6
    • /
    • pp.578-583
    • /
    • 1996
  • The magnetic properties have been investigated for the system of $Y_{1-x}$Yb$_{x}$Ba$_{2}$Cu$_{3}$F$_{y}$O$_{y}$ with x=0.0, 0.1, 0.2, 0.3, 0.4 and 0.5. In the magnetic hysteresis measurements, the values of the magnetic critical current densities are in the range of 10$^{4}$-10$^{5}$ A/cm$^{2}$ at the maximum external field 1.4 T. The upper critical field is over 100 T. The critical current density is estimated by the magnetization width .DELTA.M through the Bean critical state model. As the field strength is increased, the .DELTA.M diminishes slowly. The .DELTA.M for the fluorinated sample also decreases slowly with increasing field. It is considered that the large J, value results from this type is due to enhanced pinning center in grain boundary.y.ary.y.

  • PDF