Park, Chong Ook;Sa'aed, Noor Laith;Bayome, Mohamed;Park, Jae Hyun;Kook, Yoon-Ah;Park, Young-Seok;Han, Seong Ho
The korean journal of orthodontics
/
v.47
no.6
/
pp.375-383
/
2017
Objective: The purpose of this study was to evaluate the dental and skeletal effects of the modified C-palatal plate (MCPP) for total arch distalization in adult patients with Class II malocclusion and compare the findings with those of cervical pull headgear. Methods: The study sample consisted of the lateral cephalograms of 44 adult patients with Class II Division 1 malocclusion, including 22 who received treatment with MCPP (age, $24.7{\pm}7.7years$) and 22 who received treatment with cervical pull headgear (age, $23.0{\pm}7.7years$). Pre- (T1) and post-treatment (T2) cephalograms were analyzed for 24 linear and angular measurements. Multivariate analysis of variance was performed to evaluate the changes after treatment in each group and differences in treatment effects between the two groups. Results: The mean amount of distalization at the crown and root levels of the maxillary first molar and the amount of distal tipping was 4.2 mm, 3.5 mm, and $3.9^{\circ}$ in the MCPP group, and 2.3 mm, 0.6 mm, and $8.6^{\circ}$ in the headgear group, respectively. In addition, intrusion by 2.5 mm was observed in the MCPP group. In both groups, the distal movement of the upper lip and the increase in the nasolabial angle were statistically significant (p < 0.001). However, none of the skeletal and soft tissue variables exhibited significant differences between the two groups. Conclusions: The results of this study suggest that MCPP is an effective treatment modality for total arch distalization in adults.
Seo, Yun-Jin;Lee, Kwang-Hee;La, Ji-Young;An, So-Youn;Kim, Yun-Hee
Journal of the korean academy of Pediatric Dentistry
/
v.38
no.2
/
pp.137-145
/
2011
The purpose of this study was to obtain the data for dental caries experience and occlusal pattern to utilize these data for motivating oral health promotion and activating oral health care programme in preschool children of multicultural family. Caries prevalence on primary teeth was surveyed for 3-5 years old 190 children of multicultural families in Chonbuk province. The results were as follows : 1. Dental caries prevalence rate of primary teeth (dmf rate) was 61.7% at 3 years of age, 88.7% at 4 years of age, and 92.6% at 5 years of age (p>0.05). 2. Average score of dmft index was 2.22 at 3 years of age, 4.97 at 4 years of age, and 6.62 at 5 years of age (p>0.05). 3. Most of the caries-prevailed tooth was maxillary primary central incisor and showed 28.8% at 3 years of age, 56.7% at 5 years of age. 4. dmft index and dmfs index of children of Vietnamese, Cambodian, and Filipinos women were higher than those of Chinese and Japanese. 5. In sagittal primary molar relationship, flush terminal plane type was 82.6%, distal step type was 5.2% and mesial step type was 8.4%. This study is the first report for children of multicultural families in Korea. More attention for children of multicultural families will be needed in aspect of oral disease prevention and treatment.
Statement of problem: Injuries along with discomfort may result on the oral mucosa when non-rigid material is used as the major connector in construction of RPD, since nonrigid major connectors transmit unstable forces throughout the appliance. Titanium which recently draws attention as a substitute of Co-Cr had a difficulty in fabricating due to high melting temperature but the development of casting technique makes it possible to apply to the clinical case. Purpose: The purpose of this study was to investigate the rigidity and the castability of titanium upper major connector by design and make a comparison with Co-Cr major connectors which are widely used in clinical cases now. Material and methods: Casting was done using CP-Ti(Grage 2) (Kobe still Co., Japan) for the experimental groups, and 4 various designs namely palatal strap, U-shaped bar, A-P strap, and complete palatal plate were casted and 5 of each designs were included in each group. For the experimental group, Universal testing machine (Model 4502; Instron, Canton, Mass) was used to apply vertical torsional force vertically to the horizontal plane of major connector. In the second experiment, Vertical compressive force was applied to the horizontal plane of major connector. As a comparative group, Co-Cr major connector was equally manufactured and underwent the same experimental procedures Strain rate was measured after constant loading for one minute duration, and statistical analysis was done with SPSS ver.10.0 for WIN(SPSS. Inc. USA). From the one-way ANOVA and variance analysis (P=0.05), Scheffe's multiple comparison test implemented. Results: 1. Least amount of strain was observed with complete palatal plate followed by A-P bar, palatal bar, and the U-shaped bar having most amount of strain. 2. In all designs of titanium major connector, less strain rate was observed under compressive loading than under torsional loading showing more resistance to lateral force. 3. For titanium major connector, less strain rate was observed when the force is applied to the first premolar area rather than to the second molar area indicating more strength with shorter length of lever. 4. In Comparison of Co-Cr major connector with titanium major connector, palatal strap and U-shaped bar designs showed higher strength under torsional force that is statically significant, and under compressive force, no significant difference was observed expert for U-shaped bar. 5. In titanium major connector, complete palatal plate showed lowest success rate in casting when compared with the Co-Cr major connector. Conclusion: Above results prove that when using titanium for major connector, only with designs capable of generating rigidity can the major connector have almost equal amount of rigidity as Co-Cr major connector and show lower success rate in casting when compared with the Co-Cr major connector.
The purpose of this study was to investigate the pretreatment and posttreatment dentofacial characteristics of non-extraction patients with Class I malocclusion. And to compare this result with matched non-orthodontic normal occlusion and Class I premolar extraction patients. Such comparison might help identify morphologic characteristics of the non-extraction patients. Initial and final cephalometric evaluation were compared in a sample of 22 patients with Class I malocclusions treated in non-extraction manner with edgewise appliance and MEAW The mean age of the total population was 14 years 9 months and the average treatment time was 2 years 8 months. 32 landmarks were located and digitized on each cephalogram. From these landmarks, 24 linear and angular dimension were obtained. Student's t-test were used to compare the pretreatment - posttreatment results, Nonextraction - Normal groups, and nonextraction Extraction groups. Significance was predetermined at $p{\leq}0.05$. The results were as follows. 1. Before treatment, the mean value of the $ODI\;was\;69.9^{\circ},\;APDI\;was\;82.1^{\circ},\;CF\;was\;152^{\circ},\;EI\;was\;152^{\circ}$ in the non-extraction groups. 2. The skeletal pattern of the non-extraction groups were similar with non-orthodontic normal groupsr, but the non-extraction groups had larger interincisal angle. 3. Comparison between groups treated with and without extraction indicated at pretreatment, the extraction groups had more protrusive lips, smaller interincisal angle, and EI. 4. After treatment, there was no significant changes in the skeletal pattern of the non-extraction groups, but uprighting of the maxillary and mandibular first molar and decrease of the interincisal angle were seen.
Journal of the korean academy of Pediatric Dentistry
/
v.28
no.3
/
pp.355-362
/
2001
Data derived from odontometric studies are useful in many areas. Especially crown diameter of primary teeth is important in not only anthropology but also clinical dentistry. The purposes of this study were to compare diameters of primary molars of Korean children with those of preformed stainless steel crown, and examine racial characteristics of primary molars of Korean children. The mesiodistal and buccolingual diameters of primary molars were measured on dental casts taken from 235 children(male 105, female 131), with digital calipers. And the data were compared with those of preformed stainless steel crowns. The results were as follows; 1. No significant difference was observed between the right and left members of antimeric teeth and all primary molars of male were larger than those of female. 2. The diameters of primary molars of Korean are smaller than those of Austrailian aborigines and there was significant difference between diameters of primary molars of Korean and those of other populations. 3. There were size differences between diameters of maxillary, mandibular first molar and preformed stainless steel crown than other primary molars, relatively.
Kim Joong-hyun;Ryu Hak hyun;Lee Jae yeong;Han Kyu-bo;Kim So-seob;Kang Seong soo;Bae Chun sik;Choi Seok hwa
Journal of Veterinary Clinics
/
v.22
no.1
/
pp.31-35
/
2005
This study was performed to investigate of dental plaque, calculus and gingival inflammation in Beagle dogs. Forty adults Beagle dogs (28 male and 12 female) were used in this study. The dogs weighed 9.5 kg and were in good oral and systemic health as determined by physical examination, and all dogs had full and normal dentition. The dogs were given a commercial pellet feed during 2 years period. For all examination procedures, the dogs were premedicated with a subcutaneous injection of atropine sulfate (0.04 mg/kg). Anesthesia was induced and maintained by intravenous administration of ketamine (8 mg/kg) and xylazine (2 mg/kg). Dental plaque, calculus and gingival inflammation were assessed by Logan and Boyce clinical plaque index. Calculi covering the maxillary carnassial and first molar teeth were extensive and were accompanied by severe gingival inflammation and pocket formation. Calculi, accompanied by gingival inflammation, were clearly evident on buccal surfaces of other teeth. Calculi didn't showed on the lingual surfaces, but linguogingival inflammation formed in premolar teeth. Although the general pattern was clear, there was considerable variation among dogs in the rate of deposition of calculus and extend of gingival inflammation. This investigation suggest that feeding of the commercial dry food without dental hygiene increase plaque accumulation and may be a contributing factor in calculi formation and periodontal disease.
Kim, So-Yeun;Lee, So-Hyoun;Cho, Seong-Keun;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Mi-Jung;Huh, Jung-Bo
The Journal of Advanced Prosthodontics
/
v.6
no.1
/
pp.1-7
/
2014
PURPOSE. The accuracy of a gypsum model (GM), which was taken using a conventional silicone impression technique, was compared with that of a polyurethane model (PM), which was taken using an iTero$^{TM}$ digital impression system. MATERIALS AND METHODS. The maxillary first molar artificial tooth was selected as the reference tooth. The GMs were fabricated through a silicone impression of a reference tooth, and PMs were fabricated by a digital impression (n=9, in each group). The reference tooth and experimental models were scanned using a 3 shape convince$^{TM}$ scan system. Each GM and PM image was superimposed on the registered reference model (RM) and 2D images were obtained. The discrepancies of the points registered on the superimposed images were measured and defined as GM-RM group and PM-RM group. Statistical analysis was performed using a Student's T-test (${\alpha}=0.05$). RESULTS. A comparison of the absolute value of the discrepancy revealed a significant difference between the two groups only at the occlusal surface. The GM group showed a smaller mean discrepancy than the PM group. Significant differences in the GM-RM group and PM-RM group were observed in the margins (point a and f), mesial mid-axial wall (point b) and occlusal surfaces (point c and d). CONCLUSION. Under the conditions examined, the digitally fabricated polyurethane model showed a tendency for a reduced size in the margin than the reference tooth. The conventional gypsum model showed a smaller discrepancy on the occlusal surface than the polyurethane model.
Purpose: The purpose of this study is to compare the accuracy of the CT guided implant template that was produced by using an intraoral scanner according to the edentulous distance. Materials and methods: Five maxillary casts were fabricated using radiopaque acrylic resin with the second premolars, first molars, and second molars missing. Then a virtual cast was acquired by scanning each resin cast. Implant treatment was planned on the missing sites by superimposing the presurgical CT DICOM file and the virtual cast. Then the implants were placed using a surgical template followed by postsurgical CT scan. The distance and angle of the platform and apex between the presurgical implant and postsurgical implant were measured using the X, Y, and Z axis of the superimposed presurgical CT and postsurgical CT via software followed by statistical analysis using Kruskall-Wallis test and Mann-Whitney test. Results: The implant placement angle error increased towards the second molars but there was no statistically significant difference. The implant placement distance error at the platform and apex also increased towards the second molars and there was a statistically significant error at the second molars. Conclusion: Although the placement angle had no statistically significant difference between the presurgical implant and postsurgical implant, the placement distance at the platform and apex showed a larger error and a statistically significant difference at the second molar implant.
The purpose of this study was to observe the effect of dexamethasone and osteogenic protein-1(BMP-7) on bone, cementum and periodontal tissue regeneration. A total of 60 Sprague-Dawley white female mice were selected and beta-APN was used for five days to extract the maxillary first molar a traumatically. After the extraction of the teeth, the mesiobuccal root canal was filled with Caviton$^{\circledR}$. The teeth were etched with citric acid for 1 min and coated with one of four different experimental solutions : DEX(500nM/ml), DEX(1000nM/ml), OP-1(100$\mu\textrm{g}$/ml) and OP-1(500$\mu\textrm{g}$/ml) for three minutes depending on the group. All teeth were then replanted under microscope. All replantation procedures were done within 30 minutes. Teeth that were replanted after 30 minutes of bench dry only was used as positive control. All animals were sacrificed at 3 weeks following replantation and histologic observtion was done. The results were as follows ; 1. Active root resorption rate was decreased by the order of OP-1(500$\mu\textrm{g}$/ml), DEX(1000nM/ml), OP-1(100$\mu\textrm{g}$/ml), and DEX(500nM/ml). There was statistically less root resorption in OP-1 (500$\mu\textrm{g}$/ml) and DEX(1000nM/ml) group(P<0.05). 2. The group with higher concentration of dexamethasone(1000nM/ml) had statistically more bone union compared to positive control group(P<0.05),but there were no significant differences among four experimental groups. 3. OP-1(500$\mu\textrm{g}$/ml) and DEX(1000nM/ml) groups showed less degree of inflammation compared to the OP-1(100$\mu\textrm{g}$/ml). DEX(500nM/ml), and positive control group (P<0.05). In conclusion, the group with higher concentration of OP-1 had the best results on root resorption, bone ankylosis and anti-inflammatory effects compared to the other experimental groups, but a long-term study is also necessary to evaluate the exact pharmacological effects of the drugs in the future.
Kim, Chong-Myeong;Jeon, Jin-Hun;Lee, Jae-jun;Kim, Ji-Hwan;Kim, Woong-Chul
Journal of Technologic Dentistry
/
v.38
no.2
/
pp.57-62
/
2016
Purpose: The purpose of this study was to assess precision of crown prostheses that were fabricated by using 2 kinds of bur or 3 kinds of bur. Methods: The crowns were fabricated by using the first molar of the right maxillary in this study. The abutments that were prepared were scanned by using a scanner and designed by using CAD software. Based on the crown design, NC data were created with CAM software. The created NC data were used while fabricating the crown prostheses by using 5-axis milling machine. Scanning was done for the internal and external surface of the completed crown prostheses and 3-dimensional measurement was conducted for precision assessment. Results: The $RMS{\pm}SD$ value for the external surface of the crown prostheses that was fabricated by using two burs and three burs were $28.5{\pm}4.1{\mu}m$ and $19.1{\pm}2.8{\mu}m$, respectively; and the value for two burs were bigger than that for three burs with statistical significance (p<0.001). The $RMS{\pm}SD$ value for the internal surface of the crown prostheses that was fabricated by using two burs and three burs were $14.9{\pm}1.9{\mu}m$ and $13.3{\pm}2.5{\mu}m$, respectively; and the value for two burs were bigger than that for three burs but with no statistical significance. Conclusion: Based on this study, the prostheses that were fabricated by using 3 bur presented better stability compared to those that were fabricated by using 2 bur and statistically significant difference was found only in the external surface.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.