• Title/Summary/Keyword: Maxillary first molar

Search Result 354, Processing Time 0.03 seconds

Comparison of treatment effects between the modified C-palatal plate and cervical pull headgear for total arch distalization in adults

  • Park, Chong Ook;Sa'aed, Noor Laith;Bayome, Mohamed;Park, Jae Hyun;Kook, Yoon-Ah;Park, Young-Seok;Han, Seong Ho
    • The korean journal of orthodontics
    • /
    • v.47 no.6
    • /
    • pp.375-383
    • /
    • 2017
  • Objective: The purpose of this study was to evaluate the dental and skeletal effects of the modified C-palatal plate (MCPP) for total arch distalization in adult patients with Class II malocclusion and compare the findings with those of cervical pull headgear. Methods: The study sample consisted of the lateral cephalograms of 44 adult patients with Class II Division 1 malocclusion, including 22 who received treatment with MCPP (age, $24.7{\pm}7.7years$) and 22 who received treatment with cervical pull headgear (age, $23.0{\pm}7.7years$). Pre- (T1) and post-treatment (T2) cephalograms were analyzed for 24 linear and angular measurements. Multivariate analysis of variance was performed to evaluate the changes after treatment in each group and differences in treatment effects between the two groups. Results: The mean amount of distalization at the crown and root levels of the maxillary first molar and the amount of distal tipping was 4.2 mm, 3.5 mm, and $3.9^{\circ}$ in the MCPP group, and 2.3 mm, 0.6 mm, and $8.6^{\circ}$ in the headgear group, respectively. In addition, intrusion by 2.5 mm was observed in the MCPP group. In both groups, the distal movement of the upper lip and the increase in the nasolabial angle were statistically significant (p < 0.001). However, none of the skeletal and soft tissue variables exhibited significant differences between the two groups. Conclusions: The results of this study suggest that MCPP is an effective treatment modality for total arch distalization in adults.

A SURVEY ON DENTAL HEALTH OF CHILDREN OF MULTICULTURAL FAMILIES IN CHONBUK PROVINCE (전북지역 다문화가족 어린이의 구강건강 실태조사)

  • Seo, Yun-Jin;Lee, Kwang-Hee;La, Ji-Young;An, So-Youn;Kim, Yun-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.2
    • /
    • pp.137-145
    • /
    • 2011
  • The purpose of this study was to obtain the data for dental caries experience and occlusal pattern to utilize these data for motivating oral health promotion and activating oral health care programme in preschool children of multicultural family. Caries prevalence on primary teeth was surveyed for 3-5 years old 190 children of multicultural families in Chonbuk province. The results were as follows : 1. Dental caries prevalence rate of primary teeth (dmf rate) was 61.7% at 3 years of age, 88.7% at 4 years of age, and 92.6% at 5 years of age (p>0.05). 2. Average score of dmft index was 2.22 at 3 years of age, 4.97 at 4 years of age, and 6.62 at 5 years of age (p>0.05). 3. Most of the caries-prevailed tooth was maxillary primary central incisor and showed 28.8% at 3 years of age, 56.7% at 5 years of age. 4. dmft index and dmfs index of children of Vietnamese, Cambodian, and Filipinos women were higher than those of Chinese and Japanese. 5. In sagittal primary molar relationship, flush terminal plane type was 82.6%, distal step type was 5.2% and mesial step type was 8.4%. This study is the first report for children of multicultural families in Korea. More attention for children of multicultural families will be needed in aspect of oral disease prevention and treatment.

COMPARISON OF RIGIDITY AND CASTABILITY IN DIFFERENT DESIGNS OF MAXILLARY MAJOR TITANIUM FRAMEWORK (타이타늄 상악 주연결장치에 디자인에 따른 주조성 및 견고성 비교)

  • Lee, Young-Jae;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.431-443
    • /
    • 2007
  • Statement of problem: Injuries along with discomfort may result on the oral mucosa when non-rigid material is used as the major connector in construction of RPD, since nonrigid major connectors transmit unstable forces throughout the appliance. Titanium which recently draws attention as a substitute of Co-Cr had a difficulty in fabricating due to high melting temperature but the development of casting technique makes it possible to apply to the clinical case. Purpose: The purpose of this study was to investigate the rigidity and the castability of titanium upper major connector by design and make a comparison with Co-Cr major connectors which are widely used in clinical cases now. Material and methods: Casting was done using CP-Ti(Grage 2) (Kobe still Co., Japan) for the experimental groups, and 4 various designs namely palatal strap, U-shaped bar, A-P strap, and complete palatal plate were casted and 5 of each designs were included in each group. For the experimental group, Universal testing machine (Model 4502; Instron, Canton, Mass) was used to apply vertical torsional force vertically to the horizontal plane of major connector. In the second experiment, Vertical compressive force was applied to the horizontal plane of major connector. As a comparative group, Co-Cr major connector was equally manufactured and underwent the same experimental procedures Strain rate was measured after constant loading for one minute duration, and statistical analysis was done with SPSS ver.10.0 for WIN(SPSS. Inc. USA). From the one-way ANOVA and variance analysis (P=0.05), Scheffe's multiple comparison test implemented. Results: 1. Least amount of strain was observed with complete palatal plate followed by A-P bar, palatal bar, and the U-shaped bar having most amount of strain. 2. In all designs of titanium major connector, less strain rate was observed under compressive loading than under torsional loading showing more resistance to lateral force. 3. For titanium major connector, less strain rate was observed when the force is applied to the first premolar area rather than to the second molar area indicating more strength with shorter length of lever. 4. In Comparison of Co-Cr major connector with titanium major connector, palatal strap and U-shaped bar designs showed higher strength under torsional force that is statically significant, and under compressive force, no significant difference was observed expert for U-shaped bar. 5. In titanium major connector, complete palatal plate showed lowest success rate in casting when compared with the Co-Cr major connector. Conclusion: Above results prove that when using titanium for major connector, only with designs capable of generating rigidity can the major connector have almost equal amount of rigidity as Co-Cr major connector and show lower success rate in casting when compared with the Co-Cr major connector.

THE MORPHOLOGIC CHARACTERISTICS OF CLASS I, NON-EXTRACTION PATIENTS (비발치로 치료된 I 급 부정교합의 형태적 특성)

  • Chang, Young-Il;Shin, Soo-Jung
    • The korean journal of orthodontics
    • /
    • v.28 no.3 s.68
    • /
    • pp.343-351
    • /
    • 1998
  • The purpose of this study was to investigate the pretreatment and posttreatment dentofacial characteristics of non-extraction patients with Class I malocclusion. And to compare this result with matched non-orthodontic normal occlusion and Class I premolar extraction patients. Such comparison might help identify morphologic characteristics of the non-extraction patients. Initial and final cephalometric evaluation were compared in a sample of 22 patients with Class I malocclusions treated in non-extraction manner with edgewise appliance and MEAW The mean age of the total population was 14 years 9 months and the average treatment time was 2 years 8 months. 32 landmarks were located and digitized on each cephalogram. From these landmarks, 24 linear and angular dimension were obtained. Student's t-test were used to compare the pretreatment - posttreatment results, Nonextraction - Normal groups, and nonextraction Extraction groups. Significance was predetermined at $p{\leq}0.05$. The results were as follows. 1. Before treatment, the mean value of the $ODI\;was\;69.9^{\circ},\;APDI\;was\;82.1^{\circ},\;CF\;was\;152^{\circ},\;EI\;was\;152^{\circ}$ in the non-extraction groups. 2. The skeletal pattern of the non-extraction groups were similar with non-orthodontic normal groupsr, but the non-extraction groups had larger interincisal angle. 3. Comparison between groups treated with and without extraction indicated at pretreatment, the extraction groups had more protrusive lips, smaller interincisal angle, and EI. 4. After treatment, there was no significant changes in the skeletal pattern of the non-extraction groups, but uprighting of the maxillary and mandibular first molar and decrease of the interincisal angle were seen.

  • PDF

A MORPHOMETRIC STUDY ON THE PRIMARY MOLARS AND PREFORMED STAINLESS STEEL CROWN (유구치 치관 및 기성금속관의 크기에 관한 계측학적 연구)

  • Choi, Ji-Eun;Cheong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.355-362
    • /
    • 2001
  • Data derived from odontometric studies are useful in many areas. Especially crown diameter of primary teeth is important in not only anthropology but also clinical dentistry. The purposes of this study were to compare diameters of primary molars of Korean children with those of preformed stainless steel crown, and examine racial characteristics of primary molars of Korean children. The mesiodistal and buccolingual diameters of primary molars were measured on dental casts taken from 235 children(male 105, female 131), with digital calipers. And the data were compared with those of preformed stainless steel crowns. The results were as follows; 1. No significant difference was observed between the right and left members of antimeric teeth and all primary molars of male were larger than those of female. 2. The diameters of primary molars of Korean are smaller than those of Austrailian aborigines and there was significant difference between diameters of primary molars of Korean and those of other populations. 3. There were size differences between diameters of maxillary, mandibular first molar and preformed stainless steel crown than other primary molars, relatively.

  • PDF

Investigation of Dental Plaque, Calculus and Gingival Inflammation in Beagle Dogs (비글견에서 치태와 치석, 치은 염증의 조사)

  • Kim Joong-hyun;Ryu Hak hyun;Lee Jae yeong;Han Kyu-bo;Kim So-seob;Kang Seong soo;Bae Chun sik;Choi Seok hwa
    • Journal of Veterinary Clinics
    • /
    • v.22 no.1
    • /
    • pp.31-35
    • /
    • 2005
  • This study was performed to investigate of dental plaque, calculus and gingival inflammation in Beagle dogs. Forty adults Beagle dogs (28 male and 12 female) were used in this study. The dogs weighed 9.5 kg and were in good oral and systemic health as determined by physical examination, and all dogs had full and normal dentition. The dogs were given a commercial pellet feed during 2 years period. For all examination procedures, the dogs were premedicated with a subcutaneous injection of atropine sulfate (0.04 mg/kg). Anesthesia was induced and maintained by intravenous administration of ketamine (8 mg/kg) and xylazine (2 mg/kg). Dental plaque, calculus and gingival inflammation were assessed by Logan and Boyce clinical plaque index. Calculi covering the maxillary carnassial and first molar teeth were extensive and were accompanied by severe gingival inflammation and pocket formation. Calculi, accompanied by gingival inflammation, were clearly evident on buccal surfaces of other teeth. Calculi didn't showed on the lingual surfaces, but linguogingival inflammation formed in premolar teeth. Although the general pattern was clear, there was considerable variation among dogs in the rate of deposition of calculus and extend of gingival inflammation. This investigation suggest that feeding of the commercial dry food without dental hygiene increase plaque accumulation and may be a contributing factor in calculi formation and periodontal disease.

Comparison of the accuracy of digitally fabricated polyurethane model and conventional gypsum model

  • Kim, So-Yeun;Lee, So-Hyoun;Cho, Seong-Keun;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • PURPOSE. The accuracy of a gypsum model (GM), which was taken using a conventional silicone impression technique, was compared with that of a polyurethane model (PM), which was taken using an iTero$^{TM}$ digital impression system. MATERIALS AND METHODS. The maxillary first molar artificial tooth was selected as the reference tooth. The GMs were fabricated through a silicone impression of a reference tooth, and PMs were fabricated by a digital impression (n=9, in each group). The reference tooth and experimental models were scanned using a 3 shape convince$^{TM}$ scan system. Each GM and PM image was superimposed on the registered reference model (RM) and 2D images were obtained. The discrepancies of the points registered on the superimposed images were measured and defined as GM-RM group and PM-RM group. Statistical analysis was performed using a Student's T-test (${\alpha}=0.05$). RESULTS. A comparison of the absolute value of the discrepancy revealed a significant difference between the two groups only at the occlusal surface. The GM group showed a smaller mean discrepancy than the PM group. Significant differences in the GM-RM group and PM-RM group were observed in the margins (point a and f), mesial mid-axial wall (point b) and occlusal surfaces (point c and d). CONCLUSION. Under the conditions examined, the digitally fabricated polyurethane model showed a tendency for a reduced size in the margin than the reference tooth. The conventional gypsum model showed a smaller discrepancy on the occlusal surface than the polyurethane model.

Accuracy of the CT guided implant template by using an intraoral scanner according to the edentulous distance (구강스캐너를 이용하여 제작된 CT 가이드 임플란트 수술용 형판의 무치악 거리에 따른 정확도 분석)

  • Kang, Byeong-Gil;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Purpose: The purpose of this study is to compare the accuracy of the CT guided implant template that was produced by using an intraoral scanner according to the edentulous distance. Materials and methods: Five maxillary casts were fabricated using radiopaque acrylic resin with the second premolars, first molars, and second molars missing. Then a virtual cast was acquired by scanning each resin cast. Implant treatment was planned on the missing sites by superimposing the presurgical CT DICOM file and the virtual cast. Then the implants were placed using a surgical template followed by postsurgical CT scan. The distance and angle of the platform and apex between the presurgical implant and postsurgical implant were measured using the X, Y, and Z axis of the superimposed presurgical CT and postsurgical CT via software followed by statistical analysis using Kruskall-Wallis test and Mann-Whitney test. Results: The implant placement angle error increased towards the second molars but there was no statistically significant difference. The implant placement distance error at the platform and apex also increased towards the second molars and there was a statistically significant error at the second molars. Conclusion: Although the placement angle had no statistically significant difference between the presurgical implant and postsurgical implant, the placement distance at the platform and apex showed a larger error and a statistically significant difference at the second molar implant.

THE EFFECT OF PERIODONTAL REGENERATION AND ANTI-RESTORATION OF DEXAMETHASONE AND OP-1 FOLLOWING DELAYED REPLANTATION IN RAT MODEL (흰 쥐 모델에서 지연재식 시 dexamethasone과 OP-1의 표면처리가 치주조직 재생 및 항흡수 작용에 미치는 효과)

  • Kwon, O-Taek;Kum, Kee-Yeon;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.296-306
    • /
    • 2001
  • The purpose of this study was to observe the effect of dexamethasone and osteogenic protein-1(BMP-7) on bone, cementum and periodontal tissue regeneration. A total of 60 Sprague-Dawley white female mice were selected and beta-APN was used for five days to extract the maxillary first molar a traumatically. After the extraction of the teeth, the mesiobuccal root canal was filled with Caviton$^{\circledR}$. The teeth were etched with citric acid for 1 min and coated with one of four different experimental solutions : DEX(500nM/ml), DEX(1000nM/ml), OP-1(100$\mu\textrm{g}$/ml) and OP-1(500$\mu\textrm{g}$/ml) for three minutes depending on the group. All teeth were then replanted under microscope. All replantation procedures were done within 30 minutes. Teeth that were replanted after 30 minutes of bench dry only was used as positive control. All animals were sacrificed at 3 weeks following replantation and histologic observtion was done. The results were as follows ; 1. Active root resorption rate was decreased by the order of OP-1(500$\mu\textrm{g}$/ml), DEX(1000nM/ml), OP-1(100$\mu\textrm{g}$/ml), and DEX(500nM/ml). There was statistically less root resorption in OP-1 (500$\mu\textrm{g}$/ml) and DEX(1000nM/ml) group(P<0.05). 2. The group with higher concentration of dexamethasone(1000nM/ml) had statistically more bone union compared to positive control group(P<0.05),but there were no significant differences among four experimental groups. 3. OP-1(500$\mu\textrm{g}$/ml) and DEX(1000nM/ml) groups showed less degree of inflammation compared to the OP-1(100$\mu\textrm{g}$/ml). DEX(500nM/ml), and positive control group (P<0.05). In conclusion, the group with higher concentration of OP-1 had the best results on root resorption, bone ankylosis and anti-inflammatory effects compared to the other experimental groups, but a long-term study is also necessary to evaluate the exact pharmacological effects of the drugs in the future.

  • PDF

Precision evaluation of crown prosthesis manufactured by two bur and three bur (2종류의 버와 3종류의 버를 이용해 제작된 크라운 보철물의 정밀도 평가)

  • Kim, Chong-Myeong;Jeon, Jin-Hun;Lee, Jae-jun;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.38 no.2
    • /
    • pp.57-62
    • /
    • 2016
  • Purpose: The purpose of this study was to assess precision of crown prostheses that were fabricated by using 2 kinds of bur or 3 kinds of bur. Methods: The crowns were fabricated by using the first molar of the right maxillary in this study. The abutments that were prepared were scanned by using a scanner and designed by using CAD software. Based on the crown design, NC data were created with CAM software. The created NC data were used while fabricating the crown prostheses by using 5-axis milling machine. Scanning was done for the internal and external surface of the completed crown prostheses and 3-dimensional measurement was conducted for precision assessment. Results: The $RMS{\pm}SD$ value for the external surface of the crown prostheses that was fabricated by using two burs and three burs were $28.5{\pm}4.1{\mu}m$ and $19.1{\pm}2.8{\mu}m$, respectively; and the value for two burs were bigger than that for three burs with statistical significance (p<0.001). The $RMS{\pm}SD$ value for the internal surface of the crown prostheses that was fabricated by using two burs and three burs were $14.9{\pm}1.9{\mu}m$ and $13.3{\pm}2.5{\mu}m$, respectively; and the value for two burs were bigger than that for three burs but with no statistical significance. Conclusion: Based on this study, the prostheses that were fabricated by using 3 bur presented better stability compared to those that were fabricated by using 2 bur and statistically significant difference was found only in the external surface.