• Title/Summary/Keyword: Matrices

Search Result 2,647, Processing Time 0.024 seconds

Development of Case-based Quality Management System improvement Methodology for Defence Suppliers (중소 방산업체를 위한 사례기반 품질경영시스템 개선 방법론 개발)

  • Choi, Jae-Ho;Ahn, Jong-Moo;Lee, Hee-Rang;Kang, Gu-Heon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.55-67
    • /
    • 2018
  • The Korean defence industry has grown rapidly since the 1970s. In 2015, it generated more than 168 billion won in economic revenue, and exports exceeded 3.6 billion won. With the development of the defense industry, the level of the quality management system for major contractors has improved substantially, but there are many areas of the quality management system that still need improvement for small subcontractors. Therefore, in this paper, we develop a methodology to improve the quality management system for small subcontractors. Based on 101 collected cases, this methodology results in generally improved effects and generally improved methods. By applying the Russian Theory of Inventive Problem Solving (TRIZ) concept of a contradiction matrix, three improvement matrices are derived. A developed improvement matrix is the main support tool of this methodology. This methodology consists of four tasks and eight subtasks, and it can be used as a support tool for creative problem solving by the quality assurance department and the quality assurance manager for small subcontractors.

A Study for Individual Identification by Discriminating the Finger Face Image (손가락 면 영상 판별에 의한 개인 식별 연구)

  • Kim, Hee-Sung;Bae, Byung-Kyu
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.3
    • /
    • pp.378-391
    • /
    • 2010
  • In this paper, it is tested that an individual is able to be identified with finger face images and the results are presented. Special operators, FFG(Facet Function Gradient) masks by which the gradient of a facet function fit on a gray levels of image patches can be computed are used and a new procedure named F-algorithm is introduced to match the finger face images. The finger face image is divided into the equal subregions and each subregions are divided into equal patches with this algorithm. The FFG masks are used for convolution operation over each patch to produce scalar values. These values from a feature matrix, and the identity of fingers is determined by a norm of the elements of the feature matrices. The distribution of the norms shows conspicuous differences between the pairs of hand images of the same persons and the pairs of the different persons. This is a result to prove the ability of discrimination with the finger face image. An identification rate of 95.0% is obtained as a result of the test in which 500 hand images taken from 100 persons are processed through F-algorithm. It is affirmed that the finger face reveals to be such a good biometrics as other hand parts owing to the ability of discrimination and the identification rate.

Interference Alignment in 2-user X Channel System with Orthogonal and quasi-orthogonal Space-time Block Codes (직교 및 준직교 시공간 블록 부호를 통한 2-사용자 X 채널에서의 간섭정렬)

  • Mohaisen, Islam;Lee, Saet-byeol;Mohaisen, Manar;Elaydi, Hatem
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.8
    • /
    • pp.1785-1796
    • /
    • 2015
  • In this paper, we investigate achieving the full diversity order and power gains in case of using OSTBCs and quasi-OSBCs in the x channel system with interference alignment with more than 2 antennas at each terminal. A slight degradation is remarked in the case of quasi-OSTBCs. In terms of receiver structure, we show that due to the favorable structure of the channel matrices, the simple zero-forcing receiver achieves the full diversity order, while the interference cancellation receiver leads to degradations in performance. As compared to the conventional scheme, simulation results demonstrate that our proposed schemes achieve 14dB and 16.5dB of gain at a target bit error rate (BER) of 10-4 in the case of OSTBCs with 3 and 4 antennas at each terminal, respectively, while achieving the same spectral efficiency. Also, a gain of 10dB is achieved at the same target BER in the case of quasi-OSTBC with 4 antennas at each terminal.

EFFECT OF RESIN MATRIX ON DEGREE OF CONVERSION AND FRACTURE TOUGHNESS OF DENIAL COMPOSITES (기질레진의 조성에 따른 복합레진의 물리적 성질에 관한 연구)

  • Lee, Yun-Shin;Choi, Kyoung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.1
    • /
    • pp.77-86
    • /
    • 2002
  • Current composites are made with dimethacrylate monomers and silane-treated silica microfillers, either alone or with silane treated glass fillers The main reasons for clinical failure of dental composites are secondary caries, wear and fracture. Most of practitioner want to get a composite which is more tougher under occlusal stress, less polymerization contraction, and better handling properties in application clinically. The aim of this study was to investigate the influence of resin matrix with various flows on the physical proper-ties such as fracture toughness and degree of conversion of the experimental resins. It was hypothesized that flexible or tough resin composites can be designed by judicious choice of monomer composition Various flow resin matrices containing Bis-GMA, UDMA, and TEG-DMA were made by altering the pro-portion of the monomers. After the unfilled resins were light-cured for different light intensity, the fracture toughness(K$_{1c}$) was measured according to ASTM standard using the single edge notched geometry, and degree of conversion(DC) was measured by FTIR. And experimental composites were formulated with variations in the proportion of silanated quartz and strontium glass fillers as 60, 75, and 77wt%. Also, the physical properties of composites with various filer contents were evaluated as same manner. All resulting data were compared by ANOVA/Tukeys test at 0.05 level. The results were as follows; 1. The degree of conversion of high flow resin containing less Bis-GMA was higher than that of low flow unfilled resin 2. While the degree of conversion of unfilled resin was increased according to light intensity for polymerization, there was no significant increase with moderate and high light intensity. Also, the fracture toughness was not increased by high light intensity. 3. The fracture toughness was high in the low flow unfilled resin containing higher contents of Bis-GMA. 4. There was a significant increase for fracture toughness and a tendency for degree of conversion to be reduced when the content of fillers was increased. 5. In the experimental composites, the flow of resin matrix did not affected on the fracture toughness, even, which was decreased as increase of viscosity. These results showed that the physical properties of a dental composite could be attributed to the flow of resin matrix with relative content of monomers. Specific combination of resin monomers should be designed to fulfil the needs of specific indication for use.

Mechanical Properties of Strain Hardening Cement-Based Composite (SHCC) with Recycled Materials (자원순환형 재료를 사용한 변형경화형 시멘트 복합체(SHCC)의 역학적 특성)

  • Kim, Sun-Woo;Cha, Jun-Ho;Kim, Yun-Yong;Yun, Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.5
    • /
    • pp.727-736
    • /
    • 2010
  • This paper describes results of an preliminary study to produce strain hardening cement-based composites (SHCCs)with consideration of sustainability for infrastructure applications. The aims of this study are to evaluate the influence of recycled materials on the mechanical characteristics of SHCCs, such as compressive, four-point bending, and direct tensile behaviors, and to give basic data for constitutive model for analyzing and designing infra structures with SHCCs. In this study, silica sand, cement, and PVA fibers, were partially replaced with recycled sand, fly-ash, and FET fibers in the mixture of SHCCs, respectively. Test results indicated that fly-ash could improve both bending and direct tensile performance of SHCCs due to increasing chemical bond strength at the interface between PVA fibers and cement matrices. However, SHCCs replaced with PET fibers showed much lower performance in bending and direct tensile tests due to originally low mechanical properties of own fibers, although compressive behavior is similar to PVA2.0 specimen. Also, it was noted that the recycled sand would increase elastic modulus of SHCCs due to larger grain size compared to silica sand. Based on pre-set target value to maintain the performance of SHCCs, it was concluded that the replacement ratio below 20% of fly-ash or below 50% of recycled sands would be desirable for creating sustainable SHCCs.

Water-insoluble, Whey Protein-based Microcapsules for Controlled Core Release Application (유청단백질을 이용한 미세캡슐의 응용)

  • Lee, Sung-Je
    • 한국유가공학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.37-61
    • /
    • 2005
  • Microcapsules consisting of natural, biodegradable polymers for controlled and/or sustained core release applications are needed. Physicochemical properties of whey proteins suggest that they may be suitable wall materials in developing such microcapsules. The objectives of the research were to develop water-insoluble, whey protein-based microcapsules containing a model water-soluble drug using a chemical cross-linking agent, glutaraldehyde, and to investigate core release from these capsules at simulated physiological conditions. A model water soluble drug, theophylline, was suspended in whey protein isolate (WPI) solution. The suspension was dispersed in a mixture of dichloromethane and hexane containing 1% biomedical polyurethane. Protein matrices were cross-linked with 7.5-30 ml of glutaraldehyde-saturated toluene (GAST) for 1-3 hr. Microcapsules were harvested, washed, dried and analyzed for core retention, microstructure, and core release in enzyme-free simulated gastric fluid (SGF) and simulated intestinal fluid (SIF) at 37$^{\circ}C$, A method consisting of double emulsification and heat gelation was also developed to prepare water-insoluble, whey protein-based microcapsules containing anhydrous milkfat (AMF) as a model apolar core. AMF was emulsified into WPI solution (15-30%, pH 4.5-7.2) at a proportion of 25-50% (w/w, on dry basis). The oil-in-water emulsion was then added and dispersed into corn oil (50 $^{\circ}C$)to form an O/W/O double emulsion and then heated at 85$^{\circ}C$ for 20 min for gelation of whey protein wall matrix. Effects of emulsion composition and pH on core retention, microstructure, and water-solubility of microcapsules were determined. Overall results suggest that whey proteins can be used in developing microcapsules for controlled and sustained core release applications.

  • PDF

Prediction of Genomic Relationship Matrices using Single Nucleotide Polymorphisms in Hanwoo (한우의 유전체 표지인자 활용 개체 혈연관계 추정)

  • Lee, Deuk-Hwan;Cho, Chung-Il;Kim, Nae-Soo
    • Journal of Animal Science and Technology
    • /
    • v.52 no.5
    • /
    • pp.357-366
    • /
    • 2010
  • The emergence of next-generation sequencing technologies has lead to application of new computational and statistical methodologies that allow incorporating genetic information from entire genomes of many individuals composing the population. For example, using single-nucleotide polymorphisms (SNP) obtained from whole genome amplification platforms such as the Ilummina BovineSNP50 chip, many researchers are actively engaged in the genetic evaluation of cattle livestock using whole genome relationship analyses. In this study, we estimated the genomic relationship matrix (GRM) and compared it with one computed using a pedigree relationship matrix (PRM) using a population of Hanwoo. This project is a preliminary study that will eventually include future work on genomic selection and prediction. Data used in this study were obtained from 187 blood samples consisting of the progeny of 20 young bulls collected after parentage testing from the Hanwoo improvement center, National Agriculture Cooperative Federation as well as 103 blood samples from the progeny of 12 proven bulls collected from farms around the Kyong-buk area in South Korea. The data set was divided into two cases for analysis. In the first case missing genotypes were included. In the second case missing genotypes were excluded. The effect of missing genotypes on the accuracy of genomic relationship estimation was investigated. Estimation of relationships using genomic information was also carried out chromosome by chromosome for whole genomic SNP markers based on the regression method using allele frequencies across loci. The average correlation coefficient and standard deviation between relationships using pedigree information and chromosomal genomic information using data which was verified using a parentage test andeliminated missing genotypes was $0.81{\pm}0.04$ and their correlation coefficient when using whole genomic information was 0.98, which was higher. Variation in relationships between non-inbred half sibs was $0.22{\pm}0.17$ on chromosomal and $0.22{\pm}0.04$ on whole genomic SNP markers. The variations were larger and unusual values were observed when non-parentage test data were included. So, relationship matrix by genomic information can be useful for genetic evaluation of animal breeding.

Microstructural Changes during Tempering Treatment of Nitrogen-permeated STS 410 and 410L Martensitic Stainless Steels (질소침투 열처리한 STS 410 및 410L 마르텐사이트계 스테인리스강의 템퍼링에 의한 조직변화)

  • Lee, Hea Joeng;Kong, Jung Hyun;Lee, Hae Woo;Yu, Dea Kyung;Kang, Chang Yong;Sung, Jang Hyun
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.20 no.2
    • /
    • pp.84-93
    • /
    • 2007
  • Microstructural changes during tempering at the temperature range of $300^{\circ}C{\sim}700^{\circ}C$ for the nitrogen-permeated STS 410 and 410L martensitic stainless steels has been investigated. After nitrogen permeation at temperature between 1050 and $1150^{\circ}C$, the surface layer appeared fine $Cr_2N$ of square and rod types in the martensite matrices. Hardness of the nitrogen-permeated surface layer represented 680Hv and 625Hv, respectively, for 410 and 410L steels. It is considered that the fine homogeneously dispersive effect of precipitates by nitrogen caused the increased hardness. Due to the counter current effect of carbon from interior to surface during nitrogen diffusion from surface to interior, the 0.1%C alloyed 410 steel showed the low nitrogen content of 0.025% compared with 0.045% of 410L steel at the distance of $100{\mu}m$ from the surface. Tempering of nitrogen-alloyed 410 and 410L showed the maximum hardness at $450^{\circ}C$. This maximum hardness was considered to be the secondary hardening effect of very fine carbide and nitride. The decrease in hardness at $700^{\circ}C$ was the softening effect of the matrix due to the precipitation of many needle-shaped $Cr_2N$ for 410 steel and the precipitation of coarse nitride of $Cr_2N$ in line with the spherical precipitates with directionality for 410L steel. For 410 steel, the corrosion resistance of nitrogen permeated surface in the solution of 1 N $H_2SO_4$ were nearly unchanged, however the superior corrosion resistance was obtained for nitrogen permeated 410L steel compared to the solution annealed condition.

Simultaneous Determination of Octylphenol, Nonylphenol and Bis(2-ethylhexyl)phthalate in Fish Samples Using Two Internal Standards (2가지 내부표준물질을 이용하여 어류시료 중 Octylphenol, Nonylphenol, Bis(2-ethylhexyl)phehalate의 동시정량)

  • Kim, Jong-Hun
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.244-252
    • /
    • 2001
  • A comprehensive analytical method of endocrine distruptors[i.e., nonylphenol(NP), octylphenol(OP), bis(2-ethylhexyl)phthalate(BEHP)] is fish samples was developed using two internal standards. This method employed closed culture tube extraction with dichloromethane and solvent exchange to iso-hexane and SPE(2g) aminopropyl column, followed by determination on gas chromatograph linked to mass spectrometer(GC/MS) operated in the single ion monitoring(SIM) mode. The recoveries of nonylphenol and octyphenol in the range of $0.2{\sim}20{\mu}g/g$ using 1-phenyl decanol as one internal standard were over 75%, and recovery of bis(2-ethylhexyl)phthalate in the range of $0.4{\sim}40{\mu}g/g$ using bis(2-ethylbutyl)phthalate(BEBP) as the other internal standards was showed over 102%. The present method was applied to fish samples from Korea and UK. The range of concentrations for nonylphnol(NP) and bis(2-ethylhexyl)phthalate in Korean fish were $0.02{\sim}0.06{\mu}g/g$ in 2 samples and $0.18{\sim}2.03{\mu}g/g$ in 9 samples respectively, but bis(2-ethylhexyl)phthalate(BEHP) in UK samples was found $2.99{\mu}g/g$ in just 1 sample. But octylphenol(OP) was not dected in any samples by this method. This two internal standard method provides a more precise analytical tool to investigate endocrine disruptors in a biological matrices of limited quantity.

  • PDF

Ultrastructural Changes of the Renal Corpuscle of the Mouse with Age (노화에 따른 마우스 콩팥소체의 미세구조 변화)

  • Ko, Jeong-Sik;Park, Sook-Hyun;Ahn, E-Tay;Park, Kyung-Ho;Kim, Jin-Gook
    • Applied Microscopy
    • /
    • v.27 no.4
    • /
    • pp.373-389
    • /
    • 1997
  • Morphological difference of the renal glomerulus at different age groups have been studies in one week-old, five weeks-old, eight weeks-old, six months-old, twelve months-old, eighteen months-old, twenty-four months-old, and thirty months-old ICR mice. Pieces of the tissue taken from the renal corticies were fixed in 2.5% glutaraldehyde-1.5% paraformaldehyde solution (0.1 Millonig's phosphate buffer pH 7.3), and 1% osmium tetroxide solution (0.1 M Millonig's phosphate buffer, pH 7.3), and were embedded in araldite mixture. The ultrathin sections were stained with uranyl acetate and lead citrate solution, and were observed under a JEM 100CX-II electron microscope. The results were as follows: 1 In the one week-old mouse, thicknesses of the three layers of the glomeluar basal lamina (lamina densa, lamina rara interna and lamina rara externa) are similar, but in the five weeks-old mouse, thick lamina densa becomes a greater portion of the thickness of whole glomerular basal lamina. 2. No difference was noticed between thickness of the renal glomerular basal lamina of the five weeks-old mouse compare with that of the one week-old one, but basal lamina of the eight weeks-old one is thickened considerably and thicknesses were maintained through twelve months-old one. After eighteen months, the thickness of the glomerular basal lamina is increased remarkably. 3. After eighteen months, electron dense deposits within the basal lamina of the renal glomeruli are observed frequently. 4. Amount of the microfilaments in the mesangial cells and the mesangial matrices are increasing during aging. 5. The thicknesses of the basal laminae of the Bowman's capsule are increasing during aging. 6. After twenty four months, the proximal tubular cell-like parietal cells with well developed microvilli are observed frequently. From the above results, it was suggested that the renal glomerulus matures structurally in five weeks, and the function of the glomerulus is suppressed after eighteen months.

  • PDF