• Title/Summary/Keyword: Material Stretching

Search Result 180, Processing Time 0.023 seconds

Improvement research for impact strength of nylon66/silicate composites (나일론66/실리케이트 복합체의 충격특성 개선 연구)

  • Lee, Bom Yi;Kim, Youn Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4653-4658
    • /
    • 2014
  • A study of the improvement in the impact strength is required to apply Nylon 66/silicate composites as an automobile material. Nylon 66/silicate composites were prepared using a twin screw extruder in case of a silicate treatment by ${\gamma}$-APS (S-silicate) and the addition of an octene ${\alpha}$ olefin grafted by maleic anhydride (PE-g-MAH). The chemical structure of the silane treated silicate was measured by Fourier transform infra-red (FT-IR) spectroscopy. The chemical reaction was confirmed by the decrease in the FT-IR intensity of the OH stretching vibration. The thermal properties, intercalation structure, and Izod impact strength were measured by DSC, TGA, XRD, and Izod impact tester. There was no significant effect on the degradation temperature of the Nylon66/silicate composite, but the crystallization temperature and crystallinity increased slightly in the case of the Nylon66/silicate composites. This suggests that the additives act as heterogeneous nuclei on the Nylon 66 matrix. The Izod impact test indicated that S-silicate enhanced the impact performance by up to 24%.

Evaluation of the Septic Tank Performance in the Sewage Treatment Area and Suggestion of an Optimum Model (하수처리구역내 단독정화조의 성능평가 및 최적 모형의 제안)

  • Lim, Bong-Su;Jung, Keum-Hee;Wang, Ze-Jie
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.3
    • /
    • pp.403-409
    • /
    • 2007
  • This study was carried out to recommend the systematic improving practice for the effective operation of septic tank, and the evaluation of its BOD and nutrient removal efficiency depending on process, the survey of characteristics of FRP material, and the suggestion of optimum septic tank model within sewage treatment area. The average BOD concentration and BOD removal efficiency of septic tank which was carried out the cleaning periodically in 63.9 mg/L and 77.8%, shows good quality better than the septic tank which was not carried out the cleaning regularly. Maximum load of tensile, flexural and compressive strength increased in proportion to its thickness, and the contents standard 25% of glass fiber required upgrade over than 30%. Configuration and performance for the optimum of the septic tank suggests that over $0.75m^3$ of the effective total volume, adding to over $0.25m^3$ a man for more than 5 men of the treated person, retention time should be within one day. Improving plans about facility and materials quality of the septic tank have an obligation that protective wall ought to install on the concrete bottom and side faces to prevent crumble or transform from loading of the ground or upper part of the structure on the tank setting. And it is eliminated the uneffective resisting pressure and it keeps off circulate imperfect products by strengthening of the test methods such as stretching strength, pressing strength, glass fiber contents and thickness.

Prediction of Formability of Aluminum Alloy 5454 Sheet (알루미늄 5454 합금 판재의 성형성 예측)

  • Kim, Chan-Il;Yang, Seung-Han;Kim, Young-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.2
    • /
    • pp.179-186
    • /
    • 2012
  • In the automobile industry, reducing the weight is the most important objective for reducing air pollution and improving the fuel efficiency. For this reason, the application of aluminum sheets is increasing. When the sheets are applied to the automobile, using inappropriate variables for the material, product design, and press processing can generate tearing, wrinkling, and spring-back problems, which are the main types of failure in the manufacturing process. Therefore, it is necessary to reduce these failures by harmonizing the many variables and strictly managing the processes. In this research, we study the theoretical plasticity instability of Al5454 and obtain the forming limit diagram (FLD) using MATLAB. Moreover, we compare the theoretical FLD with an experimental FLD obtained from a stretching test.

Severe Weather Events over Northeastern Brasil:The January 2004 Event (브라질 북동부 해안의 악기상: 2004년 1월 사례)

  • Tenorio Ricardo Sarmento;Kwon Byung-Hyuk;Molion Luiz Caries Baldicero;Calheiros Alan James Peixoto
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.5
    • /
    • pp.897-904
    • /
    • 2006
  • The eastern coast of northeastern Brazil (NEB), a coastal land-strip up to 300 km wide and stretching out from Rio Grande do Norte $(5^{\circ}S)$ State down to the south of Bahia State $(17^{\circ}S)$, experiences different rain producing systems, such as distrubances in the south-east trade winds, frontal systems penetration, land-sea breeze circulation and local convection associated with the topography and moisture flux convergence. The annual total rainfall ranges from 600 inland to 3000 mm on the coast. Rainfall totals 5 to 12 times the focal climatic means were recorded in various regions of Alagoas state in January 2004. It was estimated that 46,000 people were homeless, with material damages exceeding US$10 million as a consequence of the ensuing floods. GOES infrared images analysis showed that the main weather system responsible for this anomalously high rainfall totals was an Upper Troposphere Cyclonic Vortex (UTCV), which formed at about a $27^{\underline{\circ}}W\;e\;12^{\underline{\circ}}S$ and remained active for the entire month of January over NEB.

Development of Evaluation Technique of High Temperature Creep Characteristics by Small Punch-Creep Test Method (ll) - Boiler Header - (Sp-Creep 시험에 의한 고온 크리프 특성 평가 기술 개발(ll) - 보일러 헤더 -)

  • Baek, Seung-Se;Lee, Dong-Hwan;Ha, Jeong-Su;Yu, Hyo-Seon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.1
    • /
    • pp.55-60
    • /
    • 2002
  • For the development of a new creep test technique, the availability of SP-Creep test is discussed for 1Cr-0.5Mo boiler header material. And some results are also compared with those of 2.25Cr- 1Mo steel which widely uses as boiler superheater tube. The results can be summarized as follows. The load exponents(n) obtained by SP-Creep test for 1Cr-0.5Mo steel are decreased with increasing creep temperature and the values are 15.67, 13.89, and 17.13 at 550$^{circ}C$ ,575$^{circ}C$ and 600$^{circ}C$, respectively. The temperature dependence of the load exponent is given by n = 107.19 - 0.1108T. This reason that load exponents show the extensive range of 10∼16 is attributed to the fine carbide such as M$_{23}$C$_{6}$ in lath tempered martensitic structures. At the same creep condition, the secondary creep rate of 1Cr-0.5Mo steel is lower than the 2.25Cr-1Mo steel1 due to the strengthening microstructure composed by normalizing and tempering treatments. Through a SEM observation, it can be summarized that the primary, secondary, and tertiary creep regions of SP-Creep specimen are corresponding to plastic bending, plastic membrane stretching, and plastic instability regions among the deformation behavior of four steps in SP test, respectively.y.

$F_2$ Formant Frequency Characteristics of the Aging Male and Female Speakers (한국어 모음에서 연령증가에 따른 제2음형대의 변화양상)

  • 김찬우;차흥억;장일환;김선태;오승철;석윤식;이영숙
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.10 no.2
    • /
    • pp.119-123
    • /
    • 1999
  • Background and Objectives : Conditions such as muscle atrophy, stretching of strap muscles, and continued craniofacial growth factors have been cited as contributing to the changes observed in the vocal tract structure and function in elderly speakers. The purpose of the present study is to compare F$_1$ and F$_2$ frequency levels in elderly and young adult male and female speakers producing a series of vowels ranging from high-front to low-back placement. Material and Methods : The subjects were two groups of young adults(10 males, 10 females, mean age 21 years old range 19-24 years) and two groups of elderly speakers(10 males, 10 females, mean age 67 years : range 60-84 years). Each subject participated in speech pathologist to be a speaker of unimpared standard Korean. The headphone was positioned 2 cm from the speakers lips. Each speaker sustained the five vowels for 5 s. Formant frequency measures were obtained from an analysis of linear predictive coding in CSL model 4300B(Kay co). Results : Repeated measure AVOVA procedures were completed on the $F_1$ and $F_2$ data for the male and female speakers. $F_2$ formant frequency levels were proven to be significantly lower fir elderly speakers. Conclusions : We presume $F_2$ vocal cavity(from the point of tongue constriction to lip) lengthening in elderly speakers. The research designed to observe dynamic speech production more directly will be needed.

  • PDF

FATIGUE LIFE ESTIMATION OF IMPLANT USING A FINITE ELEMENT METHOD (유한요소법을 이용한 치아 임플랜트 피로수명 예측)

  • Han In-Sook;Son Jung-Hun;Yang Young-Soo;Lee Seung-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.414-420
    • /
    • 2006
  • Purpose : The purpose of this study is to use finite element analysis to predict the fatigue life of an implant system subjected to fatigue load by mastication (chewing force). The reliability and the stability of implant system can be defined in terms of the fatigue strength. Not only an implant is expensive but also it is almost impossible to correct after it is inserted. From a bio-engineering standpoint, the fatigue strength of the dental implant system must be evaluated by simulation (FEA). Material and Methods Finite element analysis and fatigue test are performed to estimate the fatigue strength of the implant system. Mesh of implant is generated with the actual shape and size. In this paper, the fatigue strength of implant system is estimated. U-fit (T. Strong, Korea, internal type). The stress field in implant is calculated by elastic-plastic finite element analysis. The equivalent fatigue stress, considering the contact and preload stretching of a screw by torque for tightening an abutment, is obtained by means of Sine's method. To evaluate the reliability of the calculated fatigue strength, fatigue test is performed. Results: A comparison of the calculated fatigue strength with experimental data showed the validity and accuracy of the proposed method. The initiation points of the fatigue failure in the implant system exist in the region of high equivalent fatigue stress values. Conclusion: The above proposed method for fatigue life estimation tan be applied to other configurations of the differently designed and improved implant. In order to prove reliability of prototype implant, fatigue test should be executed. The proposed method is economical for the prediction of fatigue life because fatigue testing, which is time consuming and precision-dependent, is not required.

A STUDY ON THE BIOMECHANICAL PROPERTIES OF ORTHODONTIC RUBBER ELASTIC MATERIALS (교정용 고무탄성재료의 생역학적 성질에 관한 연구)

  • Song, Hyun-Sup;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.21 no.3
    • /
    • pp.563-580
    • /
    • 1991
  • The purpose of this study was to investigate and compare the biomechanical properties of orthodontic rubber elastic materials. Latex bands, nylon-covered elastic threads and polyurethane-based elastic modules, delivering $205{\pm}10$ grams force at 30mm stretching state were selected and stored separately in 3 environments-air ($22{\pm}3^{\circ}C$), distilled water ($37{\pm}1^{\circ}C$), or natural saliva ($37{\pm}1^{\circ}C$). And, the amount of remaining force and permanent elongation of each sample were measured on Instron at interval of 1 hour, 6 hours, 12 hours, 24 hours, 1 week, and 2 weeks. So the data derived were analyzed statistically. The results were as follows: 1. Force decay and permanent elongation of all materials increased with time lapsed; elastic module, latex band and nylon-covered elastic thread in that order of the amount of force decay; elastic module, elastic thread, latex band in that order of the amount of permanent elongation. 2. Among environmental conditions, force decay and permanent elongation in natural saliva, most increased, and those in air, least increased. 3. There was a negative correlation between force decay and permanent elongation. 4. Force decay and permanent elongation were most affected by the material itself, time and environments in that order. 5. After 24 hours in saliva, the percentage of remaining force in elastic module was 51.9% (107.37grams); in latex band, 83.2%(172.62grams); in elastic thread, 85.0%(179.25grams). After 2 weeks in saliva, the percentage of remaining force in elastic module was 42.9%(88.75grams); in latex band, 74.5%(154.50grams); in elastic thread, 77.6%(163.75grams).

  • PDF

Finite Element Analysis for Vibration of Laminated Plate Using a Consistent Discrete Theory Part II : Finite Element Formulation and Implementations (복합재료적층판의 진동해석을 위한 유한요소모델 II. 유한요소모델의 유도 및 해석)

  • 홍순조
    • Computational Structural Engineering
    • /
    • v.7 no.4
    • /
    • pp.103-111
    • /
    • 1994
  • Based on a variational principle of the consistent shear deformable discrete laminate theory derived in the companion paper Part I, a finite element procedure for the vibration analysis of laminated composite plates is presented. The present formulation takes the in-plane displacements of an arbitrary layer, the rotations of the cross section of each layer and transverse displacement of the plate as the state variables at a nodal point of finite element, resulting in total nodal degree of freedom of 2(n+l) +1 for the n-layered laminate. Thus, it allows to specify displacement boundary conditions of layer stretching and/or rotation of layer cross sections around the plate edge and/or lateral displacement. The developed procedure is applied to the free vibration problem for sandwich-type hybrid laminates composed of layers with drastically different material properties whose elasticity solutions are known. Comparison of analysis results with other FEM solutions showed that the present formulation yields better accuracy.

  • PDF

Hydroxide ion Conduction Mechanism in Mg-Al CO32- Layered Double Hydroxide

  • Kubo, Daiju;Tadanaga, Kiyoharu;Hayashi, Akitoshi;Tatsumisago, Masahiro
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.230-236
    • /
    • 2021
  • Ionic conduction mechanism of Mg-Al layered double hydroxides (LDHs) intercalated with CO32- (Mg-Al CO32- LDH) was studied. The electromotive force for the water vapor concentration cell using Mg-Al CO32- LDH as electrolyte showed water vapor partial pressure dependence and obeyed the Nernst equation, indicating that the hydroxide ion transport number of Mg-Al CO32- LDH is almost unity. The ionic conductivity of Mg(OH)2, MgCO3 and Al2(CO3)3 was also examined. Only Al2(CO3)3 showed high hydroxide ion conductivity of the order of 10-4 S cm-1 under 80% relative humidity, suggesting that Al2(CO3)3 is an ion conducting material and related to the generation of carrier by interaction with water. To discuss the ionic conduction mechanism, Mg-Al CO32- LDH having deuterium water as interlayer water (Mg-Al CO32- LDH(D2O)) was prepared. After the adsorbed water molecules on the surface of Mg-Al CO32- LDH(D2O) were removed by drying, DC polarization test for dried Mg-Al CO32- LDH(D2O) was examined. The absorbance attributed to O-D-stretching band for Mg-Al CO32- LDH(D2O) powder at around the positively charged electrode is larger than that before polarization, indicating that the interlayer in Mg-Al CO32- LDH is a hydroxide ion conduction channel.