• 제목/요약/키워드: Material Properties

검색결과 18,199건 처리시간 0.047초

에폭시 수지 모르터의 특성에 관한 실험적 연구 (Experimental Studies on the Properties of Epoxy Resin Mortars)

  • 연규석;강신업
    • 한국농공학회지
    • /
    • 제26권1호
    • /
    • pp.52-72
    • /
    • 1984
  • This study was performed to obtain the basic data which can be applied to the use of epoxy resin mortars. The data was based on the properties of epoxy resin mortars depending upon various mixing ratios to compare those of cement mortar. The resin which was used at this experiment was Epi-Bis type epoxy resin which is extensively being used as concrete structures. In the case of epoxy resin mortar, mixing ratios of resin to fine aggregate were 1: 2, 1: 4, 1: 6, 1: 8, 1:10, 1 :12 and 1:14, but the ratio of cement to fine aggregate in cement mortar was 1 : 2.5. The results obtained are summarized as follows; 1.When the mixing ratio was 1: 6, the highest density was 2.01 g/cm$^3$, being lower than 2.13 g/cm$^3$ of that of cement mortar. 2.According to the water absorption and water permeability test, the watertightness was shown very high at the mixing ratios of 1: 2, 1: 4 and 1: 6. But then the mixing ratio was less than 1 : 6, the watertightness considerably decreased. By this result, it was regarded that optimum mixing ratio of epoxy resin mortar for watertight structures should be richer mixing ratio than 1: 6. 3.The hardening shrinkage was large as the mixing ratio became leaner, but the values were remarkably small as compared with cement mortar. And the influence of dryness and moisture was exerted little at richer mixing ratio than 1: 6, but its effect was obvious at the lean mixing ratio, 1: 8, 1:10,1:12 and 1:14. It was confirmed that the optimum mixing ratio for concrete structures which would be influenced by the repeated dryness and moisture should be rich mixing ratio higher than 1: 6. 4.The compressive, bending and splitting tensile strenghs were observed very high, even the value at the mixing ratio of 1:14 was higher than that of cement mortar. It showed that epoxy resin mortar especially was to have high strength in bending and splitting tensile strength. Also, the initial strength within 24 hours gave rise to high value. Thus it was clear that epoxy resin was rapid hardening material. The multiple regression equations of strength were computed depending on a function of mixing ratios and curing times. 5.The elastic moduli derived from the compressive stress-strain curve were slightly smaller than the value of cement mortar, and the toughness of epoxy resin mortar was larger than that of cement mortar. 6.The impact resistance was strong compared with cement mortar at all mixing ratios. Especially, bending impact strength by the square pillar specimens was higher than the impact resistance of flat specimens or cylinderic specimens. 7.The Brinell hardness was relatively larger than that of cement mortar, but it gradually decreased with the decline of mixing ratio, and Brinell hardness at mixing ratio of 1 :14 was much the same as cement mortar. 8.The abrasion rate of epoxy resin mortar at all mixing ratio, when Losangeles abation testing machine revolved 500 times, was very low. Even mixing ratio of 1 :14 was no more than 31.41%, which was less than critical abrasion rate 40% of coarse aggregate for cement concrete. Consequently, the abrasion rate of epoxy resin mortar was superior to cement mortar, and the relation between abrasion rate and Brinell hardness was highly significant as exponential curve. 9.The highest bond strength of epoxy resin mortar was 12.9 kg/cm$^2$ at the mixing ratio of 1:2. The failure of bonded flat steel specimens occurred on the part of epoxy resin mortar at the mixing ratio of 1: 2 and 1: 4, and that of bonded cement concrete specimens was fond on the part of combained concrete at the mixing ratio of 1 : 2 ,1: 4 and 1: 6. It was confirmed that the optimum mixing ratio for bonding of steel plate, and of cement concrete should be rich mixing ratio above 1 : 4 and 1 : 6 respectively. 10.The variations of color tone by heating began to take place at about 60˚C, and the ultimate change occurred at 120˚C. The compressive, bending and splitting tensile strengths increased with rising temperature up to 80˚ C, but these rapidly decreased when temperature was above 800 C. Accordingly, it was evident that the resistance temperature of epoxy resin mortar was about 80˚C which was generally considered lower than that of the other concrete materials. But it is likely that there is no problem in epoxy resin mortar when used for unnecessary materials of high temperature resistance. The multiple regression equations of strength were computed depending on a function of mixing ratios and heating temperatures. 11.The susceptibility to chemical attack of cement mortar was easily affected by inorganic and organic acid. and that of epoxy resin mortar with mixing ratio of 1: 4 was of great resistance. On the other hand, when mixing ratio was lower than 1 : 8 epoxy resin mortar had very poor resistance, especially being poor resistant to organicacid. Therefore, for the structures requiring chemical resistance optimum mixing of epoxy resin mortar should be rich mixing ratio higher than 1: 4.

  • PDF

소조사면 전량분포의 특성에 관한 고찰 (Study on the beam properties of small field sizes)

  • 조정희;이상규;안승권;박재일
    • 대한방사선치료학회지
    • /
    • 제16권1호
    • /
    • pp.1-9
    • /
    • 2004
  • 목적 : 본 연구의 목적은 소조사면의 선량특성을 측정하며 콜리메이터의 위치에 따른 반음영의 변화와 중심선량의 분포양상을 측정하며 측외측정선량점의 변화에 따른 선량분포의 특성을 측정하여 최근 대두되고 있는 소조사면 방사선치료에 유용한 정보를 제공하는데 그 목적이 있다. 대상 및 방법 : 지멘스의 Primart 선형가속기의 6MV에너지를 이용하였으며 측정은 Farmer chamber와 Pinpoint chamber를 이용하여 심부선량율과 beam profile, 중심출력선량의 변화를 측정하였다. 중심선속의 변화에 따른 에너지의 특성과 반음영의 변화를 외측으로 2cm 간격으로 측정하였다. 측정은 $1{\times}1cm,\;3{\times}3cm,\;5{\times}5cm,\;10{\times}10cm$에서 측정하였으며 결과는 표준조건하의 측정값과 비교, 분석하였다. 결과 : Farmer chamber와 Pinpoint chamber를 이용해 $1{\times}1cm$, 10cm깊이에서 측정한 결과 두 측정기간에 소조사면에서는 $30\%$ 이상의 차이를 보였으며 조사면의 크기가 증가함에 따라 두 측정기간의 차이는 급격히 감소했다. 측외측정점의 변화에 따른 선량분포는 큰 차이가 없었으나 조사야의 크기가 감소함에 따라 $1{\times}1cm$에서는 약 $13\%$의 차이를 보여 조사야 크기에 따른 변화가 큰 것으로 측정되었다. 전체조사면에서 반음영이 차지하는 비율도 조사면이 적어짐에 따라 높게 나타났으며 $1{\times}1cm$의 조사면에서는 약 $50\%$가 반음영이 점유하는 것으로 측정되었다. 결론 : 세기조절방사선 치료를 위해서는 각기 다른 에너지 분포를 갖는 여러 각도에서 다수의 조사면를 필요로 하며 여러 복잡한 인자들이 관여하게 된다. 여러 인자들 중에서도 콜리메이터의 형태 및 위치에 따른 출력선량의 변화 양상을 정확히 측정하는 것은 매우 중요하다. 실험결과에서도 알 수 있듯이 측정깊이와 조사면의 크기 및 측정기의 종류에 따른 측정값의 변화가 매우 크게 나타나므로 양질의 세기조절방사선 치료를 제공하기 위해서는 특히 소조사면의 선량분포에 대한 특성을 정확히 측정하는 것이 매우 중요하다.

  • PDF

으름 열매 식초의 품질특성 및 항산화 활성 (Quality Characteristics and Antioxidant Activity of Vinegar Supplemented Added with Akebia quinata Fruit during Fermentation)

  • 이은경;권우영;이지원;윤진아;정강현;송병춘;안정희
    • 한국식품영양과학회지
    • /
    • 제43권8호
    • /
    • pp.1217-1227
    • /
    • 2014
  • 본 연구에서는 으름 열매를 각각 0, 1, 3, 5 및 7%를 첨가하여 2단계 발효한 으름 열매 식초의 발효 중 이화학적 특성과 항산화 활성에 대하여 조사하였다. 식초의 이화학적 특성은 pH, 총산, 알코올, 총당, 아미노산으로 평가하였고, 항산화 활성은 $ABTS^{{\cdot}+}$ 라디칼 소거능, SOD 유사활성능, 환원력으로 평가하였다. 알코올 발효 중 총산과 알코올 함량은 증가하였고 총당 함량은 감소하였다. 초산 발효에서는 총산 함량이 유의적으로 증가하였다. 관능검사 평가에서는 으름 열매 7% 첨가군에서 종합적 기호도가 가장 높게 나타났다. 발효 1일째보다 발효 13일째에 대조군과 으름 열매 첨가 1%에서는 총 폴리페놀 함량에 유의적 차이가 없었으나 으름 열매첨가군 3, 5, 7%에서 총 폴리페놀 함량이 각각 136.6, 381.59, 415.35 mg/100 g으로 유의적으로 증가됨을 볼 수 있었다. 총 플라보노이드 함량은 발효 1일째보다 발효 13일째에 대조군이 21.73 mg/100 g, 으름 열매 첨가군 1, 3, 5, 7%에서 각각 15.79, 15.15, 26.19, 26.87 mg/100 g으로 발효가 진행됨에 따라 유의적으로 증가하였고 으름 열매 첨가량에 따라서도 유의적으로 증가되었다. 탄닌의 함량도 발효 1일째보다 발효 13일째에 대조군이 0.2042 mg/100 g, 으름 열매 첨가군 1, 3, 5, 7%에서 각각 0.2004, 0.1255, 0.1384, 0.1255 mg/100 g으로 유의적으로 증가됨을 보였다. $ABTS^{{\cdot}+}$ 라디칼 소거 활성은 발효 1일째보다 발효 13일째에 5 mg/mL 농도에서 대조군이 5.87%, 으름 열매 첨가군 1, 3, 5, 7%에서 각각 12.59, 25.63, 34.02, 35.25%로 라디칼 소거능이 증가하였고, SOD 유사활성능도 5 mg/mL 농도에서 발효 1일째보다 발효 13일째에 대조군이 8.22%, 으름열매 첨가군 1, 3, 5, 7%에서 각각 17.49, 16.86, 16.89, 15.68% 증가하였다. 환원력은 으름 열매 첨가군 7%에서 발효 1일째에 0.527, 발효 13일째에 1.539로 나타났다. 본 연구 결과에서 항산화 활성은 발효가 진행되는 동안 증가하였고 으름 열매 첨가량에 따라서도 증가하였다. 으름 열매 식초가 발효됨에 따라 $ABTS^{{\cdot}+}$ 라디칼 소거능, SOD 유사활성능, 환원력이 증가하였으며 이것은 높은 폴리페놀, 플라보노이드, 탄닌의 함량이 밀접하게 관여한 것으로 보인다. 그러므로 으름 열매의 높은 항산화 활성이 식초 및 기타 식품에서 기능성 소재로 이용될 것으로 보여준다.

Ti-Getter가 Ti0.96Co0.02Fe0.02O2의 자기적 특성에 미치는 영향 (Ti-Getter Effects on Magnetic Properties of Ti0.96Co0.02Fe0.02O2)

  • 남효덕;김성진;백종근;이상률;박철수;김응찬
    • 한국자기학회지
    • /
    • 제18권3호
    • /
    • pp.109-114
    • /
    • 2008
  • Solid State Reaction법으로 $Ti_{0.96}Co_{0.02}Fe_{0.02}O_2$ 시료를 제조하였다. 각각의 시료를 $870^{\circ}C$, $900^{\circ}C$, $930^{\circ}C$로 24시간 열처리하였다. 이 때 Ti-getter의 유무를 통해 각각의 온도에서 Ti-getter에 따라 시료의 특성이 어떻게 변화하는지 관찰하고자 한다. 제작된 시료의 구조분석을 위해 시료의 분말 회절실험을 실시하였다. VSM을 이용하여 시료의 자성을 측정하고, 금속이온의 형태와 시료 내에서 cluster로 존재하는지 여부를 조사하기 위해 TEM과 SEM, EDS실험을 하였다. XRD pattern 분석결과, 결정구조는 tetragonal구조로써, 순수한 Rutil-$TiO_2$상이 주를 이루며, 2차상으로는 getter가 없을 때는 $Fe_2TiO_5$, 있을 때는 Fe가 관측되었다. 시료의 자성을 측정한 결과, getter가 없을 때는 $870^{\circ}C$일 때 자화값은 약 $0.025{\mu}B$/CoFe 정도로 강자성을 보이지만, $900^{\circ}C$$930^{\circ}C$에서는 강자성을 보이지 않는다. Ti-getter가 있을 때의 자화값은 $870^{\circ}C$에서는 약 $1.1\;{\mu}B$/CoFe, $900^{\circ}C$$930^{\circ}C$일 때는 $1.5\;{\mu}B$/CoFe 정도로 강자성을 보인다. 이러한 자성의 차이는 Ti-getter의 유무에 따른 2차상의 차이로 결정된 것으로 보인다. Titanium이 고온에서 산소와 질소, 공기 속의 수분과 쉽게 결합하는 성질을 가지고 있기 때문에 이것을 이용하면 좀 더 낮은 산소분압을 얻을 수 있다. 시료의 산소분압에 따라 자화값이나 원자 구조의 변화에 상당한 영향을 받게 되어 시료의 특성이 다르게 나타나는 것을 확인 할 수 있다. TEM과 SEM, EDS실험결과에서는 Co와 Fe가 골고루 분포하는 영역이 있는가 하면 Ti만 관측되는 부분도 존재했다. 시료의 Co와 Fe가 시료전체에 골고루 퍼져있는 것이 아니라 부분적으로 분포하고 있음을 확인 할 수 있다.

벼줄기의 크리이프 거동(擧動)에 관한 연구 (Studies on Creep Behavior for Rice Stalks)

  • 허윤근;김성래;이상우
    • 농업과학연구
    • /
    • 제22권1호
    • /
    • pp.1-10
    • /
    • 1995
  • 기계화농업에서 농작물은 재배관리, 수확 및 가공과정에서 기계와 접촉하면서 기계로부터 순간적인 하중 및 지속적으로 받는 하중과 같은 여러 종류의 하중을 받아 변형되거나 파괴로 손상되는 등의 결과가 발생한다. 즉 기계작업 과정에서 작물은 파괴도 일어날 수 있으므로 작물의 물성에 따라 기계가 적응하면서 작업이 수행되어야 질적인 작업능율을 높일 수 있게 된다. 본 연구는 재배 및 수확과정에서 기계로부터 받는 벼 줄기의 역학적 특성의 구명을 위하여 크리이프 시험장치를 설계 제작하여 컴퓨터 측정장치를 구성, Burger모형(模型)에 의하여 수확시기에 측방향(側方向)의 압축하중 및 휨하중을 받는 벼 줄기의 크리이프 특성(特性)을 측정(測定) 분석(分析)하였다. 결과를 요약(要約)하면 다음과 같다. 1. 크리이프 거동은 4요소 Burger모형(模型)에 의하여 벼줄기의 크리이프거동을 정확히 예측(豫測)할 수 있었으며, 예측한 결과는 실측치에 거의 일치하였다. 2. 압축하중의 크기가 증가함에 따라 크리이프 변형량은 증가하는 경향이었는데, 25N 이하의 낮은 하중에서 정상상태 크리이프거동을 하였고, 30N 이상의 높은 하중에서 대수적 크리이프거동을 하였다. 3. 작용하중에 따른 크리이프거동을 나타내는 모형의 계수를 구하였는데 순간탄성계수 $E_0$ 및 지연시간 ${\tau}_K$는 작용하중의 증가에 따라 증가하였고, 지연탄성계수 $E_r$ 및 점성계수 ${\eta}_v$는 작용하중 증가에 따라 감소하는 점탄성(粘彈性) 재료(材料)임을 확인할 수 있었다. 4. 측방향 압축 하중이 25.0 N 이상 작용할 때 줄기 중부 및 상부에서 정상상태(定常狀態) 크리이프가 일어나, 하중의 작용시 줄기 부위(部位)에 따른 저항력은 하부(下部)에서 가장 컸고, 중부(中部)에서 가장 작게 나타나 파손 가능성이 높은 것으로 판단된다. 5. 압축하중 및 휨하중의 작용에 의한 줄기 부위에 따른 크리이프변형은 줄기 중부(中部)에서 가장 크게 일어났고, 하부(下部)에서 가장 작게 일어나 중부의 저항력이 가장 낮게 나타났다.

  • PDF

공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구 (A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS)

  • 박철;임주환;조인호;임헌송
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

첨상용 레진의 성형법이 의치상의 굴곡강도에 미치는 영향 (The Effect of Packing Method of Relining Material on the Flexural Strength of Denture Base Resin)

  • 김민철;김유리
    • 구강회복응용과학지
    • /
    • 제27권2호
    • /
    • pp.197-207
    • /
    • 2011
  • 의치상의 첨상에 사용하는 레진의 종류가 의치상의 굴곡강도와 굴곡계수에 미치는 영향을 비교하는데 있다. 국제표준규격 제 1567 호(ISO 1567:1999)를 참고로 2 가지의 의치상용 열중합레진(Lucitone199(Dentsply Int., NewYork, USA), SR-Ivocap(Ivoclar AG, Schaan, Liechtenstein))을 이용하여 길이 64 mm ${\times}$ 폭 50 mm ${\times}$ 두께 3.3 mm 의 시편을 제작하였다. 각각의 제작된 시편을 다시 두께 2.0 mm 로 규격화한 뒤 3 종류의 레진(Lucitone199 (Dentsply), SR-Ivocap(Ivoclar), Rebase II(Tokuyama Co., Ltd, Tokyo, Japan))으로 각각 1.3 mm 의 두께로 첨상을 하였다. 제작된 시편(n=10)을 증류수가 담긴 밀폐된 용기 내에 $37^{\circ}C$에서 50 시간 동안 보관하였다. 그 후 만능시험기를 이용하여 시편의 3 점 굴곡강도와 굴곡계수를 측정하였다. 지지대간의 거리는 50 mm, crosshead speed 는 5 mm/min 였다. 측정값은 One-way ANOVA 로 비교 분석하였고, Tukey test 를 이용하여 사후 검정하였다. 열중합형 레진과 자가중합형 레진으로 첨상한 군들은 모두 첨상을 시행하지 않은 대조군보다 통계적으로 유의하게 낮은 굴곡강도와 굴곡계수를 나타났다. 본래의 의치상용 레진의 종류와 무관하게 Lucitone199 을 이용해 첨상한 군이 SR-Ivocap 을 이용한 군보다 통계적으로 유의하게 높은 굴곡강도와 굴곡계수를 보였다. 자가중합형 레진을 이용한 군은 열중합형 레진을 이용한 군 보다 통계적으로 유의하게 낮은 굴곡강도와 굴곡계수를 보였다. 의치상의 첨상 시 자가중합형 레진 보다 열중합형 레진을 이용하는 것이 우수한 기계적 성질을 보였다. 열중합형 레진을 이용한 첨상 시 본래의 의치상과 같은 종류의 레진을 사용하는 것은 의치상의 기계적 성질에 영향을 미치지 않았으며 Lucitone199 를 이용한 가압주형법에서 가장 우수한 물성을 나타냈다.

석산에서 생산되는 부순골재의 재료 특성에 관한 연구 (A Experimental Study on the Material Charateristics of Crushed Aggregate Produced in Quarry)

  • 백동일;염치선;김명식
    • 콘크리트학회논문집
    • /
    • 제17권4호
    • /
    • pp.569-579
    • /
    • 2005
  • 본 연구는 부산의 동부, 중부, 서부지역을 대표하는 양산, 김해, 진해에서 생산된 부순모래를 사용한 부순모래 콘크리트의 장기강도 특성에 관한 연구를 수행하였다. 콘크리트는 전체 체적의 70~80%가 골재로 이루어져 있어 콘크리트의 특성에 골재의 품질의 영향은 매우 중요하다. 1980년대 이후, 천연자갈과 천연모래의 고갈로 콘크리트에 사용되어지는 골재는 이미 부순돌로 대체되었다. 부순모래는 해사 채취금지와 강모래의 고갈로 사용량이 증가하고 있는 경향이다. 부순모래는 혼입량의 변화와 부순모래의 혼합비(50, 60, 70, 80, 90, 100%)의 변화에 따른 콘크리트의 특성을 조사하기 위하여 강모래와 혼합하였다. 경화하지 않은 콘크리트의 성질을 조사하기 위해 슬럼프와 공기량을 측정하였다. 경화한 콘크리트의 성질을 조사하기 위해 재령 7, 28, 60, 90, 180일에 단위중량, 압축강도 그리고 탄성계수를 측정하였다. 압축강도, 단위중량 그리고 탄성계수는 재령의 증가에 따라 값이 증가하였으며 장기 재령에서도 역시 증가할 것으로 예상된다. 지역별 골재의 품질 시험결과들은 모두 KS규격을 만족하였다. 슬럼프 측정결과는 혼입률 70~80%까지는 증가하였으나 그 이상에선 감소하였다. 공기량은 마이크로 필러 현상에 의해 부순모래의 혼입률 증가에 따라 감소하였다. 재령 7, 28, 60, 90, 180일에 단위중량을 측정한 결과에 따르면, 단위중량은 부순골재의 혼입률 증가에 따라 역시 증가하였다. 재령 7, 28, 60, 90, 180일에 압축강도와 탄성계수를 측정한 결과, 압축강도는 혼입률 70%일 때 가장 높게 나타났다.

CAD/CAM 의치상 레진과 열중합 의치상 레진의 두께에 따른 굴곡 강도 비교 (Comparison of flexural strength according to thickness between CAD/CAM denture base resins and conventional denture base resins)

  • 이동형;이준석
    • 구강회복응용과학지
    • /
    • 제36권3호
    • /
    • pp.183-195
    • /
    • 2020
  • 목적: 이 논문의 목적은 CAD/CAM 의치상 레진과 열중합 의치상 레진의 굴곡 강도를 비교해보고, 두께에 따른 굴곡 강도 변화도 비교해보는 것이다. 연구 재료 및 방법: 열중합 의치상 레진은 Lucitone 199® (C-LC)을 사용하였다. 3D printing 의치상 레진으로는 DIOnavi - Denture (P-DO)와 DENTCA - Denture Base II (P-DC)를 사용하였다. 밀링 PMMA 블록으로는 Vipi Block Gum (M-VP)과 M-IVoBase® CAD (M-IV)를 사용하였다. 시편의 최종 규격은 65.0 mm × 12.7 mm × 1.6 mm / 2.0 mm / 2.5 mm였다. 굴곡 강도와 굴곡 탄성율을 측정하기 위해 3점 굽힘 시험을 실시하였다. 그리고 파절된 시편의 단면을 주사전자현미경 (SEM) 을 사용하여 분석하였다. 데이터의 정규성을 확인한 뒤 일원분산분석(one-way ANOVA)을 사용하여 유의 수준 P = 0.05로 설정하여 그룹 간의 차이를 평가한 뒤, 사후 분석을 위해 Tukey HSD test를 시행하였다. 결과: 동일 두께 내에서, P-DO를 제외한 나머지 CAD/CAM 의치상 레진들과 열중합 의치상 레진의 굴곡 강도는 유의한 차이를 나타내었다. M-VP는 열중합 의치상 레진 보다 굴곡 강도가 높게 나타났고, P-DC와 M-IV는 낮은 굴곡 강도를 보였다. 굴곡 탄성률은 M-VP에서 제일 높게 나타났고 C-LC, P-DO, P-DC, M-IV 순으로 낮아졌으며 재료간에 모두 유의한 차이가 나타났다. 두께에 따른 굴곡 강도는, C-LC에서는 2.5 mm가 1.6 mm보다 유의하게 높은 굴곡 강도를 보였고, P-DC, M-VP는 2.5 mm와 2.0 mm에서 1.6 mm보다 유의하게 높은 굴곡 강도가 나타났다. M-IV에서는 두께가 증가할수록 유의한 굴곡 강도 증가가 나타났다. SEM 분석 결과 서로 다른 재료들의 파절된 단면은 각기 다른 양상을 띄었다. 결론: 본 연구에서 사용된 CAD/CAM 의치상 레진의 굴곡 강도는 각 재료의 성분 및 특성에 따라 다양하게 나타났다. CAD/CAM 의치상 레진의 굴곡 강도는 두께가 감소하여도 1.6 mm 이상의 두께에서는 ISO 20795-1:2013에서 제시하는 굴곡 강도보다 높게 나타났다. 하지만 보다 얇은 두께의 의치를 임상적으로 사용하기 위해서는, 더 낮은 두께의 의치상 레진의 다른 특성들에 관한 추가적인 연구가 필요하다.

탄자니아산 루비의 열처리에 의한 보석·광물학적 품질개선 연구 (A Mineralogical and Gemological Studies for the Enhancement of Tanzania Ruby by Heat Treatment)

  • 김선옥;왕수균;오설미;박희율;박맹언
    • 자원환경지질
    • /
    • 제47권6호
    • /
    • pp.563-569
    • /
    • 2014
  • 루비는 유색보석 중에서 가장 선호도가 높은 보석인 동시에 열처리에 의해 부가가치를 높일 수 있어 학문적인 연구 대상으로서도 그 관심이 높다. 세계적으로 많은 지역에서 루비가 산출되고 있음에도 불구하고, 고품질의 천연 루비는 미얀마, 스리랑카, 태국, 탄자니아 등 일부 제한된 국가에서만 산출되며, 오랜 기간 채광으로 인해 고품질의 원석이 고갈되어가고 있는 실정이다. 이 연구에서는 최근 새로운 산지가 확인되어 관심이 높은 탄자니아산 루비 원석을 사용하여 전통적인 단순 열처리방법과 화학적 열처리 방법에 의한 광물학적 및 보석학적 특성을 파악하고, 열처리에 의한 탄자니아산 루비의 품질개선 효과를 검토하였다. 미얀마의 Mogok산과 Mong Hsu산 루비에 효과적인 방법으로 알려진 전통적인 단순 열처리 실험은 T=$1,600^{\circ}C$에서 6시간 동안 실시하였다. 그 결과, 비교적 균일한 암적색을 지닌 탄자니아산 루비의 색상과 투명도는 색채 색차계와 자외선-가시광선 분광분석(UV-Vis Spectrometry) 결과, CIE 1931 color space 상의 적색과 청색의 좌표값(X, Y)이 원시료 (0.365, 0.321) 및 (0.346, 0.363)에서 (0.337, 0.322)로 감소함이 확인되어, 전통적인 단순 열처리 방법이 탄자니아산 루비의 품질개선에 적합하지 않은 것으로 판단되었다. 단순 열처리를 수행한 탄자니아산 루비의 X-선형광분석(XRF) 결과, 루비의 적색을 발현 시키는 $Cr^{3+}$함량이 0.72~1.04 wt.%로 증가 되었으나, 갈색의 보조색상을 발현시키는 Fe의 함량이 함께 증가되어 순수한 적색이 아닌 어두운 적색을 띄는 것으로 확인되었다. 이러한 결과는 단순 열처리에 의해 루비에 함유되어 있는 $Fe_2O_3$의 응집현상으로 어두운 색으로 변한 것이라 판단된다. 또한 열처리에 의해 $SiO_2$의 함량이 특징적으로 높게 나타났는데, 이는 열처리 과정동안 용융되었다가 다시 재결정화 되면서 생기는 현상으로 투명도의 개선에 효과적이지 않음을 알 수 있었다. 탄자니아산 루비 중 표면에 균열이 있는 시료를 선별하여 납(Pb)을 주성분으로 하는 화학적 첨가제를 사용한 열처리 실험 결과, 색상 뿐 만아니라, 투명도가 현저하게 개선되었다. CIE 1931 color space 상의 적색과 청색의 좌표값이 원시료 (0.386, 0.304) 및 (0.395, 0.313)에서 (0.405, 0.308)로 적색영역에 도시되었다. 이는 첨가제가 열처리 과정동안 용융되어 루비의 균열부분을 채워준 것으로 확대경으로도 관찰이 가능하다. 또한 루비의 표면과 균열부분에 대한 전자현미분석(EPMA)의 선분석(line scanning)에 의해서도 확인되었다. 이 첨가제는 균열부분을 충진함으로써 내구성과 투명도가 개선되었다. 첨가제의 용융체는 루비와 굴절률이 매우 비슷하기 때문에 입사된 빛이 루비 내부로 더 쉽게 통과하여 전반적으로 색상이 향상된 것으로 판단된다. 이 연구에서 화학적 열처리가 탄자니아산 루비의 품질향상에 적합한 방법임을 확인할 수 있었으며, 사파이어 등 강옥군 광물의 유색보석에 대한 색과 투명도 개선에 매우 유용할 것으로 생각된다.