• Title/Summary/Keyword: Mass ratio

검색결과 4,013건 처리시간 0.036초

Full-scale test of dampers for stay cable vibration mitigation and improvement measures

  • Zhou, Haijun;Xiang, Ning;Huang, Xigui;Sun, Limin;Xing, Feng;Zhou, Rui
    • Structural Monitoring and Maintenance
    • /
    • 제5권4호
    • /
    • pp.489-506
    • /
    • 2018
  • This paper reported test of full-scale cables attached with four types of dampers: viscous damper, passive Magneto-Rheological (MR) damper, friction damper and High Damping Rubber (HDR) damper. The logarithmic decrements of the cable with attached dampers were calculated from free vibration time history. The efficiency ratios of the mean damping ratios of the tested four dampers to theoretical maximum damping ratio were derived, which was very important for practical damper design and parameter optimization. Non-ideal factors affecting damper performance were discussed based on the test results. The effects of concentrated mass and negative stiffness were discussed in detail and compared theoretically. Approximate formulations were derived and verified using numerical solutions. The critical values for non-dimensional concentrated mass coefficient and negative stiffness were identified. Efficiency ratios were approximately 0.6, 0.6, and 0.3 for the viscous damper, passive MR damper and HDR damper, respectively. The efficiency ratio for the friction damper was between 0-1.0. The effects of concentrated mass and negative stiffness on cable damping were positive as both could increase damping ratio; the concentrated mass was more effective than negative stiffness for higher vibration modes.

감쇠진동계에 부착된 복합동흡진기의 효과에 관한 연구 (A Study on the Effects of Dual Dynamic Vibration Absorber for Damped Vibration System)

  • 안찬우;최석창;김동영
    • 소음진동
    • /
    • 제7권6호
    • /
    • pp.1039-1048
    • /
    • 1997
  • This paper describes the effects of dual dynamic vibration absorbers attached to a primary vibration system with damping. The efficiency of dual dynamic vibration absorbers was investigated with the height of amplitude ratio at the resonance frequency ratio of the damped vibration system according to mass ratio, natural frequency ratio and damping ratio. The variation of amplitude ratio related to frequency ratio of primary vibration system is verified experimentally and theoretically according to dual dynamic vibration systems using computer program designed to find mutual relationship between two absorbers.

  • PDF

전기와 자기장 복합 침 자극을 활용한 복부비만 치료 6례에 대한 증례 보고 (A Report on 6 cases of Abdominal Obesity using Electroacupuncture Combined with Magnetic Acupuncture)

  • 윤지원;이현;김윤주;강재희
    • Journal of Acupuncture Research
    • /
    • 제32권4호
    • /
    • pp.213-226
    • /
    • 2015
  • Objectives : This study was aimed to show the effect of electroacupuncture combined with magnetic acupuncture on abdominal obesity without patient dieting, exercise or use of herbal medication. Methods : Women over 85 cm in waist circumference were treated with electroacupuncture combined with magnetic acupuncture. Acupuncture points were located at the abdomen ($CV_{12}$, $CV_6$, $ST_{25}$, $ST_{21}$, $SP_{15}$, $SP_{14}$), extremities ($LI_4$, $LI_{11}$, $ST_{36}$, $ST_{44}$) and were stimulated 30 minutes with 2.1~3 Gaus, 500 Hz, tolerable strength. The Interference wave forms were by Whata 153 (Medi Lab, Korea). Two or three treatment sessions per week (five or ten sessions in total) were done. Before treatment, and after the last treatment, we measured waist circumference, hip circumference, waist hip ratio, thickness of abdominal subcutaneous fat, body weight, body mass index, body fat ratio, visceral fat area, free fat mass, body fat mass and skeletal muscle mass. We also measured the subcutaneous temperature of the abdomen($CV_{12}$, $ST_{25}(Rt)$, $ST_{25}(Lt)$, $CV_6$) by using digital infrared thermal imaging(DITI). Results : In this study, significant reductions were shown in waist circumference, hip circumference, thickness of abdominal subcutaneous fat, body weight, body mass index, body fat ratio and body fat mass. There were no significant differences in waist hip ratio, free fat mass or skeletal muscle mass. There were also significant increases of the subcutaneous temperature on $CV_{12}$, $ST_{25}(Rt)$, $ST_{25}(Lt)$. Conclusions : From the above results, electroacupuncture combined with magnetic acupuncture might be an effective treatment for abdominal obesity.

비만과 심혈관 질환 위험인자와의 상관관계 분석 -건강검진 대상자를 중심으로- (Correlation study between Obesity and Cardiovascular Risk Factors)

  • 조태영;조현철;홍서영;송윤경;임형호
    • 한방비만학회지
    • /
    • 제4권1호
    • /
    • pp.33-43
    • /
    • 2004
  • Background: Recently obesity has become a social problem in all over the world including Korea. It is known that obesity is closely related with cardiovascular disease. Many studies are carrying out in the relation between several obesity indices, such as body mass index(BMI), waist-circumference(WC), body fat percent and risk factors of cardiovascular disease. Objective: This study was done in order to investigate correlation of obesity and cardiovascular risk factors. Method: We gathered totally 138 subjects who have taken health screening test in university hospital. With the exception of 40 abnormal cases on current illness and laboratory study, 98 healthy cases were analysed. We divided the groups as normal, overweight, obese group according to body mass index $(22.9kg/m^2\;and\;below\;/\;23{\sim}24.9kg/m^2\;/\;25kg/m^2\;and\;above)$and investigated the relationship between obesity based on body mass index(BMI) and cardiovascular risk factors. And investigated the relationship between each cardiovascular risk factor and body mass index, waist-hip ratio, body fat percent. Results: With the exception of blood pressure, other lab data such as total cholesterol, triglycerid, glucose were significantly different between the three groups divided by body mass index$(22.9kg/m^2\;and\;below\;/\;23{\sim}24.9kg/m^2\;/\;25kg/m^2\;and\;above)$. And Correlation coefficient of cardiovascular risk factors with body mass index, waist-hip ratio, body fat precent were acquired. Conclusion: We have concluded that the body mass index and waist-hip ratio body fat precent were predictive factors cardiovascular disease.

  • PDF

STRUCTURE OF THE SPIRAL GALAXY NGC 300 II. Applications of the Mass Models

  • Rhee, Myung-Hyun;Chun, Mun-Suk
    • 천문학회지
    • /
    • 제25권1호
    • /
    • pp.11-21
    • /
    • 1992
  • Applying mass model to disk galaxy NGC 300, since the observed rotation curve of NGC 300 is flatter than Toomre's mass model n = 1, two cases are used; obtaining parameters $a^n$ and $b^n$ from the polynomial fitting of the observed rotation curve (case A) and from the least square fitting between the observed rotation curve and model rotation curve (case B). In any case, n bas a fixed value of 1. Brandt's mass model is also discussed. which has a shape parameter n = 1.4. Calculated total mass and total mass to luminosity ratio are $3.3{\times}10^{10}M_{\odot}$, l2.1 for case A and $2.8{\times}10^{10}M_{\odot}$, 10.3 for case B. In case of Brandt's model, the values are $4.2{\times}10^{10}M_{\odot}$ and 15.4. The rise in the local mass to luminosity ratio in the outer part of NGC 300 implies existence of massive halo. Other dynamical properties are also discussed.

  • PDF

충격식 감쇠기를 이용한 동흡진기의 개발에 관한 연구 (Study on the Characteristics and Development of Impact Dynamic Vibration Absorber)

  • 김원철;이소환;양보석
    • 수산해양기술연구
    • /
    • 제32권4호
    • /
    • pp.421-431
    • /
    • 1996
  • From comparing the impact dynamic absorber with the impact damper in the auxiliary vibration system with the conventional dynamic absorber, the following conclusions are obtained as follows ; 1. Recognizing that the amplitude restraining effect of the impact dynamic absorber become resonable in a comparison of conventional one development of an improved dynamic absorber may be probable. 2. With increasing the frequency ratio, the 1st resonance peak is higher but the 2nd one gets lower. In addition, the frequency ratio is peak located at the same resonance. 3. The optimum impact clearance is smaller and the vibration constraining effect becomes better with and increase in the mass of impact ball. And it is recognizable that the optimum tuning frequency ratio and impact clearance in an accordance with the mass ratio are varied. 4. The optimum tuning condition becomes gradually lower than the case of r=1 and maximum amplitude becomes lower with an increment in the mass ratio. However, the impulse clearance is larger and the working range of restraining vibration amplitude become smaller with a decrement in the mass of impact ball.

  • PDF

경량화용 박육부재의 형상비가 압궤특성에 미치는 영향 (Influence of dimensional ratio on collapse characteristics for the thin-walled structures of light weight)

  • 정종안;김정호;양인영
    • 한국안전학회지
    • /
    • 제13권3호
    • /
    • pp.11-23
    • /
    • 1998
  • In this study, collapse test of thin-walled structure is performed under axially quasi-static and impact load in collapse characteristic to develop the optimum structural member for a light-oriented automobile. Furthermore, the energy-absorbing capacity is observed according to the variety of configuration(circular, square), aspect ratio in aluminum specimen to obtain basic data for the improved member of vehicle. In both quasi-static and impact collapse test, Al circular specimens collapse, in general, with axisymmetric mode in case of thin thickness while collapse with non-axisynmetric mode according to the thickness increase. For Al rectangular specimens, they collapse with axisymmetric mode in case of thin thickness, with mixed collapse mode according to the increase of thickness. In terms of initial max. load, Al square specimen turns out the best member among specimens, and then Al square, circular and circular with large scaling ratio, respectively. In case of quasi-static compression test, the absorbed energy per unit volume and mass shows higher in Al circular specimen, and then Al square, circular with large scaling ratio, respectively, according to shape ratio the absorbed energy per unit volume and mass in case of max. impact compression load is higher than that of static load. But the absorbed energy per unit volume and mass shows that Al circular specimen is the best member. Especially, unlike max. compression loan, the absorbed energy per unit volume and mass in impact test turns out the low value.

  • PDF

Distribution of Baryonic Matter in Dark Matter Halos: Effect of Dynamical Friction

  • 배영복;이형목
    • 천문학회보
    • /
    • 제36권1호
    • /
    • pp.47.1-47.1
    • /
    • 2011
  • We studied the evolution of the two mass components system with NFW initial density distribution by direct integration of the Fokker-Planck equations. The low mass component is regarded the dark matter particles while the high mass component is assumed to be conglomerates of baryonic matter in order to depict the 'stars'. While the true mass ratio between these two types of particles should be extremely large, our adopted mass ratio is about 1000 beyond which the dynamical evolution and density distribution tend to converge. Since the dynamical evolution is dominated by the dynamical friction, the high mass component slowly moves toward the central part, and eventually undergoes the core collapse. The system reaches the core-collapse at about $7.1{\times}10^{-3}$ $t_{fh}$ in NFW models, where $t_{fh}$is the dynamical friction time at half-mass radius. The distribution of the high mass component is well fitted by the Sersic profiles or modified Hubble profile when the mass segregation is established. From these results, the surface brightness of elliptical galaxies may be explained by the high mass component experiencing dynamical friction by the dark matter particles. In order for the mass segregation to be effective within Hubble time, the mass of the luminous component should be greater than $10^5M_{\bigodot}$.

  • PDF

4밸브 디젤기관의 흡기포트 편심이 실린더 내 선회비 특성에 끼치는 영향에 관한 연구 (A Study on the Effects of Intake Port Eccentricity on the In-cylinder Swirl Ratio Characteristics in a 4 Valve Diesel Engine)

  • 이지근;강신재;노병준
    • 한국자동차공학회논문집
    • /
    • 제5권5호
    • /
    • pp.157-169
    • /
    • 1997
  • The effects of intake port eccentricity on the characteristics of in-cylinder swirl ratio in a 4-valve diesel engine having the two intake ports; one is a helical intake port and the other is a tangential intake port were investigated by using the ISM(impulse swirl meter) in steady flow test rig. Swirl ratio($R_s$) and mean flow coefficient($C_{f(mean)}$) with valve eccentricity ratio($N_y$) and axial distance(Z/B) were measured. As the results from this experiment, the characteristics of in-cylinder swirl ratio formed by a 4-valve cylinder head were largely affected by intake port eccentricity. There is a difference in the mass flowrate through the two intake ports, and the mass flowrate through the tangential intake port is 19% more than that of the helical intake port. Therefore, we could know that the effects of the mass flowrate ratio through each intake port besides intake port shape should be conidered.

  • PDF

사각 덕트 내부 열전달 향상을 위한 요철의 단락 효과 (Effects of Discrete Rib-Turbulators on Heat/Mass Transfer Augmentation in a Rectangular Duct)

  • 권혁진;우성제;조형희
    • 대한기계학회논문집B
    • /
    • 제24권5호
    • /
    • pp.744-752
    • /
    • 2000
  • The influence of arrangement and length of discrete ribs on heat/mass transfer and friction loss is investigated. Mass transfer experiments are conducted to obtain the detailed local heat/mass transfer information on the ribbed wall. The aspect ratio (width/height) of the duct is 2.04 and the rib height is one tenth of the duct height, such that the ratio of the rib height to hydraulic diameter is 0.0743. The ratio of rib-to-rib distance to rib height is 10. The discrete ribs were made by dividing each continuous rib into 2, 3 or 5 pieces and attached periodically to the top and the bottom walls of the duct with a parallel orientation The combined effects of rib angle and length of the discrete ribs on heat/mass transfer ae considered for the rib angles $({\alpha})\;of\;90^{\circ}\;and\;45^{\circ}$. As the number of the discrete ribs increases, the uniformity of the heat/mass transfer distributions increases. For $(\alpha})=90^{\circ}$, the heat/mass transfer enhancement with the discrete ribs is remarkable, while the heat/mass transfer performances are slightly higher than that of the transverse continuous ribs due to the accompanied high friction loss penalty. For $(\alpha})=90^{\circ}$, the average heat/mass transfer coefficients and the heat/mass transfer performances decrease slightly with the discrete ribs compared to the case of the angled continuous ribs.