• 제목/요약/키워드: Mass flow meter

검색결과 124건 처리시간 0.025초

수소충전소의 연료 계량 방법에 따른 계량 오차가 발생하는 원인 고찰 (The Study to Find Causes for Measuring Differences of Hydrogen Fillings in Hydrogen Refueling Station)

  • 이택홍;강병우;이은웅;정진배;홍석진
    • 한국수소및신에너지학회논문집
    • /
    • 제29권1호
    • /
    • pp.32-40
    • /
    • 2018
  • There has been an measuring errors between state of charge (SOC; kg) value and mass flow meter (MFM) value in dispenser for hydrogen refueling station. Finally, we observed average 15.5% weight difference between these two values and the MFM readings show a 15.5% higher readout of the SOC readings. Each car was charged with average 2.66 kg of hydrogen fuel during this period. In the initial charging of the day shows less measuring value than the final charging with the maximum 0.038 kg times number of filling. There is no effects of atmosphere temperature change for the hydrogen filled weight during one full year such as January's cold winters and August's hot summers.

수소 충전소 연료계량방법의 차이에서 발생하는 연료단가의 상이점에 대한 고찰 (A Study on the Variation of Unit Price of Hydrogen Fuel by Difference of Fuel Measuring Method)

  • 이택홍;강병우;이은웅;정진배
    • 한국수소및신에너지학회논문집
    • /
    • 제28권3호
    • /
    • pp.279-286
    • /
    • 2017
  • Korea government decides to build one hundred hydrogen refueling stations (HRS) until 2020 and tries to disseminate HRS and boosts HRS market in korea. Naepo HRS in chungnam province has been operated for last one full year of 2016 and recorded 2,520 times full charge for the hydrogen fuel cell powered vehicles and total 6,016 kg hydrogen fueling for the 25 units of hydrogen fuel cell powered vehicles. Raw fuel of hydrogen from tube trailer measured by pressure, converting into weight of hydrogen and shows 19.6% surplus with final charged weight by dispenser. This result is caused measuring errors. Measured charged errors between dispenser and Mass flow meter was determined 13.13%.

트윈스크롤 터보과급기에서 맥동유동의 질량유량 측정 (Mass Flow Rate Measurement of Pulsating Flow in a Twin-Scroll Turbocharger)

  • 정진은;전세훈
    • 한국산학기술학회논문지
    • /
    • 제20권12호
    • /
    • pp.723-729
    • /
    • 2019
  • 터보과급기는 엔진에 장착하여 연비를 개선하는 효과적인 장치로 디젤엔진과 가솔린엔진 모두에서 광범위하게 사용되고 있다. 본 연구에서는 승용차용 가솔린엔진에 사용되는 트윈스크롤 터보과급기에서 발생하는 맥동유동의 질량유량을 측정하였다. 자체 설계 제작한 맥동유동장치를 사용하여 맥동이 있는 비정상상태에서 유동의 질량유량을 측정하였고, 맥동이 없는 정상상태의 질량유량과 비교 분석하였다. 맥동유동장치는 회전하는 상판과 고정된 하판을 사용하여 변하는 엔진의 배기밸브 유효면적을 반영하였다. 맥동이 있는 비정상상태 질량유량을 측정하기 위하여 차압식 압력계를이용한 오리피스 유량계를 사용하였다. 이때 기체의 온도와 절대압력을 측정하여 기체 밀도 변화를 고려하였다. 터보과급기의 저속 성능을 분석하기 위하여 압축공기를 사용하여 터보과급기 회전속도 60,000rpm에서 100,000rpm의 범위에서 측정을 수행하였다. 비정상상태의 질량유량은 정상상태와 비교하여 크게 다른 결과를 보였다. 정상상태 질량유량 계수는 터빈 팽창비가 증가함에서 따라 증가하지만, 비정상상태 질량유량 계수는 정상상태 값 주변의 히스테리시스 루프를 형성하며 변화량은 정상유동 기준 최대 5.0배이다. 이것은 맥동유동에 의하여 터빈 볼류트 공간에서 충진과 방출이 일어나기 때문이다.

공기양정(Air-Lift)펌프의 양수특성에 관한 연구 (A Study on Lifting Characteristics of Air-Lift Pump)

  • 김동균;이철재;배석태;조태환
    • 한국해양공학회지
    • /
    • 제13권3B호
    • /
    • pp.14-21
    • /
    • 1999
  • As an effective means to convey crushed materials from seabed to onboard ship and to raise hazardous or abrasive liquids, air-lift pump provides a reliable mechanism due to its simple configuration and easy-to-operate principle. The present study is focused on investigation of related performance by the analysis program based on the gas-liquid two-phase flow in circular pipes. The program covers pump operating in isothermal and vertical two-phase flow with Newtonian liquids. It is summarized as important result that an optimum air mass flow rate exists for the maximum lifted liquid mass flow rate in terms of a given submergence rates. The comparison between riser performance of the conveyed liquid flow rate calculated by the computer program and measured data with large scale air lift pump system constructed in 200 meter depth vertical tank reveals similar distribution.

  • PDF

DME를 연료로 하는 압축 착화 엔진 용 플런저식 고압펌프의 유량 성능 연구 (A Study on the Flow Rate Performance of Plunger-Type High-Pressure Pump for Compression Ignition Engine Using DME as Fuel)

  • 정재희;이세준;유동규;임옥택
    • 한국가스학회지
    • /
    • 제26권4호
    • /
    • pp.1-8
    • /
    • 2022
  • 디젤엔진의 대체 연료로 연구되고 있는 청정연료인 DME는 디젤엔진의 중요한 문제 중 하나인 배기가스를 줄일 수 있으며, 세탄가와 산소함유량이 매우 높다. DME는 LPG와 유사한 특성을 가진 연료로 LPG 유통 인프라를 사용할 수 있다. 본 연구에서는 플런저식 고압펌프의 성능평가를 위해 토출된 질량유량에 대한 기초 데이터베이스 구축을 목표로 하였으며, 커먼레일 압력과 모터 회전속도를 변화시켜 플런저식 고압펌프의 질량유량을 분석하였다. 실험 조건은 커먼레일 압력을 300 bar, 400 bar, 500 bar 로 변경하였고, 모터 회전 속도를 300 rpm에서 1000 rpm 으로 증가시켰다. 실험 결과 두 경우 모두 질량유량이 증가하였다.

4밸브 디젤기관의 흡기포트 편심과 두 흡기포트 사이의 격막이 실린더 내 선회 특성에 미치는 영향에 관한 연구 (A study on the effects of intake port eccentricity and a partition between the two intake ports on the in-cylinder swirl characteristics in a valve diesel engine)

  • 이지근;강신재;노병준
    • 대한기계학회논문집B
    • /
    • 제21권7호
    • /
    • pp.948-961
    • /
    • 1997
  • The effects of intake port eccentricity and a partition between the two intake ports on the incylinder swirl characteristics in a 4 valve diesel engine having the two intake ports, one is a helical intake port and the other is a tangential intake port, were investigated by using the impulse swirl meter(ISM) in a steady flow test rig. Mean flow coefficient ( $C_{f(mean)}$, swirl ratio ( $R_{s}$) and the mass flowrate through the two intake ports with and without intake port partition were measured. The results showed that the characteristics of in-cylinder swirl ratio formed by a 4-valve cylinder head were largely affected by valve eccentricity ratio ( $N_{y}$) and the existence of an intake port partition between the two intake ports. Mean flow coefficient ( $C_{f(mean)}$) increases and swirl ratio ( $R_{s}$) decreases in case of being the partition between the two intake ports. And also the mass flowrate through the tangential intake port is 19.0% and 7.7% more than that of the helical intake port in case of the two intake ports with and without partition respectively.ively.

4밸브 디젤기관의 흡기포트 편심이 실린더 내 선회비 특성에 끼치는 영향에 관한 연구 (A Study on the Effects of Intake Port Eccentricity on the In-cylinder Swirl Ratio Characteristics in a 4 Valve Diesel Engine)

  • 이지근;강신재;노병준
    • 한국자동차공학회논문집
    • /
    • 제5권5호
    • /
    • pp.157-169
    • /
    • 1997
  • The effects of intake port eccentricity on the characteristics of in-cylinder swirl ratio in a 4-valve diesel engine having the two intake ports; one is a helical intake port and the other is a tangential intake port were investigated by using the ISM(impulse swirl meter) in steady flow test rig. Swirl ratio($R_s$) and mean flow coefficient($C_{f(mean)}$) with valve eccentricity ratio($N_y$) and axial distance(Z/B) were measured. As the results from this experiment, the characteristics of in-cylinder swirl ratio formed by a 4-valve cylinder head were largely affected by intake port eccentricity. There is a difference in the mass flowrate through the two intake ports, and the mass flowrate through the tangential intake port is 19% more than that of the helical intake port. Therefore, we could know that the effects of the mass flowrate ratio through each intake port besides intake port shape should be conidered.

  • PDF

자동차용 블록식 온도감응 팽창밸브의 모델링 (Modelling of an Automotive Block Type Thermostatic Expansion Valve)

  • 원성필
    • 설비공학논문집
    • /
    • 제23권4호
    • /
    • pp.251-258
    • /
    • 2011
  • The objective of this study is to propose two empirical correlations to predict the mass flow rate through an automotive block type thermostatic expansion valve and then to evaluate the correlations. The first correlation is deduced by modifying the basic equation of the orifice meter for the mass flow rate and the second correlation is deduced by using the Buckingham's ${\pi}$ theorem. The first correlation showed very good agreement on the measured data for R134a, given by Monforte. Average relative deviation and standard deviation of it are 2.5% and 1.6%, respectively. The second correlation agreed on the same measured data with a little greater deviations. The two correlations may apply to common expansion valves which have different geometrical sizes of the same shape.

2004년 5-6월 가막만의 수괴분포 및 조류 특성 (Water mass and Tidal current of Karnak Bay In May-June 2004)

  • 이문옥;김병국;김종규
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.143-148
    • /
    • 2004
  • In order to see physical characteristics of water masses and tidal currents in Gamak Bay, some field surveys have been conducted using ADCP, Aanderaa current meter and CTD from May 17 to June 3, 2004. The northwest of the bay appeared to have a high temperature and a high salinity so that it coincided with the previous results. The distribution of temperature and salinity seemed to reflect the characteristics of water masses. At the south mouth of the bay, a northwestward-southeastward flow was dominant at the surface layer while a northeastward-southwestward flow was dominant at the bottom layer.

  • PDF

초임계 영역에서 수평관내 $CO_2$ 열전달과 압력강하 (The heat transfer and pressure drop characteristics of $CO_2$ during supercritical region in a horizontal tube)

  • 이동건;오후규;김영률;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권3호
    • /
    • pp.500-508
    • /
    • 2004
  • The heat transfer coefficients during gas cooling process of carbon dioxide in a horizontal tube were investigated. The experiments are conducted without oil in the refrigerant loop. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater, and a gas cooler(test section). The water loop consists of a variable-speed pump, an isothermal tank, and a flow meter. The gas cooler is a counterflow heat exchanger by cooled water flowing in the annulus. The $CO_2$ flows in the horizontal stainless steel tube. which is 9.53mm in O.D. and 7.75mm in I.D. The gas cooler is 6 [m] in length. which is divided into 12 subsections, respectively. The experimental conditions considered in the study are following range of variables : refrigerant temperature is between 20 and $100^{\circ}C$. mass fluxes ranged from 200 to 400kg/($m^2$.s), average pressure varied from 7.5 to 10.0MPa. The main results were summarized as follows : The friction factors of $CO_2$ in the gas cooler show a relatively good agreement with those predicted by Blasius' correlation. The local heat transfer coefficient in the gas cooler has compared with most of correlations, which are the famous ones for forced convection heat transfer of turbulent flow. The results show that the local heat transfer coefficient of gas cooler agrees well with the correlation by Bringer-Smith except that at the region near pseudo critical temperature. while that at the near pseudo critical temperature is higher than the correlation.