• Title/Summary/Keyword: Mass flow meter

Search Result 124, Processing Time 0.028 seconds

The Study to Find Causes for Measuring Differences of Hydrogen Fillings in Hydrogen Refueling Station (수소충전소의 연료 계량 방법에 따른 계량 오차가 발생하는 원인 고찰)

  • LEE, TAECK HONG;KANG, BYOUNG WOO;LEE, EUN WOUNG;CHUNG, JIN BAE;HONG, SUK JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.1
    • /
    • pp.32-40
    • /
    • 2018
  • There has been an measuring errors between state of charge (SOC; kg) value and mass flow meter (MFM) value in dispenser for hydrogen refueling station. Finally, we observed average 15.5% weight difference between these two values and the MFM readings show a 15.5% higher readout of the SOC readings. Each car was charged with average 2.66 kg of hydrogen fuel during this period. In the initial charging of the day shows less measuring value than the final charging with the maximum 0.038 kg times number of filling. There is no effects of atmosphere temperature change for the hydrogen filled weight during one full year such as January's cold winters and August's hot summers.

A Study on the Variation of Unit Price of Hydrogen Fuel by Difference of Fuel Measuring Method (수소 충전소 연료계량방법의 차이에서 발생하는 연료단가의 상이점에 대한 고찰)

  • LEE, TAECK HONG;KANG, BYOUNG WOO;LEE, EUN WOUNG;BAE, CHUNG JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.3
    • /
    • pp.279-286
    • /
    • 2017
  • Korea government decides to build one hundred hydrogen refueling stations (HRS) until 2020 and tries to disseminate HRS and boosts HRS market in korea. Naepo HRS in chungnam province has been operated for last one full year of 2016 and recorded 2,520 times full charge for the hydrogen fuel cell powered vehicles and total 6,016 kg hydrogen fueling for the 25 units of hydrogen fuel cell powered vehicles. Raw fuel of hydrogen from tube trailer measured by pressure, converting into weight of hydrogen and shows 19.6% surplus with final charged weight by dispenser. This result is caused measuring errors. Measured charged errors between dispenser and Mass flow meter was determined 13.13%.

Mass Flow Rate Measurement of Pulsating Flow in a Twin-Scroll Turbocharger (트윈스크롤 터보과급기에서 맥동유동의 질량유량 측정)

  • Chung, Jin-Eun;Jeon, Se-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.723-729
    • /
    • 2019
  • Turbochargers are an effective device to reduce the fuel consumption. In this study, the mass flow rate of pulsating flow in the twin-scroll turbocharger for the gasoline engine of passenger vehicles was measured. Pulsating flow was achieved using a pulse generator and the mass flow rate of the unsteady pulsating flow was analyzed by comparing it with those of the steady flow. The pulse generator consisted of a rotating upper plate and a fixed lower plate. To measure the mass flow rate of unsteady flow, the orifice flow meter equipped with the difference pressure transducer was used. To analyze the low speed performance of the turbocharger, the measurement was carried out in the speed of turbocharger from 60,000rpm to 100,000rpm. The mass flow parameters of the unsteady pulsating flow showed a large difference compared to those of the steady flow. Those of the unsteady flow showed the hysteresis loop surrounding the mass flow parameters of the steady flow and the maximum variation of the mass flow parameters were 5.0 times those of the steady flow. This phenomenon is the result of the filling and emptying the turbine volute space due to pulsating flow.

A Study on Lifting Characteristics of Air-Lift Pump (공기양정(Air-Lift)펌프의 양수특성에 관한 연구)

  • Kim, Dong-Kyun;Lee, Cheol-Jae;Bae, Suk-Tae;Cho, Dae-Hwan
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3B
    • /
    • pp.14-21
    • /
    • 1999
  • As an effective means to convey crushed materials from seabed to onboard ship and to raise hazardous or abrasive liquids, air-lift pump provides a reliable mechanism due to its simple configuration and easy-to-operate principle. The present study is focused on investigation of related performance by the analysis program based on the gas-liquid two-phase flow in circular pipes. The program covers pump operating in isothermal and vertical two-phase flow with Newtonian liquids. It is summarized as important result that an optimum air mass flow rate exists for the maximum lifted liquid mass flow rate in terms of a given submergence rates. The comparison between riser performance of the conveyed liquid flow rate calculated by the computer program and measured data with large scale air lift pump system constructed in 200 meter depth vertical tank reveals similar distribution.

  • PDF

A Study on the Flow Rate Performance of Plunger-Type High-Pressure Pump for Compression Ignition Engine Using DME as Fuel (DME를 연료로 하는 압축 착화 엔진 용 플런저식 고압펌프의 유량 성능 연구)

  • Jeong, Jaehee;Lee, Sejun;Yu, Donggyu;Lim, Ocktaeck
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.4
    • /
    • pp.1-8
    • /
    • 2022
  • DME, a clean fuel that is being studied as an alternative fuel for diesel engines, can reduce exhaust gas, which is the one of the crucial problems of diesel engines, and has a very high cetane number and high oxygen content. DME is a fuel has properties similar with LPG and can use the infrastructure of LPG. In this study, The target was to build a database of basic data on the mass flow rate discharged for the performance evaluation of the plunger-type high pressure pump. In this study, the mass flow rate of the DME plunger type high pressure pump was analyzed by changing the common rail pressure and the motor rotation speed. The experimental conditions were the common rail pressure was changed from 300 to 500 bar and the motor rotation speed was changed from 300 to 1000 rpm. In addition, basic mass flow data were constructed to high-pressure pumps for DME. As a result of the experiment, in both cases the mass flow rate was increased.

A study on the effects of intake port eccentricity and a partition between the two intake ports on the in-cylinder swirl characteristics in a valve diesel engine (4밸브 디젤기관의 흡기포트 편심과 두 흡기포트 사이의 격막이 실린더 내 선회 특성에 미치는 영향에 관한 연구)

  • Lee, Ji-Geun;Gang, Sin-Jae;No, Byeong-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.7
    • /
    • pp.948-961
    • /
    • 1997
  • The effects of intake port eccentricity and a partition between the two intake ports on the incylinder swirl characteristics in a 4 valve diesel engine having the two intake ports, one is a helical intake port and the other is a tangential intake port, were investigated by using the impulse swirl meter(ISM) in a steady flow test rig. Mean flow coefficient ( $C_{f(mean)}$, swirl ratio ( $R_{s}$) and the mass flowrate through the two intake ports with and without intake port partition were measured. The results showed that the characteristics of in-cylinder swirl ratio formed by a 4-valve cylinder head were largely affected by valve eccentricity ratio ( $N_{y}$) and the existence of an intake port partition between the two intake ports. Mean flow coefficient ( $C_{f(mean)}$) increases and swirl ratio ( $R_{s}$) decreases in case of being the partition between the two intake ports. And also the mass flowrate through the tangential intake port is 19.0% and 7.7% more than that of the helical intake port in case of the two intake ports with and without partition respectively.ively.

A Study on the Effects of Intake Port Eccentricity on the In-cylinder Swirl Ratio Characteristics in a 4 Valve Diesel Engine (4밸브 디젤기관의 흡기포트 편심이 실린더 내 선회비 특성에 끼치는 영향에 관한 연구)

  • 이지근;강신재;노병준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.5
    • /
    • pp.157-169
    • /
    • 1997
  • The effects of intake port eccentricity on the characteristics of in-cylinder swirl ratio in a 4-valve diesel engine having the two intake ports; one is a helical intake port and the other is a tangential intake port were investigated by using the ISM(impulse swirl meter) in steady flow test rig. Swirl ratio($R_s$) and mean flow coefficient($C_{f(mean)}$) with valve eccentricity ratio($N_y$) and axial distance(Z/B) were measured. As the results from this experiment, the characteristics of in-cylinder swirl ratio formed by a 4-valve cylinder head were largely affected by intake port eccentricity. There is a difference in the mass flowrate through the two intake ports, and the mass flowrate through the tangential intake port is 19% more than that of the helical intake port. Therefore, we could know that the effects of the mass flowrate ratio through each intake port besides intake port shape should be conidered.

  • PDF

Modelling of an Automotive Block Type Thermostatic Expansion Valve (자동차용 블록식 온도감응 팽창밸브의 모델링)

  • Won, Sung-Pil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.251-258
    • /
    • 2011
  • The objective of this study is to propose two empirical correlations to predict the mass flow rate through an automotive block type thermostatic expansion valve and then to evaluate the correlations. The first correlation is deduced by modifying the basic equation of the orifice meter for the mass flow rate and the second correlation is deduced by using the Buckingham's ${\pi}$ theorem. The first correlation showed very good agreement on the measured data for R134a, given by Monforte. Average relative deviation and standard deviation of it are 2.5% and 1.6%, respectively. The second correlation agreed on the same measured data with a little greater deviations. The two correlations may apply to common expansion valves which have different geometrical sizes of the same shape.

Water mass and Tidal current of Karnak Bay In May-June 2004 (2004년 5-6월 가막만의 수괴분포 및 조류 특성)

  • Lee Moon-Ock;Kim Byeong-Kuk;Kim Jong-Kyu
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.143-148
    • /
    • 2004
  • In order to see physical characteristics of water masses and tidal currents in Gamak Bay, some field surveys have been conducted using ADCP, Aanderaa current meter and CTD from May 17 to June 3, 2004. The northwest of the bay appeared to have a high temperature and a high salinity so that it coincided with the previous results. The distribution of temperature and salinity seemed to reflect the characteristics of water masses. At the south mouth of the bay, a northwestward-southeastward flow was dominant at the surface layer while a northeastward-southwestward flow was dominant at the bottom layer.

  • PDF

The heat transfer and pressure drop characteristics of $CO_2$ during supercritical region in a horizontal tube (초임계 영역에서 수평관내 $CO_2$ 열전달과 압력강하)

  • 이동건;오후규;김영률;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.500-508
    • /
    • 2004
  • The heat transfer coefficients during gas cooling process of carbon dioxide in a horizontal tube were investigated. The experiments are conducted without oil in the refrigerant loop. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater, and a gas cooler(test section). The water loop consists of a variable-speed pump, an isothermal tank, and a flow meter. The gas cooler is a counterflow heat exchanger by cooled water flowing in the annulus. The $CO_2$ flows in the horizontal stainless steel tube. which is 9.53mm in O.D. and 7.75mm in I.D. The gas cooler is 6 [m] in length. which is divided into 12 subsections, respectively. The experimental conditions considered in the study are following range of variables : refrigerant temperature is between 20 and $100^{\circ}C$. mass fluxes ranged from 200 to 400kg/($m^2$.s), average pressure varied from 7.5 to 10.0MPa. The main results were summarized as follows : The friction factors of $CO_2$ in the gas cooler show a relatively good agreement with those predicted by Blasius' correlation. The local heat transfer coefficient in the gas cooler has compared with most of correlations, which are the famous ones for forced convection heat transfer of turbulent flow. The results show that the local heat transfer coefficient of gas cooler agrees well with the correlation by Bringer-Smith except that at the region near pseudo critical temperature. while that at the near pseudo critical temperature is higher than the correlation.