• Title/Summary/Keyword: Mass Transfer Number

Search Result 397, Processing Time 0.031 seconds

Analysis of Vibration for the Pre-twisted Beam Considering the Effect of Rotary Inertia Using the Transfer Matrix Mathod (전달행렬법을 이용하여 비틀림 각과 회전관성을 고려한 보의 진동해석)

  • Lee, Jung Youn
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.2
    • /
    • pp.217-224
    • /
    • 2016
  • In this study, a transfer matrix method (TMM) for a twisted uniform beam considering the effect of rotary inertia is developed, and the differential equation and the displacements and forces are derived from Hamilton's principle. The particular transfer matrix is derived by applying the distributed mass and transcendental function while using a local coordinate system. In addition, the results obtained from this method are independent for a number of subdivided elements, and this method can determine the exact solutions for the free vibration characteristics of a twisted uniform Rayleigh beam. To validate the accuracy of the proposed TMM, the computed results are compared with those reported in the existing literature, and the comparison results indicate notably good agreement. In addition, the method is used to investigate the effects of rotary inertia for a twisted beam.

Analysis of Natural Convection Heat Transfer and Solidification of a Two-Layered Pool (2층으로 성층화된 풀 내에서의 자연대류 열전달과 고화현상에 대한 연구)

  • Kim J.;Kang K. S.;Kim S. B.;Kim H. D.
    • Journal of computational fluids engineering
    • /
    • v.6 no.1
    • /
    • pp.1-13
    • /
    • 2001
  • The natural convection heat transfer and solidification in a stratified pool are studied. The flow and heat transfer characteristics in a heat generating pool are compared between single-layered and double-layered pools. And local Nusselt number distributions on outer walls are obtained to consider thermal loads on a vessel wall. The cooling and solidification of Al₂O₃/Fe melt in a hemispherical vessel are simulated to study the mechanism of heat transfer and temperature distribution. A unstructured mesh is chosen for this study because of the non-orthogonality originated from the boundaries of double-layered pool. Interface between the layers is modeled to be fixed. With this assumption mass flux across the interface is neglected, but shear force and heat flux are considered by boundary conditions. The colocated cell-centered finite volume method is used with the Rhie-Chow interpolation to compute cell face velocity. To prevent non-physical solutions near walls in case body force is large the wall pressure is extrapolated by the way to include body force. The numerical solutions calculated by current method show that averaged downward heat flux of the double-layered pool increases compared to single-layered pool and maximum temperature occurs right below the interface of the layers.

  • PDF

Evaluation of correlations for prediction of onset of heat transfer deterioration for vertically upward flow of supercritical water in pipe

  • Sahu, Suresh;Vaidya, Abhijeet M.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1100-1108
    • /
    • 2021
  • Supercritical water has great potential as a coolant for nuclear reactor. Its use will lead to higher thermal efficiency of Rankine cycle. However, in certain conditions heat transfer may get deteriorated which may lead to undesirable high clad surface temperature. It is necessary to estimate the operating conditions in which heat transfer deterioration (HTD) will take place, so as to establish thermal margins for safe reactor operation. In the present work, the heat flux corresponding to onset of HTD for vertically upward flow of supercritical water in a pipe is obtained over a wide range of system parameters, namely pressure, mass flux, and pipe diameter. This is done by performing large number of simulations using an in-house CFD code, which is especially developed and validated for this purpose. The identification of HTD is based on observance of one or more peak/s in the computed wall temperature profile. The existing correlations for predicting the onset of HTD are compared against the results obtained by present simulations as well as available sets of experimental data. It is found that the prediction accuracy of the correlation proposed by Dongliang et al. is best among the existing correlations.

Development a Following of Serum Addition In Vitro Culture and Embryo Transfer (체외 배양액의 조성과 혈청의 첨가가 한우 체외 수정란의 발달과 임신율에 미치는 효과)

  • Choi, Soo-Ho;Park, Yong-Soo;Lee, Joon-Hee;Kang, Tae-Yeong;Kim, Joo-Heon;Rho, Gyu-Jin
    • Journal of Embryo Transfer
    • /
    • v.23 no.1
    • /
    • pp.51-57
    • /
    • 2008
  • The present study investigated the efficient methods to produce in vitro Hanwoo embryos, and to improve the pregnancy rate. The developmental rate, total cell number and ICM ratio of in vitro embryos were compared amongst different culture media. Comparisons were also made on the status of recipients, pregnancy rate along with day of transfer after the estrus. Development of embryos into blastocyst stage in IVMD101 supplemented with 5% fetal bovine serum (FBS) group was significantly higher (34.2%) than that of TCM-199 supplemented with 5% FBS (26.8%) and IVMD101 without FBS (25.9%) (p<0.05). The development rate to blastocyst stage was significantly faster in IVMD101(5% FBS) than that of other groups ($0.2{\sim}2.3%$) (p<0.05). The average number of inner cell mass and trophectoderm were similar among treatment groups, which were $36.0{\sim}44.7$ and $83.3{\sim}106.7$. However, total cell number in IVMD101(5% FBS and 0% FBS) was significantly higher than that of TCM199(5% FBS). There were no differences in the pregnancy rate among treatment groups (32.0%, 33.9% and 28.6%, respectively). However, the pregnancy rate of Day 6 embryos cultured in IVMD101(5% FBS) was significantly (p<0.01) higher than IVMD101 without FBS and TCM-199 + 5% FBS (38.0% vs. 17.2% and 32.4%, respectively). No significant difference was observed for the pregnancy rate between heifer and cow transferred with Day 6 embryos cultured in IVMD 101(5% FBS) (42.7% and 39.3%, respectively). However, there was a significant difference of pregnancy rate (p<0.05) in heifer between one and two embryos transferred (31.4% and 41.9%). There was no difference of pregnancy rate among transfer days after estrus between heifer and cow, but the pregnancy rate of transfer to heifer with day 6 after estrus was significantly higher (p<0.05) than that of day 7 and 8 (22.2% vs. 49.0% and 38.7% respectively). Based on the above findings, there is a possibility to produce in vitro produced embryos cultured in IVMD101(5% FBS) showed higher blastocyst rate and the increased cell number. In terms of the pregnancy rate of in vitro produced embryos, the highest pregnancy rate was observed when two embryos were cultured in IVMD101(5% FBS) and transferred.

The Guidelines for Station Layouts and Their Assessments in Railroad Transfer Centers (철도 환승센터의 시설배치기준 및 평가방안)

  • Lee, Jong kuk;Kim, Sigon;Lim, Kwangkyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5D
    • /
    • pp.597-604
    • /
    • 2009
  • The mass transit networks in Korea, such as buses, metro and subway, are co-related and the number of transfer points, in which a lot of pedestrian movement is generated, are rising. The functions of the transfer centers, in which several travel modes cross at a point, have to include convenience and comfort for pedestrians using the transfer centers, and such functions can make transit a more attractive travel option and thus eventually contribute to increases in ridership. However, the guidelines for station layouts and their assessments in transfer stations are not suggested so far. So the pedestrian pattern data (pedestrian walking distances and times, pedestrian approaching distances and times, pedestrian walking paths in the inside of stations) was collected and analyzed. Based on the results of the analysis, the ways to measure the quality of comfort for those who using transfer facilities were suggested using the times that pedestrians consume to transfer from a travel mode to another. The walking time of pedestrians at the inside of stations was also measured by pre-selected pedestrian pathways as the guidelines for station layout assessment in transfer facilities.

Effect of degree of superheat of LiBr aqueous solution on the vapor absorption process for an air-cooled absorption cooling system (공냉형 흡수식 냉방 시스템에서 LiBr 수용액의 과열도가 증기 흡수에 미치는 영향)

  • Kim, S.C.;Oh, M.D.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.122-133
    • /
    • 1997
  • Numerical analysis using finite volume method has been carried out to examine the effect of degree of superheat of LiBr aqueous solution on heat and mass transfer occurred in absorption process. According to the result of this study, it was found that refrigerant vaper was generated at the entrance region of absorber when LiBr aqueous soltion was superheated. As the degree of superheat increases, heat transfer rate increases and vapor absorption rate decreases. The increase in averaged Nusselt and Sherwood numbers could be found as film Reynolds number increases. The larger the degree of superheat, the greater the averaged Nusselt and Sherwood numbers.

  • PDF

A Study on the Prediction of Combustion Gas Behavior Induced by Fire in a Building (건물내 화재에 의한 연소가스 거동 예측에 관한 연구)

  • Pak, H.Y.;Park, K.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.267-281
    • /
    • 1994
  • The Combustion gas behavior induced by fire in a building is numerically investigated. The typical building for this analysis is partially divided by a vertical baffle projecting from the ceiling. The solution procedure includes the low Reynolds number ${\kappa}-{\varepsilon}$ model for the turbulent flow and the discrete ordinates method is used for the calculation of radiative heat transfer equation. The effects of the location and size of fire source and baffle length on velocity and temperature distributions, species mass fraction and flame location are analyzed. As the results of this study, it is found that the case when the fire source is located at the vertical wall is more dangerous than at the bottom wall in view of the combustion products and flame location. It is also found that the radiation effect cannot be neglected in analyzing the building in fire.

  • PDF

INFLUENCE OF HALL CURRENT AND HEAT SOURCE ON MHD FLOW OF A ROTATING FLUID IN A PARALLEL POROUS PLATE CHANNEL

  • VENKATESWARLU, M.;UPENDER REDDY, G.;VENKATA LAKSHMI, D.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.22 no.4
    • /
    • pp.217-239
    • /
    • 2018
  • This paper examined the MHD and thermal behavior of unsteady mixed convection flow of a rotating fluid in a porous parallel plate channel in the presence of Hall current and heat source. The exact solutions of the concentration, energy and momentum equations are obtained. The influence of each governing parameter on non dimensional velocity, temperature, concentration, skin friction coefficient, rate of heat transfer and rate of mass transfer at the porous parallel plate channel surfaces is discussed. During the course of numerical computation, it is observed that as Hall current parameter and Soret number at the porous channel surfaces increases, the primary and secondary velocity profiles are increases while the primary and secondary skin friction coefficients are increases at the cold wall and decreases at the heated wall. In particular, it is noticed that a reverse trend in case of heat source parameter.

Flow performance of cryomodules in C-ADS Injector II

  • WAN, Yu-Qin;HAN, Yan-Ning;Zhang, Jun-Hui;Li, Chao
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.74-78
    • /
    • 2022
  • Two β=0.10 cryomodules are required for the China Accelerator Driven Subcritical System (C-ADS) injector II accelerator. Flow design is of great importance in the performance of cryomodules, including thermal design, flow distribution, pressure drop and so on. This paper will study convection heat transfer of helium and relation among the pipe diameter, mass flow rate and Reynolds number. Furthermore, the influence of flow geometries on pressure drop and flow distribution will also be done. It was found that the theoretical flow distribution were in good agreement with the experimental data.

The Guidelines for Station layouts and Their Assessments in Railroad Transfer Centers (철도 환승센터의 시설배치기준 및 평가방안)

  • Lee, Jong-Kuk;Kim, Si-Gon;Lim, Kwang-Kyun
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1308-1317
    • /
    • 2009
  • The mass transit networks in Korea, such as buses, metro and subway, are co-related and the number of transfer points, in which a lot of pedestrian movement is generated, are rising. The functions of the transfer centers, in which several travel modes cross at a point, have to include convenience and comfort for pedestrians using the transfer centers, and such functions can make transit a more attractive travel option and thus eventually contribute to increases in ridership. However, the guidelines for station layouts and their assessments in transfer stations are not suggested so far. So the pedestrian pattern data (pedestrian walking distances and times, pedestrian approaching distances and times, pedestrian walking paths in the inside of stations) was collected and analyzed. Based on the results of the analysis, the ways to measure the quality of comfort for those who using transfer facilities were suggested using the times that pedestrians consume to transfer from a travel mode to another. The walking time of pedestrians at the inside of stations was also measured by pre-selected pedestrian pathways as the guidelines for station layout assessment in transfer facilities.

  • PDF