• Title/Summary/Keyword: Mass Transfer Model

Search Result 641, Processing Time 0.029 seconds

Mathematical Models of Substrate Utilization within Bacterial Films (미생물막(微生物膜)을 이용(利用)한 폐수처리(廢水處理)의 수학적(數學的) 모델에 관한 연구(研究))

  • Chung, Tai Hak
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.43-51
    • /
    • 1981
  • A model of substrate utilization witbin bacterial films has been developed and simulated for a better understanding of fixed film treatment processes. The model consists of two parts, a deep biofilm and a thin biofilm, which are classified based on substrate penetration into the biofilm. Substrate concentration and flux within a biofilm can be computed from the model. Three dimensionless parameters, ${\phi}_1$, ${\phi}_2$ and $\bar{S}_b$ were obtained during model construction, and the substrate concentration and flux can be expressed in terms of these parameters. It has been found that an. increase of ${\phi}_1$ or a decrease of ${\phi}_2$ results in an increase of treatment efficiencies. It has also been found that systems maintaining high efficiencies belong to a deep biofilm. Among the constants involved, the mass transfer coefficient is the only controllable term and it depends Largely on fluid velocity near the biofilm surface. Substrate removal efficiency may be increased with an increase of fluid velocity for a biofilm of fixed depth. However, film depth is decreased due to sloughing with increasing velocity, and the system reaches a new steady state. Because changes in film depth are not well defined quantitatively yet, the efficiency can not be clearly described at a new steady state.

  • PDF

Investigation of Optimal Construction Procedures for Concrete Underpass Structures Considering Heat of Hydration (수화열을 고려한 콘크리트 지하차도 적정 시공법 분석)

  • An, Zu-Og;Kim, Seong-Min;Kim, Dong-Ryun
    • International Journal of Highway Engineering
    • /
    • v.11 no.2
    • /
    • pp.229-238
    • /
    • 2009
  • This paper describes the methods to propose the optimal material properties and construction steps that prevent cracks due to the thermal stresses induced by the hydration heat under the construction of the concrete underpass structures. To achieve the goal of this study, the heat transfer theories were employed and the three-dimensional finite element model of the underpass structure was developed and used for the structural analyses. If the volume of the concrete member that is placed at one time is significantly large, the member is assumed to be the mass concrete and is easy to induce cracks. In order to minimize the cracks during the construction, two different methods can be utilized: one is to arrange the construction steps optimally and the other is to change the materials to reduce the probability of the crack occurrence. In this study, the analyses were performed by considering the changes in material properties with time, the characteristics of the hydration heat generation for cements and admixtures, the volume of the concrete placement at one time, and the environmental conditions.

  • PDF

Development of ACBIO: A Biosphere Template Using AMBER for a Potential Radioactive Waste Repository (AMBER를 이용한 방사성폐기물처분장 생태계 평가 템플릿 ACBIO 개발)

  • Lee Youn-Myoung;Hwang Yongsoo;Kang Chul-Hyung;Hahn Pil-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.3
    • /
    • pp.213-229
    • /
    • 2005
  • Nuclides in radioactive wastes are assumed to be transported in the geosphere by groundwater and probably discharged into the biosphere. Quantitative evaluation of doses to human beings due to nuclide transport in the geosphere and through the various pathways in the biosphere is the final step of safety assessment of the radioactive waste repository. To calculate the flux to dose conversion factors (DCFs) for nuclides appearing at GBIs with their decay chains, a template ACBIO which is an AMBER case file based on mathematical model for the mass transfer coefficients between the compartments has been developed considering material balance among the compartments in biosphere and then implementing to AMBER, a general and flexible software tool that allows to build dynamic compartment models. An illustrative calculation with ACBIO is shown.

  • PDF

Rhodopsedomonas palustris P4를 이용한 Trickle Bed Reactor에서의 일산화탄소와 물로부터 연속적인 수소생산

  • Park, Ji-Yeong;Lee, Tae-Ho;Park, Seong-Hun
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.241-244
    • /
    • 2000
  • Continuous $H_2$ production from CO and water was studied in a trickle bed reactor(TBR) using Rhodopspedomonas palustris P4. To achieve high cell density, R. palustris P4 were cultivated by a fed-batch culture mode under chemoheterotrophic and aerobic condition, and final cell concentration was 13 g/L. TBR could provide sufficient residence time for CO to contact with cell suspension circulating TBR. The maximum CO uptake rate was found to be 16 mmol/L/hr at gas retention time of 50 min and CO partial pressure of 0.4 atm. In our correlation of the experimental data with mathematical model of TBR, the TBR operation with P4 was found to be lie in an intermediate state between mass transfer limitation and kinetic limitation. Due to the high cell density as well as hydrogen production activity in this study, TBR operation showed a superior performance to other previous reports on microbial hydrogen production.

  • PDF

Numerical Study on Comparison of Serpentine and Parallel Flow Channel in High-temperature Proton Exchange Membrane Fuel Cells (고온형 고분자전해질형 연료전지에서의 사형 유로와 평행 유로 성능비교에 대한 수치해석적 연구)

  • AHN, SUNGHA;OH, KYEONGMIN;JU, HYUNCHUL
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.1
    • /
    • pp.41-55
    • /
    • 2018
  • General polymer electrolyte fuel cell (PEMFC) operates at less than $80^{\circ}C$. Therefore liquid phase water resulting from electrochemical reaction accumulates and floods the cell which in turn increases the mass transfer loss. To prevent the flooding, it is common to employ serpentine flow channel, which can efficiently export liquid phase water to the outlet. The major drawback of utilizing serpentine flow channel is the large pressure drop that happens between the inlet and outlet. On the other hand, in the high temperature polymer electrolyte fuel cell (HT-PEMFC), since the operating temperature is 130 to $180^{\circ}C$, the generated water is in the state of gas, so the flooding phenomenon is not taken into consideration. In HT-PEMFCs parallel flow channel with lower pressure drop between the inlet and outlet is employed therefore, in order to circulate hydrogen and air in the cell less pumping power is required. In this study we analyzed HT-PEMFC's different flow channels by parallel computation using previously developed 3-D isothermal model. All the flow channels had an active area of $25cm^2$. Also, we numerically compared the performance of HT-PEMFC parallel flow channel with different manifold area and Rib interval against the original serpentine flow channel. Results of the analysis are shown in the form of three-dimensional contour polarization curves, flow characteristics in the channel, current density distribution in the Membrane, overpotential distribution in the catalyst layer, and hydrogen and oxygen concentration distribution. As a result, the performance of a real area fuel cell was predicted.

Performance Analysis of a Desiccant Rotor for Rotational Period in a Desiccant Cooling System (제습냉방시스템의 제습로터 회전주기변화에 따른 제습성능해석)

  • Pi, Chang-Hun;Kang, Byung-Ha;Chang, Young-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.5
    • /
    • pp.523-531
    • /
    • 2012
  • The performance simulation of a desiccant rotor, which is a core component of a desiccant cooling system, was conducted on the basis of a theoretical solution of the heat and mass transfer process in the rotor. The simulation model was validated by comparing simulation results with experimental data; reasonable agreement was observed. The effect of the rotation speed on the performance of the desiccant rotor was investigated for various operation conditions: temperature (50 to $70^{\circ}C$), humidity ratio (0.01 to 0.02 kg/kg DA), and flow rate of regeneration air. The optimum rotation speed was determined from the maximum moisture removal capacity (MRC) of the desiccant rotor, and it was found to vary with the operation conditions. Further, the correlation for the optimum rotation speed was determined by regression analysis.

Effects of activated carbon packing length in PSA process for production of high-purity hydrogen (고순도 수소제조를 위한 PSA 공정에서 활성탄 충전길이 효과)

  • Paik, Eun-gyu;Choi, Min-Ho;Suh, Sung-Sup
    • Clean Technology
    • /
    • v.7 no.2
    • /
    • pp.127-132
    • /
    • 2001
  • The effects of activated-carbon (AC) packing length on the Pressure Swing Adsorption (PSA) performance was investigated for the hydrogen separation from the multicomponent mixture gas. Linear driving force model was used to describe mass transfer between two phase and coupled Langmuir isotherm was used for each component as a nonlinear adsorption isotherm. When two adsorbents with a different adsorption capacity were packed consecutively in one bed, it is very important to determine the packing ratio of zeolite to activated carbon affecting the purity and recovery of the product. The activated carbon packing length in adsorption tower of 120 cm was determinated by the ending point of $CO_2$ contration. The optimum length of an activated carbon layer was 65 cm for production of high-purity hydrogen.

  • PDF

Optimization of Operating Condition on Gasification of Ash-free Coal by Using the Sensitivity Analysis of ASPEN Plus (민감도 해석을 통한 무회분 석탄의 가스화 최적 운전조건 도출)

  • Park, Sung-Ho;Jeon, Dong-Hwan;Yun, Sung-Phil;Chung, Seok-Woo;Choi, Ho-Kyung;Lee, Si-Hyun
    • Clean Technology
    • /
    • v.20 no.3
    • /
    • pp.298-305
    • /
    • 2014
  • Ash included in coal can cause environmental pollution and it can decrease efficiency of mass and heat transfer by getting scorched and stick in the facilities operated at high temperature. To solve this problem, a feasibility study on pulverized coal fired power plant and integrated gasification combined cycle (IGCC) using the AFC (Ash-Free Coal) as well as the development to remove the ash from the coal was conducted. In this research, optimization of operating condition was proposed by using sensitivity analysis of ASPEN $Plus^{(R)}$ to apply the coal containing under the 200 ppm ash for integrated gasification combined cycle. Particularly, the coal gasification process was classified as three parts : pyrolysis process, volatile matter combustion process and char gasification process. The dimension and operating condition of 1.5 ton/day class non-slagging gasifier are reflected in the coal gasification process model.

토양내 총 NAPL과 공기접촉 NAPL의 측정을 위한 분별 NAPL 분배 추적자 기술의 개발

  • 최경민;김헌기
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.29-32
    • /
    • 2004
  • Gaseous partitioning tracer test has been used for determining the volume and spatial distribution of residual non-aqueous phase liquid (NAPL) in the unsaturated soils. In this study, an experimental method for measuring the content of gas-exposed NAPL as well as that of total NAPL in a sand during air sparging was developed. Two different gaseous phase NAPL-partitioning tracers were used; n-pentane, with very low water solubility, was used as the tracer that partitions into NAPL that is only in contact with the mobile gas, and chloroform, with fairly good water solubility, was selected for detecting total NAPL content in the sand. Helium and difluromethanewere used as the non- reactive tracer and water-partitioning tracers, respectively. Using n-decane as a model NAPL (NAPL saturation of 0.018), 25.6% of total NAPL was detected by n-pentane at the water saturation of 0.68. Oniy 9.1% of total NAPL was detected by n-pentane at the water saturation of 0.84. This result implies that the quantity of gas-exposed NAPL increased about three times when the water saturation decreased from 0.84 to 0.68. At the water saturation of 0.68, more than 90% of total NAPL was detected by chloroform while 65.8% of total NAPL was detected by chloroform at the water saturation of 0.84. Considering that the removal rate of NAPL during air sparging for NAPL-contaminated aquifer is expected to be greatly dependent upon the spatial arrangement of NAPL phase with respect to the mobile gas, this new approach may provide useful information for investigating the mass transfer process during air-driven remedial processes fer NAPL-contaminated subsurface environment.

  • PDF

Removal of Trihalomethane Using Activated Carbon (활성탄(活性炭)을 이용(利用)한 Trihalomethane의 제거(除去)에 관한 연구(研究))

  • Chung, Tai Hak;Chung, Jae Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.73-79
    • /
    • 1983
  • Activated carbon has been widely used in water and wastewater treatment for removal of trace organics. The objective of this study was to define adsorption characteristics of trihalomethane(THM) on granular activated carbon(GAC) surfaces by laboratory experiments. Synthetic samples were prepared by adding chloroform into distilled and deionized water. The experiments conducted were a batch run and isotherm studies with five different temperature-pH levels. Adsorption of THM on GAC at an equilibrium condition was well described by the Freundlich isotherm equation. Lower temperature favored the adsorption, but the effect of pH was negligible. Utilizing the results of a batch run and the isotherm results, three parameters, mass transfer coefficient, pore diffusion coefficient, and surface diffusion coefficient, were evaluated by comparing with simulation results of an adsorption model. The results also showed that the pore diffusion was much greater than the surface diffusion.

  • PDF