• Title/Summary/Keyword: Mass Spectrometry (MS)

Search Result 1,914, Processing Time 0.029 seconds

Sample Preparation for Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry

  • Kim, Jeongkwon
    • Mass Spectrometry Letters
    • /
    • v.6 no.2
    • /
    • pp.27-30
    • /
    • 2015
  • This article reviews the fundamentals of sample preparation used in matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS). MALDI is a soft ionization method used to generate analyte ions in their intact forms, which are then detected in MS analysis. MALDI-MS boasts fast analysis times and easy-to-use operation. The disadvantages of MALDI-MS include the occurrence of matrix-associated peaks and inhomogeneous distribution of analyte within the matrix. To overcome the disadvantages of MALDI-MS, various efforts have been directed such as using different matrices, novel matrix systems, various additives, and different sample preparation methods. These various efforts will be discussed in detail. This article will benefit those who would like to obtain basic knowledge of MALDI sample preparation and those who would like to use MALDI-MS in their chemical analyses.

Screening Analysis of 10 Adrenal Steroids by Matrix-Assisted Laser Desorption Ionization-Tandem Mass Spectrometry

  • Kim, Sun-Ju;Jung, Hyun-Jin;Chung, Bong-Chul;Choi, Man-Ho
    • Mass Spectrometry Letters
    • /
    • v.2 no.3
    • /
    • pp.69-72
    • /
    • 2011
  • Defective synthesis of the steroid hormones by the adrenal cortex has profound effects on human development and homeostasis. Due to the time-consuming chromatography procedure combined with mass spectrometry, the matrix-assisted laser desorption ionization method coupled to the linear ion-trap tandem mass spectrometry (MALDI-LTQ-MS/MS) was developed for quantitative analysis of 10 adrenal steroids in human serum. Although MALDI-MS can be introduced for its applicability as a high-throughput screening method, it has a limitation on reproducibility within and between samples, which renders poor reproducibility for quantification. For quantitative MALDI-MS/MS analysis, the stable-isotope labeled internal standards were used and the conditions of crystallization were tested. The precision and accuracy were 3.1~35.5% and 83.8~138.5%, respectively, when a mixture of 10 mg/mL ${\alpha}$-cyano-4-hydroxycinnamic acid in 0.2% TFA of 70% acetonitrile was used as the MALDI matrix. The limit of quantification ranged from 5 to 340 ng/mL, and the linearity as a correlation coefficient was higher than 0.988 for all analytes in the calibration range. Clinical applications include quantitative analyses of patients with congenital adrenal hyperplasia. The devised MALDI-MS/MS technique could be successfully applied to diagnosis of clinical samples.

Accurate Quantification of Saccharin Using Isotope Dilution Liquid Chromatography Mass Spectrometry (ID-LC/MS)

  • Lee, Yun-Jung;Kim, Byung-Joo;Kim, Jeong-Kwon;Ahn, Seong-Hee
    • Mass Spectrometry Letters
    • /
    • v.2 no.2
    • /
    • pp.37-40
    • /
    • 2011
  • Saccharin is a commonly used artificial sweetener in foodstuffs. However, for its carcinogenic dispute, it has been regulated by government bodies. In this study, isotope dilution mass spectrometry (ID-MS) was introduced for the accurate quantification of saccharin. To employ ID-LC/MS, we obtained its isotope analogue, $^{13}C_1$-sodium saccharin, by customized synthesis. Samples were spiked with $^{13}C_1$-sodium saccharin and analyzed with LC/MS in negative mode. Chromatographic conditions were optimized for the adequate chromatographic retention and separation of saccharin with a $C_{18}$ column. MS was operated with electrospray ionization by the selected ion monitoring (SIM) mode of $[M-H]^-$ for saccharin (m/z 182) and $[M-Na]^-$ for its isotope analogue (m/z 183). To validate the ID-LC/MS method for accurate measurement, we prepared a batch of a candidate material by sortifying quasi-tea-drinks with saccharin and analyzed samples gravimetrically fortified in various levels of concentration. The repeatability and reproducibility of this method was tested by analyzing the reference material. Result show that ID-LC/MS is a reliable method for the quantitative analysis of saccharin.

Mass Spectrometry for Metabolome Analysis

  • Wang, Xiaohang;Li, Liang
    • Mass Spectrometry Letters
    • /
    • v.11 no.2
    • /
    • pp.17-24
    • /
    • 2020
  • Metabolomics has become an important research field with many areas of applications ranging from disease biomarker discovery to global biology systems study. A key step in metabolomics is to perform metabolome analysis to obtain quantitative information on metabolic changes among comparative samples. Mass spectrometry (MS) is widely used for highly sensitive detection of many different types of metabolites. In this review, we highlight some of the more commonly used MS techniques for metabolome analysis.

Dynamic MRM Measurements of Multi-Biomarker Proteins by Triple-Quadrupole Mass Spectrometry with Nanoflow HPLC-Microfluidics Chip

  • Ji, Eun-Sun;Cheon, Mi-Hee;Lee, Ju-Yeon;Yoo, Jong-Shin;Jung, Hyun-Jin;Kim, Jin-Young
    • Mass Spectrometry Letters
    • /
    • v.1 no.1
    • /
    • pp.21-24
    • /
    • 2010
  • The development of clinical biomarkers involves discovery, verification, and validation. Recently, multiple reaction monitoring (MRM) coupled with stable isotope dilution mass spectrometry (IDMS) has shown considerable promise for the direct quantification of proteins in clinical samples. In particular, multiple biomarkers have been tracked in a single experiment using MRM-based MS approaches combined with liquid chromatography. We report here a highly reproducible, quantitative, and dynamic MRM system for validating multi-biomarker proteins using Nanoflow HPLC-Microfluidics Chip/Triple-Quadrupole MS. In this system, transitions were acquired only during the retention window of each eluting peptide. Transitions with the highest MRM-MS intensities for the five target peptides from colon cancer biomarker candidates were automatically selected using Optimizer software. Relative to the corresponding non-dynamic system, the dynamic MRM provided significantly improved coefficients of variation in experiments with large numbers of transitions. Linear responses were obtained with concentrations ranging from fmol to pmol for five target peptides.

High-Throughput Active Compound Discovery using Correlations between Activity and Mass Profiles

  • Park, Kyu-Hwan;Yoon, Kyo-Joong;Kwon, Kyung-Hoon;Kim, Hyun-Sik
    • Mass Spectrometry Letters
    • /
    • v.1 no.1
    • /
    • pp.13-16
    • /
    • 2010
  • The active components in a plant extract can be represented as mass profiles. We introduce here a new, multi-compound discovery method known as Scaling of Correlations between Activity and Mass Profiles (SCAMP). In this method, a correlation coefficient is used to quantify similarities between the extract activity and mass profiles. The method was evaluated by first measuring the anti-oxidation activity of eleven fractions of an Astragali Radix extract using DPPH assays. Next, 15 T Fouriertransform ion cyclotron resonance (FT-ICR) MS was employed to generate mass profiles of the eleven fractions. A comparison of correlation coefficients indicated two compounds at m/z 285.076 and 286.076 that were strong antioxidants. Principal component analyses of these profiles yielded the same result. FT-ICR MS, which offers a mass resolving power of 500,000, was used to discern isotopic fine structures and indicated that the molecular formula corresponding to the peak at m/z 285.076 was $C_{16}H_{13}O_5$. SCAMP in combination with high-resolution MS can be applied to any type of mixture to study pharmacological activity and is a powerful tool for active compound discovery in plant extract studies.

Structural Study of Oligosaccharides by Low Energy Collision Tandem Mass Spectrometry : Effect of the Acetylation Derivatization (저에너지 충돌 탄뎀 질량분석법을 이용한 올리고당의 연결구조 연구:아세틸화 반응이 미치는 영향)

  • Yoo Yoon, Eun Sun
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.3
    • /
    • pp.297-301
    • /
    • 1998
  • Linkage positions in oligosaccharides may be obtained by FAB CAD MS/MS (Fast Atom Bombardment Collision Activated Dissociation Mass Spectrometry/Mass Spectrometry). Acetylated derivatives of the linkage-isomeric trisaccharides exhibited more useful product ion patterns than the free trisaccharides and provided specific fragmentation patterns according to linkage positions. The reason for the useful linkage dependent spectra patterns of acetylated forms is related to the ability of each linkage in the oligosaccharides to absorb different levels of collision energy and rotational freedom of the individual glycosidic linkage.

  • PDF

Quantification of Three Prohibited Anabolic-Androgenic Steroids in Equine Urine using Gas Chromatography-Tandem Mass Spectrometry

  • Young Beom Kwak;Shaheed Ur Rehman;Hye Hyun, Yoo
    • Mass Spectrometry Letters
    • /
    • v.14 no.3
    • /
    • pp.104-109
    • /
    • 2023
  • Anabolic-androgenic steroids (AAS) are used illegally to enhance muscle development and increase strength and power. In this study, a reliable, and sensitive quantitative method was developed and validated using heptafluorobutyric acid anhydride (HFPA) derivatives for the simultaneous detection of prohibited AAS (testosterone [TS], boldenone [BD], 5α-estrane-3β,17α-diol [EAD]) using gas chromatography-tandem mass spectrometry (GC-MS/MS). For processing the samples, solid phase extraction, methanolic hydrolysis, and liquid-liquid extraction were used. For detection using mass spectrometry, the multiple reaction monitoring (MRM) mode was used with the electron ionization (EI) positive mode. The method was evaluated for selectivity, linearity, lower limit of quantification, intra- and inter-day precision, accuracy, and stability. The results showed that the method was accurate and reproducible for the quantitation of the three steroids. The developed method was finally applied to the analysis of a suspect gelding urine sample received from the Asian Quality Assurance Program (AQAP).

Quantitative measurement of salivary testosterone in Korean adults by stable isotope-dilution liquid chromatographyelectrospray-tandem mass spectrometry

  • Lee, Sang-Hoo;Kwon, Soon-Ho;Shin, Hye-Jin;Park, Ji-Myeong;Lim, Hwan-Sub;Lee, Kyoung-Ryul;Kim, Young-Jin
    • BMB Reports
    • /
    • v.43 no.11
    • /
    • pp.761-765
    • /
    • 2010
  • Salivary testosterone levels in Korean adults were quantitatively measured for the first time by liquid chromatography-electrospray-tandem mass spectrometry (LC ESI MS/MS). Salivary testosterone was separated on a multiple reaction monitoring (MRM) chromatogram within 7 min. The LC ESI MS/MS assay was validated over the linearity range of 0.01-2.00 ng/ml (r=0.99987) using testosterone-$d_3$ as an internal standard. The lower limit of quantification (LOQ) was 0.01 ng/ml. The intra- and inter-assay precisions were 1.54% to 4.09% and 0.96% to 4.29%, respectively. The mean recovery was 93.32% (range 88.43-98.05%). The validated assay was then applied to measure the salivary testosterone levels of Korean adults. In men, the salivary testosterone level collected between 9:00-11:00 am was approximately 2.8 times higher than that in women (P < 0.0001). Salivary testosterone levels in both sexes negatively correlated with age. The present assay would also be useful in measuring salivary testosterone levels in clinical laboratories.

Mass Spectrometry-Based Analytical Methods of Amatoxins in Biological Fluids to Monitor Amatoxin-Induced Mushroom Poisoning

  • Choi, Jin-Sung;Lee, Hye Suk
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.95-105
    • /
    • 2022
  • Amatoxin-induced mushroom poisoning starts with nonspecific symptoms of toxicity but hepatic damage may follow, resulting in the rapid development of liver insufficiency and, ultimately, coma and death. Accurate detection of amatoxins, such as α-, β-, and γ-amanitin, within the first few hours after presentation is necessary to improve the therapeutic outcomes of patients. Therefore, analytical methods for the identification and quantification of α-, β-, and γ-amanitin in biological samples are necessary for clinical and forensic toxicology. This study presents a literature review of the analytical techniques available for amatoxin detection in biological matrices, and established an inventory of liquid chromatography (LC) techniques with mass spectrometry (MS), ultraviolet (UV) detection, and electrochemical detection (ECD). LC-MS methods using quadrupole tandem mass spectrometry, time-of-flight mass spectrometry, and orbitrap MS are powerful analytical techniques for the identification and determination of amatoxins in plasma, urine, serum, and tissue samples, with high sensitivity, specificity, and reproducibility compared to LC with UV and ECD, enzyme-linked immunoassay, and capillary electrophoresis methods.