• 제목/요약/키워드: Mass Measurement

검색결과 1,500건 처리시간 0.031초

측정방법 및 기상상태에 따른 PM-10 질량농도 비교 (Comparison of the PM-10 mass concentration in different measurement methods and meteorological conditions)

  • 정창훈;박진희;황승만;정용국
    • 한국입자에어로졸학회지
    • /
    • 제5권2호
    • /
    • pp.53-62
    • /
    • 2009
  • In this study, the continuous monitoring of the concentration of PM-10 atmospheric particulate matter using beta ray attenuation method was compared with gravimetric method from September, 2006 to August, 2007. On the effects of the PM-10 concentration and mass difference by relative humidity and precipitation were considered. The result showed that the measurement error between beta ray method and gravimetric method are within -3~6% in average, which means PM-10 concentration data with beta ray method are relatively comparable. The current study also shows that the high PM-10 concentration events are mainly due to haze, Asian dust, and high relative humidity and the PM-10 mass concentration is closely related with relative humidity and precipitation events. Based on daily mean data, the PM-10 increases as relative humidity increases up to 70~80%, then decreases over 80% due to the precipitation. However, the distinct measurement discrepancy was not shown between beta ray method and gravimetric method based on current results. Consequently, this study shows that the collocated measurement in different instrument is essential in order to quantify the accuracy of PM-10. Furthermore, the more comprehensive and spatially distributed comparison is needed and this is remained for future study.

  • PDF

수화열 계측 및 파이프쿨링 시공 사례 (Field Measurement of Hydration Heat and Field Aaaplication of Pipe Cooling System)

  • 최계식;양주경;최영돈;최고일
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.381-386
    • /
    • 1994
  • Recently, the design and construction of massive concrete structures are increased. But, the temperature rise within a large concrete mass make the construction of massive concrete structures be very difficult. Therefore, in Seohae Grand Bridge Project, the field measurement of hydration heat for the massive concrete footings(11$\times$22$\times$4m) was carried out. It was shown to be possible to construct the massive concrete footing successfully by application of pipe cooling system. And the measurement results showed that standard code for concrete practice was very conservative.

  • PDF

Adaptive Control of Multiplexed Closed Circuit Anesthesia

  • Jee, Gyu-In;Roy, Rob
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.79-81
    • /
    • 1992
  • This paper describes the design of an adaptive closed circuit anesthesia controller based on a multiplexed mass spectrometer system. The controller deals with measurement deterioration caused by measurement delay and rise time through a tong catheter as well as long sampling times due to the multiplexed measurements. Measurement data is extrapolated between sampling periods to increase the estimation convergence rate. A multiple-step-ahead predictive control algorithm is used to calculate intermediatc control inputs between sampling intervals. Simulations are used to validate the designed controller.

  • PDF

암반설계정수 산정을 위한 증거이론의 적용 (Application of Evidence Theory for the Evaluation of Mechanical Rock Mass Properties)

  • 정용복;김태혁;최용근;선우춘
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.521-528
    • /
    • 2005
  • The evaluation process of rock mass properties intrinsically contains some uncertainty due to the inhomogeneity of rock mass and the measurement error. Although various empirical methods for the determination of rock mass properties were suggested, there is no way of integrating various information on rock mass properties except averaging. For these reasons, this research introduces evidence theory which can model epistemic uncertainty and yield reasonable rock mass properties through combining various information such as empirical equations, in-situ test results, and so on. Through the application of evidence theory to the real site investigation and in situ experiment results, an interval of deformation modulus, cohesion and friction angle of rock mass were obtained. The ratios between lower and upper bound of those properties ranges from 1.6 to 3.6. Numerical analyses of circular hole using the properties for TYPE-2 rock mass were carried out. The magnitude or size of plastic region and radial displacement in case of lower bound properties is about 4 times larger than that of upper bound properties.

  • PDF

Accurate Measurement of Arsenic in Laver by Gravimetric Standard Addition Method Combined with High Resolution Inductively Coupled Plasma Mass Spectrometry

  • Lee, Kyoung-Seok;Kim, Hyeon-Ji;Yim, Yong-Hyeon;Kim, Jeongkwon;Hwang, Euijin
    • Mass Spectrometry Letters
    • /
    • 제5권2호
    • /
    • pp.57-61
    • /
    • 2014
  • A gravimetric standard addition method combined with internal standard calibration has been successfully developed for the accurate analysis of total arsenic in a laver candidate reference material. A model equation for the gravimetric standard addition approach using an internal standard was derived to determine arsenic content in samples. Handlings of samples, As standard and internal standard were carried out gravimetrically to avoid larger uncertainty and variability involved in the volumetric preparation. Germanium was selected as the internal standard because of its close mass to the arsenic to minimize mass-dependent bias in mass spectrometer. The ion signal ratios of $^{75}As^+$ to $^{72}Ge^+$ (or $^{73}Ge^+$) were measured in high resolution mode ($R{\geq}10,000$) to separate potential isobaric interferences by high resolution ICP/MS. For method validation, the developed method was applied to the analysis of arsenic content in the NMIJ 7402-a codfish certified reference material (CRM) and the result was $37.07mg{\cdot}kg^{-1}{\pm}0.45mg{\cdot}kg^{-1}$ which is in good agreement with the certified value, $36.7mg{\cdot}kg^{-1}{\pm}1.8mg{\cdot}kg^{-1}$. Finally, the certified value of the total arsenic in the candidate laver CRM was determined to be $47.15mg{\cdot}kg^{-1}{\pm}1.32mg{\cdot}kg^{-1}$ (k = 2.8 for 95% confidence level) which is an excellent result for arsenic measurement with only 2.8 % of relative expanded uncertainty.

Simple and Robust Measurement of Blood Plasma Lysophospholipids Using Liquid Chromatography Mass Spectrometry

  • Ji, Dong Yoon;Lee, Chang-Wan;Park, Se Hee;Lee, Eun Jig;Lee, Do Yup
    • Mass Spectrometry Letters
    • /
    • 제8권4호
    • /
    • pp.109-113
    • /
    • 2017
  • Single analytical procedure including extraction, liquid chromatography, and mass spectrometric analysis was evaluated for the simultaneous measurement of lysophospholipids (LPLs). LPLs, particularly, lysophosphatidic acids (LPA) and sphingosine 1-phosphate (S1P) are lipid messengers ubiquitously found in various biological matrix. The molecular species mediate important physiological roles in association with many diseases (e.g. cancer, inflammation, and neurodegenerative disease), which emphasize the significance of the simple and reliable analytical method for biomarker discovery and molecular mechanistic understanding. Thus, we developed analytical method mainly focusing on, but not limited by those lipid species S1P and LPA using reverse phase liquid chromatography-tandem mass spectrometry (RPLC-ESI-MS-MS). Extraction method was modified based on Folch method with optimally minimal level of ionization additive (ammonium formate 10 mM and formic acid). Reverse-phase liquid-chromatography was applied for chromatographical separation in combination with negative ionization mode electrospray-coupled Orbitrap mass spectrometry. The method validation was performed on human blood plasma in a non-targeted lipid profiling manner with full-scan MS mode and data-dependent MS/MS. The proposed method presented good inter-assay precision for primary targets, S1P and LPA. Subsequent analysis of other types of LPLs identified a broad range of lysophosphatidylcholines (LPCs) and lysophosphatidyl-ethanolamines (LPEs).

Like-Doublet 인젝터의 분무 질량분포 측정을 위한 PLLIF기법의 신뢰성 평가 (Assessment of PLLIF Measurement for Spray Mass Distribution of Like-Doublet Injector)

  • 정기훈;고현석;윤영빈
    • 한국가시화정보학회지
    • /
    • 제1권1호
    • /
    • pp.98-106
    • /
    • 2003
  • A PLLIF (Planar Liquid Laser Induced Fluorescence) technique has been known to be a useful tool for the measurement of the spray patterns for various spray injectors because it can obtain two-dimensional images with high spatial resolutions without any intrusion on the spray field. In case of dense spray, however, the secondary emission as well as the extinction of an incident laser beam or a fluorescence signal can cause errors in quantifying a mass distribution. Unfortunately, a like-doublet injector which has a dense spray zone at the center may not be a good example or the application of the PLLIF technique. Therefore, we took PLLIF data for the like-doublet injector with a 12 bit color CCD camera by varying laser power, and then assessed their accuracy by comparing with the data obtained with a mechanical patternator and a PDPA (Phase Doppler Particle Analyzer). The experimental results showed that the gray level of fluorescence signal increases nonlinearly due to a secondary emission at the dense spray zone but this nonlinearity can be avoided by reducing the incident laser beam power. In addition, the mass flux distribution of the spray could be obtained by using the mass concentration data from PLLIF technique and the velocity profiles of liquid drops, and this distribution showed good agreement with that of mechanical pattemator. Therefore, it is possible that the PLLIF technique can be successfully applied to finding the mass distributions of like-doublet injectors.

  • PDF

Estimation of Mass Discrimination Factor for a Wide Range of m/z by Argon Artificial Isotope Mixtures and NF3 Gas

  • Min, Deullae;Lee, Jin Bok;Lee, Christopher;Lee, Dong Soo;Kim, Jin Seog
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권8호
    • /
    • pp.2403-2409
    • /
    • 2014
  • Absolute isotope ratio is a critical constituent in determination of atomic weight. To measure the absolute isotope ratio using a mass spectrometer, mass discrimination factor, $f_{MD}$, is needed to convert measured isotope ratio to real isotope ratio of gas molecules. If the $f_{MD}$ could be predicted, absolute isotope ratio of a chemical species would be measureable in absence of its enriched isotope pure materials or isotope references. This work employed gravimetrically prepared isotope mixtures of argon (Ar) to obtain $f_{MD}$ at m/z of 40 in the magnetic sector type gas mass spectrometer (gas/MS). Besides, we compare the nitrogen isotope ratio of nitrogen trifluoride ($NF_3$) with that of nitrogen molecule ($N_2$) decomposed from the same $NF_3$ thermally in order to identify the difference of $f_{MD}$ values in extensive m/z region from 28 to 71. Our result shows that $f_{MD}$ at m/z 40 was $-0.044%{\pm}0.017%$ (k = 1) from measurement of Ar artificial isotope mixtures. The $f_{MD}$ difference in the range of m/z from 28 to 71 is observed $-0.12%{\pm}0.14%$ from $NF_3$ and $N_2$. From combination of this work and reported $f_{MD}$ values by another team, IRMM, if $f_{MD}$ of $-0.16%{\pm}0.14%$ is applied to isotope ratio measurement from $N_2$ to $SF_6$, we can determine absolute isotope ratio within relative uncertainty of 0.2 %.

Weak Lensing Analysis of the High-z Massive Galaxy Cluster SPT-CL J0205-5829 Using HST Data

  • Kim, Seojin F.;Jee, Myungkook J.
    • 천문학회보
    • /
    • 제42권1호
    • /
    • pp.50.3-51
    • /
    • 2017
  • Discovered in the South Pole Telescope Sunyaev-Zel'dovich (SPT-SZ) survey, the galaxy cluster SPT-CL J0205-5829 at z = 1.322 might be the most massive known SZ-selected galaxy cluster at z > 1.2. The SZ and X-ray combined mass estimate is $M500=(4.8{\pm}0.8){\times}10^{14}M_{\odot}$. To confirm this extreme mass, we perform weak lensing analysis of SPT-CL J0205-5829 using HST data. Our analysis produces a mass estimate consistent with the previous results obtained from non-lensing methods. In this poster, we describe details of the method including shape measurement, PSF correction, source selection, and mass estimation. We also present a two-dimensional mass map and compare this to the galaxy distribution.

  • PDF

Boron Detection Technique in Silicon Thin Film Using Dynamic Time of Flight Secondary Ion Mass Spectrometry

  • Hossion, M. Abul;Arora, Brij M.
    • Mass Spectrometry Letters
    • /
    • 제12권1호
    • /
    • pp.26-30
    • /
    • 2021
  • The impurity concentration is a crucial parameter for semiconductor thin films. Evaluating the impurity distribution in silicon thin film is another challenge. In this study, we have investigated the doping concentration of boron in silicon thin film using time of flight secondary ion mass spectrometry in dynamic mode of operation. Boron doped silicon film was grown on i) p-type silicon wafer and ii) borosilicate glass using hot wire chemical vapor deposition technique for possible applications in optoelectronic devices. Using well-tuned SIMS measurement recipe, we have detected the boron counts 101~104 along with the silicon matrix element. The secondary ion beam sputtering area, sputtering duration and mass analyser analysing duration were used as key variables for the tuning of the recipe. The quantitative analysis of counts to concentration conversion was done following standard relative sensitivity factor. The concentration of boron in silicon was determined 1017~1021 atoms/㎤. The technique will be useful for evaluating distributions of various dopants (arsenic, phosphorous, bismuth etc.) in silicon thin film efficiently.