• 제목/요약/키워드: Mass Flowrate

검색결과 69건 처리시간 0.029초

복합 관수로에서 인버스 임피던스 확장연구 (Extended inverse impedance method for multiple branches or loops pipeline systems)

  • 고동원;김상현
    • 상하수도학회지
    • /
    • 제37권6호
    • /
    • pp.437-446
    • /
    • 2023
  • We propose a transient evaluation scheme using a pressure measurement in a complicate pipeline systems. Conservation of mass and momentum equations in time domain can be transformed into a pressure head and flowrate relationship between upstream and downstream point in frequency domain. The impedance formulations were derived to address measured pressure at downstream to evaluate of flowrate or pressure head at any point of system. Both branched pipeline element and looped pipeline element can be generally addressed in the platform of the basic reservoir pipeline valve system. The convolution of time domain response function with measured pressure head from a downstream point provides flowrate or pressure head response in any point of the designated pipeline system. The proposed method was validated through comparison between traditional method of characteristics and the proposed method in several hypothetical systems.

4밸브 디젤기관의 흡기포트 형상에 따른 실린더 내 편심 선회유동 특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of the In-cylinder Eccentricity Swirl Flow with Intake Port Shapes in a 4 Valve Diesel Engine)

  • 이지근;김덕진;강신재;노병준
    • 한국자동차공학회논문집
    • /
    • 제6권1호
    • /
    • pp.59-72
    • /
    • 1998
  • This experimental study was carried out to investigate the characteristics of the in-cylinder eccentricity swirl flow generated by a 4 valve cylinder head with a tangential and a helical intake port. the measurements of the in-cylinder velocity field have been made by a two-channel LDA system. The mean flow coefficient(Cf(meam)), swirl ratio(Rs) and mass flowrate with valve eccentricity ratios and an intake port partition between the two intake ports were measured in the steady flow test fig using the ISM(impulse swirl meter). The experimental results indicated that the mass flowrate through the tangential intake port was 19% and 7.7% more than that of the helical intake port in case of with and without intake port partition respectively. There was a tendency to be a single rotation flow in swirl flow fields formed by a 4 valve cylinder head because of the interaction between the two intake ports. As the intake port partition was not set between flow coefficient(Cf(mean)) was 7.35%.

과산화수소/케로신 소형 이원추진제 추력기의 설계 및 성능특성에 관한 연구 (Study for Design and Performance Characteristics of Small Bipropellant Thruster using $H_2O_2$/Kerosene)

  • 김정훈;이재원;전영진;채병찬;전준수;김유;김선진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.41-45
    • /
    • 2009
  • 본 연구에서는 고농도 과산화수소와 케로신을 각각 산화제와 연료로 사용하는 소형 이원추진제 추력기의 설계/제작 및 인젝터 성능특성 파악을 위한 수류시험을 수행하였다. 본 개발모델에서는 점화기, 인젝터, 막냉각 시스템을 통합하여 운용이 가능한 구조의 믹싱헤드를 적용하였으며, 각 부분으로의 공급유량 변경이 가능하도록 하여 최적 설계의 실험적 검증 및 효율성을 극대화하고자 하였다. 마지막으로 수류시험을 통해 인젝터 유량 및 추진제 분사패턴을 확인하였으며, 믹싱헤드의 설계 타당성을 검증하였다.

  • PDF

R141b 포접화합물을 이용한 축냉시스템의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Cool Storage System using R141b Clathrate)

  • 정인성;김양규;이준식;노승탁
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.354-364
    • /
    • 1994
  • Experiments have carried out to investigate the effects of parameters, such as mass ratio of R141b-to-water, stirrer speed, brine inlet temperature, brine flowrate, and additives, on the performance of the cool storage system using R141b clathrate. The cool storage system in this experiment was composed of storage tank, refrigerator, and heater. The results show that the mass ratio of R141b-to-water, 1 : 3~1 : 3.5 gives the best performance and the stirring speed has optimum point as 600rpm. At this speed impeller Reynolds number is $1.01{\times}10^5$. The lower the inlet brine temperature and the highter the brine flowrate, the better performance. The addition of metal powder turned out to reduce the degree of supercooling. The supercooling reduction was proportional to the amount of the metal power. However when metal powder was added more than 0.1 wt%, there was no additional supercooling reduction. The surfactants shortened the time consumed for cool storage to the half of no surfactant added case.

  • PDF

수평원관상의 LiBr-수용액에 수증기가 흡수될때의 열 및 물질전달 (Coupled Heat and Mass Transfer during the Absorption of Water Vapor into LiBr-H2O Liquid Solution Flowing down the Outside of the Horizontal Cylinder)

  • 이관수;서석청;김영인;박동규
    • 대한설비공학회지:설비저널
    • /
    • 제17권2호
    • /
    • pp.140-149
    • /
    • 1988
  • The problem of heat and mass transfer accompanying the absorption of water vapor into LiBr-$H_2O$ liquid solution flowing over the outside of the horizontal cylinder was theoretically studied to understand the absorption process occuring in the absorber of the absorption heat pump. Numerical results are presented for various quantities of interest relating to temperature, concentration, heat flux and mass flux. Also, the effects of mass flowrate, initial average velocity, and the radius of the cylinder were investigated.

  • PDF

열량형 질량유량계에 대한 압력과 비열 영향 (The Effects of Pressure and Specific Heat on the Performance of Thermal Mass Flowmeter)

  • 최용문;박경암;최해만;이기성
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.109-113
    • /
    • 1999
  • Thermal mass flow meter (TMF) is used measuring the small mass flow rate of gases. Generally, flow rate measuring accuracy of TMF is $\pm2{\%}$ of full scale. TMF is manufactured for specified working pressure and specified working gas by customer. If it were applied for different working pressure and gases, flow rate measurement accuracy decreased dramatically. In this study, a TMF tested with three different gases and pressure range of 0.2 MPa to 1.0 MPa. Effect of specific heat cause to increase flow measurement error as much as ratio of specific heat compare with reference gas. Pressure change cause to increase flowrate measurement deviation about $-0.2{\%}$ as the working pressure decreased 0.1 MPa.

  • PDF

소형 코리올리 질량 유량계의 개발 (Development of Small Size Coriolis Mass Flowmeter)

  • 임기원;지정근
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.497-504
    • /
    • 2006
  • A Coriolis mass flowmeter(CMF), which has U-Shaped unique measurins tube was developed fo. direct mass flow measurement. In order to convert the time difference between two measuring tubes motion into mass flowrate and flow quantity, a signal processing circuit, as a part of CMF, was also developed. The CMF was designed as the 15 mm nominal diameter of pipe connection and the 8 mm stainless steel(sus 316) pipe was used for measuring tube. To maximize the flow signal(time difference) from the measuring tubes, the natural frequency of measuring tube was adjusted as 220 Hz, which is same as the frequency of exciter. The maximum displacement at the end of the measuring tube was measured as 0.05 mm and the maximum time difference between two measuring tubes was observed as $20{\mu}s$, which was proper for discrimination and measuring range of CMF. The developed CMF was tested against the gravimetric flowmeter calibrator in the range of 3 kg/min and 30 kg/min. The results showed that the CMF has good linearity and repeatability in the tested flow range. Large size of CMF base on the current study experience will be developed.

Development of the Fresh Water Generator

  • Park, Jun-Seop
    • 에너지공학
    • /
    • 제8권4호
    • /
    • pp.546-552
    • /
    • 1999
  • In order to obtain the highly effective thermal energy from jacket cooling water of propulsion diesel engines. a development of the Fresh Water Generator (FWG) with a capacity of 30 ton/day was implemented. Newly developed experimental devices and data acquisition system were used to evaluate the performance of the FWG. In this study experiments were performed for various driving pressures by varying the mass flowrate of cooling seawater with or without a heat source instead of jacket cooling water.

  • PDF

낙동강수계에서 섬유염색 및 가공 업체에 대한 공정별 원단위산정 및 분석 (Unit Mass Estimation and Analysis from Fiber Dyeing and Finishing Facility Nearby Nakdong River Basin)

  • 구정은;나동훈;이승환
    • 대한환경공학회지
    • /
    • 제31권9호
    • /
    • pp.765-774
    • /
    • 2009
  • 섬유염색 및 가공산업은 용수요구량이 매우 높은 편이며 다양한 난분해성 염료의 사용으로 인해 폐수발생량의 기여도가 높은 전형적인 오염 유발 산업이다. 본 연구는 낙동강 수계에서 산업폐수 발생업체 중 섬유염색 및 가공 산업시설을 중심으로 SS, $BOD_5,\;COD_{Mn},\;COD_{Cr}$, TN 그리고 TP와 같은 수질 항목에 대해서 발생원 단위 오염물질 배출 특성을 파악하고 발생원단위 부하량을 산출하기 위해 수행되었다. 각 산업을 대표하는 오염원 발생원단위의 산정을 위해 낙동강 수계에 산재한 섬유염색 및 가공업체 중 세 개 업체를 선정하였다. BOD 기준 유입수와 유출수에서의 원단위 값은 90%이상 감소하였지만 원수에서의 높은 유기물 부하량으로 인해 원단위값 자체는 섬유제조시설에서 얻어진 값과 유사하였다. 유수의 생분해도는 유출수에 비해 세배 가량 높게 나타났다. 건평, 제품생산량 및 원료사용량을 기준으로 한 주요 수질 항목 (SS, $BOD_5$, COD, TN and TP)에서 단위공정(본 연구에서 산정한 값)의 오염원 발생원단위 결과값이 통합공정(국립환 경과학원에서 산정한 값)의 오염원 발생원단위 결과 값과 유사하였지만 다른 인자를 기준으로 한 경우에는 커다란 차이를 보여주었다. 섬유염색 및 가공업체에서 도출된 오염원 발생원단위 인자는 낙동강 수질 오염총량제 도입과 함께 수질오염 부하량 처리비용을 산정 할 때 유용한 자료로 활용될 수 있으리라 기대된다. 이러한 오염원 발생부하량 도출과 함께 낙동강 수계에서의 효과적인 수질오염제어와 관리를 위해서는 각 산업별 폐수처리시설의 유출수로부터 다양한 형태의 수질오염항목을 특성화시킬 필요가 있다.

코리올리스 질량유량계의 유량측정에 영향을 미치는 인자에 관한 실험적 연구 (An Experimental Study on the Influential Factors of Flow Measurement with Coriolis Mass Flowmeter)

  • 임기원;이완규
    • 대한기계학회논문집B
    • /
    • 제27권12호
    • /
    • pp.1699-1707
    • /
    • 2003
  • Coriolis mass flowmeter(CMF), which can measure the mass flow directly, is getting rapid attention for the industrial and custody transfer purpose. In order to study the characteristics and the applicability of CMF, it is tested with the national flow standard system. Two types of sensing tube, U-type and straight type, are employed in the test. Water, spindle oil and viscosity Standard Reference Material whose viscosities are 1, 20 and, 67 $\textrm{mm}^2$/s, respectively, are studied. It is shown that the linearity of CMF is getting deteriorated as the fluid viscosity increases, which is due to the zero drift and the relaxation time of the fluid. To test its applicability in the case of high pressured gas, it is calibrated using compressed air, It shows 1∼l.6 % deviations compared to the calibration results using water. It concludes that the fluid velocity in CMF should be lower than the sonic velocity. In addition, the effects of the vibration from the pipeline and pump on CMF as well as the long term stability are studied.