• Title/Summary/Keyword: Marginal Adaptation

Search Result 106, Processing Time 0.027 seconds

AN EXPERIMENTAL STUDY OF THE EFFECTS OF DENTIN ADHESIVES ON MARGINAL ADAPTATION OF LIGHT CURED COMPOSITE RESIN (상아질 접착제의 사용에 의한 광중합성 복합레진의 변연접합도에 관한 실험적 연구)

  • Park, Seong-Ho;Lee, Chung-Suck;Park, Dong-Soo;Lee, Chan-Youg;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.1
    • /
    • pp.141-152
    • /
    • 1990
  • The purpose of this study was to evaluate the effects of dentin adhesives(Gluma$^{(R)}$ and Scotchbond 2$^{(R)}$) on the marginal adaptation of light cured composite resin (Heliosit$^{(R)}$) by using SEM. The recently extracted 30 teeth were used and round cavities were prepared on the occlusal surfaces of the teeth with predesigned depth and diameter. The teeth were divided into three groups. Group 1 : Gluma$^{(R)}$ + Heliosit$^{(R)}$ Group 2 : Scotchbond 2$^{(R)}$ + Heliosit$^{(R)}$ Group 3 : Enamelbond$^{(R)}$ + Heliosit$^{(R)}$ Filling with Heliosit, the teeth were stored in saline solution for 24 hours. After the thermocycling procedure, the teeth were cut vertically into the restorations. The SEM observation was carried out to evaluate the marginal adaptation of the composite resin. The following results were obtained. The following results were obtained. 1. The groups using Gluma$^{(R)}$ and Scotchbond 2$^{(R)}$ showed better than the control group on marginal adaptation to the dentin. 2. The group using Gluma$^{(R)}$ was superior to the group using Scotchbond 2$^{(R)}$, but the difference was not significant. 3. In all groups, the marginal gaps were wider on the pulpal walls than on the lateral walls of restorations.

  • PDF

Study on methodology for the assessment of internal and marginal adaptation on fixed dental prosthesis (고정성 보철물의 내면 및 변연적합도를 평가하는 방법에 대한 고찰)

  • Pyo, Se-Wook;Lee, Jun-Jae;Han, Jung-Suk;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.158-168
    • /
    • 2016
  • This article is to review various methods used to investigate internal and marginal adaptation of fixed dental prostheses, and to summarize a merit, worth, and limitation of each method, using some results of previous studies. The methods of measuring internal and marginal gap are divided into two categories in this study; in vivo and in vitro. In vivo methods are clinical evaluations, including exploration, radiography, and impression technique. In vitro methods are laboratory evaluations such as direct view, cross-sectioning, and silicone replica technique using microscope. Measuring by micro computed tomography (CT) or profilometer is also in vitro methods. In recent years, the development of scanning systems is able to analyze 3-dimensional internal and marginal space in detail. As measuring and analyzing technology become more advanced, the ability to thoroughly examine crown adaptation is becoming both simpler and more efficient.

Effect of anatomic, semi-anatomic and non-anatomic occlusal surface tooth preparations on the adaptation of zirconia copings

  • Habib, Syed Rashid;Asiri, Waleed;Hefne, Mohammed Jameel
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.444-450
    • /
    • 2014
  • PURPOSE. To compare the accuracy of marginal and internal adaptation of zirconia (Zr) copings fabricated on anatomic (A), semi-anatomic (SA) and non-anatomic (NA) occlusal surface preparations. MATERIALS AND METHODS. 45 extracted bicuspid teeth were prepared for receiving zirconia crowns, with different occlusal preparation designs A=15, SA=15 & NA=15. The Zr copings were fabricated by using CAD4DENT, CAD/CAM. The copings were adjusted, cemented and were cross sectioned centrally from buccal cusp tip to lingual cusp tip into mesial and distal halves. The copings were examined under electron microscope at ${\times}200$ magnification and the measurements were recorded at 9 predetermined areas in micrometers. RESULTS. Overall mean gap values for the three groups was found to be $155.93{\pm}33.98{\mu}m$ with Anatomical Occlusal preparation design having the least gap value of $139.23{\pm}30.85{\mu}m$ showing the best adaptation among the groups. Post Hoc Tukey's test showed a statistically significant difference (P=.007) between the means of gap for A & NA preparation designs. Measurements recorded at 9 predetermined points showed variations for the three groups. CONCLUSION. Anatomical occlusal preparation designs resulted in better marginal and internal adaptation of Zr copings. There is a considerable variation between the measured marginal and internal gap values for the Zr copings fabricated by the (CAD4DENT-CAD/CAM). This variation may be associated with the lack of standardization of the preparation of teeth, computerized designing of the coping for each tooth, cement used, uniform pressure application during the cementation of the copings, sectioning of the copings and the microscopic measurements.

Comparative study in marginal adaptation of zirconia cores fabricated with 3 different CAD/CAM systems (3종의 CAD/CAM 시스템에서 지르코니아 코어의 변연 적합도에 관한 비교 연구)

  • Kwon, Yong-Joong;Lee, Young-Soo;Park, Won-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.12-21
    • /
    • 2008
  • Statement of problem: There have been many studies about marginal adaptation of Zirconia core fabricated with various CAD/CAM systems. But, the comparative study has not been conducted much. Purpose: This study was to compare marginal adaptations of zirconia cores fabricated with 3 different CAD/CAM systems. Material and methods: The in vitro marginal adaptations of zirconia cores fabricated with 3 different CAD/CAM systems($Adens^{(R)}$ system, $Lava^{(R)}$ system, and $Cerasys^{(R)}$ system) were evaluated and compared. In this study 30 zirconia cores were fabricated(10 zirconia cores per each system). The measurements of the marginal adaptatioin were carried out using microscope $L-150A^{(R)}$(Nikon, Japan). Measurements were recorded at 50 points. The measurements were analyzed using Kruskal-Wallis test and Wilcoxon rank sum test. Results: Within the limits of this study, the results were as follows. 1. Mean marginal gap values obtained were $284.5{\pm}152.9{\mu}m$ in Adens system, $99.0{\pm}73.0{\mu}m$ in Lava system, and $153.5{\pm}85.7{\mu}m$ in Cerasys system. 2. Zirconia core made by Lava system showed the smallest marginal gap(P<0.05). Conclusion: In the limitation of this study, we concluded that $Lava^{(R)}$ System was superior than other systems($Adens^{(R)}$ system and $Cerasys^{(R)}$ system) in the marginal adaptation.

Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations

  • Hasanzade, Mahya;Koulivand, Soudabeh;Moslemian, Naeime;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.173-180
    • /
    • 2020
  • PURPOSE. This study compared digital (reference point matching) and replica methods for measuring marginal and internal fit of full coverage restorations. MATERIALS AND METHODS. A maxillary left first molar typodent was fixed on to an aluminum base and prepared to receive all-ceramic full coverage restoration. The model was scanned with an intraoral scanner (CEREC Omnicam, Sirona, York, PA, USA). Twelve crowns were fabricated from lithium disilicate blocks (IPS emax CAD, Ivoclar Vivadent) and then crystalized. Marginal and internal fit of each restoration was measured by two examiners using replica and a new digital three-dimensional technique. Reliability between the two methods and two examiners was assessed by correlation and Cronbach's Alpha coefficient (P<.05). A Bland-Altman assessment for agreement was used to compare the two methods. RESULTS. Bland-Altman assessment showed that the mean of difference for marginal, absolute marginal, and axial gap was respectively -1.04 ㎛, -41.9 ㎛, and -29.53 ㎛ with limit of agreement (LOA) between -37.26 to 35.18 ㎛ for marginal, -105.85 to 22.05 ㎛ for absolute marginal and -80.52 to 22.02 ㎛ for axial gap. Positive correlation for repeatability (P<.05) in determining marginal and internal gaps by the two examiners in both techniques was revealed. Reliability of both techniques in all sites of measurements was at least good (0.8 ≤ α < 0.9). CONCLUSION. Both measuring techniques appeared highly reliable for evaluating fit of fixed dental restorations, while reference point matching provided higher values in axial and absolute marginal gap assessment.

MICROLEAKAGE AND MARGINAL ADAPTATION OF POSTERIOR COMPOSITE RESIN RESTORATIONS ACCORDING TO RESTORATIVE TECHNIQUE (수복에 따른 구치부 복합레진 수복물의 변연부 미세누출 및 적합도)

  • Yang, In-Seo;Shin, Dong-Hoo
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.334-346
    • /
    • 1997
  • Incidence of using esthetic composite resin in the posterior area is increasing but there were lots of inconsistent reports about their microleakage and marginal adaptation. The purpose of this study was to evaluate the differences of microleakage and marginal adaptation according to restorative techniques. 30 cavities with enamel gingival margin were prepared and restored with 3 types of composite resin [Z-100($Scotchbond^{TM}$ MP), AELITEFIL ($Onestep^{TM}$), Her culite XRV(Fuji BOND LC)] in direct technique and another 30 cavities were restored with preformed CR inlays and 3 different modern resin and resin-modified GI cements (Superbond C&B, Choice, Fuji Duet). Samples were chemically stressed in 75% ethanol for 24 hours and were thermocycled (5-$55^{\circ}C$(500 times. The degree of microleakage through proximal and gingival margins was examined by 1 % MB dye and the degree of marginal adaptation by examining the margins via SEM. The following results were obtained ; 1. In direct groups, Herculite XRV [Fuji BOND LC, 35.13 (15.50) %] group showed statistically different, less microleakage than Z-100 [$Scotchbond^{TM}$ MP, 72.91 (16.91 %] group and AELITEFIL [One-step, 93.73 (13.66) %] group (p<0.05). 2. In indirect groups, the degree of microleakage in Mean(S.D.) were: Super bond C & B [39.00 (24.35) %], Choice [57.19 (33.80) %], Fuji Duet [58.22 (40.36) %]. But there was no significant difference. 3. There was no significant difference between resin cement and resin-modified GI cement. 4. There were gaps at the interface with the tooth structure, but no gap was seen at the interface with restoration in all specimens. 5. In direct groups, Herculite XRV(Fuji BOND LC) group made little gap compared with other groups, but 40-$50{\mu}m$ thickness of bonding agent, Fuji BOND LC, looked like a cement used in indirect technique. 6. All indirect groups showed a variety of cement thickness, from less than $20{\mu}m$ to over $100{\mu}m$ and that dimension of buccal/lingual margin was less than that of gingival margin.

  • PDF

Push-out bond strength and marginal adaptation of apical plugs with bioactive endodontic cements in simulated immature teeth

  • Maria Aparecida Barbosa de Sa;Eduardo Nunes ;Alberto Nogueira da Gama Antunes ;Manoel Brito Junior ;Martinho Campolina Rebello Horta ;Rodrigo Rodrigues Amaral;Stephen Cohen ;Frank Ferreira Silveira
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.53.1-53.11
    • /
    • 2021
  • Objectives: This study evaluates the bond strength and marginal adaptation of mineral trioxide aggregate (MTA) Repair HP and Biodentine used as apical plugs; MTA was used as reference material for comparison. Materials and Methods: A total of 30 single-rooted teeth with standardized, artificially created open apices were randomly divided into 3 groups (n = 10 per group), according to the material used to form 6-mm-thick apical plugs: group 1 (MTA Repair HP); group 2 (Biodentine); and group 3 (white MTA). Subsequently, the specimens were transversely sectioned to obtain 2 (cervical and apical) 2.5-mm-thick slices per root. Epoxy resin replicas were observed under a scanning electron microscope to measure the gap size at the material/dentin interface (the largest and smaller gaps were recorded for each replica). The bond strength of the investigated materials to dentin was determined using the push-out test. The variable bond strengths and gap sizes were evaluated independently at the apical and cervical root dentin slices. Data were analyzed using descriptive and analytic statistics. Results: The comparison between the groups regarding the variables' bond strengths and gap sizes showed no statistical difference (p > 0.05) except for a single difference in the smallest gap at the cervical root dentin slice, which was higher in group 3 than in group 1 (p < 0.05). Conclusions: The bond strength and marginal adaptation to root canal walls of MTA HP and Biodentine cement were comparable to white MTA.

Evaluation and comparison of the marginal adaptation of two different substructure materials

  • Karaman, Tahir;Ulku, Sabiha Zelal;Zengingul, Ali Ihsan;Guven, Sedat;Eratilla, Veysel;Sumer, Ebru
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.257-263
    • /
    • 2015
  • PURPOSE. In this study, we aimed to evaluate the amount of marginal gap with two different substructure materials using identical margin preparations. MATERIALS AND METHODS. Twenty stainless steel models with a chamfer were prepared with a CNC device. Marginal gap measurements of the galvano copings on these stainless steel models and Co-Cr copings obtained by a laser-sintering method were made with a stereomicroscope device before and after the cementation process and surface properties were evaluated by scanning electron microscopy (SEM). A dependent t-test was used to compare the mean of the two groups for normally distributed data, and two-way variance analysis was used for more than two data sets. Pearson's correlation analysis was also performed to assess relationships between variables. RESULTS. According to the results obtained, the marginal gap in the galvano copings before cementation was measured as, on average, $24.47{\pm}5.82{\mu}m$ before and $35.11{\pm}6.52{\mu}m$ after cementation; in the laser-sintered Co-Cr structure, it was, on average, $60.45{\pm}8.87{\mu}m$ before and $69.33{\pm}9.03{\mu}m$ after cementation. A highly significant difference (P<.001) was found in marginal gap measurements of galvano copings and a significant difference (P<.05) was found in marginal gap measurements of the laser-sintered Co-Cr copings. According to the SEM examination, surface properties of laser sintered Co-Cr copings showed rougher structure than galvano copings. The galvano copings showed a very smooth surface. CONCLUSION. Marginal gaps values of both groups before and after cementation were within the clinically acceptable level. The smallest marginal gaps occurred with the use of galvano copings.

Evaluation of marginal adaptation in three-unit frameworks fabricated with conventional and powder-free digital impression techniques

  • Kocaagaoglu, Hasan;Albayrak, Haydar;Sahin, Sezgi Cinel;Gurbulak, Aysegul Guleryuz
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.5
    • /
    • pp.262-270
    • /
    • 2019
  • PURPOSE. The purpose of this in vitro study was to evaluate the marginal misfits of three-unit frameworks fabricated with conventional and digital impressions techniques. MATERIALS AND METHODS. Thirty brass canine and second premolar abutment preparations were fabricated by using a computer numerical control machine and were randomly divided into 3 groups (n=10) as follows: conventional impression group (Group Ci), Cerec Omnicam (Group Cdi), and 3shape TRIOS-3 (Group Tdi) digital impression groups. The laser-sintered metal frameworks were designed and fabricated with conventional and digital impressions. The marginal adaptation was assessed with a stereomicroscope at ${\times}30$ magnification. The data were analyzed with 1-way analysis of variances (ANOVAs) and the independent simple t tests. RESULTS. A statistically significant difference was found between the frameworks fabricated by conventional methods and those fabricated by digital impression methods. Multiple comparison results revealed that the frameworks in Group Ci (average, $98.8{\pm}16.43{\mu}m$; canine, $93.59{\pm}16.82{\mu}m$; premolar, $104.10{\pm}15.02{\mu}m$) had larger marginal misfit values than those in Group Cdi (average, $63.78{\pm}14.05{\mu}m$; canine, $62.73{\pm}13.71{\mu}m$; premolar, $64.84{\pm}15.06{\mu}m$) and Group Tdi (average, $65.14{\pm}18.05{\mu}m$; canine, $70.64{\pm}19.02{\mu}m$; premolar, $59.64{\pm}16.10{\mu}m$) (P=.000 for average; P=.001 for canine; P<.001 for premolar). No statistical difference was found between the marginal misfits of canine and premolar abutment teeth within the same groups (P>.05). CONCLUSION. The three-unit frameworks fabricated with digital impression techniques showed better marginal fit compared to conventional impression techniques. All marginal misfit values were clinically acceptable.

Marginal Adaptation of Zirconium Dioxide Core according to the Abutment Teeth (지대치 형태에 따른 지르코니아 코어의 변연 적합도)

  • Kim, Ki-Baek;Kim, Seok-Hwan;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.15 no.1
    • /
    • pp.54-59
    • /
    • 2015
  • The present study investigated the influences of various abutment teeth shapes (maxillary right canine, pre-molar, molar) on the marginal adaptation of computer aided design/computer aided manufacturing-fabricated zirconia core. In vitro adaptation of zirconia cores manufactured by three different abutments were evaluated. Thirty zirconia cores were made per each models and the adaptation was evaluated through a silicone replica technique. The measurement of the adaptation was carried out using digital microscope. The mean and standard deviation of each reference point were analyzed using the one-way (ANOVA) and Tukey's honestly significant difference tests (${\alpha}=0.05$). The overall marginal fits of the zirconia cores were as follows: canine: $47.59{\mu}m$, pre-molar: $43.74{\mu}m$, molar: $40.36{\mu}m$. They were no statistically significant differences between groups for adaptation (p>0.05). This confirmed that the type of abutment teeth used does not determine the precision of fit of zirconia core.