• 제목/요약/키워드: Manual measurements

검색결과 225건 처리시간 0.031초

퇴행성 슬관절염의 화침 치료에 대한 체계적 문헌 고찰 및 메타분석: 최근 5년간의 호침 치료 비교 연구를 중심으로 (A Systematic Review and Meta-Analysis of Fire Needling Treatment for Knee Osteoarthritis: Focused on Comparative Studies with Manual Acupuncture Treatment during Recent Five Years)

  • 고홍제;유재희;신정철
    • Korean Journal of Acupuncture
    • /
    • 제36권2호
    • /
    • pp.104-114
    • /
    • 2019
  • Objectives : The purpose of this study is to review the effectiveness of fire needling treatment for knee osteoarthritis in comparison with manual acupuncture treatment. Methods : Through four foreign online databases (PubMed, Cochrane library, EMBASE, and CNKI) and five domestic online databases (NDSL, RISS, KISS, OASIS, and KTKP), we searched for clinical studies that performed fire needling treatment for knee osteoarthritis until May 10, 2019. Only randomized controlled trials were selected and we assessed the risk of bias according to the Cochrane RoB criteria. This review examined the selected studies into first author, publication year, sample size, outcome measurements, results, acupoints, treatment time & period and so on. Results : A total of 7 RCTs were selected in this review and all were conducted in China. Treatment period of more than 4 weeks and treatment visits of 10 to 20 times were the most common. EX-LE4 and ST35 (=EX-LE5) acupoints were most frequently selected in treatment. Among the evaluation indexes, a total efficacy rate was used the most. Most of fire needling groups showed more significant results compared with the manual acupuncture groups statistically. Conclusions : All studies showed that fire needling treatments for knee osteoarthritis were more effective than manual acupuncture treatments statistically. Therefore, the results of this study could be utilized as a preliminary data for another clinical research on fire needling treatment for knee osteoarthritis. However, further well-designed randomized controlled trials will be needed to develop sufficient evidence about the effectiveness and safety of fire needling treatment for knee osteoarthritis in the future.

Investigation of the Influence of Induced Mood on Rehabilitation Engagement: a Study Focusing on Muscle Activity

  • Kim, Jung-Yeon;Jung, Bong-Keun
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권3호
    • /
    • pp.161-169
    • /
    • 2022
  • Engagement is an important factor in the field of rehabilitation as it is a known factor that have a positive influence on functional gaining in people who receive rehabilitation therapy. Although a number of measurements for engagement have been recently developed, investigation of possible factors that may have influence on engagement is not well established. Currently available evidence suggests that engagement is affected by mood and it is hypothesized that a personal factor may contribute to engagement. Therefore, this study aims to test the hypothetical relationship between mood and engagement while performing a manual dexterity task through an experiment in healthy participants prior to investigation on people with medical condition who requires rehabilitation therapy. After inducing target mood (positive or negative mood) for study participants by asking them to recall autobiographical memories, change in muscle activity, which was operationalized as an indicator of engagement, was investigated. Electromyogram (EMG) was recorded from four muscle areas in non-dominant hand side to quantify muscle activity. The results show that the target moods were appropriately induced with the method. Although there were subtle differences in the level of engagement between different moods, certain variables derived from muscle activity were significantly different; mean amplitude for wrist extensor EMG showed significant difference between different moods (Z = -2.023, p < .05) indicating that muscle activities in the wrist extensor are greater for positive mood than negative mood region during manual dexterity task. Meanwhile, performance outcomes of Minnesota Manual Dexterity Test (MMDT), such as mean completion time and number of errors, between moods showed no significant difference in two different moods, resulting in MMDT administration may not be useful task in distinguishing the level of rehabilitation engagement.

단위 동작 모형에 따른 로봇 작업시간 측정법의 개발 (Development of robot work measurement by the unit motion model)

  • 권규식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.367-370
    • /
    • 1996
  • This study deals with the motion modeling by the unit motion of robots and the work measurement through classification of robot motions and standardization. The proposed approach is to scrutinize the Predetermined Time Standards(PTS) methods for measurement of manual tasks performed by people and the basic motions for accomplishing that tasks. And then, it constructs the unit motion models as subsets composed with the basic motions. It apply together with movements distance as a time variable, too. These results are used for the work measurements of robots by the unit motion models.

  • PDF

Health-monitoring을 위한 휠체어 기반 체중측정 장치 개발 (Development of the weighing scale device based on wheelchair for health-monitoring)

  • 강동원;김경명;장경배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1976_1977
    • /
    • 2009
  • The number and percentage of people in need of a wheelchair are increasing every year, both manual and power wheelchair users express an interest in monitoring their weight. However, frequent measurements are not possible when relying on hospital scales and models designed for home use are expensive. So the goals of this study became to create a product that's relatively inexpensive, portable, and precise, which means varying little between measurements. Secondary goals were ease of use, compatibility with different kinds of wheelchairs, and accuracy, which means achieving proximity to an actual value and isn't as important when trying to monitor increases or decreases in weight.

  • PDF

응급상황시 이송중인 구급차에서 신뢰할 수 있는 혈압계 검증 (Verification of Reliable Blood Pressure Monitor in a Moving Ambulance during an Emergency)

  • 전재인
    • 문화기술의 융합
    • /
    • 제8권3호
    • /
    • pp.91-97
    • /
    • 2022
  • 이 연구의 목적은 이동하는 구급차에서 혈압계의 신뢰성을 검증하기 위해 다양한 도로 상황에서 수동 및 자동혈압계를 이용하여 혈압 및 시간 측정값을 분석하는 것이다. 첫째, 비포장 도로에서 수동 혈압계 촉진 결과 수축기 혈압 편차가 5mmHg로 나타났다. 그러나 자동 혈압계는 2개의 측정 실패, 1개의 판독 실패를 보여주었으며 측정된 수축기 혈압 편차는 35mmHg였다. 측정 시간은 자동 혈압계보다 평균 102초 빨랐다. 둘째, 과속방지턱을 넘을 때 수동 혈압계의 촉진은 130mmHg로 일정하게 유지되었다. 그러나 자동 혈압계의 수축기 혈압 편차는 52mmHg였다. 측정 시간은 자동 혈압계보다 평균 61초 빨랐다. 마지막으로 급커브 도로에서 수동 혈압계 촉진 결과 수축기 혈압 편차는 5mmHg로 나타났다. 자동 혈압계는 판독 실패가 1회 있었고 측정된 수축기 혈압 편차는 21mmHg였다. 측정 시간은 수동 혈압계가 자동 혈압계보다 101초 빠른 것으로 나타났다. 그 결과 응급상황시 이송중인 구급차에서 수동 혈압계는 혈압 측정이 일정하고 측정 시간이 짧아 높은 신뢰도를 보였다.

A Three-Dimensional Deep Convolutional Neural Network for Automatic Segmentation and Diameter Measurement of Type B Aortic Dissection

  • Yitong Yu;Yang Gao;Jianyong Wei;Fangzhou Liao;Qianjiang Xiao;Jie Zhang;Weihua Yin;Bin Lu
    • Korean Journal of Radiology
    • /
    • 제22권2호
    • /
    • pp.168-178
    • /
    • 2021
  • Objective: To provide an automatic method for segmentation and diameter measurement of type B aortic dissection (TBAD). Materials and Methods: Aortic computed tomography angiographic images from 139 patients with TBAD were consecutively collected. We implemented a deep learning method based on a three-dimensional (3D) deep convolutional neural (CNN) network, which realizes automatic segmentation and measurement of the entire aorta (EA), true lumen (TL), and false lumen (FL). The accuracy, stability, and measurement time were compared between deep learning and manual methods. The intra- and inter-observer reproducibility of the manual method was also evaluated. Results: The mean dice coefficient scores were 0.958, 0.961, and 0.932 for EA, TL, and FL, respectively. There was a linear relationship between the reference standard and measurement by the manual and deep learning method (r = 0.964 and 0.991, respectively). The average measurement error of the deep learning method was less than that of the manual method (EA, 1.64% vs. 4.13%; TL, 2.46% vs. 11.67%; FL, 2.50% vs. 8.02%). Bland-Altman plots revealed that the deviations of the diameters between the deep learning method and the reference standard were -0.042 mm (-3.412 to 3.330 mm), -0.376 mm (-3.328 to 2.577 mm), and 0.026 mm (-3.040 to 3.092 mm) for EA, TL, and FL, respectively. For the manual method, the corresponding deviations were -0.166 mm (-1.419 to 1.086 mm), -0.050 mm (-0.970 to 1.070 mm), and -0.085 mm (-1.010 to 0.084 mm). Intra- and inter-observer differences were found in measurements with the manual method, but not with the deep learning method. The measurement time with the deep learning method was markedly shorter than with the manual method (21.7 ± 1.1 vs. 82.5 ± 16.1 minutes, p < 0.001). Conclusion: The performance of efficient segmentation and diameter measurement of TBADs based on the 3D deep CNN was both accurate and stable. This method is promising for evaluating aortic morphology automatically and alleviating the workload of radiologists in the near future.

3차원 인체 측정기를 이용한 체표변화 분석 (Upper Body Surface Change Analysis using 3-D Body Scanner)

  • 이정란
    • 한국의류학회지
    • /
    • 제29권12호
    • /
    • pp.1595-1607
    • /
    • 2005
  • 3차원 스캐너를 통한 인체 측정치는 다양한 분야에서 사용되고 있다. 본 연구는 이러한 3차원 측정치의 정확성과 신뢰도를 조사하기 위한 것이다. 이를 위해 TECMATH사의 VITUS 전신 스캐너로 인체를 측정, ScanWorX Body Measure 소프트웨어를 이용하여 항목을 측정 한 값과 직접 인체측정 에 의해 얻어진 값을 비교하였다. 피험자는 평균 체형의 미국 여대생 25명이며 기준 자세와 일상생활에 많이 쓰이는 $135^{\circ}$ 양팔들기, 어깨 구부리기, 어깨 들어올리기의 3가지 동적 자세를 실험 동작으로 하여 체표의 길이 및 둘레의 변화를 측정하였다. 기준 자세와 135"양팔 들기에 대한 측정치 비교에서 두 가지 측정법에 의한 항목들의 차이는 $-2\~20mm$였으나 두 동작 모두에서 목둘레만이 유의한 차이가 있는 것으로 나타났다. 또한 길이항목보다 둘레항목에서 좀 더 큰 차이를 보였다. 실험 동작에 의해 상반신 18개의 측정항목들은 유의한 체표변화를 나타내었으며 특히 어깨길이, 겨드랑앞벽사이길이, 겨드랑뒤벽사이길이 그리고 견봉사이길이에서 뚜렷한 변화가 나타났다. 그러나 두 측정 법에 따른 체표변화 차이는 없었다. 어깨 구부리기와 어깨 들어올리기 동작시에는 스캔 측정을 3회 반복함으로써 3차원 측정치의 신뢰도를 조사하였는데 모든 항목에서 3회 반복된 측정치가 통계적으로 동일한 것으로 나타났다. 또한 ScanWorX소프트웨어의 가상적 도구인 Body Measure와 자동 프로그램인 ScanWorX Tailor의 측정치를 비교한 결과 자동 측정치가 더 큰 값을 보였고 사용한 프로그램에 따른 유의한 차이를 나타내는 항목들이 나타났다. 이상의 결과로 3차원 인체 측정기를 사용함으로써 짧은 시간에 동작을 촬영하고 이에 대한 측정치를 얻을 수 있어 편리함과 신뢰도에 있어서 장점을 가짐을 확인할 수 있었다. 그러나 좀 더 다양한 분석과 정확한 결과를 얻기 위해서는 의복 분야에 유용한 자동 프로그램의 개발과 3차원 인체 측정기간의 호환성의 문제들이 요구된다고 할 수 있다.

돕슨 분광광도계(No.124)의 오존 자동관측시스템화 (Automation of Dobson Spectrophotometer(No.124) for Ozone Measurements)

  • 김준;박상서;문경정;구자호;이윤곤;;조희구
    • 대기
    • /
    • 제17권4호
    • /
    • pp.339-348
    • /
    • 2007
  • Global Environment Laboratory at Yonsei University in Seoul ($37.57^{\circ}N$, $126.95^{\circ}E$) has carried out the ozone layer monitoring program in the framework of the Global Ozone Observing System of the World Meteorlogical Organization (WMO/GAW/GO3OS Station No. 252) since May of 1984. The daily measurements of total ozone and the vertical distribution of ozone amount have been made with the Dobson Spectrophotometer (No.124) on the roof of the Science Building on Yonsei campus. From 2004 through 2006, major parts of the manual operations are automated in measuring total ozone amount and vertical ozone profile through Umkehr method, and calibrating instrument by standard lamp tests with new hardware and software including step motor, rotary encoder, controller, and visual display. This system takes full advantage of Windows interface and information technology to realize adaptability to the latest Windows PC and flexible data processing system. This automatic system also utilizes card slot of desktop personal computer to control various types of boards in the driving unit for operating Dobson spectrophotometer and testing devices. Thus, by automating most of the manual work both in instrument operation and in data processing, subjective human errors and individual differences are eliminated. It is therefore found that the ozone data quality has been distinctly upgraded after automation of the Dobson instrument.

신경가동운동과 견갑골 자세교정운동이 오십견 환자에게 미치 는 영향 (Effects of Nerve Mobilization Exercise and Scapula Postural Correction Exercise for Adhesive Capsulitis Patients)

  • 정민근;김유리;김완기;전재국
    • 대한정형도수물리치료학회지
    • /
    • 제24권1호
    • /
    • pp.57-65
    • /
    • 2018
  • Background: This study examined the effects of nerve mobilization exercise and scapula postural correction exercise and scapula postural correction exercise after applying conservative physical therapy to frozen shoulder. Methods: Thirty-four outpatients were divided into a nerve mobilization exercise and scapula postural correction exercise group and scapula postural correction exercise group. Each group performed its own exercise 30 minutes per day, three times per week, for 6 weeks. Pain intensity was measured by the visual analogue scale. Range of motion was measured by the goniometer. The scapular position was measured by scapular index. Grasping power was measured by the Grip Track Commander. Measurements were made at baseline and six weeks after the intervention. Results: the visual analogue scale, range of motion (except lateral rotation), and grasping power for each group showed significant changes at baseline and six weeks after the intervention (p<.05). Significant differences were also evident between the two groups for these three measurements (p<.05). Conclusions: Nerve mobilization exercise & scapula postural correction exercise is more effective than scapula postural correction exercise for reducing pain intensity and increasing grasping power, scapular index and range of motion (except lateral rotation) in frozen shoulder syndrome patients.

두개강의 용적측정법이 해마의 용적측정술과 화소기반 형태계측술에 미치는 영향 (Effects of Various Intracranial Volume Measurements on Hippocampal Volumetry and Modulated Voxel-based Morphometry)

  • 태우석;김삼수;이강욱;남의철
    • Investigative Magnetic Resonance Imaging
    • /
    • 제13권1호
    • /
    • pp.63-73
    • /
    • 2009
  • 배경: 두개강내 용적에 대한 수동과 자동 측정법이 여성 주요 우울증 환자의 해마의 용적측정술과 modulated voxel-based morphometry (mVBM)의 결과에 미치는 영향을 알아보고자 한다. 방법: 21명의 여성 주요 우울증 환자와 성별, 나이의 분포가 비슷한 20명의 여성 정상인을 연구대상에 포함시켰다. 해마와 두개강내 용적은 수동으로 측정하였고, FreeSurfer 프로그램을 이용하여 두개강내 용적을 자동으로 측정하였다. 또한 회색질과 백색질의 부피도 SPM을 이용하여 자동으로 측정하였다. 결과: 수동으로 측정한 두개강의 용적을 통제변인으로 하여 분석한 통계분석의 결과가 FreeSurfer에 의해 측정된 두개강내 용적이나 뇌실질의 용적을 통제변인으로 한 통계분석의 결과보다 우울증 환자의 해마부피 감소와 mVBM 분석의 국조적 부피감소를 보다 민감하게 보여주었다. 수동적인 방법과 FreeSurfer에 의해 측정된 두개강내 용적은 정상인에서는 차이가 없었지만 (p = 0.696), 우울증 환자의 두개강 부피는 FreeSurfer를 이용해 측정한 두 개강의 부피가 더 작았다 (p = 0.000002). 우울증 환자의 전체 회색질의 부피는 수동으로 측정한 두개강의 용적을 통제변인으로 적용하였을 때 정상인의 회색질의 부피보다 작았고 (p = 0.000002), 해마의 부피도 수동으로 측정한 두 개 강의 부피를 통제변인으로 통계처리를 했을 때는 우울증환자의 해마가 뚜렷한 위축을 보였지만 (오른쪽, p = 0.014; 왼쪽, p = 0.004), 다른 측정법을 통제변인으로 했을 때는 유의하지 않았다 (p > 0.05). mVBM 분석에서는 수동으로 측정한 두개강의 부피를 통제변인으로 사용했을 때만 다중비교교정 후에 유의한 결과를 보였다 (FDR p < 0.05). 결론: 수동적인 방법으로 측정한 두개강의 용적이 FreeSurfer에 의해 자동으로 측정된 두개강의 용적이나 뇌실질의 부피보다 해마용적측정술과 mVBM 의 결과에 있어서 더 효율적으로 우울증이 있는 그룹과 없는 그룹의 차이를 보여주는 것에 민감한 결과를 보였다.

  • PDF