• Title/Summary/Keyword: Manual measurements

Search Result 230, Processing Time 0.024 seconds

Comparative Analysis of Accuracy between Computerized Tomography and Cephalogram for 3-Dimensional Measurement of Maxillofacial Structure (악안면 3차원 계측시 컴퓨터 단층촬영과 두부 방사선 규격사진의 정확성 비교 분석)

  • Paek, Jong-Su;Song, Jae-Chul;Lee, Hee-Kyung
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.123-137
    • /
    • 2001
  • Background: The purpose of this study is to evaluate the accuracy of measurements obtained from 3-dimensional computerized tomography and 3-dimensional cephalogram constructed by using the frontal and lateral cephalogram of six human dry skulls. Materials and Methods: After CT scans and each cephalograms were taken, 3-dimensional coordinates (X, Y, Z) of landmarks were obtained using computer programs. In this study, the accuracy of both methods were determined by means of 14 linear measurements compare with caliper measurements. Results: The standard deviation of landmarks of 3-dimensional CT and 3-dimensional cephalogram were 0.23 mm, and 0.30 mm in X axis, 0.27 mm and 0.25 mm in Y axis, and 0.27 mm and 0.31 mm in Z axis. In both methods, the standard deviation were less than 0.5 mm in all landmarks, and the most of landmarks showed less than 1 mm in range. Concerning the accuracy, the mean difference between 3-dimensional CT and manual measurements was 0.33 mm, and 1.13 mm between 3-dimensional cephalogram and manual measurements. The distance between RGo and LGo showed the largest difference (2.03 mm). There were highly significant, and large correlation with manual measurements in both methods (p<0.01). Conclusion: It is concluded that closeness of repeated measures to each skulls reveal the precision of both methods. Computerized tomography and cephalogram for 3-dimensional measurement of maxillofacial structure are equivalent in quality to caliper measurements.

  • PDF

Reliability and Validity of Ultrasound Imaging and sEMG Measurement to External Abdominal Oblique and Lumbar Multifidus Muscles (외복사근과 다열근에 대한 초음파 영상과 표면 근전도 측정방법의 신뢰도와 타당도)

  • Kim, Chang-Yong;Choi, Jong-Duk;Kim, Suhn-Yeop;Oh, Duck-Won;Kim, Jin-Kyung
    • Physical Therapy Korea
    • /
    • v.18 no.1
    • /
    • pp.37-46
    • /
    • 2011
  • The purpose of this study was to investigate intra-rater reliability and determine the validity of electromyography (EMG) measurements to represent muscle activity and ultrasonography (US) to represent muscle thickness during manual muscle testing (MMT) to external abdominal oblique (EO) and lumbar multifidus (MF). Twenty healthy subjects were recruited for this study and asked to perform MMT at differing levels. The subjects' muscle activity using EMG was measured by a ratio to maximum voluntary contraction (MVC) and root mean square (RMS) methods. The subjects' muscle thickness using US was measured by raw muscle thickness and change ratio of thickness to maximum (MVC) or resting condition. In three trials, measurements were performed on each subject by one examiner. The intra-rater reliability of measurements of EMG and US to EO and MF was calculated using intra-class coefficients. The intra-rater reliability of all measurements was excellent (ICC=.75~.98) in EMG and US. The conduct validity was calculated by one-way ANOVA with repeated measurements to compare whether the EMG and US measurements were different between MMT at different levels. There was only a significant difference between all grades at %MVC thickness measurement of US. These results suggest that a %MVC thickness measurement of US was a more sensitive and discriminate in all manual muscle testing grades. This information will be useful for the selection of US measurement and analysis methods in clinics.

The Effects of Gluteus Medius Strength Training on Ankle Stability in Patient with Chronic Ankle Sprains (중간볼기근 강화운동이 만성 발목염좌 환자의 발목 안정성에 미치는 효과)

  • Kim, Yoon-hwan;Park, Su-hyung;Song, Hyun-seung
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.59-67
    • /
    • 2018
  • Background: The purpose of this study was to investigate the effects of gluteus medius strength exercise on the ankle stability of high school student with chronic ankle sprains. Methods: A total of 30 participants were divided two groups. Experimental group was 15 participants applied gluteus medius strength exercise. Control group was 15 participants performing ankle strength exercise. This study was performed for 50 minutes per day, three a week for 6 weeks. All measurements were taken to a pre and post test. Strength was measured using Power Track ll. Balance was measured using Biodex balance system for Limits of Stability and Postural Stability. Ankle Stability was measured using Cumberland Ankle Instability Tool (CAIT). Results: In the case of gluteus medius strength, there were statistically significant differences between the experimental group and the control group. For ankle stability were statistically significant differences within the experimental group according to measurements taken by Limits of Stability, Postural Stability, and CAIT. A between group comparison showed a statistically significant difference for CAIT only. Conclusion: According to our measurements it appears that gluteus medius strength training was effective in benefiting muscular strength, balance and ankle stability among the physical education.

How to Effects of Manual Therapy : Chronic Low Back Pain Patients (도수치료가 만성요통환자의 기능회복에 미치는 영향)

  • Jung, Yeon-Woo;Lee, Woo-Hyung
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.50-56
    • /
    • 2010
  • Purpose : To evaluate effects of joint mobilization on the range of motion of chronic low back pain patients. Methods : The subjects were consisted of sixty patients who had non specific chronic low back pain(10 females. 10 males; mean aged 36.5). All subjects received modalities treatment with therapeutic massage for 10minutes and joint mobilization or manipulation for 10minutes per day and three times a week during 4 weeks period. The Multilevel Roland-Morris Disability Questionnaire(MR-MDQ) was used to measure functional disability level. Visual Analogue Scale(VAS) was used to measure subjective pain level. Remodified Schober test(RST) was used to measure forward flexion range of motion of lumbar segment. Finger-to-Floor test(F-T-FT) was used to measure forward flexion range of motion of full spine of low back pain patients. All measurements of each patients were measured at pre-treatment and 4 week post-treatment. Results : The MR-MDQ, VAS, RCT and F-T-FT were significantly different within-subjects(p<.05), Conclusion : The manual therapy included therapeutic massage and joint mobilization found that improved chronic low back pain patients. Further studies are needed to including more subjects on long-term outcomes.

  • PDF

Analysis of Technical Error of Manual Measurements (직접 측정한 인체치수의 기술적 오차 분석)

  • Park, Jinhee;Nam, Yun Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.4
    • /
    • pp.641-649
    • /
    • 2016
  • Highly precision body measurements represent basic data required by industry and researches who wish to utilize information about the human body. The proficiency and expertise of the measurers have a significant influence on the error and accuracy of data when various parts from multiple subjects' bodies are measured. Therefore, in order to measure accurate body measurements (when measuring bodies directly), it is necessary to conduct objective analyses on errors. This study calculated the Relative Technical Error of Measurement (%TEM) using data that measured each of 24 subjects and discussed errors and methods to reduce errors by conducting comparison analysis based on measured items and objects. The result of analysis indicated that the errors based on age and gender of the objects of measurement were minor; however, there were comparatively distinct differences in measured errors based on measured items. 'Right and left Shoulder Angle' for all measured subjects displayed the greatest errors and standard deviations. 'Height' dimension, Lateral Malleolus Height and Head Height had big errors; in addition, 'Circumference', Neck Base Circumference and Armscye Circumference also had big errors. More careful measurements of such items with big errors require additional educational plan such as a proposal for more objective and detailed measurement methods. Items with small errors but big standard deviations such as Waist Circumference, Calf Circumference, Minimum Leg Circumference, Chest Circumference, Hip Circumference and Waist Circumference confirmed that errors for them greatly decreased with repeated experiments and resultant measurers increased proficiency; consequently, repeated measuring experiments for these items greatly enhance accuracy.

Heart-Model-Based Automated Method for Left Ventricular Measurements in Cardiac MR: Comparison with Manual and Semi-automated Methods (자동화 방식 모델 기반 좌심방 파라미터 측정법: 수동 및 반자동 방식과의 비교)

  • Chae, Seung Hoon;Lee, Whal;Park, Eun-Ah;Chung, Jin Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.200-206
    • /
    • 2013
  • Purpose : To assess the effect of applying an automated heart model based measurements of left ventricle (LV) and compare with manual and semi-automated measurements at Cardiovascular MR Imaging. Materials and Methods: Sixty-two patients who underwent cardiac 1.5T MR imaging were included. Steady state free precession cine images of 20 phases per cardiac cycle were obtained in short axis views and both 2-chamber and 4-chamber views. Epicardial and endocardial contours were drawn in manual, automated, and semi-automated ways. Based on these acquired contour sets, the end-diastolic (ED) and end-systolic (ES) volumes, ejection fraction (EF), systolic volume (SV) and LV mass were calculated and compared. Results: In EDV and ESV, the differences among three measurement methods were not statistically significant (P = .399 and .145, respectively). However, in EF, SV, and LV mass, the differences were statistically significant (P=.001, <001, <001, respectively) and the measured value from automated method tend to be consistently higher than the values from other two methods. Conclusion: An automatic heart model-based method grossly overestimate EF, SV and LV mass compared with manual or semi-automated methods. Even though the method saves a considerable amount of efforts, further manual adjustment should be considered in critical clinical cases.

A Review of Case Reports on the Application of Acupuncture as a Treatment for Fracture since 2013 (골절에 침 치료를 적용한 2013년 이후 증례보고 문헌고찰)

  • Paik, Seung-Won;Nam, Kyeong-Ho;Choi, Seung-Kwan;Lee, Jung-Han;Han, Yun-Hee
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.31 no.4
    • /
    • pp.49-63
    • /
    • 2021
  • Objectives This study aimed to investigate the trend in treating fracture with acupuncture and to evaluate the quality of case reports. Methods All case reports of fractures treated with acupuncture were extracted from four Korean web databases. We classified these studies by five fracture sites and investigated frequently used meridian and acupoint, outcome measurements, treatment period. And we assessed the quality of the case reports by the STandards for Reporting Interventions in Clinical Trials of Acupuncture (STRICTA) guidelines. Results A total of 33 case reports were included. The outcome measurements were divided into six categories, and the outcome measurements used in more than three studies showed improvement in patient symptoms. The mainly used meridians for each fracture site were as follows: chest and abdomen (GB, LR, CV), back (BL, GB), upper limb (LI, TE), lower Limb (GB, ST, BL, SP). The most commonly used acupoints for each fracture site were as follows: chest and abdomen (Ashi points, GB24, GB25, GB26, LR13, LR14, CV16, CV17, CV18, CV19), back (BL23, BL24, BL25, BL26, BL40, BL51, BL52, BL60, GB34), upper limb (LI4, LI10, LI11, TE3), lower limb (GB34, GB40). According to the STRICTA guidelines, more than 54.54% of the reports were found to be 'not reported' or 'not sufficient' in the following categories: 'response sought', 'description of participating acupuncturist', and 'number of needle insertions per subject per session'. Conclusions The meridians and acupuncture points frequently used for acupuncture treatment of fractures were near the fracture site. Future clinical studies involving acupuncture must be reported in accordance with the STRICTA guidelines to improve transparency and uniformity.

Effects of Kinesio Taping Applied on the Ankle Instability to Range of Motion and Balance (발목 불안정성에 키네시오 테이핑적용이 관절가동범위 및 균형에 미치는 영향)

  • Seo, Tae-hwa;Go, Hyun-min;Park, Jong-hang;Kim, Yoon-hwan;Kim, Tae-won;Park, Hyun-sik
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.23 no.1
    • /
    • pp.7-13
    • /
    • 2017
  • Background: To evaluate the effect of Kinesio taping applied on the ankle instability, joint range of motion and balance. Methods: The participants included in this study were male and female, 20~30 ages, who experiencing an ankle sprain or had chronic pain, did not exercise during the intervention, and did not experience severe exercise at least 3 weeks before. A total of twenty-four participants were divided into two groups: Kinesio taping applied group (n=12) and control group (n=12). The experiment was conducted for a three days. Measurements were taken for ankle joint range of motion using goniometer, and measurements were taken for balance using good balance system. Pre-test measurements were conducted on before Kinesio taping apply, and 24 hours after, 48 hours after, 72 hours after measurements were conducted. Statistical analysis was done using a independent samples t-test and repeated measure ANOVA. Results: There were significant differences to the duration of intervention in ankle joint range of motion and balance within the both group. However, there was a significant differences Kinesio taping group when comparing the groups. Conclusions: According to the results of this study, applying Kinesio taping to ankle instability is more effective on ankle joint range of motion and to recover balance.

  • PDF

Automation of Roadway Lighting Illuminance Measurement

  • BAO, Jieyi;HU, Xiaoqiang;JIANG, Yi;LI, Shuo
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.705-711
    • /
    • 2022
  • Roadway lighting is an integral element of a highway system. Luminaires on roadways provide viewing conditions for drivers and pedestrians during nighttime in order to improve safety. It is time-consuming and labor-intensive to manually measure roadway illuminance at predetermined spots with a handheld illuminance meter. To improve the efficiency of illuminance measurement, a remote-control electrical cart and a drone were utilized to carry an illuminance meter for the measurements. The measurements were performed on the marked grid points along the pavement. To measure the illuminance manually, one person measures illuminance at each grid point with the handheld meter and another person records the illuminance value. To measure the illuminance with the remote-control cart, the illuminance meter is attached to the cart and it measures illuminance values continuously as the cart moves along the grid lines. With the drone, the meter records the illuminance continuously as the drone carries the meter and flies along the grid line. Because the drone can fly at different heights, the measurements can be done at different altitudes. The illuminance measurements using the cart and the drone are described in detail and compared with manual measurements in this paper. It is shown through this study that automated measurements can greatly improve the efficiency of roadway illuminance data measurements.

  • PDF

Effects of Deep Cervical Flexors Strengthening Exercise on Cervical-Shoulder Angle, Disability index and pain and in Patients with Chronic Neck Pain (깊은목굽힘근 강화운동이 만성 목통증 환자의 통증과 목-어깨각도, 장애지수 및 통증에 미치는 영향)

  • Kim, Jin-young
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.21 no.2
    • /
    • pp.33-37
    • /
    • 2015
  • Background: The purpose of this study on the effects of deep cervical flexors strengthening exercise to forward head posture and pain of neck in patients with chronic neck pain. Method: We selected 30 subjects among neck pain patients and carried out measurements. The subjects' forward head posture was measured including head tilt angle (HTA), neck flexion angle (NFA) and forward shoulder angle (FSA), neck disability index (NDI), numeric rating scale (NRS). The subjects underwent deep cervical flexors muscle strengthening with pressure bio-feedback device for 4 weeks. Then, after intervention, the subjects' forward head posture was measured again. It was performed Wilcoxon signed-ranks test for confirming the effect of deep cervical flexor muscles strengthening exercise. Results: As a result of comparison of measurements before and after intervention, we found that there were statistically significant improvement in the subjects' NDI, NRS and forward head posture including head tilt angle, neck flexion angle and forward shoulder angle. Conclusion: We concluded that deep cervical flexors strengthening exercise has the effect of alleviation of neck pain patients and is effective for forward head posture.

  • PDF