• Title/Summary/Keyword: Manual Exposure

Search Result 93, Processing Time 0.027 seconds

A Study on Dose Reduction Method according to Slice Thickness Change using Automatic Exposure Controller and Manual Exposure in Intervention (인터벤션에서 자동노출제어장치와 수동노출 사용 시 두께 변화에 따른 선량감소 방안 연구)

  • Hwang, Jun-Ho;Jung, Ku-Min;Choi, Ji-An;Kim, Hyun-Soo;Lee, Kyung-Bae
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.115-122
    • /
    • 2018
  • We aims to perform comparative analysis on the dose area and image qualities varying on the slice thickness when using Automatic Exposure Controller (AEC) and manual exposure; thus, it wants to suggest a measure to reduce exposure dose by setting the optimal examination condition for each slice thickness. The method was to set the thickness as Thin, Normal, and Heavy adult and evaluate the dose area, spatial resolution, low contrast resolution, Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) according to each slice thickness by using the AEC and the manual exposure controller. The dose area according to each slice thickness all increased both when using the AEC and the manual exposure. However, the manual exposure showed lower dose area product than the AEC. Spatial resolutions and low contrast resolutions were all observed to be higher than the evaluation standard. Also, the SNR and CNR of each thickness all increased when using the AEC. When using the manual exposure, SNR and CNR increased in all cases other than the Heavy Adult. Consequently, the Thin and Normal Adult showed dose reduction about 2 times when using the manual exposure controller, while ensuring the image quality. Heavy adult was able to maintain good image quality by using AEC.

A comparison of density of Insight and Ektaspeed plus dental x-ray films using automatic and manual processing (자동 및 수동현상에 따른 Insight 필름과 Ektaspeed Plus 필름의 흑화도 비교)

  • Yoon Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.31 no.1
    • /
    • pp.17-22
    • /
    • 2001
  • Purpose: To compare the film density of Insight dental X-ray film (Eastman Kodak Co., Rochester, NY, USA) with that of Ektaspeed Plus film (Eastman Kodak) under manual and automatic processing conditions. Materials and Methods : Insight and Ektaspeed Plus films were exposed at three different exposure conditions with an aluminum step wedge on the films under the three different exposure times. The exposed films were processed by both manual and automatic ways. The Base plus fog density and the optical density made by exposing step wedge were calculated using a digital densitometer (model 07-443, Victoreen Inc, Cleveland, Ohio, USA). The optical densities of the Insight and Ektaspeed film versus thickness of alumimun wedge at the same exposure time were plotted on the graphs. Statistical analyses were applied for comparing the optical densities of the two films. Results: The film density of both Insight films and Ektaspeed Plus films under automatic processing condition was significantly higher over the manual processing. The film density of Insight films was significantly higher than that of Ektaspeed Plus films on both automatic and manual processing conditions. Conclusion: The radiation exposure time can be reduced when using Insight over Ektaspeed Plus film. To take the full advantage of reducing exposure time, Insight film should be processed automatically.

  • PDF

Suggestion of The Manual Exposure Condition Guideline for Reducing Patient Dose in Digital Breast Tomosynthesis (디지털 유방단층촬영의 피폭선량 경감을 위한 수동 촬영조건의 가이드라인 제시)

  • Hong, Eun-Ae;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.483-491
    • /
    • 2016
  • The conditions after exposure to digital mammography and digital breast tomosynthesis were analyzed. The examinations for the ACR phantom were done using manual exposure, not auto exposure, to examine image discrimination and patient dose. As a result, the following results were derived: In the CC exposure, the kVp was 2kVp higher while mAs decreased to 58.6% for the 3D tomography. Such result showed an approximate decrease of 60mAs. At that time, the patients' Average Glandular Dose (AGD) was 1.65mGy in 2D and 1.87mGy in 3D; thus, AGD of 3D was shown to have about 1.13times higher. The result of the manual exposure revealed a reduced mAs of up to 80%; there was no effect in the assessment standard in terms of image discrimination, resulting in more than 10 points. When mAs was reduced to 80% in the manual exposure for ACR phantom, AGD was decreased to 0.66mGy. The diagnostic values of images were maintained and patients dose was reduced in the manual exposure in the AEC condition for 3D. Since the use of 3D has recently increased, using the manual exposure has been recommended in this study to improve the diagnostic value, while, simultaneously reducing patients dose.

Evaluation of Usefulness of Automatic Exposure Control (AEC) by Comparison Analysis of Entrance Surface Dose (ESD) and Entropy in Clinical Application of Digital Radiography (DR) (디지털 방사선 시스템의 노출 유형에 따른 임상 적용 시 입사표면선량 및 Entropy 비교분석을 통한 자동노출제어장치의 유용성 평가)

  • Choi, Ji-An;Hwang, Jun-Ho;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.276-283
    • /
    • 2019
  • The purpose of this study is to evaluate the usefulness of automatic exposure control (AEC) by analyzing entrance surface dose (ESD) and entropy on using automatic exposure and manual exposure. The experimental method was to measure the dose by placing a semiconductor dosimeter on the Rando Phantom for the Pelvis, Abdomen, Skull, and Chest regions. The DICOM file was simultaneously acquired and then entropy was analyzed by using Matlab. As a result, when using the automatic exposure control, dose of all sites was lower than manual exposure's dose and entropy was high. In addition, paired t-test was performed for each item and p<0.05 was found in each item. In conclusion, the use of automatic exposure control can be a useful method to contribute to the optimization of the exposure dose and the image quality by reducing the amount of unnecessary radiation amount and information loss that can occur in X-ray examination.

Comparison of the Breast Dose based on the Existence of the Bismuth Breast Protection Shield for Automatic Exposure Control and Manual Exposure Control with the Coronary Artery CT Angiography

  • Kim, Sang-Tae;Kang, Sang-Koo;Kim, Chong-Yeal
    • International Journal of Contents
    • /
    • v.7 no.4
    • /
    • pp.103-107
    • /
    • 2011
  • The effective dose and the organ absorbed dose, which are given to a breast in the cases of using and not using the bismuth breast protection shield for the protection of a breast with the coronary artery CT angiography, have been measured and compared for the manual exposure control (MEC)and the automatic exposure control (AEC). In the cases of using and not using the bismuth breast protection shield, it has been found that the measured dose shows the reduction of about 23 to 26% for the MEC and about 22 to 25% for the AEC when the shield is used compared to the case of not using it. By comparing the shield and non-shield cases for the AEC and the MEC, it can be said that the value measured by carrying out the scanning process with the AEC mode has decreased by about 24 to 30% compared to the case of applying the MEC mode. Such a result shows that it is recommended to use the AEC mode for the reduction of the patient's exposure dose during the CT examination.

The Evaluation of Radiation Dose by Exposure Method in Digital Magnification Mammography (디지털 유방확대촬영술에서 노출방식에 따른 피폭선량 평가)

  • Kim, Mi-Young;Kim, Hwa-Sun
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.293-298
    • /
    • 2012
  • In digital mammography, Exposure factor were automatically chosen using by measurement breast thickness and the density of mammary gland. It may cause a increase glandular dose. The purpose of this study was to investigate optimal image quality in digital magnification mammography to decrease radiation exposure of patient dose. Auto mode gives the best image quality however, AGD showed better image quality. Image quality of manual mode passed phantom test and SNR at 55% mAs of auto mode commonly used in the digital magnification mammography. Also it could reduce AGD. According to result, manual mode may reduce the unnecessary radiation exposure in digital magnification mammography.

Evaluation of Radiation Dose and Image Quality Between Manual and Automatic Exposure Control Mode According to Body Mass Index in Cardiac CT (체질량지수에 따른 심장 CT검사의 수동노출조절 방법과 자동노출조절 방법의 방사선량 및 화질 평가)

  • Kim, Hyeong-Jin;Moon, Il-Bong;Han, Jae-Bok;Choi, Nam-Gil;Jang, Seong-Ju
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.4
    • /
    • pp.290-299
    • /
    • 2013
  • This study included 198 patients who underwent prospectively electrocardiogram-triggered high-pitch spiral mode(FLASH mode) in cardiac CT for health check: 123 patients who underwent manual exposure control(Group A) and 75 patients who underwent automatic exposure control(Group B). Patients were classified according to BMI grades: Grade 1, Grade 2, Grade 3, Grade 4. Radiation dose, objective and subjective image quality between two groups were compared. In Group B, tube voltage were significantly decreased in all BMI grades. Both $CTDI_{vol}$ and effective dose were significantly reduced in the BMI Grade 1, 3, and 4 whereas they were slightly reduced in the Grade 2(p>0.05), SNR was significantly decreased in the Grade 1 and increased in the Grade 3(p<0.05), but there was no significant difference in the Grade 2, 4 between the two groups(p>0.05). CNR was significantly decreased in the Grade 1(p<0.05), and there was no significant difference in the Grade 2, 3, 4 between the two groups(p>0.05). The subjective image quality showed no significant difference in all BMI Grades between the two groups(p>0.05). Automatic exposure control can lead to a significant reduction of radiation exposure dose without degradation of subjective image quality.

An Effect of Cold Environment on Human's Physiological Responses and Task Performances (저온 작업환경이 인간의 생리적 반응 및 작업 수행도에 미치는 영향)

  • Ku, Hak-Keun;Kwak, Hyo-Yean
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.622-629
    • /
    • 2007
  • Some worker is occupationally exposed to cold and freezing environment. The cold stimuli in the working environment impose physiological and psychological loads on workers to decrease the task performance. The purpose of this study is to investigate the cold stimuli of cold and freezing stores widely used in Busan can make an effect on human's physiological responses and task performance, experimentally and analytically. In the experiment, 5 workers are selected as subjects, and then their skin temperatures of hand and ear, heart rates, blood pressure, and ring test performances in cold($3^{\circ}C$) and freezing($-22^{\circ}C$) stores were measured for 21 minutes and analyzed by using statistical method. It is observed that a physiological variation and the task performance are significantly influenced by an exposure time as well as a strength of cold stimuli. Also, it is suggested the exposure limiting times for the useful manual work and the performance predict model of the ring tasks. The result of this study will be useful for a fundamental data of which design the standard task time of manual tasks and solve the job placement problem of worker selection and placement in cold environment.

Potential Work-related Exposure to SARS-CoV-2 by Standard Occupational Grouping Based on Pre-lockdown Working Conditions in France

  • Narges Ghoroubi;Emilie Counil;Myriam Khlat
    • Safety and Health at Work
    • /
    • v.14 no.4
    • /
    • pp.488-491
    • /
    • 2023
  • This study aims to ascertain occupations potentially at greatest risk of exposure to SARS-CoV-2 based on pre-lockdown working conditions in France. We combined two French population-based surveys documenting workplace exposures to infectious agents, face-to-face contact with the public, and working with colleagues just before the pandemic. Then, for each 87-level standard French occupational grouping, we estimated the number and percentage of the French working population reporting these occupational exposure factors, by gender, using survey weights. As much as 40% (11 million) of all workers reported at least two exposure factors. Most of the workers concerned were in the healthcare sector. However, army/police officers, firefighters, hairdressers, teachers, cultural/sports professionals, and some manual workers were also exposed. Women were overrepresented in certain occupations with potentially higher risks of exposure such as home caregivers, childminders, and hairdressers. Our gender-stratified matrix can be used to assign prelockdown work-related exposures to cohorts implemented during the pandemic.

Pulmonary Toxicity and Recovery from Inhalation of Manual Metal Arc Stainless Steel Welding Fumes in Rats

  • Yang, Mi-Jin;Kim, Jin-Sung;Yang, Young-Su;Cho, Jae-Woo;Choi, Seong-Bong;Chung, Yong-Hyun;Kim, Yong-Bum;Cho, Kyu-Hyuk;Lim, Chae-Woong;Kim, Choong-Yong;Song, Chang-Woo
    • Toxicological Research
    • /
    • v.24 no.2
    • /
    • pp.119-127
    • /
    • 2008
  • The objectives of this study were to examine the lung injury and inflammation caused by manual metal arc stainless steel(MMA-SS) welding fume inhalation and to evaluate the recovery process. Sprague-Dawley rats were exposed to MMA-SS welding fumes for 2 h per day in a whole-body exposure chamber, with a total suspended particulate(TSP) concentration of $51.4{\pm}2.8mg/m^3$(low dose) or $84.6{\pm}2.9mg/m^3$(high dose) for 30 days. The animals were sacrificed after 30 days of exposure as well as after a 30-day recovery period. To assess the inflammatory or injury responses, cellular and biochemical parameters as well as cytokines were assayed in the bronchoalveolar lavage fluid(BALF). MMA-SS welding fume exposure led to a significant elevation in the number of alveolar macrophages(AM) and polymorphonuclear cells(PMN). Additionary, the values of $\beta$-n-acetyl glucosaminidase($\beta$-NAG) and lactate dehydrogenase(LDH) in the BALF were increased in the exposed group when compared to controls. After 30 days of recovery from exposure, a significant reduction in inflammatory parameters of BALF was observed between the exposed and recovered groups. Slight, but significant elevations were noted in the number of AM and PMN in the recovered groups, and AM that had been ingested fume particles still remain in the lungs. In conclusion, these results indicated that welding fumes induced inflammatory responses and cytotoxicity in the lungs of exposed rats. Fume particles were not fully cleared from lungs even after a 30-day recovery period.