• Title/Summary/Keyword: Manikin

Search Result 146, Processing Time 0.029 seconds

Dressing Poses in Relation to Clothing Thermal Insulation

  • Li, Jun;Zhang, Weiyuan;Liu, Yan
    • Fashion & Textile Research Journal
    • /
    • v.4 no.6
    • /
    • pp.544-549
    • /
    • 2002
  • By the movable thermal manikin developed by China Dong Hua university, the laws of clothing thermal insulation influenced by dressing poses are studied. It is found that $I_a$ on nude thermal manikin has no relation to testing pose as a whole (notable level is 5%), while the change of testing pose influences $I_a$ value on parts of body obviously. The testing result $I_{cle}$ on clothed thermal manikin has relation to testing pose. The $I_{cle}$ value of the whole body in seated pose decreases 20 percent compared with that in standing pose (notable level is 1%). In view of heat transmission theory, the reasons are pointed out based on the knowledge of heat transmission.

Wear Comfort Evaluation on Water-vapor-permeable (WVP) Garments Using a Movable Sweating Thermal Manikin (발한써멀마네킨을 이용한 투습방수의류의 착용쾌적성 평가)

  • Kang, Inhyeng;Lee, Han Sup
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.37 no.8
    • /
    • pp.1095-1106
    • /
    • 2013
  • This study evaluated the wear comfort properties of water-vapor-permeable (WVP) garments using a movable sweating thermal manikin. Manikin tests were performed in a climatic chamber (temperature T=20, $35{\pm}0.5^{\circ}C$ and relative humidity $H=50{\pm}10%$) using seven sportswear outfits (a long sleeve shirts and a long pants) made with seven different WVP fabrics. Physiological responses of wear trials could be correlated with measurement parameters of the thermal manikin experiment; subsequently, a regression model that represented a final comfort sensation could be obtained. The regression model developed in this work is based on thermal manikin measurements; consequently, it provides an independent comfort sensation level in a relatively short time at a low cost while maintaining the reproducibility of results. It translates into more actual choices for sportswear manufacturers and sportswear consumers.

Comparison of adult CPR skill scores: Real-time visual feedback manikin(Resusci Anne SkillReporterTM) vs. Non-feedback manikin(Actar 911 SquadronTM) (성인 심폐소생술 술기 점수 비교: 레어달 애니 스킬리포터 대 액타 911 마네킹)

  • Kim, Jee-Hee;Moon, Tae-Young;Uhm, Tai-Hwan
    • The Korean Journal of Emergency Medical Services
    • /
    • v.15 no.2
    • /
    • pp.101-108
    • /
    • 2011
  • Purpose: Cardiopulmonary resuscitation (CPR) prevents tissue necrosis of the brain and cardiac muscle in the cardiac arrest patient and requires exact skills in order to increase survival rate. Through comparison of the training effects of feedback manikin and non-feedback manikin, this study present the effective CPR device to CPR instructors. Method: This CPR course for 80 students by using Resusci Anne $SkillReporter^{TM}$ (RASR; Laerdal Medical, Stavanger, Norway) and Actar 911 $Squadron^{TM}$ (A911; Vital Signs, New Jersey, USA) held on December 22, 2009. Thirty seven students and two assistants were placed in one laboratory, there were five RASR manikins which provide the LED performance indicator, not the metronome. Forty two students and two assistants were placed in the other laboratory, there were 20 A911 manikins which don't provide any feedback indicator. Chest compression scores and ventilation compression scores obtaining from two groups were analysed statistically by using independent t-test. Results: Chest compression scores, average depth (mm) was 37.5 in RASR and 41.80 A911 (p=.004), too depth (#) was 2.8 in RASR and 19.4 A911 (p=.005), average number per min (#/min) was 64.4 in RASR and 68.2 A911 (p=.038), wrong hand position (#/min) was 10.9 in RASR and 30.8 A911 (p=.040). Four items that showed better scores in group RASR had statistically significant difference. Ventilation compression scores, percent correct (%) was 40.6 in RASR and 20.6 A911 (p<.001), number correct (#) was 4.7 in RASR and 2.1 A911 (p=.002), too fast (#) was 0.9 in RASR and 2.9 A911 (p=.003), average volume (ml) was 536.5 in RASR and 707.1 A911 (p=.011). Also, three items that showed better scores in group RASR had statistically significant difference. Conclusions: Regarding the positive effect of CPR training feedback, comparison between the real-time visual feedback manikin (RASR) and the non-feedback manikin (A911) showed that RASR had better results than A911 in chest compression except average number per min (it means that we need harder chest manikin) and ventilation. Verification of the training effect in the real world such as CPR outcomes is also necessary. A proper application of manikin in training circumstances and research on retention of CPR skills will be needed.

Transient Heat Flux Evaluation of Underwear for Protective Clothing using Sweating Manikin (발한 마네킹을 이용한 보호복용 언더웨어의 동적(Transient) 열류량 평가)

  • Park, Hye-Jun;Kim, Hyun-Jung;Hong, Kyung-Hi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.1
    • /
    • pp.157-165
    • /
    • 2008
  • Transient thermal response of five types of underwear(cotton jersey, wool jersey, nylon jersey, cotton mesh and polyester mesh) for a protective coverall is evaluated using a sweating thermal manikin. Experimental protocol for transient thermal response of the sweating thermal manikin was also proposed. As results, it was found that steady state thermal response from sweating thermal manikin was not sensitive enough to evaluate thermal comfort of the experimental garments. However, when half time is used as an index of the heat flux change in transient thermal response, difference was found among underwear materials. Half time of cotton was the shortest and heat transfer of cotton was the fastest followed by polyester mesh, cotton jersey, nylon jersey and wool jersey. Dynamic thermal response of wool underwear was quite different from that of cotton underwear. Wool shows quite less heat flow at the initial stage, however, moisture permeability of wool was higher than cotton at the later stage. It was difficult to distinguish surface temperature difference visually using thermogram taken right before the completion of dry and wet test in steady state thermal response.

Formulation of Human Manikin Models Representative of Korean Male Pilots (한국인 조종사의 대표적 인체모형군 생성)

  • Lee, Jong-Sun;Song, Young-Woong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.15-26
    • /
    • 2002
  • The anthropometric characteristics of the intended user population are most important parameters in the equipment and workplace layout design, particularly in the airplane cockpit design. Because human body is composed of multi-dimensional body segments, single 'average' or 'extreme' manikin is not sufficient in computer-aided design(CAD) environments. To overcome this limitation, we constructed a manikin group representing Korean Male pilot population. First, we identified 16 anthropometric variables which are important parameters in the evaluation of reach, visibility, and clearance. And we found their correlations and conducted a factor analysis. Four common factors were extracted in the factor analysis. The first one was related with length dimensions, the second was with the arm reach, the third was with the sitting height, and the last was with breadth-depth dimensions. Finally, 17 manikins were constructed and presented in the CAD prototype.

Development of Methods of Constructing Family of Manikin (마네킨 설계 파라메타 분석연구)

  • Kim, Jin-Ho;Whang, Min-Cheol
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.22 no.4
    • /
    • pp.663-675
    • /
    • 1996
  • Equipment designer should consider how many people and what range of percentiles will be used as design criteria. The usual practice is to select some large range of the accommodation, such as 5th-95th percentiles. There is difficulty in defining 95% accommodation of population in complex design problems which involve several body dimensions. This paper develops the methods of constructing family of manikins which are validated for population accommodation. They are analyzed by the interactions or relationships between body dimensions. Proposed manikin family represents multivariate body dimensions. Moreover, nine manikin families are determined for representative Korean of 30-50 aged by proposed manikin family. Their 2-D CAD modelings are developed for bio-mechanical and ergonomic applications.

  • PDF

Development and Standardization of Modified Self-Assessment Manikin for Emotional Valence and Arousal Manikin (정서가 및 각성수준에 대한 자가 평가 마네킹 척도개발 및 표준화)

  • Kang, Eun-Ho;Choi, Jeong-Eun;Ham, Byung-Joo;Seok, Jeong-Ho;Lee, Kyoung-Uk;Kim, Won;Lee, Seung-Hwan;Lim, Hyun-Kook;Park, Young-Min;Yang, Jong-Chul;Ahn, Meekyung;Lee, Jae Seon;Chae, Jeong-Ho
    • Anxiety and mood
    • /
    • v.7 no.2
    • /
    • pp.113-118
    • /
    • 2011
  • Objectives : The Self-Assessment Manikin (SAM) developed by Bradley and Lang is a non-verbal pictorial assessment tool that measures human emotion and has been widely used. However, the pictures in SAM have not been easy for Korean subjects to understand or relate to. The authors developed a new manikin (Emotional Valence and Arousal Manikin, EVAS) modeling it after Korean faces while modifying and standardizing the SAM. Methods : Forty-one healthy subjects participated in this study. They were asked to rate the emotional valence and level of arousal using both the SAM and EVAS after being exposed to pictures of facial expressions for affective neurosciences-Korean version. The internal consistency of the EVAS and the correlation between EVAS and SAM were examined. Resuts : Internal consistencies of the valence using the EVAS were from 0.63 (surprise) to 0.82 (happiness) and those of the arousal were from 0.90 to 0.95. Correlation coefficients of the valence and arousal between the SAM and EVAS were from 0.61 (both surprise and disgust) to 0.84 (neutral) and from 0.82 (sadness) to 0.94 (fear), respectively. Conclusions : We developed a new manikin (the EVAS) for the Korean population modifying and standardizing the SAM. The EVAS demonstrated a good internal consistency and validity. As such, it can be used in the field of human emotion research.

Physiological Responses of Cold Protective Clothing with Different clo Value (보온력 차이에 따른 방한복 상의의 인체착의 생리반응)

  • Lee, Jung-Sug;Kim, Hee-Eun;Song, Min-Kyu
    • Fashion & Textile Research Journal
    • /
    • v.10 no.5
    • /
    • pp.683-689
    • /
    • 2008
  • The purpose of this study was to investigate physiological responses such as rectal temperature, skin temperature, micro climate, sweat rate and subjective sensations using cold protective clothing with five different clo value. The clo value was measured by thermal manikin in windless condition. Healthy five 20's males volunteered as subjects for wearing trial experiment. The climate chamber was controlled at $50^{\circ}C$, 65% RH. The experiment consisted of repeated exercise and recovery periods. We found that the higher clo value has, the higher mean skin temperature, micro climate and sweat rate show. They felt warm and wet with higher insulation clothing. Thermal comfort increased in the last recovery period after exercise. There was significant difference between five cold protective clothing. In correlation analysis of clo value, it showed that correlation coefficient(r) values were more than 0.8. Therefore, in terms of clothing insulation, we found that correlation between thermal manikin experiment and wearing trial experiment was high. Clothing insulation could be variable according to many factors such as body movement, covering area, clothing gap, layering and design. Considering the body movement, we thought that insulation measurement need to carry out both thermal manikin experiment and wearing trial experiment.

Effects of garment types on thermal insulation using a thermal manikin (의복 형태가 보온력에 미치는 영향;써멀 마네킹 착용 실험에 의한)

  • 손원교;백윤정
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.8
    • /
    • pp.1110-1118
    • /
    • 1999
  • This study was to examine the effects of garment types on thermal insulation using a thermal manikin. cotton polyester wool silk and rayon were selected as outer wears like a blouse a skirt slacks and one-piece for this study Acetate was chosen as a lining. Brief and upper innerwear with long sleeves(cotton) were also chosen as the innerwear. The results were as follows: 1. The thermal insulation of the garment of single layer was in proportion to the covering area of garment in all types of clothing. 2. On adding the innerwear or the lining or both the thermal insulation of the each garment of single layer were showed a different trends by garment types. The thermal manikin insulations of one-piece dress adding the innerwear was higher than those of blouse-skirt suits. The thermal insulation of one-piece dress adding the innerwear and lining was lower than those of blouse-skirt suits. 3. The increasing rates of thermal insulation of multi-layered garments had different value by garment types but garment made of rayon and silk were showed very high increasing rates of thermal insulation. 4. The increasing rates of the thermal insulation of one-piece dress added the lining the innerwear or both except polyester showed the highest value and then blouse-slacks suits' turn came ound Blouse-skirt suits had the lowest the increasing rates of thermal insualition value.

  • PDF

The Effects of Textiles for Thermal Insulation Value Using a Thermal Manikin (써멀 마네킹 착용실험에 의한 보온력에 미치는 의복소재의 영향)

  • Son Won-Kyo;Choi Jeong-Wha
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.12 s.142
    • /
    • pp.141-151
    • /
    • 1999
  • This study was carried out to examine the effects of textile materials for thermal insulation value using a thermal manikin. Cotton, polyester, wool, silk and rayon were selected as outer wears like blouses, skirts, slacks, and one-pieces. Acetate was chosen as a lining. Brief and long sleeve upper underwear(cotton) were chosen as the inner wears. The results were as follows; There were no significant differences among the materials in skirts and blouse-skirt suits by the thermal manikin. However blouses, slacks, one-pieces and blouse-slacks suits were showed the effects of materials. Blouse-slacks suits was showed the highest thermal insulation value and one-piece had the lowest thermal insulation value.

  • PDF